diff options
Diffstat (limited to 'docs/content/infrastructure')
-rw-r--r-- | docs/content/infrastructure/fdio_dc_testbed_specifications.md | 86 |
1 files changed, 59 insertions, 27 deletions
diff --git a/docs/content/infrastructure/fdio_dc_testbed_specifications.md b/docs/content/infrastructure/fdio_dc_testbed_specifications.md index 3ca81cf796..439cfc31dd 100644 --- a/docs/content/infrastructure/fdio_dc_testbed_specifications.md +++ b/docs/content/infrastructure/fdio_dc_testbed_specifications.md @@ -129,7 +129,7 @@ Used for FD.io performance tests. ### 3-Node-Altra Arm Ampere (3n-alt) Each 3-Node-Altra testbed includes two SUTs (Server-Type-E23) and one -TG (Server-Type-F4) connected in a 3-node circular topology +TG (Server-Type-E32) connected in a 3-node circular topology ([Server Types](#server-types)). Used for FD.io performance tests. @@ -381,7 +381,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel. 11. **Server-Type-E11**: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests. - - Quantity: 2 + - Quantity: 2. - Physical connectivity: - IPMI and host management ports. - NIC ports connected into 1-node topologies. @@ -400,7 +400,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox. 12. **Server-Type-E21**: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing. - - Quantity: 2 + - Quantity: 2. - Physical connectivity: - IPMI(?) and host management ports. - NIC ports connected into 3-node topology. @@ -414,7 +414,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 11:00.xx: x520-2p10GE Intel. 13. **Server-Type-E22**: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing. - - Quantity: 1 + - Quantity: 1. - Physical connectivity: - IPMI and host management ports. - NIC ports connected into 2-node topologies. @@ -431,7 +431,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel. 14. **Server-Type-E23**: Purpose - Altra Arm Ampere SUT for FD.io performance testing. - - Quantity: 2 + - Quantity: 2. - Physical connectivity: - IPMI and host management ports. - NIC ports connected into 3-node topologies. @@ -443,10 +443,12 @@ FD.io CSIT lab contains following server types: - RAM Memory: 16* 8GB DDR4-3200MT/s - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983 - NICs configuration: - - Numa0: + - Numa0: (x16, x16 PCIe4.0 lanes) - PCIe Slot1 0004:04:00.x: xl710-QDA2-2p40GE Intel. + - PCIe Slot8 0001:00:00.x: ConnectX6-2p100GE Mellanox. - Numa1: - no cards. + 15. **Server-Type-E24**: Purpose - Altra Arm Ampere for FD.io build. - Quantity: 2. - Physical connectivity: @@ -459,8 +461,8 @@ FD.io CSIT lab contains following server types: - RAM Memory: 12* 16GB DDR4-3200MT/s - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983 -16. **Server-Type-E31**: Purpose - Skylake Xeon TG for FD.io performance testing. - - Quantity: 1 +16. **Server-Type-E31**: Purpose - Skylake Xeon Shared TG for FD.io performance testing. + - Quantity: 1. - Physical connectivity: - IPMI and host management ports. - NIC ports connected into 2-node and 3-node topologies. @@ -480,7 +482,28 @@ FD.io CSIT lab contains following server types: - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel. - PCIe Slot10 d8:00.xx: x710-4p10GE Intel. -17. **Server-Type-F1**: Purpose - Icelake Xeon SUT for FD.io performance testing. +17. **Server-Type-E32**: Purpose - Icelake Xeon Shared TG for FD.io performance testing. + - Quantity: 1. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node and/or 3-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-740GP-TNRT. + - Motherboard: Super X12DPG-QT6. + - Processors: 2* Intel Platinum 8358 2.6 GHz. + - RAM Memory: 16* 16GB DDR4-3200. + - Disks: 2* 960GB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe4.0 lanes) + - PCIe Slot2 4b:00.xx: xxv710-DA2-2p25GE Intel. + - PCIe Slot4 31:00.xx: xl710-QDA2-2p40GE Intel. + - PCIe Slot9 ff:00.xx: empty. + - Numa1: (x16, x16, x16 PCIe4.0 lanes) + - PCIe Slot6 ca:00.xx: e810-XXVDA4-4p25GE Intel. + - PCIe Slot8 b1:00.xx: e810-2CQDA2-2p100GE Intel. + - PCIe Slot10 ff:00.xx: empty. + +18. **Server-Type-F1**: Purpose - Icelake Xeon SUT for FD.io performance testing. - Quantity: 8. - Physical connectivity: - IPMI and host management ports. @@ -501,7 +524,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -18. **Server-Type-F2**: Purpose - Icelake Xeon TG for FD.io performance testing. +19. **Server-Type-F2**: Purpose - Icelake Xeon TG for FD.io performance testing. - Quantity: 3. - Physical connectivity: - IPMI and host management ports. @@ -522,7 +545,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -19. **Server-Type-F3**: Purpose - Icelake Xeon TG for FD.io performance testing. +20. **Server-Type-F3**: Purpose - Icelake Xeon TG for FD.io performance testing. - Quantity: 3. - Physical connectivity: - IPMI and host management ports. @@ -542,8 +565,9 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -20. **Server-Type-F4**: Purpose - Icelake Xeon Shared TG for FD.io performance testing. - - Quantity: 3. + +21. **Server-Type-F4**: Purpose - Icelake Xeon Shared TG for FD.io performance testing. + - Quantity: 2. - Physical connectivity: - IPMI and host management ports. - NIC ports connected into 2-node and/or 3-node testbed topologies. @@ -555,15 +579,15 @@ FD.io CSIT lab contains following server types: - Disks: 2* 960GB SATA SSD. - NICs configuration: - Numa0: (x16, x16, x16 PCIe4.0 lanes) - - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel. - - PCIe Slot4 3b:00.xx: empty. - - PCIe Slot9 5e:00.xx: empty. + - PCIe Slot2 4b:00.xx: xxv710-DA2-2p25GE Intel. + - PCIe Slot4 31:00.xx: empty. + - PCIe Slot9 ff:00.xx: empty. - Numa1: (x16, x16, x16 PCIe4.0 lanes) - - PCIe Slot6 86:00.xx: e810-XXVDA4-4p25GE Intel. - - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel. - - PCIe Slot10 d8:00.xx: empty. + - PCIe Slot6 ca:00.xx: e810-XXVDA4-4p25GE Intel. + - PCIe Slot8 b1:00.xx: e810-2CQDA2-2p100GE Intel. + - PCIe Slot10 ff:00.xx: empty. -21. **Server-Type-G1**: Purpose - SnowRidge Atom SUT for FD.io performance testing. +22. **Server-Type-G1**: Purpose - SnowRidge Atom SUT for FD.io performance testing. - Quantity: 2 - Physical connectivity: - IPMI and host management ports. @@ -578,7 +602,7 @@ FD.io CSIT lab contains following server types: - Numa0: (x16, PCIe3.0 lane) - PCIe BuiltIn ec:00.xx: e810-XXVDA4-4p25GE Intel. -22. **Server-Type-H1**: Purpose - SapphireRapids Xeon SUT for FD.io full system performance testing. +23. **Server-Type-H1**: Purpose - SapphireRapids Xeon SUT for FD.io full system performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -599,7 +623,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - PCIe Slot11 d8:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. -23. **Server-Type-H2**: Purpose - SapphireRapids Xeon TG for FD.io full system performance testing. +24. **Server-Type-H2**: Purpose - SapphireRapids Xeon TG for FD.io full system performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -620,7 +644,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - PCIe Slot11 d8:00.xx: empty. -24. **Server-Type-H3**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing. +25. **Server-Type-H3**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -641,7 +665,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot9 af:00.xx: e810-XXVDA4-4p25GE Intel. - PCIe Slot11 d8:00.xx: empty. -25. **Server-Type-H4**: Purpose - SapphireRapids Xeon TG for FD.io performance testing. +26. **Server-Type-H4**: Purpose - SapphireRapids Xeon TG for FD.io performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -662,7 +686,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot9 af:00.xx: empty. - PCIe Slot11 d8:00.xx: empty. -26. **Server-Type-H5**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing. +27. **Server-Type-H5**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing. - Quantity: 2. - Physical connectivity: - IPMI and host management ports. @@ -683,7 +707,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot9 af:00.xx: empty. - PCIe Slot11 d8:00.xx: empty. -27. **Server-Type-H6**: Purpose - SapphireRapids Xeon TG for FD.io performance testing. +28. **Server-Type-H6**: Purpose - SapphireRapids Xeon TG for FD.io performance testing. - Quantity: 2. - Physical connectivity: - IPMI and host management ports. @@ -1210,6 +1234,8 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - portnames: - s62-t34-sut1-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE. - s62-t34-sut1-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE. + - s62-t34-sut1-c8/p1 - 100GE-port1 ConnectX6-2p100GE Mellanox. + - s62-t34-sut1-c8/p2 - 100GE-port1 ConnectX6-2p100GE Mellanox. - SUT [Server-Type-E23]: - testbedname: testbed34. - hostname: s63-t34-sut2. @@ -1218,7 +1244,9 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - portnames: - s63-t34-sut2-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE. - s63-t34-sut2-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE. -- TG [Server-Type-F4]: + - s63-t34-sut2-c8/p1 - 100GE-port1 ConnectX6-2p100GE Mellanox. + - s63-t34-sut2-c8/p2 - 100GE-port1 ConnectX6-2p100GE Mellanox. +- TG [Server-Type-E32]: - testbedname: testbed34. - hostname: s64-t34-tg1. - IPMI IP: 10.30.50.74 @@ -1747,6 +1775,10 @@ To be completed. - s64-t34-tg1-c4/p1 - s62-t34-sut1-c1/p2. - s62-t34-sut1-c1/p1 - s63-t34-sut2-c1/p2. - s63-t34-sut2-c1/p1 - s64-t34-tg1-c4/p2. + - ring2 100GE-ports ConnectX6-2p100GE Mellanox on SUTs: + - s64-t34-tg1-c8/p1 - s62-t34-sut1-c8/p2. + - s62-t34-sut1-c8/p1 - s63-t34-sut2-c8/p2. + - s63-t34-sut2-c8/p1 - s64-t34-tg1-c8/p2. ``` ### 3-Node-Icelake (3n-icx) |