aboutsummaryrefslogtreecommitdiffstats
path: root/docs/lab
diff options
context:
space:
mode:
Diffstat (limited to 'docs/lab')
-rw-r--r--docs/lab/fdio-dc-inventory-vexxhost.md21
-rw-r--r--docs/lab/fdio-dc-physical.yaml89
-rw-r--r--docs/lab/testbed_specifications.md327
-rw-r--r--docs/lab/testbeds_ucs_hsw_hw_bios_cfg.md740
4 files changed, 50 insertions, 1127 deletions
diff --git a/docs/lab/fdio-dc-inventory-vexxhost.md b/docs/lab/fdio-dc-inventory-vexxhost.md
index 434a85a1cd..96990881e1 100644
--- a/docs/lab/fdio-dc-inventory-vexxhost.md
+++ b/docs/lab/fdio-dc-inventory-vexxhost.md
@@ -65,7 +65,6 @@ s7-t23-sut1,up,t23,2n-skx,SYS-7049GP-TRT,N/A,10.30.51.54,10.30.50.51,3016.10,u18
s8-t23-tg1,up,t23,2n-skx,SYS-7049GP-TRT,C7470KH06A20035,10.30.51.55,10.30.50.52,3016.10,u14-u17
s9-t24-sut1,up,t24,2n-skx,SYS-7049GP-TRT,C7470KH06A20055,10.30.51.56,10.30.50.53,3016.10,u10-u13
s10-t24-tg1,up,t24,2n-skx,SYS-7049GP-TRT,C7470KH06A20196,10.30.51.57,10.30.50.54,3016.10,u6-u9
-s43-nomad,up,nomad-cluster1,nomad-server,UCSC-C220-M3L,FCH1726V1M4,10.30.51.33,10.30.50.33,r3016.10,u5
#### Rack YUL1-11 (3016.11)
@@ -80,18 +79,10 @@ s56-t37-sut1,up,t37,2n-tx2,ThunderX2-9980,N/A,10.30.51.71,10.30.50.71,3016.11,u4
s41-nomad,up,nomad-cluster1,nomad-client,UCSC-C240-M4SX,FCH1950V1FQ,10.30.51.28,10.30.50.28,3016.11,u39-u40
s40-nomad,up,nomad-cluster1,nomad-server,UCSC-C240-M4SX,FCH2013V0HZ,10.30.51.30,10.30.50.30,3016.11,u37-u38
s39-nomad,up,nomad-cluster1,nomad-client,UCSC-C240-M4SX,FCH2013V0J2,10.30.51.29,10.30.50.29,3016.11,u35-u36
-s44-nomad,up,nomad-cluster1,nomad-client,UCSC-C220-M4S,FCH2139V129,10.30.51.34,10.30.50.34,3016.11,u34
-s45-nomad,up,nomad-cluster1,nomad-client,UCSC-C220-M4S,FCH2139V166,10.30.51.35,10.30.50.35,3016.11,u33
-s42-nomad,up,nomad-cluster1,nomad-server,UCSC-C240-M3S,FCH1719V18Y,10.30.51.32,10.30.50.32,3016.11,u31-u32
-t1-tg1,up,t1,3n-hsw,UCSC-C240-M4SX,FCH1950V1HM,10.30.51.16,10.30.50.16,3016.11,u29-u30
-t1-sut1,up,t1,3n-hsw,UCSC-C240-M4SX,FCH1950V1KH,10.30.51.17,10.30.50.17,3016.11,u27-u28
-t1-sut2,up,t1,3n-hsw,UCSC-C240-M4SX,FCH1950V1FP,10.30.51.18,10.30.50.18,3016.11,u25-u26
-t2-tg1,up,t2,3n-hsw,UCSC-C240-M4SX,FCH1950V1KG,10.30.51.20,10.30.50.20,3016.11,u23-u24
-t2-sut1,up,t2,3n-hsw,UCSC-C240-M4SX,FCH1950V1FM,10.30.51.21,10.30.50.21,3016.11,u21-u22
-t2-sut2,up,t2,3n-hsw,UCSC-C240-M4SX,FCH1950V1FN,10.30.51.22,10.30.50.22,3016.11,u19-u20
-t3-tg1,up,t3,3n-hsw,UCSC-C240-M4SX,FCH1950V1H5,10.30.51.24,10.30.50.24,3016.11,u17-u18
-t3-sut1,up,t3,3n-hsw,UCSC-C240-M4SX,FCH1950V1FS,10.30.51.25,10.30.50.25,3016.11,u15-u16
-t3-sut2,up,t3,3n-hsw,UCSC-C240-M4SX,FCH1950V1FL,10.30.51.26,10.30.50.26,3016.11,u13-u14
+s42-nomad,up,nomad-cluster1,nomad-server,UCSC-C240-M4SX,FCH1950V1FN,10.30.51.32,10.30.50.32,3016.11,u19-u20
+s43-nomad,up,nomad-cluster1,nomad-server,UCSC-C240-M4SX,FCH1950V1H5,10.30.51.33,10.30.50.33,3016.11,u17-u18
+s44-nomad,up,nomad-cluster1,nomad-client,UCSC-C240-M4SX,FCH1950V1FS,10.30.51.34,10.30.50.34,3016.11,u15-u16
+s45-nomad,up,nomad-cluster1,nomad-client,UCSC-C240-M4SX,FCH1950V1FL,10.30.51.35,10.30.50.35,3016.11,u13-u14
s55-t36-sut1,up,t36,1n-tx2,ThunderX2-9980,N/A,10.30.51.70,10.30.50.70,3016.11,u11-u12
s52-nomad,up,nomad-cluster1,nomad-client,ThunderX-88XX,N/A,10.30.51.65,10.30.50.65,3016.11,u9-u10
s51-nomad,up,nomad-cluster1,nomad-client,ThunderX-88XX,N/A,10.30.51.66,10.30.50.66,3016.11,u9-u10
@@ -128,4 +119,6 @@ Notes:
- softiron-1, softiron-2, softiron-3, decommission request and instructions issued
on 16-Sep-2020, per Vexxhost ticket
[#FDU-009676 - New arm hardware - 2xThunderX2](https://secure.vexxhost.com/billing/viewticket.php?tid=FDU-009676&c=ncHht136),
- search for "softiron". \ No newline at end of file
+ search for "softiron".
+- UCSC-C240-M4 EoL:
+ [End-of-Life Announcement for the Cisco Unified Computing System C-Series](https://www.cisco.com/c/en/us/products/collateral/servers-unified-computing/ucs-c-series-rack-servers/eos-eol-notice-c51-741235.html) \ No newline at end of file
diff --git a/docs/lab/fdio-dc-physical.yaml b/docs/lab/fdio-dc-physical.yaml
index 95ae428ad1..fc059fdcf8 100644
--- a/docs/lab/fdio-dc-physical.yaml
+++ b/docs/lab/fdio-dc-physical.yaml
@@ -183,13 +183,6 @@ yul1:
serial_number: C7470KH06A20196
mgmt_ip4: 10.30.51.57
lom_ip4: 10.30.50.54
- - unit: 5
- name: s43-nomad
- oper_status: production
- device_type: UCSC-C220-M3L
- serial_number: FCH1726V1M4
- mgmt_ip4: 10.30.51.33
- lom_ip4: 10.30.50.33
rack:
name: yul1-11
facility_id: 3016.11
@@ -269,92 +262,34 @@ yul1:
serial_number: FCH2013V0J2
mgmt_ip4: 10.30.51.29
lom_ip4: 10.30.50.29
- - unit: 34
- name: s44-nomad
- oper_status: production
- device_type: UCSC-C220-M4S
- serial_number: FCH2139V129
- mgmt_ip4: 10.30.51.34
- lom_ip4: 10.30.50.34
- lom_type: cimc
- - unit: 33
- name: s45-nomad
- oper_status: production
- device_type: UCSC-C220-M4S
- serial_number: FCH2139V166
- mgmt_ip4: 10.30.51.35
- lom_ip4: 10.30.50.35
- lom_type: cimc
- - unit: 31..32
- name: s42-nomad
- oper_status: production
- device_type: UCSC-C240-M3S
- serial_number: FCH1719V18Y
- mgmt_ip4: 10.30.51.32
- lom_ip4: 10.30.50.32
- - unit: 29..30
- name: t1-tg1
- oper_status: production
- device_type: UCSC-C240-M4S
- serial_number: FCH1950V1HM
- mgmt_ip4: 10.30.51.16
- lom_ip4: 10.30.50.16
- - unit: 27..28
- name: t1-sut1
- oper_status: production
- device_type: UCSC-C240-M4S
- serial_number: FCH1950V1KH
- mgmt_ip4: 10.30.51.17
- lom_ip4: 10.30.50.17
- - unit: 25..26
- name: t1-sut2
- oper_status: production
- device_type: UCSC-C240-M4S
- serial_number: FCH1950V1FP
- mgmt_ip4: 10.30.51.18
- lom_ip4: 10.30.50.18
- - unit: 23..24
- name: t2-tg1
- oper_status: production
- device_type: UCSC-C240-M4S
- serial_number: FCH1950V1KG
- mgmt_ip4: 10.30.51.20
- lom_ip4: 10.30.50.20
- - unit: 21..22
- name: t2-sut1
- oper_status: production
- device_type: UCSC-C240-M4S
- serial_number: FCH1950V1FM
- mgmt_ip4: 10.30.51.21
- lom_ip4: 10.30.50.21
- unit: 19..20
- name: t2-sut2
+ name: s42-nomad
oper_status: production
device_type: UCSC-C240-M4S
serial_number: FCH1950V1FN
- mgmt_ip4: 10.30.51.22
- lom_ip4: 10.30.50.22
+ mgmt_ip4: 10.30.51.32
+ lom_ip4: 10.30.50.32
- unit: 17..18
- name: t3-tg1
+ name: s43-nomad
oper_status: production
device_type: UCSC-C240-M4S
serial_number: FCH1950V1H5
- mgmt_ip4: 10.30.51.24
- lom_ip4: 10.30.50.24
+ mgmt_ip4: 10.30.51.33
+ lom_ip4: 10.30.50.33
- unit: 15..16
- name: t3-sut1
+ name: s44-nomad
oper_status: production
device_type: UCSC-C240-M4S
serial_number: FCH1950V1FS
- mgmt_ip4: 10.30.51.25
- lom_ip4: 10.30.50.25
+ mgmt_ip4: 10.30.51.34
+ lom_ip4: 10.30.50.34
- unit: 13..14
- name: t3-sut2
+ name: s45-nomad
oper_status: production
device_type: UCSC-C240-M4S
serial_number: FCH1950V1FL
- mgmt_ip4: 10.30.51.26
- lom_ip4: 10.30.50.26
+ mgmt_ip4: 10.30.51.35
+ lom_ip4: 10.30.50.35
- unit: 11..12
name: s55-t36-sut1
oper_status: production
diff --git a/docs/lab/testbed_specifications.md b/docs/lab/testbed_specifications.md
index 7d4f0e001a..b52ada8660 100644
--- a/docs/lab/testbed_specifications.md
+++ b/docs/lab/testbed_specifications.md
@@ -12,7 +12,6 @@
1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2)
- 1. [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx)
1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
@@ -30,12 +29,11 @@
1. [1-Node-ThunderX2 Servers (1n-tx2) PROD](#1-node-thunderx2-servers-1n-tx2-prod)
1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod)
1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
- 1. [2-Node-Denverton Servers (2n-dnv) TODO](#2-node-denverton-servers-2n-dnv-todo)
+ 1. [2-Node-Denverton Servers (2n-dnv) PROD](#2-node-denverton-servers-2n-dnv-prod)
1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod)
1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod])
- 1. [2-Node-ThunderX2 Servers (2n-tx2) WIP](#2-node-thunderx2-servers-2n-tx2-wip)
- 1. [3-Node-Haswell Servers (3n-hsw) PROD](#3-node-haswell-servers-3n-hsw-prod)
+ 1. [2-Node-ThunderX2 Servers (2n-tx2) PROD](#2-node-thunderx2-servers-2n-tx2-prod)
1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod)
@@ -44,11 +42,11 @@
1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod)
1. [1-Node-Cascadelake Wiring (1n-clx) PROD](#1-node-cascadelake-wiring-1n-clx-prod)
1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
- 1. [2-Node-Denverton Wiring (2n-dnv) TODO](#2-node-denverton-wiring-2n-dnv-todo)
+ 1. [2-Node-Denverton Wiring (2n-dnv) PROD](#2-node-denverton-wiring-2n-dnv-prod)
1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod])
- 1. [2-Node-ThunderX2 Wiring (2n-tx2) WIP](#2-node-thunderx2-wiring-2n-tx2-wip)
+ 1. [2-Node-ThunderX2 Wiring (2n-tx2) PROD](#2-node-thunderx2-wiring-2n-tx2-prod)
1. [3-Node-Haswell Wiring (3n-hsw) PROD](#3-node-haswell-wiring-3n-hsw-prod)
1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo)
@@ -72,7 +70,7 @@ hosted by LFN FD.io CSIT project.
```
#. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #clx #zn2
- 1. 1-Node-VIRL dev hsw --- 3 3 0 3 0 0 0 0 0 0 0 0
+ 1. 1-Node-Haswell nomad hsw --- 4 4 0 4 0 0 0 0 0 0 0 0
2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0 0
3. 1-Node-ThunderX2 perf tx2 na 1 1 .5 0 .5 0 0 0 1 0 0 0
4. 1-Node-ThunderX2 dev tx2 na 2 2 0 0 0 0 0 0 2 0 0 0
@@ -81,13 +79,12 @@ hosted by LFN FD.io CSIT project.
7. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0 0
8. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0 0
9. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 6 0
-10. 3-Node-Haswell perf hsw hsw 3 6 3 9 0 0 0 0 0 0 0 0
-11. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 0
-12. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 0
-13. 3-Node-Taishan perf tsh skx 1 2 .5 0 .5 0 0 0 0 2 0 0
-14. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0 0
-15. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 0 2
- Totals: 27 36 18 12 19 1 2 3 3 2 7 2
+10. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 0
+11. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 0
+12. 3-Node-Taishan perf tsh skx 1 2 .5 0 .5 0 0 0 0 2 0 0
+13. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0 0
+14. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 0 2
+ Totals: 25 31 15 4 19 1 2 3 3 2 7 2
```
### 1-Node-Skylake Xeon Intel (1n-skx)
@@ -236,15 +233,6 @@ Name | Comment
10.30.50.13 | LF Reserved
10.30.50.14 | LF Reserved
10.30.50.15 | LF Reserved
-10.30.50.16 | t1-tg1
-10.30.50.17 | t1-sut1
-10.30.50.18 | t1-sut2
-10.30.50.20 | t2-tg1
-10.30.50.21 | t2-sut1
-10.30.50.22 | t2-sut2
-10.30.50.24 | t3-tg1
-10.30.50.25 | t3-sut1
-10.30.50.26 | t3-sut-2
10.30.50.28 | s41-nomad
10.30.50.29 | s39-nomad
10.30.51.29 | s22-t35-sut1 screen -r /dev/ttyusb0
@@ -322,22 +310,7 @@ Name | Comment
10.30.51.6 | LF Reserved
10.30.51.7 | LF Reserved
10.30.51.8 | LF Reserved
-10.30.51.9 | s22-t35-sut1 (netgate-1)
-10.30.51.10 | s23-t35-sut2 (netgate-2)
-10.30.51.11 | s24-t35-sut3 (netgate-3)
-10.30.51.12 | softiron-1 (decommissioned)
-10.30.51.13 | softiron-2 (decommissioned)
-10.30.51.14 | softiron-3 (decommissioned)
10.30.51.15 | LF Reserved
-10.30.51.16 | t1-tg1
-10.30.51.17 | t1-sut1
-10.30.51.18 | t1-sut2
-10.30.51.20 | t2-tg1
-10.30.51.21 | t2-sut1
-10.30.51.22 | t2-sut2
-10.30.51.24 | t3-tg1
-10.30.51.25 | t3-sut1
-10.30.51.26 | t3-sut-2
10.30.51.28 | s41-nomad
10.30.51.29 | s39-nomad
10.30.51.30 | s40-nomad
@@ -350,9 +323,6 @@ Name | Comment
10.30.51.38 | fdio-marvell-dev
10.30.51.39 | s53-nomad
10.30.51.40 | s54-nomad
-10.30.51.41 | s20-t34-sut1 (decommissioned)
-10.30.51.42 | s21-t34-sut2 (decommissioned)
-10.30.51.43 | fdio-mcbin3 (decommissioned)
10.30.51.44 | s3-t21-sut1
10.30.51.45 | s4-t21-tg1
10.30.51.46 | s11-t31-sut1
@@ -379,9 +349,7 @@ Name | Comment
10.30.51.69 | s27-t34-sut1
10.30.51.70 | s55-t36-sut1
10.30.51.71 | s56-t37-sut1
-10.30.51.72-10.30.51.105 | FREE
-10.30.51.106-10.30.51.180 | FREE
-10.30.51.181-10.30.51.254 | FREE
+10.30.51.72-10.30.51.254 | FREE
10.30.51.255 | Broadcast
10.32.8.0 | network
10.32.8.1 | Router
@@ -421,13 +389,13 @@ FD.io CSIT lab contains following server types:
- Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
- NICs configuration:
- Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
- - PCIe Slot1: Cisco VIC 1385 2p40GE.
- - PCIe Slot2: Intel NIC x520 2p10GE.
+ - PCIe Slot1: empty.
+ - PCIe Slot2: empty.
- PCIe Slot3: empty.
- Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
- - PCIe Slot4: Intel NIC xl710 2p40GE.
- - PCIe Slot5: Intel NIC x710 2p10GE.
- - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill)
+ - PCIe Slot4: empty.
+ - PCIe Slot5: empty.
+ - PCIe Slot6: empty
- MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
- Quantity: 3 servers.
@@ -440,14 +408,14 @@ FD.io CSIT lab contains following server types:
- RAM Memory: 16* 32GB DDR4-2133MHz.
- Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
- NICs configuration:
- - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
- - PCIe Slot1: Intel NIC xl710 2p40GE.
- - PCIe Slot2: Intel NIC x710 2p10GE.
- - PCIe Slot3: Intel NIC x710 2p10GE.
- - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
- - PCIe Slot4: Intel NIC xl710 2p40GE.
- - PCIe Slot5: Intel NIC x710 2p10GE.
- - PCIe Slot6: Intel NIC x710 2p10GE.
+ - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
+ - PCIe Slot1: empty.
+ - PCIe Slot2: empty.
+ - PCIe Slot3: empty.
+ - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
+ - PCIe Slot4: empty.
+ - PCIe Slot5: empty.
+ - PCIe Slot6: empty
- MLOM slot: empty.
3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
- Quantity: 3 servers.
@@ -735,7 +703,6 @@ FD.io CSIT lab contains following server types:
- no cards.
- Numa1:
- no cards.
-
19. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
- Quantity: 1.
- Physical connectivity:
@@ -979,7 +946,7 @@ connectivity and wiring across defined CSIT testbeds:
- s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
```
-#### 2-Node-Denverton Servers (2n-dnv) WIP
+#### 2-Node-Denverton Servers (2n-dnv) PROD
Note: ServerB28 (TG) is shared between testbed26 & testbed35
@@ -1173,7 +1140,7 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35
- s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
```
-#### 2-Node-ThunderX2 Servers (2x-tx2) WIP
+#### 2-Node-ThunderX2 Servers (2x-tx2) PROD
Note: Server19 (TG) is shared between testbed33 & testbed34
@@ -1208,161 +1175,6 @@ Note: Server19 (TG) is shared between testbed33 & testbed34
- s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
```
-#### 3-Node-Haswell Servers (3n-hsw) PROD
-
-```
- 1. SUT [Server-Type-A1]:
- - testbedname: testbed1.
- - hostname: t1-sut1.
- - CIMC IP: 10.30.50.17
- - Host IP: 10.30.51.17
- - portnames:
- - t1-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
- - t1-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
- - t1-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
- - t1-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
- - t1-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t1-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t1-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
- - t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 2. SUT [Server-Type-A1]:
- - testbedname: testbed1.
- - hostname: t1-sut2.
- - CIMC IP: 10.30.50.18
- - Host IP: 10.30.51.18
- - portnames:
- - t1-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
- - t1-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
- - t1-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
- - t1-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
- - t1-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t1-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t1-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
- - t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 3. TG [Server-Type-A2]:
- - testbedname: testbed1.
- - hostname: t1-tg1.
- - CIMC IP: 10.30.50.16
- - Host IP: 10.30.51.16
- - portnames:
- - t1-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t1-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t1-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t1-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t1-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t1-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t1-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t1-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t1-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- 4. SUT [Server-Type-A1]:
- - testbedname: testbed2.
- - hostname: t2-sut1.
- - CIMC IP: 10.30.50.21
- - Host IP: 10.30.51.21
- - portnames:
- - t2-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
- - t2-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
- - t2-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
- - t2-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
- - t2-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t2-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t2-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
- - t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 5. SUT [Server-Type-A1]:
- - testbedname: testbed2.
- - hostname: t2-sut2.
- - CIMC IP: 10.30.50.22
- - Host IP: 10.30.51.22
- - portnames:
- - t2-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
- - t2-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
- - t2-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
- - t2-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
- - t2-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t2-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t2-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
- - t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 6. TG [Server-Type-A2]:
- - testbedname: testbed2.
- - hostname: t2-tg1.
- - CIMC IP: 10.30.50.20
- - Host IP: 10.30.51.20
- - portnames:
- - t2-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t2-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t2-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t2-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t2-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t2-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t2-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t2-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t2-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- 7. SUT [Server-Type-A1]:
- - testbedname: testbed3.
- - hostname: t3-sut1.
- - CIMC IP: 10.30.50.25
- - Host IP: 10.30.51.25
- - portnames:
- - t3-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
- - t3-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
- - t3-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
- - t3-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
- - t3-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t3-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t3-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
- - t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 8. SUT [Server-Type-A1]:
- - testbedname: testbed3.
- - hostname: t3-sut2.
- - CIMC IP: 10.30.50.26
- - Host IP: 10.30.51.26
- - portnames:
- - t3-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
- - t3-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
- - t3-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
- - t3-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
- - t3-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t3-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t3-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
- - t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 9. TG [Server-Type-A2]:
- - testbedname: testbed3.
- - hostname: t3-tg1.
- - CIMC IP: 10.30.50.24
- - Host IP: 10.30.51.24
- - portnames:
- - t3-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t3-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t3-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t3-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t3-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t3-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t3-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t3-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t3-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t3-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t3-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t3-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-```
-
#### 3-Node-Skylake Servers (3n-skx) PROD
```
@@ -1531,7 +1343,7 @@ Note: Server19 (TG) is shared between testbed33 & testbed34
- s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
```
-#### 3-Node-Denverton Servers (3n-dnv) WIP
+#### 3-Node-Denverton Servers (3n-dnv) PROD
```
- ServerB30 [Server-Type-B10]:
@@ -1664,7 +1476,7 @@ Note: Server19 (TG) is shared between testbed33 & testbed34
- s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
```
-#### 2-Node-Denverton Wiring (2n-dnv) WIP
+#### 2-Node-Denverton Wiring (2n-dnv) PROD
```
- testbed26:
@@ -1761,7 +1573,7 @@ Note: Server19 (TG) is shared between testbed33 & testbed34
- s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
```
-#### 2-Node-ThunderX2 Wiring (2n-tx2) WIP
+#### 2-Node-ThunderX2 Wiring (2n-tx2) PROD
```
- testbed34:
@@ -1770,83 +1582,6 @@ Note: Server19 (TG) is shared between testbed33 & testbed34
- s27-t34-sut1-c18/p2 - s19-t33t34-tg1-c8/p2.
```
-
-#### 3-Node-Haswell Wiring (3n-hsw) PROD
-
-```
- 1. testbed1:
- - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
- - t1-tg1-c1/p1 to t1-sut1-c1/p2.
- - t1-sut1-c1/p1 to t1-sut2-c1/p2.
- - t1-sut2-c1/p1 to t1-tg1-c1/p2.
- - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
- - t1-tg1-c2/p1 to t1-sut1-c2/p2.
- - t1-sut1-c2/p1 to t1-sut2-c2/p2.
- - t1-sut2-c2/p1 to t1-tg1-c2/p2.
- - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
- - t1-tg1-c4/p1 to t1-sut1-c4/p2.
- - t1-sut1-c4/p1 to t1-sut2-c4/p2.
- - t1-sut2-c4/p1 to t1-tg1-c4/p2.
- - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
- - t1-tg1-c5/p1 to t1-sut1-c5/p2.
- - t1-sut1-c5/p1 to t1-sut2-c5/p2.
- - t1-sut2-c5/p1 to t1-tg1-c5/p2.
- - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
- - t1-tg1-c2/p1 to t1-sut1-cm/p2.
- - t1-sut1-cm/p1 to t1-sut2-cm/p2.
- - t1-sut2-cm/p1 to t1-tg1-c2/p2.
- - TG loopback ports Intel NIC x710 2p10GE
- - t1-tg1-c6/p1 to t1-tg1-c6/p2.
-
- 2. testbed2:
- - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
- - t2-tg1-c1/p1 to t2-sut1-c1/p2.
- - t2-sut1-c1/p1 to t2-sut2-c1/p2.
- - t2-sut2-c1/p1 to t2-tg1-c1/p2.
- - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
- - t2-tg1-c2/p1 to t2-sut1-c2/p2.
- - t2-sut1-c2/p1 to t2-sut2-c2/p2.
- - t2-sut2-c2/p1 to t2-tg1-c2/p2.
- - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
- - t2-tg1-c4/p1 to t2-sut1-c4/p2.
- - t2-sut1-c4/p1 to t2-sut2-c4/p2.
- - t2-sut2-c4/p1 to t2-tg1-c4/p2.
- - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
- - t2-tg1-c5/p1 to t2-sut1-c5/p2.
- - t2-sut1-c5/p1 to t2-sut2-c5/p2.
- - t2-sut2-c5/p1 to t2-tg1-c5/p2.
- - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
- - t2-tg1-c2/p1 to t2-sut1-cm/p2.
- - t2-sut1-cm/p1 to t2-sut2-cm/p2.
- - t2-sut2-cm/p1 to t2-tg1-c2/p2.
- - TG loopback ports Intel NIC x710 2p10GE
- - t2-tg1-c6/p1 to t2-tg1-c6/p2.
-
- 3. testbed3:
- - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
- - t3-tg1-c1/p1 to t3-sut1-c1/p2.
- - t3-sut1-c1/p1 to t3-sut2-c1/p2.
- - t3-sut2-c1/p1 to t3-tg1-c1/p2.
- - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
- - t3-tg1-c2/p1 to t3-sut1-c2/p2.
- - t3-sut1-c2/p1 to t3-sut2-c2/p2.
- - t3-sut2-c2/p1 to t3-tg1-c2/p2.
- - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
- - t3-tg1-c4/p1 to t3-sut1-c4/p2.
- - t3-sut1-c4/p1 to t3-sut2-c4/p2.
- - t3-sut2-c4/p1 to t3-tg1-c4/p2.
- - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
- - t3-tg1-c5/p1 to t3-sut1-c5/p2.
- - t3-sut1-c5/p1 to t3-sut2-c5/p2.
- - t3-sut2-c5/p1 to t3-tg1-c5/p2.
- - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
- - t3-tg1-c2/p1 to t3-sut1-cm/p2.
- - t3-sut1-cm/p1 to t3-sut2-cm/p2.
- - t3-sut2-cm/p1 to t3-tg1-c2/p2.
- - TG loopback ports Intel NIC x710 2p10GE
- - t3-tg1-c6/p1 to t3-tg1-c6/p2.
-```
-
#### 3-Node-Skylake Wiring (3n-skx) PROD
```
@@ -1912,7 +1647,7 @@ To be completed.
- s18-t33-sut2-c4/p1 - s19-t33t34-tg1-c4/p1.
```
-#### 3-Node-Denverton Wiring (3n-dnv) WIP
+#### 3-Node-Denverton Wiring (3n-dnv) PROD
```
- testbed35:
diff --git a/docs/lab/testbeds_ucs_hsw_hw_bios_cfg.md b/docs/lab/testbeds_ucs_hsw_hw_bios_cfg.md
deleted file mode 100644
index 8dcd1f0e8c..0000000000
--- a/docs/lab/testbeds_ucs_hsw_hw_bios_cfg.md
+++ /dev/null
@@ -1,740 +0,0 @@
-# Cisco UCS c240m4 Haswell Servers - HW and BIOS Configuration
-
-1. [Linux lscpu](#linux-lscpu)
-1. [Linux dmidecode pci](#linux-dmidecode-pci)
-1. [Linux dmidecode memory](#linux-dmidecode-memory)
-1. [Xeon Hsw Server BIOS Configuration](#xeon-hsw-server-bios-configuration)
-
-## Linux lscpu
-
-```
- $ lscpu
- Architecture: x86_64
- CPU op-mode(s): 32-bit, 64-bit
- Byte Order: Little Endian
- CPU(s): 36
- On-line CPU(s) list: 0-35
- Thread(s) per core: 1
- Core(s) per socket: 18
- Socket(s): 2
- NUMA node(s): 2
- Vendor ID: GenuineIntel
- CPU family: 6
- Model: 63
- Model name: Intel(R) Xeon(R) CPU E5-2699 v3 @ 2.30GHz
- Stepping: 2
- CPU MHz: 2294.249
- BogoMIPS: 4589.82
- Virtualization: VT-x
- L1d cache: 32K
- L1i cache: 32K
- L2 cache: 256K
- L3 cache: 46080K
- NUMA node0 CPU(s): 0-17
- NUMA node1 CPU(s): 18-35
- Flags: fpu vme de pse tsc msr pae mce cx8 apic sep mtrr pge mca cmov pat pse36 clflush dts acpi mmx fxsr sse sse2 ss ht tm pbe syscall nx pdpe1gb rdtscp lm constant_tsc arch_perfmon pebs bts rep_good nopl xtopology nonstop_tsc aperfmperf eagerfpu pni pclmulqdq
- dtes64 monitor ds_cpl vmx smx est tm2 ssse3 sdbg fma cx16 xtpr pdcm pcid dca sse4_1 sse4_2 x2apic movbe popcnt tsc_deadline_timer aes xsave avx f16c rdrand lahf_lm abm epb tpr_shadow vnmi flexpriority ept vpid fsgsbase tsc_adjust bmi1 avx2 smep bmi2 erms invpcid cqm xsaveopt
- cqm_llc cqm_occup_llc dtherm arat pln pts
-```
-
-## Linux dmidecode pci
-
-```
- $ dmidecode --type 9 | grep 'Handle\|Slot\|Type\|Address'
- Handle 0x0046, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:1
- Type: x8 PCI Express 3 x8
- Bus Address: 0000:0a:02.0
- Handle 0x0047, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:2
- Type: x8 PCI Express 3 x8
- Bus Address: 0000:0e:03.2
- Handle 0x0048, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:3
- Type: x8 PCI Express 3 x8
- Bus Address: 0000:0d:03.0
- Handle 0x0049, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:4
- Type: x8 PCI Express 3 x8
- Bus Address: 0000:85:02.2
- Handle 0x004A, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:5
- Type: x8 PCI Express 3 x16
- Bus Address: 0000:87:03.0
- Handle 0x004B, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:6
- Type: x8 PCI Express 3 x8
- Bus Address: 0000:84:02.0
- Handle 0x004C, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:MLOM
- Type: x8 Other
- Bus Address: 0000:01:01.0
- Handle 0x004D, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:HBA
- Type: x8 Other
- Bus Address: 0000:0c:02.2
- Handle 0x004E, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:NVMe1
- Type: x4 PCI Express 3 x4
- Bus Address: 0000:82:01.0
- Handle 0x004F, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:NVMe2
- Type: x4 PCI Express 3 x4
- Bus Address: 0000:83:01.1
- Handle 0x0050, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:2.1
- Type: x16 PCI Express 3 x16
- Bus Address: 0000:00:1f.7
- Handle 0x0051, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:2.2
- Type: x16 PCI Express 3 x16
- Bus Address: 0000:00:1f.7
- Handle 0x0052, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:2.3
- Type: x16 PCI Express 3 x16
- Bus Address: 0000:00:1f.7
- Handle 0x0053, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:2.4
- Type: x16 PCI Express 3 x16
- Bus Address: 0000:00:1f.7
- Handle 0x0054, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:2.5
- Type: x16 PCI Express 3 x16
- Bus Address: 0000:00:1f.7
- Handle 0x0055, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:5.1
- Type: x8 PCI Express 3 x16
- Bus Address: 0000:00:1f.7
- Handle 0x0056, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:5.2
- Type: x8 PCI Express 3 x16
- Bus Address: 0000:00:1f.7
- Handle 0x0057, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:5.3
- Type: x8 PCI Express 3 x16
- Bus Address: 0000:00:1f.7
- Handle 0x0058, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:5.4
- Type: x8 PCI Express 3 x16
- Bus Address: 0000:00:1f.7
- Handle 0x0059, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:5.5
- Type: x8 PCI Express 3 x16
- Bus Address: 0000:00:1f.7
-```
-
-## Linux dmidecode memory
-
-```
- $ dmidecode -t memory
- # dmidecode 2.12
- SMBIOS 2.8 present.
-
- Handle 0x0022, DMI type 16, 23 bytes
- Physical Memory Array
- Location: System Board Or Motherboard
- Use: System Memory
- Error Correction Type: Multi-bit ECC
- Maximum Capacity: 1536 GB
- Error Information Handle: Not Provided
- Number Of Devices: 24
-
- Handle 0x0024, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMM_A1
- Bank Locator: NODE 0 CHANNEL 0 DIMM 0
- Type: Other
- Type Detail: None
- Speed: 2133 MHz
- Manufacturer: 0xAD00
- Serial Number: 80EC7380
- Asset Tag: DIMM_A1_AssetTag
- Part Number: HMA84GL7MMR4N-TF
- Rank: 4
- Configured Clock Speed: 2133 MHz
-
- Handle 0x0025, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMM_A2
- Bank Locator: NODE 0 CHANNEL 0 DIMM 1
- Type: Other
- Type Detail: None
- Speed: 2133 MHz
- Manufacturer: 0xAD00
- Serial Number: 80EC73D1
- Asset Tag: DIMM_A2_AssetTag
- Part Number: HMA84GL7MMR4N-TF
- Rank: 4
- Configured Clock Speed: 2133 MHz
-
- Handle 0x0026, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: Unknown
- Data Width: Unknown
- Size: No Module Installed
- Form Factor: DIMM
- Set: None
- Locator: DIMM_A3
- Bank Locator: NODE 0 CHANNEL 0 DIMM 2
- Type: Other
- Type Detail: None
- Speed: Unknown
- Manufacturer: NO DIMM
- Serial Number: NO DIMM
- Asset Tag: NO DIMM
- Part Number: NO DIMM
- Rank: Unknown
- Configured Clock Speed: Unknown
-
- Handle 0x0027, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMM_B1
- Bank Locator: NODE 0 CHANNEL 1 DIMM 0
- Type: Other
- Type Detail: None
- Speed: 2133 MHz
- Manufacturer: 0xAD00
- Serial Number: 80EC7325
- Asset Tag: DIMM_B1_AssetTag
- Part Number: HMA84GL7MMR4N-TF
- Rank: 4
- Configured Clock Speed: 2133 MHz
-
- Handle 0x0028, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMM_B2
- Bank Locator: NODE 0 CHANNEL 1 DIMM 1
- Type: Other
- Type Detail: None
- Speed: 2133 MHz
- Manufacturer: 0xAD00
- Serial Number: 80EC7334
- Asset Tag: DIMM_B2_AssetTag
- Part Number: HMA84GL7MMR4N-TF
- Rank: 4
- Configured Clock Speed: 2133 MHz
-
- Handle 0x0029, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: Unknown
- Data Width: Unknown
- Size: No Module Installed
- Form Factor: DIMM
- Set: None
- Locator: DIMM_B3
- Bank Locator: NODE 0 CHANNEL 1 DIMM 2
- Type: Other
- Type Detail: None
- Speed: Unknown
- Manufacturer: NO DIMM
- Serial Number: NO DIMM
- Asset Tag: NO DIMM
- Part Number: NO DIMM
- Rank: Unknown
- Configured Clock Speed: Unknown
-
- Handle 0x002A, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMM_C1
- Bank Locator: NODE 0 CHANNEL 2 DIMM 0
- Type: Other
- Type Detail: None
- Speed: 2133 MHz
- Manufacturer: 0xAD00
- Serial Number: 80EC7329
- Asset Tag: DIMM_C1_AssetTag
- Part Number: HMA84GL7MMR4N-TF
- Rank: 4
- Configured Clock Speed: 2133 MHz
-
- Handle 0x002B, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMM_C2
- Bank Locator: NODE 0 CHANNEL 2 DIMM 1
- Type: Other
- Type Detail: None
- Speed: 2133 MHz
- Manufacturer: 0xAD00
- Serial Number: 80EC732D
- Asset Tag: DIMM_C2_AssetTag
- Part Number: HMA84GL7MMR4N-TF
- Rank: 4
- Configured Clock Speed: 2133 MHz
-
- Handle 0x002C, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: Unknown
- Data Width: Unknown
- Size: No Module Installed
- Form Factor: DIMM
- Set: None
- Locator: DIMM_C3
- Bank Locator: NODE 0 CHANNEL 2 DIMM 2
- Type: Other
- Type Detail: None
- Speed: Unknown
- Manufacturer: NO DIMM
- Serial Number: NO DIMM
- Asset Tag: NO DIMM
- Part Number: NO DIMM
- Rank: Unknown
- Configured Clock Speed: Unknown
-
- Handle 0x002D, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMM_D1
- Bank Locator: NODE 0 CHANNEL 3 DIMM 0
- Type: Other
- Type Detail: None
- Speed: 2133 MHz
- Manufacturer: 0xAD00
- Serial Number: 80EC73D3
- Asset Tag: DIMM_D1_AssetTag
- Part Number: HMA84GL7MMR4N-TF
- Rank: 4
- Configured Clock Speed: 2133 MHz
-
- Handle 0x002E, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMM_D2
- Bank Locator: NODE 0 CHANNEL 3 DIMM 1
- Type: Other
- Type Detail: None
- Speed: 2133 MHz
- Manufacturer: 0xAD00
- Serial Number: 80EC7330
- Asset Tag: DIMM_D2_AssetTag
- Part Number: HMA84GL7MMR4N-TF
- Rank: 4
- Configured Clock Speed: 2133 MHz
-
- Handle 0x002F, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: Unknown
- Data Width: Unknown
- Size: No Module Installed
- Form Factor: DIMM
- Set: None
- Locator: DIMM_D3
- Bank Locator: NODE 0 CHANNEL 3 DIMM 2
- Type: Other
- Type Detail: None
- Speed: Unknown
- Manufacturer: NO DIMM
- Serial Number: NO DIMM
- Asset Tag: NO DIMM
- Part Number: NO DIMM
- Rank: Unknown
- Configured Clock Speed: Unknown
-
- Handle 0x0030, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMM_E1
- Bank Locator: NODE 1 CHANNEL 0 DIMM 0
- Type: Other
- Type Detail: None
- Speed: 2133 MHz
- Manufacturer: 0xAD00
- Serial Number: 80E54252
- Asset Tag: DIMM_E1_AssetTag
- Part Number: HMA84GL7MMR4N-TF
- Rank: 4
- Configured Clock Speed: 2133 MHz
-
- Handle 0x0031, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMM_E2
- Bank Locator: NODE 1 CHANNEL 0 DIMM 1
- Type: Other
- Type Detail: None
- Speed: 2133 MHz
- Manufacturer: 0xAD00
- Serial Number: 80E54235
- Asset Tag: DIMM_E2_AssetTag
- Part Number: HMA84GL7MMR4N-TF
- Rank: 4
- Configured Clock Speed: 2133 MHz
-
- Handle 0x0032, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: Unknown
- Data Width: Unknown
- Size: No Module Installed
- Form Factor: DIMM
- Set: None
- Locator: DIMM_E3
- Bank Locator: NODE 1 CHANNEL 0 DIMM 2
- Type: Other
- Type Detail: None
- Speed: Unknown
- Manufacturer: NO DIMM
- Serial Number: NO DIMM
- Asset Tag: NO DIMM
- Part Number: NO DIMM
- Rank: Unknown
- Configured Clock Speed: Unknown
-
- Handle 0x0033, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMM_F1
- Bank Locator: NODE 1 CHANNEL 1 DIMM 0
- Type: Other
- Type Detail: None
- Speed: 2133 MHz
- Manufacturer: 0xAD00
- Serial Number: 80E54218
- Asset Tag: DIMM_F1_AssetTag
- Part Number: HMA84GL7MMR4N-TF
- Rank: 4
- Configured Clock Speed: 2133 MHz
-
- Handle 0x0034, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMM_F2
- Bank Locator: NODE 1 CHANNEL 1 DIMM 1
- Type: Other
- Type Detail: None
- Speed: 2133 MHz
- Manufacturer: 0xAD00
- Serial Number: 80E54236
- Asset Tag: DIMM_F2_AssetTag
- Part Number: HMA84GL7MMR4N-TF
- Rank: 4
- Configured Clock Speed: 2133 MHz
-
- Handle 0x0035, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: Unknown
- Data Width: Unknown
- Size: No Module Installed
- Form Factor: DIMM
- Set: None
- Locator: DIMM_F3
- Bank Locator: NODE 1 CHANNEL 1 DIMM 2
- Type: Other
- Type Detail: None
- Speed: Unknown
- Manufacturer: NO DIMM
- Serial Number: NO DIMM
- Asset Tag: NO DIMM
- Part Number: NO DIMM
- Rank: Unknown
- Configured Clock Speed: Unknown
-
- Handle 0x0036, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMM_G1
- Bank Locator: NODE 1 CHANNEL 2 DIMM 0
- Type: Other
- Type Detail: None
- Speed: 2133 MHz
- Manufacturer: 0xAD00
- Serial Number: 80E54247
- Asset Tag: DIMM_G1_AssetTag
- Part Number: HMA84GL7MMR4N-TF
- Rank: 4
- Configured Clock Speed: 2133 MHz
-
- Handle 0x0037, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMM_G2
- Bank Locator: NODE 1 CHANNEL 2 DIMM 1
- Type: Other
- Type Detail: None
- Speed: 2133 MHz
- Manufacturer: 0xAD00
- Serial Number: 80E5421E
- Asset Tag: DIMM_G2_AssetTag
- Part Number: HMA84GL7MMR4N-TF
- Rank: 4
- Configured Clock Speed: 2133 MHz
-
- Handle 0x0038, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: Unknown
- Data Width: Unknown
- Size: No Module Installed
- Form Factor: DIMM
- Set: None
- Locator: DIMM_G3
- Bank Locator: NODE 1 CHANNEL 2 DIMM 2
- Type: Other
- Type Detail: None
- Speed: Unknown
- Manufacturer: NO DIMM
- Serial Number: NO DIMM
- Asset Tag: NO DIMM
- Part Number: NO DIMM
- Rank: Unknown
- Configured Clock Speed: Unknown
-
- Handle 0x0039, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMM_H1
- Bank Locator: NODE 1 CHANNEL 3 DIMM 0
- Type: Other
- Type Detail: None
- Speed: 2133 MHz
- Manufacturer: 0xAD00
- Serial Number: 80E5423C
- Asset Tag: DIMM_H1_AssetTag
- Part Number: HMA84GL7MMR4N-TF
- Rank: 4
- Configured Clock Speed: 2133 MHz
-
- Handle 0x003A, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMM_H2
- Bank Locator: NODE 1 CHANNEL 3 DIMM 1
- Type: Other
- Type Detail: None
- Speed: 2133 MHz
- Manufacturer: 0xAD00
- Serial Number: 80E5424D
- Asset Tag: DIMM_H2_AssetTag
- Part Number: HMA84GL7MMR4N-TF
- Rank: 4
- Configured Clock Speed: 2133 MHz
-
- Handle 0x003B, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: Unknown
- Data Width: Unknown
- Size: No Module Installed
- Form Factor: DIMM
- Set: None
- Locator: DIMM_H3
- Bank Locator: NODE 1 CHANNEL 3 DIMM 2
- Type: Other
- Type Detail: None
- Speed: Unknown
- Manufacturer: NO DIMM
- Serial Number: NO DIMM
- Asset Tag: NO DIMM
- Part Number: NO DIMM
- Rank: Unknown
- Configured Clock Speed: Unknown
-```
-
-## Xeon Hsw Server BIOS Configuration
-
-```
- C240 / # scope bios
- C240 /bios # show advanced detail
- Set-up parameters:
- Intel(R) VT-d ATS Support: Enabled
- Adjacent Cache Line Prefetcher: Enabled
- All Onboard LOM Ports: Enabled
- Altitude: 300 M
- Bits per second: 115200
- Power Technology: Performance
- Channel Interleaving: Auto
- Intel(R) VT-d Coherency Support: Disabled
- Console Redirection: COM 0
- Number of Enabled Cores: All
- Energy Performance: Performance
- CPU Performance: Enterprise
- DCU IP Prefetcher: Enabled
- DCU Streamer Prefetch: Enabled
- Demand Scrub: Enabled
- Direct Cache Access Support: Auto
- Enhanced Intel Speedstep(R) Tec: Disabled
- Execute Disable: Enabled
- Flow Control: None
- Hardware Prefetcher: Enabled
- Intel(R) Hyper-Threading Techno: Disabled
- Intel(R) Turbo Boost Technology: Disabled
- Intel(R) VT: Enabled
- Intel(R) VT-d: Enabled
- Intel(R) Interrupt Remapping: Enabled
- Legacy USB Support: Enabled
- Extended APIC: XAPIC
- LOM Port 1 OptionROM: Enabled
- LOM Port 2 OptionROM: Enabled
- MMIO above 4GB: Enabled
- NUMA: Enabled
- PCI ROM CLP: Disabled
- Package C State Limit: C6 Retention
- Intel(R) Pass Through DMA: Disabled
- Patrol Scrub: Enabled
- xHCI Mode: Disabled
- All PCIe Slots OptionROM: Enabled
- PCIe Slot:1 OptionROM: Disabled
- PCIe Slot:2 OptionROM: Disabled
- PCIe Slot:3 OptionROM: Disabled
- PCIe Slot:4 OptionROM: Disabled
- PCIe Slot:5 OptionROM: Disabled
- PCIe Slot:6 OptionROM: Disabled
- PCIe Slot:HBA Link Speed: GEN3
- PCIe Slot:HBA OptionROM: Enabled
- PCIe Slot:MLOM OptionROM: Enabled
- PCIe Slot:N1 OptionROM: Enabled
- PCIe Slot:N2 OptionROM: Enabled
- Processor Power state C1 Enhanc: Disabled
- Processor C3 Report: Disabled
- Processor C6 Report: Disabled
- P-STATE Coordination: HW ALL
- Putty KeyPad: ESCN
- Energy Performance Tuning: BIOS
- QPI Link Frequency Select: Auto
- QPI Snoop Mode: Home Snoop
- Rank Interleaving: Auto
- Redirection After BIOS POST: Always Enable
- PCH SATA Mode: AHCI
- Select Memory RAS: Maximum Performance
- SR-IOV Support: Enabled
- Terminal Type: VT100
- Port 60/64 Emulation: Enabled
- Workload Configuration: Balanced
- CDN Support for VIC: Disabled
- Out-of-Band Management: Disabled
- C240-FCH1950V1H5 /bios/advanced #
-```