diff options
Diffstat (limited to 'docs/content/introduction/test_naming.md')
-rw-r--r-- | docs/content/introduction/test_naming.md | 107 |
1 files changed, 107 insertions, 0 deletions
diff --git a/docs/content/introduction/test_naming.md b/docs/content/introduction/test_naming.md new file mode 100644 index 0000000000..22e2c0bf8a --- /dev/null +++ b/docs/content/introduction/test_naming.md @@ -0,0 +1,107 @@ +--- +title: "Test Naming" +weight: 4 +--- + +# Test Naming + +## Background + +{{< release_csit >}} follows a common structured naming convention for all +performance and system functional tests, introduced in CSIT 17.01. + +The naming should be intuitive for majority of the tests. Complete +description of CSIT test naming convention is provided on +[CSIT test naming wiki page](https://wiki.fd.io/view/CSIT/csit-test-naming). +Below few illustrative examples of the naming usage for test suites across CSIT +performance, functional and Honeycomb management test areas. + +## Naming Convention + +The CSIT approach is to use tree naming convention and to encode following +testing information into test suite and test case names: + +1. packet network port configuration + * port type, physical or virtual; + * number of ports; + * NIC model, if applicable; + * port-NIC locality, if applicable; +2. packet encapsulations; +3. VPP packet processing + * packet forwarding mode; + * packet processing function(s); +4. packet forwarding path + * if present, network functions (processes, containers, VMs) and their + topology within the computer; +5. main measured variable, type of test. + +Proposed convention is to encode ports and NICs on the left (underlay), +followed by outer-most frame header, then other stacked headers up to the +header processed by vSwitch-VPP, then VPP forwarding function, then encap on +vhost interface, number of vhost interfaces, number of VMs. If chained VMs +present, they get added on the right. Test topology is expected to be +symmetric, in other words packets enter and leave SUT through ports specified +on the left of the test name. Here some examples to illustrate the convention +followed by the complete legend, and tables mapping the new test filenames to +old ones. + +## Naming Examples + +CSIT test suite naming examples (filename.robot) for common tested VPP +topologies: + +1. **Physical port to physical port - a.k.a. NIC-to-NIC, Phy-to-Phy, P2P** + * *PortNICConfig-WireEncapsulation-PacketForwardingFunction- + PacketProcessingFunction1-...-PacketProcessingFunctionN-TestType* + * *10ge2p1x520-dot1q-l2bdbasemaclrn-ndrdisc.robot* => 2 ports of 10GE on Intel + x520 NIC, dot1q tagged Ethernet, L2 bridge-domain baseline switching with + MAC learning, NDR throughput discovery. + * *10ge2p1x520-ethip4vxlan-l2bdbasemaclrn-ndrchk.robot* => 2 ports of 10GE on + Intel x520 NIC, IPv4 VXLAN Ethernet, L2 bridge-domain baseline switching + with MAC learning, NDR throughput discovery. + * *10ge2p1x520-ethip4-ip4base-ndrdisc.robot* => 2 ports of 10GE on Intel x520 + NIC, IPv4 baseline routed forwarding, NDR throughput discovery. + * *10ge2p1x520-ethip6-ip6scale200k-ndrdisc.robot* => 2 ports of 10GE on Intel + x520 NIC, IPv6 scaled up routed forwarding, NDR throughput discovery. + * *10ge2p1x520-ethip4-ip4base-iacldstbase-ndrdisc.robot* => 2 ports of 10GE on + Intel x520 NIC, IPv4 baseline routed forwarding, ingress Access Control + Lists baseline matching on destination, NDR throughput discovery. + * *40ge2p1vic1385-ethip4-ip4base-ndrdisc.robot* => 2 ports of 40GE on Cisco + vic1385 NIC, IPv4 baseline routed forwarding, NDR throughput discovery. + * *eth2p-ethip4-ip4base-func.robot* => 2 ports of Ethernet, IPv4 baseline + routed forwarding, functional tests. +2. **Physical port to VM (or VM chain) to physical port - a.k.a. NIC2VM2NIC, + P2V2P, NIC2VMchain2NIC, P2V2V2P** + * *PortNICConfig-WireEncapsulation-PacketForwardingFunction- + PacketProcessingFunction1-...-PacketProcessingFunctionN-VirtEncapsulation- + VirtPortConfig-VMconfig-TestType* + * *10ge2p1x520-dot1q-l2bdbasemaclrn-eth-2vhost-1vm-ndrdisc.robot* => 2 ports + of 10GE on Intel x520 NIC, dot1q tagged Ethernet, L2 bridge-domain switching + to/from two vhost interfaces and one VM, NDR throughput discovery. + * *10ge2p1x520-ethip4vxlan-l2bdbasemaclrn-eth-2vhost-1vm-ndrdisc.robot* => 2 + ports of 10GE on Intel x520 NIC, IPv4 VXLAN Ethernet, L2 bridge-domain + switching to/from two vhost interfaces and one VM, NDR throughput discovery. + * *10ge2p1x520-ethip4vxlan-l2bdbasemaclrn-eth-4vhost-2vm-ndrdisc.robot* => 2 + ports of 10GE on Intel x520 NIC, IPv4 VXLAN Ethernet, L2 bridge-domain + switching to/from four vhost interfaces and two VMs, NDR throughput + discovery. + * *eth2p-ethip4vxlan-l2bdbasemaclrn-eth-2vhost-1vm-func.robot* => 2 ports of + Ethernet, IPv4 VXLAN Ethernet, L2 bridge-domain switching to/from two vhost + interfaces and one VM, functional tests. +3. **API CRUD tests - Create (Write), Read (Retrieve), Update (Modify), Delete + (Destroy) operations for configuration and operational data** + * *ManagementTestKeyword-ManagementOperation-ManagedFunction1-...- + ManagedFunctionN-ManagementAPI1-ManagementAPIN-TestType* + * *mgmt-cfg-lisp-apivat-func* => configuration of LISP with VAT API calls, + functional tests. + * *mgmt-cfg-l2bd-apihc-apivat-func* => configuration of L2 Bridge-Domain with + Honeycomb API and VAT API calls, functional tests. + * *mgmt-oper-int-apihcnc-func* => reading status and operational data of + interface with Honeycomb NetConf API calls, functional tests. + * *mgmt-cfg-int-tap-apihcnc-func* => configuration of tap interfaces with + Honeycomb NetConf API calls, functional tests. + * *mgmt-notif-int-subint-apihcnc-func* => notifications of interface and + sub-interface events with Honeycomb NetConf Notifications, functional tests. + +For complete description of CSIT test naming convention please refer to +[CSIT test naming wiki page](https://wiki.fd.io/view/CSIT/csit-test-naming>). |