aboutsummaryrefslogtreecommitdiffstats
path: root/docs/lab/testbed_specifications.md
diff options
context:
space:
mode:
Diffstat (limited to 'docs/lab/testbed_specifications.md')
-rw-r--r--docs/lab/testbed_specifications.md323
1 files changed, 0 insertions, 323 deletions
diff --git a/docs/lab/testbed_specifications.md b/docs/lab/testbed_specifications.md
index 47c41c23d3..22dade917f 100644
--- a/docs/lab/testbed_specifications.md
+++ b/docs/lab/testbed_specifications.md
@@ -6,14 +6,12 @@
1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
- 1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2)
1. [2-Node-Icelake Xeon Intel (2n-icx)](#2-node-icelake-xeon-intel-2n-icx)
- 1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
1. [3-Node-Altra Arm Ampere (3n-alt)](#3-node-altra-arm-armpere-3n-alt)
@@ -32,14 +30,12 @@
1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
1. [1-Node-ThunderX2 Servers (1n-tx2) PROD](#1-node-thunderx2-servers-1n-tx2-prod)
1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod)
- 1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
1. [2-Node-Denverton Servers (2n-dnv) PROD](#2-node-denverton-servers-2n-dnv-prod)
1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod)
1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod])
1. [2-Node-ThunderX2 Servers (2n-tx2) PROD](#2-node-thunderx2-servers-2n-tx2-prod)
1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
- 1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod)
1. [3-Node-Altra Servers (3n-alt) PROD](#3-node-altra-servers-3n-alt-prod)
@@ -49,14 +45,12 @@
1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod)
1. [1-Node-Cascadelake Wiring (1n-clx) PROD](#1-node-cascadelake-wiring-1n-clx-prod)
- 1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
1. [2-Node-Denverton Wiring (2n-dnv) PROD](#2-node-denverton-wiring-2n-dnv-prod)
1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod])
1. [2-Node-ThunderX2 Wiring (2n-tx2) PROD](#2-node-thunderx2-wiring-2n-tx2-prod)
1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
- 1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
1. [3-Node-Rangeley Wiring (3n-rng) VERIFY](#3-node-rangeley-wiring-3n-rng-todo)
1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod)
1. [3-Node-Altra Wiring (3n-alt) PROD](#3-node-altra-wiring-3n-alt-prod)
@@ -122,13 +116,6 @@ NIC ports connected back-to-back ([Server Types](#server-types)).
Used for FD.io VPP_Device functional driver tests.
-### 2-Node-Skylake Xeon Intel (2n-skx)
-
-Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
-(Server-Type-B2) connected in a 2-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
### 2-Node-Denverton Atom Intel (2n-dnv)
Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
@@ -178,12 +165,6 @@ TG (Server-Type-A2) connected in a 3-node circular topology
([Server Types](#server-types)).
Used for FD.io performance tests.
-### 3-Node-Skylake Xeon Intel (3n-skx)
-
-Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
-TG (Server-Type-B2) connected in a 3-node circular topology.
-Used for FD.io performance tests.
-
### 3-Node-Rangeley Atom Testbeds
Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
@@ -1039,123 +1020,6 @@ connectivity and wiring across defined CSIT testbeds:
- s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
```
-#### 2-Node-Skylake Servers (2n-skx) PROD
-
-```
-- SUT [Server-Type-B1]:
- - testbedname: testbed21.
- - hostname: s3-t21-sut1.
- - IPMI IP: 10.30.50.41
- - Host IP: 10.30.51.44
- - portnames:
- - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- TG [Server-Type-B2]:
- - testbedname: testbed21.
- - hostname: s4-t21-tg1.
- - IPMI IP: 10.30.50.42
- - Host IP: 10.30.51.45
- - portnames:
- - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s3-t21-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
- - s3-t21-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
- - s3-t21-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
- - s3-t21-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
-- SUT [Server-Type-B1]:
- - testbedname: testbed22.
- - hostname: s5-t22-sut1.
- - IPMI IP: 10.30.50.49
- - Host IP: 10.30.51.52
- - portnames:
- - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- TG [Server-Type-B2]:
- - testbedname: testbed22.
- - hostname: s6-t22-tg1.
- - IPMI IP: 10.30.50.50
- - Host IP: 10.30.51.53
- - portnames:
- - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s6-t22-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
- - s6-t22-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
- - s6-t22-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
- - s6-t22-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
-- SUT [Server-Type-B1]:
- - testbedname: testbed23.
- - hostname: s7-t23-sut1.
- - IPMI IP: 10.30.50.51
- - Host IP: 10.30.51.54
- - portnames:
- - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- TG [Server-Type-B2]:
- - testbedname: testbed23.
- - hostname: s8-t23-tg1.
- - IPMI IP: 10.30.50.52
- - Host IP: 10.30.51.55
- - portnames:
- - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s8-t23-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
- - s8-t23-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
- - s8-t23-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
- - s8-t23-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
-- SUT [Server-Type-B1]:
- - testbedname: testbed24.
- - hostname: s9-t24-sut1.
- - IPMI IP: 10.30.50.53
- - Host IP: 10.30.51.56
- - portnames:
- - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- TG [Server-Type-B2]:
- - testbedname: testbed24.
- - hostname: s10-t24-tg1.
- - IPMI IP: 10.30.50.54
- - Host IP: 10.30.51.57
- - portnames:
- - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s10-t24-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
- - s10-t24-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
- - s10-t24-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
- - s10-t24-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
-```
-
#### 2-Node-Denverton Servers (2n-dnv) PROD
Note: ServerB28 (TG) is shared between testbed26 & testbed35
@@ -1512,91 +1376,6 @@ Note: Server19 (TG) is shared between testbed33 & testbed211
- s88-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
```
-#### 3-Node-Skylake Servers (3n-skx) PROD
-
-```
-- ServerB11 [Server-Type-B1]:
- - testbedname: testbed31.
- - hostname: s11-t31-sut1.
- - IPMI IP: 10.30.50.43
- - Host IP: 10.30.51.46
- - portnames:
- - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- ServerB12 [Server-Type-B1]:
- - testbedname: testbed31.
- - hostname: s12-t31-sut2.
- - IPMI IP: 10.30.50.44
- - Host IP: 10.30.51.47
- - portnames:
- - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
- - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
- - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
- - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
- - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- ServerB13 [Server-Type-B2]:
- - testbedname: testbed31.
- - hostname: s13-t31-tg1.
- - IPMI IP: 10.30.50.45
- - Host IP: 10.30.51.48
- - portnames:
- - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s13-t31-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
- - s13-t31-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
- - s13-t31-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
- - s13-t31-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
-- ServerB14 [Server-Type-B1]:
- - testbedname: testbed32.
- - hostname: s14-t32-sut1.
- - IPMI IP: 10.30.50.55
- - Host IP: 10.30.51.58
- - portnames:
- - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- ServerB15 [Server-Type-B1]:
- - testbedname: testbed32.
- - hostname: s15-t32-sut2.
- - IPMI IP: 10.30.50.56
- - Host IP: 10.30.51.59
- - portnames:
- - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
- - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
- - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
- - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
- - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- ServerB16 [Server-Type-B2]:
- - testbedname: testbed32.
- - hostname: s16-t32-tg1.
- - IPMI IP: 10.30.50.57
- - Host IP: 10.30.51.60
- - portnames:
- - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s16-t32-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
- - s16-t32-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
- - s16-t32-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
- - s16-t32-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
-```
-
#### 3-Node-Rangeley Servers (3n-rng) VERIFY
Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
@@ -1919,63 +1698,6 @@ Note: Server19 (TG) is shared between testbed33 & testbed211
- s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2.
```
-#### 2-Node-Skylake Wiring (2n-skx) PROD
-
-```
-- testbed21:
- - ring1 10GE-ports x710-4p10GE on SUT:
- - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
- - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
- - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
- - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
- - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
- - s4-t21-tg1-c10/p1 to s4-t21-tg1-c10/p2.
- - s4-t21-tg1-c10/p3 to s4-t21-tg1-c10/p4.
-- testbed22:
- - ring1 10GE-ports x710-4p10GE on SUT:
- - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
- - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
- - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
- - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
- - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
- - s6-t22-tg1-c10/p1 to s6-t22-tg1-c10/p2.
- - s6-t22-tg1-c10/p3 to s6-t22-tg1-c10/p4.
-- testbed23:
- - ring1 10GE-ports x710-4p10GE on SUT:
- - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
- - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
- - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
- - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
- - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
- - s8-t23-tg1-c10/p1 to s8-t23-tg1-c10/p2.
- - s8-t23-tg1-c10/p3 to s8-t23-tg1-c10/p4.
-- testbed24:
- - ring1 10GE-ports x710-4p10GE on SUT:
- - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
- - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
- - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
- - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
- - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
- - s10-t24-tg1-c10/p1 to s10-t24-tg1-c10/p2.
- - s10-t24-tg1-c10/p3 to s10-t24-tg1-c10/p4.
-```
-
#### 2-Node-Denverton Wiring (2n-dnv) PROD
```
@@ -2153,51 +1875,6 @@ Note: Server19 (TG) is shared between testbed33 & testbed211
- s88-t215-tg1-c6/p2 to s88-t215-tg1-c6/p1.
```
-#### 3-Node-Skylake Wiring (3n-skx) PROD
-
-```
-- testbed31:
- - ring1 10GE-ports x710-4p10GE on SUTs:
- - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
- - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
- - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
- - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
- - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
- - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
- - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
- - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
- - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
- - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
- - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
- - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
- - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
- - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
-- testbed32:
- - ring1 10GE-ports x710-4p10GE on SUTs:
- - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
- - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
- - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
- - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
- - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
- - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
- - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
- - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
- - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
- - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
- - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
- - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
- - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
- - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
-```
-
#### 3-Node-Rangeley Wiring (3n-rng) VERIFY
```