diff --git a/docs/content/infrastructure/fdio_dc_testbed_specifications.md b/docs/content/infrastructure/fdio_dc_testbed_specifications.md
index 0e9f8ba2b8..3df698ac0d 100644
--- a/docs/content/infrastructure/fdio_dc_testbed_specifications.md
+++ b/docs/content/infrastructure/fdio_dc_testbed_specifications.md
@@ -19,7 +19,6 @@ Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
Management port, which are connected to two different VLANs.
#### LOM (IPMI) VLAN
-
- Subnet: 10.30.50.0/24
- Gateway: 10.30.50.1
- Broadcast: 10.30.50.255
@@ -54,8 +53,9 @@ To access these hosts, VPN connection is required.
11. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 2 0 0 0
12. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 6 0 0
13. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 0 0 .5 2 0
-13. 2-Node-SapphireRapids perf spr spr 4 4 4 0 0 0 0 0 0 0 0 0 0 8
- Totals: 28 35 18.5 7 1 2 1 2 4 7 2 15.5 2 8
+14. 2-Node-SapphireRapids perf spr spr 4 4 4 0 0 0 0 0 0 0 0 0 0 8
+15. 1-Node-SapphireRapids nomad spr na 4 4 0 0 0 0 0 0 0 0 0 0 0 4
+ Totals: 32 39 18.5 7 1 2 1 2 4 7 2 15.5 2 12
```
### 1-Node-Skylake Xeon Intel (1n-skx)
@@ -70,6 +70,12 @@ Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-E11) with NIC
ports connected back-to-back ([Server Types](#server-types)).
Used for FD.io VPP_Device functional driver tests.
+### 1-Node-Skylake Xeon Intel (1n-spr)
+
+Each 1-Node-SapphireRapids testbed includes one SUT (Server-Type-H7) with NIC
+ports connected back-to-back ([Server Types](#server-types)).
+Used for FD.io VPP_Device functional driver tests.
+
### 1-Node-Cascadelake Xeon Intel (1n-clx)
Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
@@ -215,8 +221,8 @@ FD.io CSIT lab contains following server types:
- PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
- PCIe Slot9 5e:00.xx: empty.
- Numa1: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot6 86:00.xx: empty.
- - PCIe Slot8 af:00.xx: empty.
+ - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel.
+ - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel.
- PCIe Slot10 d8:00.xx: empty.
3. **Server-Type-B7**: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
@@ -740,6 +746,27 @@ FD.io CSIT lab contains following server types:
- PCIe Slot9 af:00.xx: e810-2CQDA2-2p100GE Intel.
- PCIe Slot11 d8:00.xx: empty.
+30. **Server-Type-H7**: Purpose - SapphireRapids SUT for FD.io VPP_Device functional tests.
+ - Quantity: 2.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 1-node topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-741GE-TNRT.
+ - Motherboard: Super X13DEG-QT-P.
+ - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
+ - RAM Memory: 16* 32GB DDR5-4800.
+ - Disks: 2* 960GB SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe5.0 lanes)
+ - PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel.
+ - PCIe Slot4 3b:00.xx: e810-2CQDA2-2p100GE Intel.
+ - PCIe Slot10 5e:00.xx: empty.
+ - Numa1: (x16, x16, x16 PCIe5.0 lanes)
+ - PCIe Slot7 86:00.xx: empty.
+ - PCIe Slot9 af:00.xx: empty.
+ - PCIe Slot11 d8:00.xx: empty.
+
## Testbeds Configuration
### 1-Node-Skylake (1n-skx)
@@ -759,6 +786,10 @@ FD.io CSIT lab contains following server types:
- s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
- s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
- s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
+ - s1-t11-sut1-c5/p1 - 100GE-port1 e810-2p100GE.
+ - s1-t11-sut1-c5/p2 - 100GE-port2 e810-2p100GE.
+ - s1-t11-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
+ - s1-t11-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
- SUT [Server-Type-B6]:
- testbedname: testbed12.
- hostname: s2-t12-sut1.
@@ -773,6 +804,10 @@ FD.io CSIT lab contains following server types:
- s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
- s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
- s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
+ - s2-t12-sut1-c5/p1 - 100GE-port1 e810-2p100GE.
+ - s2-t12-sut1-c5/p2 - 100GE-port2 e810-2p100GE.
+ - s2-t12-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
+ - s2-t12-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
```
### 1-Node-ThunderX2 (1n-tx2)
@@ -808,6 +843,31 @@ FD.io CSIT lab contains following server types:
- s56-t14-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
```
+### 1-Node-SapphireRapids (1n-spr)
+
+```
+- SUT [Server-Type-H7]:
+ - testbedname: testbed15.
+ - hostname: s30-t15-sut1.
+ - IPMI IP: 10.30.50.30
+ - Host IP: 10.30.51.31
+ - portnames:
+ - s30-t15-sut1-c1/p1 - 100GE-port1 e810-2p100GE.
+ - s30-t15-sut1-c1/p2 - 100GE-port2 e810-2p100GE.
+ - s30-t15-sut1-c2/p1 - 100GE-port1 e810-2p100GE.
+ - s30-t15-sut1-c2/p2 - 100GE-port1 e810-2p100GE.
+- SUT [Server-Type-H7]:
+ - testbedname: testbed16.
+ - hostname: s31-t16-sut1.
+ - IPMI IP: 10.30.50.31
+ - Host IP: 10.30.51.31
+ - portnames:
+ - s31-t16-sut1-c1/p1 - 100GE-port1 e810-2p100GE.
+ - s31-t16-sut1-c1/p2 - 100GE-port2 e810-2p100GE.
+ - s31-t16-sut1-c2/p1 - 100GE-port1 e810-2p100GE.
+ - s31-t16-sut1-c2/p2 - 100GE-port1 e810-2p100GE.
+```
+
### 1-Node-Cascadelake (1n-clx)
```
@@ -1622,6 +1682,21 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
- s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2.
```
+### 1-Node-SapphireRapids (1n-spr)
+
+```
+- testbed15:
+ - ring1 100GE-ports e810-2p100GE:
+ - s30-t15-sut1-c1/p1 to s30-t15-sut1-c2/p1.
+ - ring2 100GE-ports e810-2p100GE:
+ - s30-t15-sut1-c1/p2 to s30-t15-sut1-c2/p2.
+- testbed16:
+ - ring1 100GE-ports e810-2p100GE:
+ - s31-t16-sut1-c1/p1 to s31-t16-sut1-c2/p1.
+ - ring2 100GE-ports e810-2p100GE:
+ - s31-t16-sut1-c1/p2 to s31-t16-sut1-c2/p2.
+```
+
### 2-Node-IxiaPS1L47 (2n-ps1)
```