diff options
Diffstat (limited to 'docs/content/introduction/test_naming.md')
-rw-r--r-- | docs/content/introduction/test_naming.md | 107 |
1 files changed, 0 insertions, 107 deletions
diff --git a/docs/content/introduction/test_naming.md b/docs/content/introduction/test_naming.md deleted file mode 100644 index 22e2c0bf8a..0000000000 --- a/docs/content/introduction/test_naming.md +++ /dev/null @@ -1,107 +0,0 @@ ---- -title: "Test Naming" -weight: 4 ---- - -# Test Naming - -## Background - -{{< release_csit >}} follows a common structured naming convention for all -performance and system functional tests, introduced in CSIT 17.01. - -The naming should be intuitive for majority of the tests. Complete -description of CSIT test naming convention is provided on -[CSIT test naming wiki page](https://wiki.fd.io/view/CSIT/csit-test-naming). -Below few illustrative examples of the naming usage for test suites across CSIT -performance, functional and Honeycomb management test areas. - -## Naming Convention - -The CSIT approach is to use tree naming convention and to encode following -testing information into test suite and test case names: - -1. packet network port configuration - * port type, physical or virtual; - * number of ports; - * NIC model, if applicable; - * port-NIC locality, if applicable; -2. packet encapsulations; -3. VPP packet processing - * packet forwarding mode; - * packet processing function(s); -4. packet forwarding path - * if present, network functions (processes, containers, VMs) and their - topology within the computer; -5. main measured variable, type of test. - -Proposed convention is to encode ports and NICs on the left (underlay), -followed by outer-most frame header, then other stacked headers up to the -header processed by vSwitch-VPP, then VPP forwarding function, then encap on -vhost interface, number of vhost interfaces, number of VMs. If chained VMs -present, they get added on the right. Test topology is expected to be -symmetric, in other words packets enter and leave SUT through ports specified -on the left of the test name. Here some examples to illustrate the convention -followed by the complete legend, and tables mapping the new test filenames to -old ones. - -## Naming Examples - -CSIT test suite naming examples (filename.robot) for common tested VPP -topologies: - -1. **Physical port to physical port - a.k.a. NIC-to-NIC, Phy-to-Phy, P2P** - * *PortNICConfig-WireEncapsulation-PacketForwardingFunction- - PacketProcessingFunction1-...-PacketProcessingFunctionN-TestType* - * *10ge2p1x520-dot1q-l2bdbasemaclrn-ndrdisc.robot* => 2 ports of 10GE on Intel - x520 NIC, dot1q tagged Ethernet, L2 bridge-domain baseline switching with - MAC learning, NDR throughput discovery. - * *10ge2p1x520-ethip4vxlan-l2bdbasemaclrn-ndrchk.robot* => 2 ports of 10GE on - Intel x520 NIC, IPv4 VXLAN Ethernet, L2 bridge-domain baseline switching - with MAC learning, NDR throughput discovery. - * *10ge2p1x520-ethip4-ip4base-ndrdisc.robot* => 2 ports of 10GE on Intel x520 - NIC, IPv4 baseline routed forwarding, NDR throughput discovery. - * *10ge2p1x520-ethip6-ip6scale200k-ndrdisc.robot* => 2 ports of 10GE on Intel - x520 NIC, IPv6 scaled up routed forwarding, NDR throughput discovery. - * *10ge2p1x520-ethip4-ip4base-iacldstbase-ndrdisc.robot* => 2 ports of 10GE on - Intel x520 NIC, IPv4 baseline routed forwarding, ingress Access Control - Lists baseline matching on destination, NDR throughput discovery. - * *40ge2p1vic1385-ethip4-ip4base-ndrdisc.robot* => 2 ports of 40GE on Cisco - vic1385 NIC, IPv4 baseline routed forwarding, NDR throughput discovery. - * *eth2p-ethip4-ip4base-func.robot* => 2 ports of Ethernet, IPv4 baseline - routed forwarding, functional tests. -2. **Physical port to VM (or VM chain) to physical port - a.k.a. NIC2VM2NIC, - P2V2P, NIC2VMchain2NIC, P2V2V2P** - * *PortNICConfig-WireEncapsulation-PacketForwardingFunction- - PacketProcessingFunction1-...-PacketProcessingFunctionN-VirtEncapsulation- - VirtPortConfig-VMconfig-TestType* - * *10ge2p1x520-dot1q-l2bdbasemaclrn-eth-2vhost-1vm-ndrdisc.robot* => 2 ports - of 10GE on Intel x520 NIC, dot1q tagged Ethernet, L2 bridge-domain switching - to/from two vhost interfaces and one VM, NDR throughput discovery. - * *10ge2p1x520-ethip4vxlan-l2bdbasemaclrn-eth-2vhost-1vm-ndrdisc.robot* => 2 - ports of 10GE on Intel x520 NIC, IPv4 VXLAN Ethernet, L2 bridge-domain - switching to/from two vhost interfaces and one VM, NDR throughput discovery. - * *10ge2p1x520-ethip4vxlan-l2bdbasemaclrn-eth-4vhost-2vm-ndrdisc.robot* => 2 - ports of 10GE on Intel x520 NIC, IPv4 VXLAN Ethernet, L2 bridge-domain - switching to/from four vhost interfaces and two VMs, NDR throughput - discovery. - * *eth2p-ethip4vxlan-l2bdbasemaclrn-eth-2vhost-1vm-func.robot* => 2 ports of - Ethernet, IPv4 VXLAN Ethernet, L2 bridge-domain switching to/from two vhost - interfaces and one VM, functional tests. -3. **API CRUD tests - Create (Write), Read (Retrieve), Update (Modify), Delete - (Destroy) operations for configuration and operational data** - * *ManagementTestKeyword-ManagementOperation-ManagedFunction1-...- - ManagedFunctionN-ManagementAPI1-ManagementAPIN-TestType* - * *mgmt-cfg-lisp-apivat-func* => configuration of LISP with VAT API calls, - functional tests. - * *mgmt-cfg-l2bd-apihc-apivat-func* => configuration of L2 Bridge-Domain with - Honeycomb API and VAT API calls, functional tests. - * *mgmt-oper-int-apihcnc-func* => reading status and operational data of - interface with Honeycomb NetConf API calls, functional tests. - * *mgmt-cfg-int-tap-apihcnc-func* => configuration of tap interfaces with - Honeycomb NetConf API calls, functional tests. - * *mgmt-notif-int-subint-apihcnc-func* => notifications of interface and - sub-interface events with Honeycomb NetConf Notifications, functional tests. - -For complete description of CSIT test naming convention please refer to -[CSIT test naming wiki page](https://wiki.fd.io/view/CSIT/csit-test-naming>). |