aboutsummaryrefslogtreecommitdiffstats
path: root/docs/lab/testbed_specifications.md
diff options
context:
space:
mode:
Diffstat (limited to 'docs/lab/testbed_specifications.md')
-rw-r--r--docs/lab/testbed_specifications.md327
1 files changed, 31 insertions, 296 deletions
diff --git a/docs/lab/testbed_specifications.md b/docs/lab/testbed_specifications.md
index 7d4f0e001a..b52ada8660 100644
--- a/docs/lab/testbed_specifications.md
+++ b/docs/lab/testbed_specifications.md
@@ -12,7 +12,6 @@
1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2)
- 1. [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx)
1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
@@ -30,12 +29,11 @@
1. [1-Node-ThunderX2 Servers (1n-tx2) PROD](#1-node-thunderx2-servers-1n-tx2-prod)
1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod)
1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
- 1. [2-Node-Denverton Servers (2n-dnv) TODO](#2-node-denverton-servers-2n-dnv-todo)
+ 1. [2-Node-Denverton Servers (2n-dnv) PROD](#2-node-denverton-servers-2n-dnv-prod)
1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod)
1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod])
- 1. [2-Node-ThunderX2 Servers (2n-tx2) WIP](#2-node-thunderx2-servers-2n-tx2-wip)
- 1. [3-Node-Haswell Servers (3n-hsw) PROD](#3-node-haswell-servers-3n-hsw-prod)
+ 1. [2-Node-ThunderX2 Servers (2n-tx2) PROD](#2-node-thunderx2-servers-2n-tx2-prod)
1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod)
@@ -44,11 +42,11 @@
1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod)
1. [1-Node-Cascadelake Wiring (1n-clx) PROD](#1-node-cascadelake-wiring-1n-clx-prod)
1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
- 1. [2-Node-Denverton Wiring (2n-dnv) TODO](#2-node-denverton-wiring-2n-dnv-todo)
+ 1. [2-Node-Denverton Wiring (2n-dnv) PROD](#2-node-denverton-wiring-2n-dnv-prod)
1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod])
- 1. [2-Node-ThunderX2 Wiring (2n-tx2) WIP](#2-node-thunderx2-wiring-2n-tx2-wip)
+ 1. [2-Node-ThunderX2 Wiring (2n-tx2) PROD](#2-node-thunderx2-wiring-2n-tx2-prod)
1. [3-Node-Haswell Wiring (3n-hsw) PROD](#3-node-haswell-wiring-3n-hsw-prod)
1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo)
@@ -72,7 +70,7 @@ hosted by LFN FD.io CSIT project.
```
#. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #clx #zn2
- 1. 1-Node-VIRL dev hsw --- 3 3 0 3 0 0 0 0 0 0 0 0
+ 1. 1-Node-Haswell nomad hsw --- 4 4 0 4 0 0 0 0 0 0 0 0
2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0 0
3. 1-Node-ThunderX2 perf tx2 na 1 1 .5 0 .5 0 0 0 1 0 0 0
4. 1-Node-ThunderX2 dev tx2 na 2 2 0 0 0 0 0 0 2 0 0 0
@@ -81,13 +79,12 @@ hosted by LFN FD.io CSIT project.
7. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0 0
8. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0 0
9. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 6 0
-10. 3-Node-Haswell perf hsw hsw 3 6 3 9 0 0 0 0 0 0 0 0
-11. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 0
-12. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 0
-13. 3-Node-Taishan perf tsh skx 1 2 .5 0 .5 0 0 0 0 2 0 0
-14. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0 0
-15. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 0 2
- Totals: 27 36 18 12 19 1 2 3 3 2 7 2
+10. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 0
+11. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 0
+12. 3-Node-Taishan perf tsh skx 1 2 .5 0 .5 0 0 0 0 2 0 0
+13. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0 0
+14. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 0 2
+ Totals: 25 31 15 4 19 1 2 3 3 2 7 2
```
### 1-Node-Skylake Xeon Intel (1n-skx)
@@ -236,15 +233,6 @@ Name | Comment
10.30.50.13 | LF Reserved
10.30.50.14 | LF Reserved
10.30.50.15 | LF Reserved
-10.30.50.16 | t1-tg1
-10.30.50.17 | t1-sut1
-10.30.50.18 | t1-sut2
-10.30.50.20 | t2-tg1
-10.30.50.21 | t2-sut1
-10.30.50.22 | t2-sut2
-10.30.50.24 | t3-tg1
-10.30.50.25 | t3-sut1
-10.30.50.26 | t3-sut-2
10.30.50.28 | s41-nomad
10.30.50.29 | s39-nomad
10.30.51.29 | s22-t35-sut1 screen -r /dev/ttyusb0
@@ -322,22 +310,7 @@ Name | Comment
10.30.51.6 | LF Reserved
10.30.51.7 | LF Reserved
10.30.51.8 | LF Reserved
-10.30.51.9 | s22-t35-sut1 (netgate-1)
-10.30.51.10 | s23-t35-sut2 (netgate-2)
-10.30.51.11 | s24-t35-sut3 (netgate-3)
-10.30.51.12 | softiron-1 (decommissioned)
-10.30.51.13 | softiron-2 (decommissioned)
-10.30.51.14 | softiron-3 (decommissioned)
10.30.51.15 | LF Reserved
-10.30.51.16 | t1-tg1
-10.30.51.17 | t1-sut1
-10.30.51.18 | t1-sut2
-10.30.51.20 | t2-tg1
-10.30.51.21 | t2-sut1
-10.30.51.22 | t2-sut2
-10.30.51.24 | t3-tg1
-10.30.51.25 | t3-sut1
-10.30.51.26 | t3-sut-2
10.30.51.28 | s41-nomad
10.30.51.29 | s39-nomad
10.30.51.30 | s40-nomad
@@ -350,9 +323,6 @@ Name | Comment
10.30.51.38 | fdio-marvell-dev
10.30.51.39 | s53-nomad
10.30.51.40 | s54-nomad
-10.30.51.41 | s20-t34-sut1 (decommissioned)
-10.30.51.42 | s21-t34-sut2 (decommissioned)
-10.30.51.43 | fdio-mcbin3 (decommissioned)
10.30.51.44 | s3-t21-sut1
10.30.51.45 | s4-t21-tg1
10.30.51.46 | s11-t31-sut1
@@ -379,9 +349,7 @@ Name | Comment
10.30.51.69 | s27-t34-sut1
10.30.51.70 | s55-t36-sut1
10.30.51.71 | s56-t37-sut1
-10.30.51.72-10.30.51.105 | FREE
-10.30.51.106-10.30.51.180 | FREE
-10.30.51.181-10.30.51.254 | FREE
+10.30.51.72-10.30.51.254 | FREE
10.30.51.255 | Broadcast
10.32.8.0 | network
10.32.8.1 | Router
@@ -421,13 +389,13 @@ FD.io CSIT lab contains following server types:
- Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
- NICs configuration:
- Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
- - PCIe Slot1: Cisco VIC 1385 2p40GE.
- - PCIe Slot2: Intel NIC x520 2p10GE.
+ - PCIe Slot1: empty.
+ - PCIe Slot2: empty.
- PCIe Slot3: empty.
- Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
- - PCIe Slot4: Intel NIC xl710 2p40GE.
- - PCIe Slot5: Intel NIC x710 2p10GE.
- - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill)
+ - PCIe Slot4: empty.
+ - PCIe Slot5: empty.
+ - PCIe Slot6: empty
- MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
- Quantity: 3 servers.
@@ -440,14 +408,14 @@ FD.io CSIT lab contains following server types:
- RAM Memory: 16* 32GB DDR4-2133MHz.
- Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
- NICs configuration:
- - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
- - PCIe Slot1: Intel NIC xl710 2p40GE.
- - PCIe Slot2: Intel NIC x710 2p10GE.
- - PCIe Slot3: Intel NIC x710 2p10GE.
- - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
- - PCIe Slot4: Intel NIC xl710 2p40GE.
- - PCIe Slot5: Intel NIC x710 2p10GE.
- - PCIe Slot6: Intel NIC x710 2p10GE.
+ - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
+ - PCIe Slot1: empty.
+ - PCIe Slot2: empty.
+ - PCIe Slot3: empty.
+ - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
+ - PCIe Slot4: empty.
+ - PCIe Slot5: empty.
+ - PCIe Slot6: empty
- MLOM slot: empty.
3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
- Quantity: 3 servers.
@@ -735,7 +703,6 @@ FD.io CSIT lab contains following server types:
- no cards.
- Numa1:
- no cards.
-
19. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
- Quantity: 1.
