diff options
Diffstat (limited to 'docs/lab/Testbeds_Xeon_Skx_Arm_Atom.md')
-rw-r--r-- | docs/lab/Testbeds_Xeon_Skx_Arm_Atom.md | 190 |
1 files changed, 157 insertions, 33 deletions
diff --git a/docs/lab/Testbeds_Xeon_Skx_Arm_Atom.md b/docs/lab/Testbeds_Xeon_Skx_Arm_Atom.md index 1875c31b4a..3227ee09d4 100644 --- a/docs/lab/Testbeds_Xeon_Skx_Arm_Atom.md +++ b/docs/lab/Testbeds_Xeon_Skx_Arm_Atom.md @@ -1,8 +1,12 @@ ## FD.io CSIT testbeds - Xeon Skylake, Arm, Atom -This is a low-level design implemented as an extensions of FD.io CSIT lab to accommodate the new Intel Xeon Skylake, Arm AArch64 and Atom devices. Content has been copied from [FD.io CSIT testbeds wiki page: Xeon_skx, Arm, Atom](https://wiki.fd.io/view/CSIT/Testbeds:_Xeon_Skx,_Arm,_Atom). + +This is a low-level design implemented as an extensions of FD.io CSIT lab to +accommodate the new Intel Xeon Skylake, Arm AArch64 and Atom devices. ## Testbeds Overview + ### Testbeds Type Breakdown + ``` #. CSIT_tb. Purpose. SUT. TG. #tb. #SUTs. #TGs. #skx_node. 1. 1-node Xeon. func. skx. n/a. 2. 2. 0. 2. @@ -17,31 +21,57 @@ This is a low-level design implemented as an extensions of FD.io CSIT lab to acc ``` ### 1-Node Xeon Testbeds -One 1-node Xeon testbed for VPP_Device tests is built using one SUT (Type-6 server), with NIC ports connected back-to-back. + +One 1-node Xeon testbed for VPP_Device tests is built using one SUT (Type-6 +server), with NIC ports connected back-to-back. ### 2-Node Xeon Testbeds -Four 2-node Xeon testbeds (are expected to be built|are built), with each testbed using one SUTs (Type-1 server) and one TG (Type-2 server) connected back-to-back. NIC cards placement into slots and NIC ports connectivity is following the testbed specification included in next sections. + +Four 2-node Xeon testbeds (are expected to be built|are built), with each +testbed using one SUTs (Type-1 server) and one TG (Type-2 server) connected +back-to-back. NIC cards placement into slots and NIC ports connectivity is +following the testbed specification included in next sections. ### 3-Node Xeon Testbeds -Two 3-node Xeon testbeds (are expected to be built|are built), with each testbed using two SUTs (Type-1 server) and one TG (Type-2 server) connected in full-mesh triangle. NIC cards placement into slots and NIC ports connectivity is following the testbed specification included in next sections. + +Two 3-node Xeon testbeds (are expected to be built|are built), with each testbed +using two SUTs (Type-1 server) and one TG (Type-2 server) connected in full-mesh +triangle. NIC cards placement into slots and NIC ports connectivity is following +the testbed specification included in next sections. ### 1-Node Arm Marvell ThunderX2 Testbed -One 1-node ThunderX2 testbed for VPP_Device tests is expected to be built using one SUT (Type-9 server), with NIC ports connected back-to-back. + +One 1-node ThunderX2 testbed for VPP_Device tests is expected to be built using +one SUT (Type-9 server), with NIC ports connected back-to-back. ### 3-Node Arm Huawei TaiShan Testbed -One 3-node TaiShan testbed is built, with each testbed using two SUTs (Type-3 server) and one TG (Type-2 server) connected in full-mesh triangle. NIC cards placement into slots and NIC ports connectivity is following the testbed specification included in next sections. + +One 3-node TaiShan testbed is built, with each testbed using two SUTs (Type-3 +server) and one TG (Type-2 server) connected in full-mesh triangle. NIC cards +placement into slots and NIC ports connectivity is following the testbed +specification included in next sections. ### 3-Node Arm Marvell MACCHIATObin Testbed -One 3-node MACCHIATObin testbeds is built, with each testbed using two SUTs (Type-4 server) and one TG (Type-2 server) connected in full-mesh triangle. Built-in NIC ports connectivity is following the testbed specification included in next sections. + +One 3-node MACCHIATObin testbeds is built, with each testbed using two SUTs +(Type-4 server) and one TG (Type-2 server) connected in full-mesh triangle. +Built-in NIC ports connectivity is following the testbed specification included +in next sections. ### TCP/IP and L47 Testbeds + One 2-node Ixia PS One and Xeon server testbed, for TCP/IP host stack tests. ### Atom Testbeds -One 3-node Atom (Netgate based) testbed is built consisting of three SUTs (Type-5 Netgate device.) NIC cards placement into slots and NIC ports connectivity is following the testbed specification included in the next section. +One 3-node Atom (Netgate based) testbed is built consisting of three SUTs +(Type-5 Netgate device.) NIC cards placement into slots and NIC ports +connectivity is following the testbed specification included in the next +section. ## Inventory + ### Appliances + ``` 1. Ixia PerfectStorm One Appliance - 1 * PS10GE4NG @@ -56,6 +86,7 @@ One 3-node Atom (Netgate based) testbed is built consisting of three SUTs (Type- ``` ### Arm Servers + ``` 1. Arm Cortex A-72 servers - 1 * ThunderX2 @@ -95,6 +126,7 @@ Huawei TaiShan 2280 | CSIT Performance | Up, Manual perf experiments | s17-t33-s | | VPP dev debug | Up, Manual VPP Device experiments, Full Skx TG too much for it - suggest to use LXC/DRC TG(!) | fdio-mcbin3 | 10.30.51.43 | 10.30.51.49, then connect to /dev/ttyUSB2 | 4 | 16GB | 2x10GbE SFP+ | Ubuntu 16.04.5 ### Xeon and Atom Servers + ``` 1. Intel Xeon servers: - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors. @@ -112,6 +144,7 @@ Huawei TaiShan 2280 | CSIT Performance | Up, Manual perf experiments | s17-t33-s ``` ### Network Interface Cards + ``` 1. 10GE NICs - 14 * Intel® Ethernet Converged Network Adapter X710-DA4 @@ -126,7 +159,9 @@ Huawei TaiShan 2280 | CSIT Performance | Up, Manual perf experiments | s17-t33-s ``` ### Pluggables and Cables + Pluggables: + ``` 1. 10GE SFP+ - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics @@ -140,6 +175,7 @@ Pluggables: ``` Standalone cables: + ``` 1. 10GE - None @@ -152,25 +188,36 @@ Standalone cables: ``` ### Other Network Cards + Any QATs? ## Installation Status -Lab installation status is tracked by LF IT team in [FD.io Server Status](https://docs.google.com/document/d/16TdvGC73wuNQjkP355MTXRckv7yqnaxJkWwX7G7izEo/edit?ts=5b10411b#heading=h.dprb64shku8u). + +Lab installation status is tracked by LF IT team in +[FD.io Server Status](https://docs.google.com/document/d/16TdvGC73wuNQjkP355MTXRckv7yqnaxJkWwX7G7izEo/edit?ts=5b10411b#heading=h.dprb64shku8u). ## Server/Device Management and Naming + ### Server Management Requirements + Total of 20 SM SYS-7049GP-TRT servers are made available for FD.IO CSIT testbed. -For management purposes, each server must have following two ports connected to the management network: +For management purposes, each server must have following two ports connected to +the management network: + ``` - 1GE IPMI port - IPMI - Intelligent Platform Management Interface. - - Required for access to embedded server management with WebUI, CLI, SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates. + - Required for access to embedded server management with WebUI, CLI, SNMPv3, + IPMIv2.0, for firmware (BIOS) and OS updates. - 1GE/10GE management port - hostOS management port for general system management. ``` ### Server and Port Naming Convention -Following naming convention is used within this page to specify physical connectivity and wiring across defined CSIT testbeds: + +Following naming convention is used within this page to specify physical +connectivity and wiring across defined CSIT testbeds: + ``` - testbedname: testbedN. - hostname: @@ -190,7 +237,10 @@ Following naming convention is used within this page to specify physical connect ``` ### Server Management - Addressing -Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a Management port, which are connected to two different VLANs. + +Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a Management +port, which are connected to two different VLANs. + ``` 1. LOM (IPMI) VLAN: - Subnet: 10.30.50.0/24 @@ -205,6 +255,7 @@ Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a Management port - DNS1: 199.204.44.24 - DNS2: 199.204.47.54 ``` + To access these hosts, an VPN connection is required. ### LOM (IPMI) VLAN IP Addresses @@ -214,9 +265,14 @@ To access these hosts, an VPN connection is required. .. ## Testbeds Specification - Target Build + ### Server/Ports Naming, NIC Placement + #### 1-Node Xeon -Each server in 1-node Xeon topology has its NIC cards placed, and NIC cards and ports indexed per following specification: + +Each server in 1-node Xeon topology has its NIC cards placed, and NIC cards and +ports indexed per following specification: + ``` - Server1 [Type-6]: - testbedname: testbed11. @@ -249,7 +305,10 @@ Each server in 1-node Xeon topology has its NIC cards placed, and NIC cards and ``` #### 2-Node Xeon -Each server in 2-node Xeon topology has its NIC cards placed, and NIC cards and ports indexed per following specification: + +Each server in 2-node Xeon topology has its NIC cards placed, and NIC cards and +ports indexed per following specification: + ``` - Server3 [Type-1]: - testbedname: testbed21. @@ -366,7 +425,10 @@ Each server in 2-node Xeon topology has its NIC cards placed, and NIC cards and ``` #### 3-Node Xeon -Each server in 3-node Xeon topology has its NIC cards placed, and NIC cards and ports indexed per following specification: + +Each server in 3-node Xeon topology has its NIC cards placed, and NIC cards and +ports indexed per following specification: + ``` - Server11 [Type-1]: - testbedname: testbed31. @@ -455,6 +517,7 @@ Each server in 3-node Xeon topology has its NIC cards placed, and NIC cards and ``` #### 1-Node Arm + ``` - Server17 [Type-3]: - testbedname: testbed13. @@ -471,7 +534,9 @@ Each server in 3-node Xeon topology has its NIC cards placed, and NIC cards and ``` #### 3-Node Arm + Note: Server19 (TG) is shared between testbed33 & testbed34 + ``` - Server17 [Type-3]: - testbedname: testbed33. @@ -528,7 +593,10 @@ Note: Server19 (TG) is shared between testbed33 & testbed34 ``` #### TCP/IP and L47 -Each server (appliance) in 2-node TCP/IP topology has its NIC cards placed, and NIC cards and ports indexed per following specification: + +Each server (appliance) in 2-node TCP/IP topology has its NIC cards placed, and +NIC cards and ports indexed per following specification: + ``` - Server25 [Type-8]: - testbedname: testbed25. @@ -553,7 +621,9 @@ Each server (appliance) in 2-node TCP/IP topology has its NIC cards placed, and ``` #### 3-Node Atom + Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. + ``` - Server22 [Type-5]: - testbedname: testbed35. @@ -585,8 +655,12 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. ``` ### Physical Connectivity within Testbeds + #### 1-Node Xeon -Two 1-Node testbeds are constructed by connecting 2 Xeon servers using below specification: + +Two 1-Node testbeds are constructed by connecting 2 Xeon servers using below +specification: + ``` - testbed11: - ring1 10GE-ports x710-4p10GE: @@ -609,7 +683,10 @@ Two 1-Node testbeds are constructed by connecting 2 Xeon servers using below spe ``` #### 2-Node Xeon -Four 2-Node testbeds are constructed by connecting 8 Xeon servers using below specification: + +Four 2-Node testbeds are constructed by connecting 8 Xeon servers using below +specification: + ``` - testbed21: - ring1 10GE-ports x710-4p10GE on SUT: @@ -678,7 +755,10 @@ Four 2-Node testbeds are constructed by connecting 8 Xeon servers using below sp ``` #### 3-Node Xeon -Two 3-Node testbeds are constructed by connecting 6 Xeon servers using below specification: + +Two 3-Node testbeds are constructed by connecting 6 Xeon servers using below +specification: + ``` - testbed31: - ring1 10GE-ports x710-4p10GE on SUTs: @@ -724,7 +804,10 @@ Two 3-Node testbeds are constructed by connecting 6 Xeon servers using below spe #### 1-Node Arm -One 1-Node testbed is constructed by connecting 1 Arm server using below specification: + +One 1-Node testbed is constructed by connecting 1 Arm server using below +specification: + ``` - testbed13: - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs: @@ -735,9 +818,11 @@ One 1-Node testbed is constructed by connecting 1 Arm server using below specifi - s27-t13-sut1-c6/p2 - s27-t13-sut1-c1/p1. ``` - #### 3-Node Arm -One 3-Node testbed is constructed by connecting 2 TaiShan servers and one Xeon server using below specification: + +One 3-Node testbed is constructed by connecting 2 TaiShan servers and one Xeon +server using below specification: + ``` - testbed33: - ring1 10GE-ports 82599-2p10GE on SUTs: @@ -749,7 +834,10 @@ One 3-Node testbed is constructed by connecting 2 TaiShan servers and one Xeon s - t33-sut1-c4/p1 - t33-sut2-c4/p2. - t33-sut2-c4/p1 - t33t34-tg1-c4/p1. ``` -One 3-Node testbed is constructed by connecting 2 MACCHIATObin servers and one Xeon server using below specification: + +One 3-Node testbed is constructed by connecting 2 MACCHIATObin servers and one +Xeon server using below specification: + ``` - testbed34: - ring1 10GE-ports Marvell on SUTs: @@ -759,7 +847,10 @@ One 3-Node testbed is constructed by connecting 2 MACCHIATObin servers and one X ``` #### TCP/IP and L47 -One 2-Node TCP/IP testbed is constructed by connecting Ixia PSOne and 1 Xeon server using below specification: + +One 2-Node TCP/IP testbed is constructed by connecting Ixia PSOne and 1 Xeon +server using below specification: + ``` - testbed25: - link1 10GE-port x710-4p10GE on SUT: @@ -773,13 +864,19 @@ One 2-Node TCP/IP testbed is constructed by connecting Ixia PSOne and 1 Xeon ser ``` #### 3-Node Atom + .. ## Server Specification + ### Hardware Configuration -The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware server configurations: + +The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware +server configurations: + ``` -1. Type-1: Purpose - (Intel Xeon Processor) SUT for SW Data Plane Workload i.e. VPP, testpmd. +1. Type-1: Purpose - (Intel Xeon Processor) SUT for SW Data Plane Workload i.e. + VPP, testpmd. - Quantity: TBD based on testbed allocation. - Physical connectivity: - IPMI and host management ports. @@ -819,7 +916,8 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: x710-4p10GE Intel. -3. Type-3: Purpose - (Arm hip07-d05 Processor) SUT for SW Data Plane Workload i.e. VPP, testpmd. +3. Type-3: Purpose - (Arm hip07-d05 Processor) SUT for SW Data Plane Workload + i.e. VPP, testpmd. - Quantity: 2 - Physical connectivity: - IPMI(?) and host management ports. @@ -832,7 +930,8 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware - NICs configuration: - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox. - PCIe Slot6 11:00.xx: 82599-2p10GE Intel. -4. Type-4: Purpose - (Arm Armada 8040 Processor) SUT for SW Data Plane Workload i.e. VPP, testpmd. +4. Type-4: Purpose - (Arm Armada 8040 Processor) SUT for SW Data Plane Workload + i.e. VPP, testpmd. - Quantity: 3 - Physical connectivity: - Host management ports. @@ -844,7 +943,8 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware - Disks: 1* 128GB(?) SATA SDD - NICs configuration: - pp2-2p10GE Marvell (on-chip Ethernet ports ; marvell plugin in VPP) -5. Type-5: Purpose - (Intel Atom Processor) SUT for SW Data Plane Workload i.e. VPP, testpmd. +5. Type-5: Purpose - (Intel Atom Processor) SUT for SW Data Plane Workload i.e. + VPP, testpmd. - Quantity: TBD based on testbed allocation. - Physical connectivity: - Management: serial Port (usb) for console @@ -877,7 +977,8 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -7. Type-7: Purpose - Ixia PerfectStorm One Appliance TG for TCP/IP performance tests. +7. Type-7: Purpose - Ixia PerfectStorm One Appliance TG for TCP/IP performance + tests. - Quantity: 1. - Physical connectivity: - Host management interface: 10/100/1000-BaseT. @@ -916,7 +1017,8 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -9. Type-9: Purpose - (Marvell ThunderX2 Processor) SUT for VPP_Device functional tests. +9. Type-9: Purpose - (Marvell ThunderX2 Processor) SUT for VPP_Device functional + tests. - Quantity: 1 - Physical connectivity: - IPMI and host management ports. @@ -933,7 +1035,8 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware - PCIe Slot3 08:00.xx: XL710-QDA2. - Numa1: - PCIe Slot6 85:00.xx: XL710-QDA2. -10. Type-10: Purpose - (Intel Atom C3000 Processor) SUT for SW Data Plane Workload i.e. VPP, testpmd. +10. Type-10: Purpose - (Intel Atom C3000 Processor) SUT for SW Data Plane + Workload i.e. VPP, testpmd. - Quantity: 4 - Physical connectivity: - IPMI and host management ports. @@ -950,7 +1053,9 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware ``` ### Xeon Skx Server BIOS Configuration + #### Boot Feature + ``` | Quiet Boot [Enabled] |Boot option | | | | @@ -970,6 +1075,7 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware ``` #### CPU Configuration + ``` | Processor Configuration |Enables Hyper Threading | | -------------------------------------------------- |(Software Method to | @@ -1004,6 +1110,7 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware ``` ##### Advanced Power Management Configuration + ``` | Advanced Power Management Configuration |Switch CPU Power Management | | -------------------------------------------------- |profile | @@ -1018,6 +1125,7 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware ``` ###### CPU P State Control + ``` | CPU P State Control |Enable/Disable EIST | | |(P-States) | @@ -1026,6 +1134,7 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware ``` ###### Hardware PM State Control + ``` | Hardware PM State Control |Disable: Hardware chooses a | | |P-state based on OS Request | @@ -1039,6 +1148,7 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware ``` ###### CPU C State Control + ``` | CPU C State Control |Autonomous Core C-State | | |Control | @@ -1048,6 +1158,7 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware ``` ###### Package C State Control + ``` | Package C State Control |Package C State limit | | | | @@ -1055,6 +1166,7 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware ``` ###### CPU T State Control + ``` | CPU T State Control |Enable/Disable Software | | |Controlled T-States | @@ -1062,6 +1174,7 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware ``` ##### Chipset Configuration + ``` | WARNING: Setting wrong values in below sections may cause |North Bridge Parameters | | system to malfunction. | | @@ -1070,6 +1183,7 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware ``` ###### North Bridge + ``` |> UPI Configuration |Displays and provides | |> Memory Configuration |option to change the UPI | @@ -1077,6 +1191,7 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware ``` ###### UPI Configuration + ``` | UPI Configuration |Choose Topology Precedence | | -------------------------------------------------- |to degrade features if | @@ -1101,6 +1216,7 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware ``` ###### Memory Configuration + ``` | |POR - Enforces Plan Of | | -------------------------------------------------- |Record restrictions for | @@ -1121,6 +1237,7 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware ``` ###### IIO Configuration + ``` | IIO Configuration |Expose IIO DFX devices and | | -------------------------------------------------- |other CPU devices like PMON | @@ -1138,6 +1255,7 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware ``` ###### CPU1 Configuration + ``` | IOU0 (IIO PCIe Br1) [Auto] |Selects PCIe port | | IOU1 (IIO PCIe Br2) [Auto] |Bifurcation for selected | @@ -1148,6 +1266,7 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware ``` ###### CPU2 Configuration + ``` | IOU0 (IIO PCIe Br1) [Auto] |Selects PCIe port | | IOU1 (IIO PCIe Br2) [Auto] |Bifurcation for selected | @@ -1158,6 +1277,7 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware ``` ##### South Bridge + ``` | |Enables Legacy USB support. | | USB Module Version 17 |AUTO option disables legacy | @@ -1177,6 +1297,7 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware ``` #### PCIe/PCI/PnP Configuration + ``` | PCI Bus Driver Version A5.01.12 |Enables or Disables 64bit | | |capable Devices to be | @@ -1204,6 +1325,7 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware ``` #### ACPI Settings + ``` | ACPI Settings |Enable or Disable Non | | |uniform Memory Access | @@ -1214,6 +1336,7 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware ``` #### DMIDECODE + ``` # dmidecode 3.1 Getting SMBIOS data from sysfs. @@ -1414,6 +1537,7 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware ``` ### Xeon Skx Server Firmware Inventory + ``` Host. IPMI IP. BIOS. CPLD. Aptio SU. CPU Microcode. PCI Bus. ME Operation FW. X710 Firmware. XXV710 Firmware. i40e. s1-t11-sut1. 10.30.50.47. 2.1. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k. |