-rw-r--r--docs/content/infrastructure/fdio_csit_testbed_versioning.md8
-rw-r--r--docs/content/infrastructure/fdio_dc_testbed_specifications.md85
-rw-r--r--docs/content/infrastructure/fdio_dc_vexxhost_inventory.md32
3 files changed, 106 insertions, 19 deletions
diff --git a/docs/content/infrastructure/fdio_csit_testbed_versioning.md b/docs/content/infrastructure/fdio_csit_testbed_versioning.md
index feb611b61b..8e923f93e2 100644
--- a/docs/content/infrastructure/fdio_csit_testbed_versioning.md
+++ b/docs/content/infrastructure/fdio_csit_testbed_versioning.md
@@ -36,6 +36,14 @@ environment versioning include:
Following is the list of CSIT versions to date:
+- Ver. 13 associated with CSIT rls2310 branch (
+ [HW](https://git.fd.io/csit/tree/docs/content/infrastructure/testbed_configuration?h=rls2310),
+ [CSIT](https://git.fd.io/csit/tree/?h=rls2310)
+ ).
+ - Intel NIC 700/800 series firmware upgrade based on DPDK compatibility
+ matrix.
+ - Mellanox 556A/CX6-DX/MCX713106AS-VEAT series firmware upgrade based on DPDK
+ compatibility matrix.
- Ver. 12 associated with CSIT rls2306 branch (
[HW](https://git.fd.io/csit/tree/docs/content/infrastructure/testbed_configuration?h=rls2306),
[CSIT](https://git.fd.io/csit/tree/?h=rls2306)
diff --git a/docs/content/infrastructure/fdio_dc_testbed_specifications.md b/docs/content/infrastructure/fdio_dc_testbed_specifications.md
index 0e9f8ba2b8..3df698ac0d 100644
--- a/docs/content/infrastructure/fdio_dc_testbed_specifications.md
+++ b/docs/content/infrastructure/fdio_dc_testbed_specifications.md
@@ -19,7 +19,6 @@ Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
Management port, which are connected to two different VLANs.
#### LOM (IPMI) VLAN
-
- Subnet: 10.30.50.0/24
- Gateway: 10.30.50.1
- Broadcast: 10.30.50.255
@@ -54,8 +53,9 @@ To access these hosts, VPN connection is required.
11. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 2 0 0 0
12. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 6 0 0
13. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 0 0 .5 2 0
-13. 2-Node-SapphireRapids perf spr spr 4 4 4 0 0 0 0 0 0 0 0 0 0 8
- Totals: 28 35 18.5 7 1 2 1 2 4 7 2 15.5 2 8
+14. 2-Node-SapphireRapids perf spr spr 4 4 4 0 0 0 0 0 0 0 0 0 0 8
+15. 1-Node-SapphireRapids nomad spr na 4 4 0 0 0 0 0 0 0 0 0 0 0 4
+ Totals: 32 39 18.5 7 1 2 1 2 4 7 2 15.5 2 12
```
### 1-Node-Skylake Xeon Intel (1n-skx)
@@ -70,6 +70,12 @@ Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-E11) with NIC
ports connected back-to-back ([Server Types](#server-types)).
Used for FD.io VPP_Device functional driver tests.
+### 1-Node-Skylake Xeon Intel (1n-spr)
+
+Each 1-Node-SapphireRapids testbed includes one SUT (Server-Type-H7) with NIC
+ports connected back-to-back ([Server Types](#server-types)).
+Used for FD.io VPP_Device functional driver tests.
+
### 1-Node-Cascadelake Xeon Intel (1n-clx)
Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
@@ -215,8 +221,8 @@ FD.io CSIT lab contains following server types:
- PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
- PCIe Slot9 5e:00.xx: empty.
- Numa1: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot6 86:00.xx: empty.
- - PCIe Slot8 af:00.xx: empty.
+ - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel.
+ - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel.
- PCIe Slot10 d8:00.xx: empty.
3. **Server-Type-B7**: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
@@ -740,6 +746,27 @@ FD.io CSIT lab contains following server types:
- PCIe Slot9 af:00.xx: e810-2CQDA2-2p100GE Intel.
- PCIe Slot11 d8:00.xx: empty.
+30. **Server-Type-H7**: Purpose - SapphireRapids SUT for FD.io VPP_Device functional tests.
+ - Quantity: 2.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 1-node topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-741GE-TNRT.
+ - Motherboard: Super X13DEG-QT-P.
+ - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
+ - RAM Memory: 16* 32GB DDR5-4800.
+ - Disks: 2* 960GB SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe5.0 lanes)
+ - PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel.
+ - PCIe Slot4 3b:00.xx: e810-2CQDA2-2p100GE Intel.
+ - PCIe Slot10 5e:00.xx: empty.
+ - Numa1: (x16, x16, x16 PCIe5.0 lanes)
+ - PCIe Slot7 86:00.xx: empty.
+ - PCIe Slot9 af:00.xx: empty.
+ - PCIe Slot11 d8:00.xx: empty.
+
## Testbeds Configuration
### 1-Node-Skylake (1n-skx)
@@ -759,6 +786,10 @@ FD.io CSIT lab contains following server types:
- s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
- s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
- s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
+ - s1-t11-sut1-c5/p1 - 100GE-port1 e810-2p100GE.
+ - s1-t11-sut1-c5/p2 - 100GE-port2 e810-2p100GE.
+ - s1-t11-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
+ - s1-t11-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
- SUT [Server-Type-B6]:
- testbedname: testbed12.
- hostname: s2-t12-sut1.
@@ -773,6 +804,10 @@ FD.io CSIT lab contains following server types:
- s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
- s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
- s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
+ - s2-t12-sut1-c5/p1 - 100GE-port1 e810-2p100GE.
+ - s2-t12-sut1-c5/p2 - 100GE-port2 e810-2p100GE.
+ - s2-t12-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
+ - s2-t12-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
```
### 1-Node-ThunderX2 (1n-tx2)
@@ -808,6 +843,31 @@ FD.io CSIT lab contains following server types:
- s56-t14-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
```
+### 1-Node-SapphireRapids (1n-spr)
+
+```
+- SUT [Server-Type-H7]:
+ - testbedname: testbed15.
+ - hostname: s30-t15-sut1.
+ - IPMI IP: 10.30.50.30
+ - Host IP: 10.30.51.31
+ - portnames:
+ - s30-t15-sut1-c1/p1 - 100GE-port1 e810-2p100GE.
+ - s30-t15-sut1-c1/p2 - 100GE-port2 e810-2p100GE.
+ - s30-t15-sut1-c2/p1 - 100GE-port1 e810-2p100GE.
+ - s30-t15-sut1-c2/p2 - 100GE-port1 e810-2p100GE.
+- SUT [Server-Type-H7]:
+ - testbedname: testbed16.
+ - hostname: s31-t16-sut1.
+ - IPMI IP: 10.30.50.31
+ - Host IP: 10.30.51.31
+ - portnames:
+ - s31-t16-sut1-c1/p1 - 100GE-port1 e810-2p100GE.
+ - s31-t16-sut1-c1/p2 - 100GE-port2 e810-2p100GE.
+ - s31-t16-sut1-c2/p1 - 100GE-port1 e810-2p100GE.
+ - s31-t16-sut1-c2/p2 - 100GE-port1 e810-2p100GE.
+```
+
### 1-Node-Cascadelake (1n-clx)
```
@@ -1622,6 +1682,21 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
- s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2.
```
+### 1-Node-SapphireRapids (1n-spr)
+
+```
+- testbed15:
+ - ring1 100GE-ports e810-2p100GE:
+ - s30-t15-sut1-c1/p1 to s30-t15-sut1-c2/p1.
+ - ring2 100GE-ports e810-2p100GE:
+ - s30-t15-sut1-c1/p2 to s30-t15-sut1-c2/p2.
+- testbed16:
+ - ring1 100GE-ports e810-2p100GE:
+ - s31-t16-sut1-c1/p1 to s31-t16-sut1-c2/p1.
+ - ring2 100GE-ports e810-2p100GE:
+ - s31-t16-sut1-c1/p2 to s31-t16-sut1-c2/p2.
+```
+
### 2-Node-IxiaPS1L47 (2n-ps1)
```
diff --git a/docs/content/infrastructure/fdio_dc_vexxhost_inventory.md b/docs/content/infrastructure/fdio_dc_vexxhost_inventory.md
index 140c74ffc4..a3e6d7538a 100644
--- a/docs/content/infrastructure/fdio_dc_vexxhost_inventory.md
+++ b/docs/content/infrastructure/fdio_dc_vexxhost_inventory.md
@@ -82,20 +82,24 @@ Captured inventory data:
### Rack YUL1-11 (3016.11)
- **name** | **oper-status** | **testbed-id** | **role** | **model** | **s/n** | **mgmt-ip4** | **ipmi-ip4** | **rackid** | **rackunit**
------------------------|-----------------|----------------|------------|----------------|-----------------|--------------|--------------|------------|--------------
- yul1-11-lb6m | up | switch | arm-uplink | ? | ? | ? | ? | 3016.11 | u48
- yul1-11-lf-tor-switch | up | switch | uplink | ? | ? | ? | ? | 3016.11 | u47
- mtl1-6-7050QX-32 | up | switch | uplink | ? | ? | ? | ? | 3016.11 | u46
- fdio-marvell-dev | up | N/A | dev | ThunderX-88XX | N/A | 10.30.51.38 | 10.30.50.38 | 3016.11 | u45
- s56-t14-sut1 | up | t14 | 1n-tx2 | ThunderX2-9980 | N/A | 10.30.51.71 | 10.30.50.71 | 3016.11 | u41-u42
- s78-t38-sut1 | up | t38 | 3n-icx | SYS-740GP-TNRT | C7470KL03P50450 | 10.30.51.78 | 10.30.50.78 | 3016.11 | u31-u34
- s79-t38-sut2 | up | t38 | 3n-icx | SYS-740GP-TNRT | C7470KL07P50297 | 10.30.51.79 | 10.30.50.79 | 3016.11 | u27-u30
- s80-t38-tg1 | up | t38 | 3n-icx | SYS-740GP-TNRT | C7470KL03P50454 | 10.30.51.80 | 10.30.50.80 | 3016.11 | u23-u26
- s55-t13-sut1 | up | t13 | 1n-tx2 | ThunderX2-9980 | N/A | 10.30.51.70 | 10.30.50.70 | 3016.11 | u11-u12
- s62-t34-sut1 | up | t34 | 3n-alt | WIWYNN | 04000059N0SC | 10.30.51.72 | 10.30.50.72 | 3016.11 | u9-u10
- s63-t34-sut2 | up | t34 | 3n-alt | WIWYNN | 0390003EN0SC | 10.30.51.73 | 10.30.50.73 | 3016.11 | u7-u8
- s64-t34-tg1 | up | t34 | 3n-alt | SYS-740GP-TNRT | C7470KK40P50249 | 10.30.51.74 | 10.30.50.74 | 3016.11 | u3-u6
+ **name** | **oper-status** | **testbed-id** | **role** | **model** | **s/n** | **mgmt-ip4** | **ipmi-ip4** | **rackid** | **rackunit**
+-----------------------|-----------------|----------------|--------------|----------------|-----------------|--------------|--------------|------------|--------------
+ yul1-11-lb6m | up | switch | arm-uplink | ? | ? | ? | ? | 3016.11 | u48
+ yul1-11-lf-tor-switch | up | switch | uplink | ? | ? | ? | ? | 3016.11 | u47
+ mtl1-6-7050QX-32 | up | switch | uplink | ? | ? | ? | ? | 3016.11 | u46
+ fdio-marvell-dev | up | N/A | dev | ThunderX-88XX | N/A | 10.30.51.38 | 10.30.50.38 | 3016.11 | u45
+ s21-nomad | up | nomad | nomad-client | SYS-741GE-TNRT | ?? | 10.30.51.21 | 10.30.50.21 | 3016.11 | u41-u44
+ s22-nomad | up | nomad | nomad-client | SYS-741GE-TNRT | ?? | 10.30.51.22 | 10.30.50.22 | 3016.11 | u37-u40
+ s78-t38-sut1 | up | t38 | 3n-icx | SYS-740GP-TNRT | C7470KL03P50450 | 10.30.51.78 | 10.30.50.78 | 3016.11 | u31-u34
+ s79-t38-sut2 | up | t38 | 3n-icx | SYS-740GP-TNRT | C7470KL07P50297 | 10.30.51.79 | 10.30.50.79 | 3016.11 | u27-u30
+ s80-t38-tg1 | up | t38 | 3n-icx | SYS-740GP-TNRT | C7470KL03P50454 | 10.30.51.80 | 10.30.50.80 | 3016.11 | u23-u26
+ s30-t15-sut1 | up | nomad | nomad-client | SYS-741GE-TNRT | ?? | 10.30.51.30 | 10.30.50.30 | 3016.11 | u19-u22
+ s31-t16-sut1 | up | nomad | nomad-client | SYS-741GE-TNRT | ?? | 10.30.51.31 | 10.30.50.31 | 3016.11 | u15-u18
+ s56-t14-sut1 | up | t14 | 1n-tx2 | ThunderX2-9980 | N/A | 10.30.51.71 | 10.30.50.71 | 3016.11 | u13-u14
+ s55-t13-sut1 | up | t13 | 1n-tx2 | ThunderX2-9980 | N/A | 10.30.51.70 | 10.30.50.70 | 3016.11 | u11-u12
+ s62-t34-sut1 | up | t34 | 3n-alt | WIWYNN | 04000059N0SC | 10.30.51.72 | 10.30.50.72 | 3016.11 | u9-u10
+ s63-t34-sut2 | up | t34 | 3n-alt | WIWYNN | 0390003EN0SC | 10.30.51.73 | 10.30.50.73 | 3016.11 | u7-u8
+ s64-t34-tg1 | up | t34 | 3n-alt | SYS-740GP-TNRT | C7470KK40P50249 | 10.30.51.74 | 10.30.50.74 | 3016.11 | u3-u6
### Rack YUL1-12 (3016.12)