- Physical connectivity:
@@ -979,7 +946,7 @@ connectivity and wiring across defined CSIT testbeds:
- s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
```
-#### 2-Node-Denverton Servers (2n-dnv) WIP
+#### 2-Node-Denverton Servers (2n-dnv) PROD
Note: ServerB28 (TG) is shared between testbed26 & testbed35
@@ -1173,7 +1140,7 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35
- s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
```
-#### 2-Node-ThunderX2 Servers (2x-tx2) WIP
+#### 2-Node-ThunderX2 Servers (2x-tx2) PROD
Note: Server19 (TG) is shared between testbed33 & testbed34
@@ -1208,161 +1175,6 @@ Note: Server19 (TG) is shared between testbed33 & testbed34
- s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
```
-#### 3-Node-Haswell Servers (3n-hsw) PROD
-
-```
- 1. SUT [Server-Type-A1]:
- - testbedname: testbed1.
- - hostname: t1-sut1.
- - CIMC IP: 10.30.50.17
- - Host IP: 10.30.51.17
- - portnames:
- - t1-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
- - t1-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
- - t1-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
- - t1-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
- - t1-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t1-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t1-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
- - t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 2. SUT [Server-Type-A1]:
- - testbedname: testbed1.
- - hostname: t1-sut2.
- - CIMC IP: 10.30.50.18
- - Host IP: 10.30.51.18
- - portnames:
- - t1-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
- - t1-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
- - t1-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
- - t1-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
- - t1-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t1-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t1-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
- - t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 3. TG [Server-Type-A2]:
- - testbedname: testbed1.
- - hostname: t1-tg1.
- - CIMC IP: 10.30.50.16
- - Host IP: 10.30.51.16
- - portnames:
- - t1-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t1-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t1-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t1-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t1-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t1-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t1-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t1-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t1-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- 4. SUT [Server-Type-A1]:
- - testbedname: testbed2.
- - hostname: t2-sut1.
- - CIMC IP: 10.30.50.21
- - Host IP: 10.30.51.21
- - portnames:
- - t2-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
- - t2-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
- - t2-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
- - t2-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
- - t2-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t2-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t2-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
- - t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 5. SUT [Server-Type-A1]:
- - testbedname: testbed2.
- - hostname: t2-sut2.
- - CIMC IP: 10.30.50.22
- - Host IP: 10.30.51.22
- - portnames:
- - t2-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
- - t2-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
- - t2-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
- - t2-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
- - t2-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t2-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t2-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
- - t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 6. TG [Server-Type-A2]:
- - testbedname: testbed2.
- - hostname: t2-tg1.
- - CIMC IP: 10.30.50.20
- - Host IP: 10.30.51.20
- - portnames:
- - t2-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t2-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t2-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t2-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t2-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t2-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t2-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t2-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t2-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- 7. SUT [Server-Type-A1]:
- - testbedname: testbed3.
- - hostname: t3-sut1.
- - CIMC IP: 10.30.50.25
- - Host IP: 10.30.51.25
- - portnames:
- - t3-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
- - t3-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
- - t3-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
- - t3-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
- - t3-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t3-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t3-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
- - t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 8. SUT [Server-Type-A1]:
- - testbedname: testbed3.
- - hostname: t3-sut2.
- - CIMC IP: 10.30.50.26
- - Host IP: 10.30.51.26
- - portnames:
- - t3-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
- - t3-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
- - t3-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
- - t3-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
- - t3-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t3-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t3-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
- - t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 9. TG [Server-Type-A2]:
- - testbedname: testbed3.
- - hostname: t3-tg1.
- - CIMC IP: 10.30.50.24
- - Host IP: 10.30.51.24
- - portnames:
- - t3-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t3-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t3-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t3-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t3-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t3-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t3-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t3-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t3-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t3-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t3-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t3-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-```
-
#### 3-Node-Skylake Servers (3n-skx) PROD
```
@@ -1531,7 +1343,7 @@ Note: Server19 (TG) is shared between testbed33 & testbed34
- s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
```
-#### 3-Node-Denverton Servers (3n-dnv) WIP
+#### 3-Node-Denverton Servers (3n-dnv) PROD
```
- ServerB30 [Server-Type-B10]:
@@ -1664,7 +1476,7 @@ Note: Server19 (TG) is shared between testbed33 & testbed34
- s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
```
-#### 2-Node-Denverton Wiring (2n-dnv) WIP
+#### 2-Node-Denverton Wiring (2n-dnv) PROD
```
- testbed26:
@@ -1761,7 +1573,7 @@ Note: Server19 (TG) is shared between testbed33 & testbed34
- s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
```
-#### 2-Node-ThunderX2 Wiring (2n-tx2) WIP
+#### 2-Node-ThunderX2 Wiring (2n-tx2) PROD
```
- testbed34:
@@ -1770,83 +1582,6 @@ Note: Server19 (TG) is shared between testbed33 & testbed34
- s27-t34-sut1-c18/p2 - s19-t33t34-tg1-c8/p2.
