diff options
Diffstat (limited to 'docs/lab/testbed_specifications.md')
-rw-r--r-- | docs/lab/testbed_specifications.md | 89 |
1 files changed, 82 insertions, 7 deletions
diff --git a/docs/lab/testbed_specifications.md b/docs/lab/testbed_specifications.md index 5a8b4b1137..afa36ff56c 100644 --- a/docs/lab/testbed_specifications.md +++ b/docs/lab/testbed_specifications.md @@ -73,7 +73,8 @@ hosted by LFN FD.io CSIT project. 9. 3-Node-Taishan perf tsh skx 1 2 1 0 .5 0 0 0 0 2 0 10. 3-Node-Mcbin perf mcb skx 1 2 1 0 .5 0 0 0 0 0 2 11. 1-Node-VIRL func hsw --- 3 3 0 3 0 0 0 0 0 0 0 - Totals: 17 26 14 12 19 1 2 1 1 2 2 +12. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0 + Totals: 18 28 15 12 19 1 2 3 1 2 2 ``` ### 1-Node-Skylake Xeon Intel (1n-skx) @@ -716,10 +717,39 @@ connectivity and wiring across defined CSIT testbeds: - s10-t24-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. ``` -#### 2-Node-Denverton (2n-dnv) TODO +#### 2-Node-Denverton (2n-dnv) WIP + +Note: ServerB28 (TG) is shared between testbed26 & testbed35 ``` -To be completed. +- ServerB28 [Type-B2]: + - testbednames: testbed26 and testbed35. + - hostname: s28-t26t35-tg1. + - IPMI IP: 10.30.55.10 + - Host IP: 10.32.8.10 + - portnames: + - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE. + - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE. + - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE. + - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE. + - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE. + - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE. + - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE. + - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE. + - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE. + - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE. + - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE. + - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE. +- ServerB29 [Type-B10]: + - testbednames: testbed26. + - hostname: s29-t26-sut1. + - IPMI IP: 10.30.55.11 + - Host IP: 10.32.8.11 + - portnames: + - s29-t26-sut1-p1 - 10GE-port1 x553 copper port. + - s29-t26-sut1-p2 - 10GE-port2 x553 copper port. + - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port. + - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port. ``` #### 2-Node-IxiaPS1L47 (2n-ps1) VERIFY @@ -991,8 +1021,6 @@ To be completed. - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. ``` -Note: ServerB19 (TG) is shared between testbed33 & testbed34 - #### 3-Node-Rangeley (3n-rng) VERIFY Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. @@ -1029,6 +1057,8 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. #### 3-Node-Taishan (3n-tsh) WIP +Note: ServerB19 (TG) is shared between testbed33 & testbed34 + ``` - ServerB17 [Type-B3]: - testbedname: testbed33. @@ -1084,6 +1114,31 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s21-t34-sut2-ca/p2 - 10GE-port2 Marvell. ``` +#### 3-Node-Denverton (3n-dnv) WIP + +``` +- ServerB30 [Type-B10]: + - testbednames: testbed35. + - hostname: s30-t35-sut1. + - IPMI IP: 10.30.55.12 + - Host IP: 10.32.8.12 + - portnames: + - s30-t35-sut1-p1 - 10GE-port1 x553 copper port. + - s30-t35-sut1-p2 - 10GE-port2 x553 copper port. + - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port. + - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port. +- ServerB31 [Type-B10]: + - testbednames: testbed35. + - hostname: s31-t35-sut2. + - IPMI IP: 10.30.55.13 + - Host IP: 10.32.8.13 + - portnames: + - s31-t35-sut2-p1 - 10GE-port1 x553 copper port. + - s31-t35-sut2-p2 - 10GE-port2 x553 copper port. + - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port. + - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port. +``` + #### 3-Node-Mcbin (3n-mcb) TODO ``` @@ -1196,10 +1251,16 @@ To be completed. - s10-t24-tg1-c10/p3 to s10-t24-tg1-c10/p4. ``` -#### 2-Node-Denverton (2n-dnv) TODO +#### 2-Node-Denverton (2n-dnv) WIP ``` -To be completed. +- testbed26: + - ring1 10GE-ports x553 copper port on SUT: + - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1. + - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2. + - ring2 10GE-ports x553 fiber port on SUT: + - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3. + - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4. ``` #### 2-Node-IxiaPS1L47 (2n-ps1) VERIFY @@ -1367,6 +1428,20 @@ To be completed. - t34-sut2-ca/p2 - t33t34-tg1-c2/p4. ``` +#### 3-Node-Denverton (3n-dnv) WIP + +``` +- testbed35: + - ring1 10GE-ports x553 copper port on SUTs: + - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2. + - s30-t35-sut1-p1 to s31-t35-sut2-p1. + - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2. + - ring2 10GE-ports x553 fiber port on SUTs: + - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4. + - s30-t35-sut1-p3 to s31-t35-sut2-p3. + - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4. +``` + ## Inventory ### Appliances |