```
-
-#### 3-Node-Haswell Wiring (3n-hsw) PROD
-
-```
- 1. testbed1:
- - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
- - t1-tg1-c1/p1 to t1-sut1-c1/p2.
- - t1-sut1-c1/p1 to t1-sut2-c1/p2.
- - t1-sut2-c1/p1 to t1-tg1-c1/p2.
- - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
- - t1-tg1-c2/p1 to t1-sut1-c2/p2.
- - t1-sut1-c2/p1 to t1-sut2-c2/p2.
- - t1-sut2-c2/p1 to t1-tg1-c2/p2.
- - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
- - t1-tg1-c4/p1 to t1-sut1-c4/p2.
- - t1-sut1-c4/p1 to t1-sut2-c4/p2.
- - t1-sut2-c4/p1 to t1-tg1-c4/p2.
- - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
- - t1-tg1-c5/p1 to t1-sut1-c5/p2.
- - t1-sut1-c5/p1 to t1-sut2-c5/p2.
- - t1-sut2-c5/p1 to t1-tg1-c5/p2.
- - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
- - t1-tg1-c2/p1 to t1-sut1-cm/p2.
- - t1-sut1-cm/p1 to t1-sut2-cm/p2.
- - t1-sut2-cm/p1 to t1-tg1-c2/p2.
- - TG loopback ports Intel NIC x710 2p10GE
- - t1-tg1-c6/p1 to t1-tg1-c6/p2.
-
- 2. testbed2:
- - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
- - t2-tg1-c1/p1 to t2-sut1-c1/p2.
- - t2-sut1-c1/p1 to t2-sut2-c1/p2.
- - t2-sut2-c1/p1 to t2-tg1-c1/p2.
- - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
- - t2-tg1-c2/p1 to t2-sut1-c2/p2.
- - t2-sut1-c2/p1 to t2-sut2-c2/p2.
- - t2-sut2-c2/p1 to t2-tg1-c2/p2.
- - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
- - t2-tg1-c4/p1 to t2-sut1-c4/p2.
- - t2-sut1-c4/p1 to t2-sut2-c4/p2.
- - t2-sut2-c4/p1 to t2-tg1-c4/p2.
- - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
- - t2-tg1-c5/p1 to t2-sut1-c5/p2.
- - t2-sut1-c5/p1 to t2-sut2-c5/p2.
- - t2-sut2-c5/p1 to t2-tg1-c5/p2.
- - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
- - t2-tg1-c2/p1 to t2-sut1-cm/p2.
- - t2-sut1-cm/p1 to t2-sut2-cm/p2.
- - t2-sut2-cm/p1 to t2-tg1-c2/p2.
- - TG loopback ports Intel NIC x710 2p10GE
- - t2-tg1-c6/p1 to t2-tg1-c6/p2.
-
- 3. testbed3:
- - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
- - t3-tg1-c1/p1 to t3-sut1-c1/p2.
- - t3-sut1-c1/p1 to t3-sut2-c1/p2.
- - t3-sut2-c1/p1 to t3-tg1-c1/p2.
- - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
- - t3-tg1-c2/p1 to t3-sut1-c2/p2.
- - t3-sut1-c2/p1 to t3-sut2-c2/p2.
- - t3-sut2-c2/p1 to t3-tg1-c2/p2.
- - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
- - t3-tg1-c4/p1 to t3-sut1-c4/p2.
- - t3-sut1-c4/p1 to t3-sut2-c4/p2.
- - t3-sut2-c4/p1 to t3-tg1-c4/p2.
- - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
- - t3-tg1-c5/p1 to t3-sut1-c5/p2.
- - t3-sut1-c5/p1 to t3-sut2-c5/p2.
- - t3-sut2-c5/p1 to t3-tg1-c5/p2.
- - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
- - t3-tg1-c2/p1 to t3-sut1-cm/p2.
- - t3-sut1-cm/p1 to t3-sut2-cm/p2.
- - t3-sut2-cm/p1 to t3-tg1-c2/p2.
- - TG loopback ports Intel NIC x710 2p10GE
- - t3-tg1-c6/p1 to t3-tg1-c6/p2.
-```
-
#### 3-Node-Skylake Wiring (3n-skx) PROD
```
@@ -1912,7 +1647,7 @@ To be completed.
- s18-t33-sut2-c4/p1 - s19-t33t34-tg1-c4/p1.
```
-#### 3-Node-Denverton Wiring (3n-dnv) WIP
+#### 3-Node-Denverton Wiring (3n-dnv) PROD
```
- testbed35: