diff options
Diffstat (limited to 'docs/lab')
-rw-r--r-- | docs/lab/fdio-dc-physical.md | 2 | ||||
-rw-r--r-- | docs/lab/fdio-dc-physical.yaml | 2 | ||||
-rw-r--r-- | docs/lab/testbed_specifications.md | 373 |
3 files changed, 174 insertions, 203 deletions
diff --git a/docs/lab/fdio-dc-physical.md b/docs/lab/fdio-dc-physical.md index 5a2f9e2a17..055a084336 100644 --- a/docs/lab/fdio-dc-physical.md +++ b/docs/lab/fdio-dc-physical.md @@ -55,7 +55,7 @@ s88-t215-tg1,up,t215,2n-icx,SYS-740GP-TNRT,C7470KL07P50301,10.30.51.88,10.30.50. #### Rack YUL1-9 (3016.9) name,oper-status,testbed-id,role,model,s/n,mgmt-ip4,ipmi-ip4,rackid,rackunit mtl1-5-lb4m,up,switch,uplink,?,?,?,?,3016.9,u47,?,? -s52-t21-sut1,up,t21,2n-spr,SYS-741GE-TNRT,???,10.30.51.52,10.30.50.52,3016.9,u42-u45 +s52-t21-sut1,up,t21,2n-spr,SYS-741GE-TNRT,C7490FL36A40118,10.30.51.52,10.30.50.52,3016.9,u42-u45 s53-t21-tg1,up,t21,2n-spr,SYS-741GE-TNRT,???,10.30.51.53,10.30.50.53,3016.9,u38-u41 s54-t22-sut1,up,t22,2n-spr,SYS-741GE-TNRT,???,10.30.51.54,10.30.50.54,3016.9,u34-u37 s55-t22-tg1,up,t22,2n-spr,SYS-741GE-TNRT,???,10.30.51.55,10.30.50.55,3016.9,u30-u33 diff --git a/docs/lab/fdio-dc-physical.yaml b/docs/lab/fdio-dc-physical.yaml index b5940bde4d..cbcca02f76 100644 --- a/docs/lab/fdio-dc-physical.yaml +++ b/docs/lab/fdio-dc-physical.yaml @@ -116,7 +116,7 @@ yul1: name: s52-t21-sut1 oper_status: production device_type: SYS-741GE-TNRT - serial_number: ? + serial_number: C7490FL36A40118 mgmt_ip4: 10.30.51.52 lom_ip4: 10.30.50.52 - unit: 38..41 diff --git a/docs/lab/testbed_specifications.md b/docs/lab/testbed_specifications.md index e8ea4011d0..1c2d912979 100644 --- a/docs/lab/testbed_specifications.md +++ b/docs/lab/testbed_specifications.md @@ -19,10 +19,7 @@ 1. [2-Node-Full-SapphireRapids Xeon Intel (2nf-spr)](#2-node-full-sapphirerapids-xeon-intel-2nf-spr) 1. [2-Node-SapphireRapids Xeon Intel (2n-spr)](#2-Node-SapphireRapids-Xeon-Intel-2n-spr) 1. [Server Management](#server-management) - 1. [Requirements](#requirements) 1. [Addressing](#addressing) - 1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses) - 1. [Management VLAN IP Addresses](#management-vlan-ip-addresses) 1. [Server Specifications](#server-specifications) 1. [Server Types](#server-types) 1. [Naming Convention](#naming-convention) @@ -41,8 +38,7 @@ 1. [3-Node-Altra Servers (3n-alt) PROD](#3-node-altra-servers-3n-alt-prod) 1. [3-Node-Icelake Servers (3n-icx) PROD](#3-node-icelake-servers-3n-icx-prod) 1. [3-Node-SnowRidge Servers (3n-snr) PROD](#3-node-snowridge-servers-3n-snr-prod) - 1. ... - 1. ... + 1. [2-Node-SapphireRapids Servers (2n-spr) PROD](#2-Node-sapphirerapids-servers-2n-spr-prod) 1. [Per Testbed Wiring](#per-testbed-wiring) 1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod) 1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod) @@ -57,15 +53,7 @@ 1. [3-Node-Altra Wiring (3n-alt) PROD](#3-node-altra-wiring-3n-alt-prod) 1. [3-Node-Icelake Wiring (3n-icx) PROD](#3-node-icelake-wiring-3n-icx-prod) 1. [3-Node-SnowRidge Wiring (3n-snr) PROD](#3-node-snowridge-wiring-3n-snr-prod) - 1. ... - 1. ... -1. [Inventory](#inventory) - 1. [Appliances](#appliances) - 1. [Arm Servers](#arm-servers) - 1. [Xeon and Atom Servers](#xeon-and-atom-servers) - 1. [Network Interface Cards](#network-interface-cards) - 1. [Pluggables and Cables](#pluggables-and-cables) - 1. [Other Parts](#other-parts) + 1. [2-Node-SapphireRapids Wiring (2n-spr) PROD](#2-Node-sapphirerapids-wiring-2n-spr-prod) ## Purpose @@ -77,21 +65,22 @@ hosted by LFN FD.io CSIT project. ### Summary List ``` - #. Type Purpose SUT TG #TB #SUT #TG #skx #ps1 #rng #tx2 #tsh #alt #clx #zn2 #icx #snr - 1. 1-Node-Skylake nomad skx na 5 5 0 5 0 0 0 0 0 0 0 0 0 - 2. 1-Node-Cascadelake nomad clx na 1 1 0 0 0 0 0 0 0 1 0 0 0 - 3. 1-Node-AmpereAltra nomad alt na 2 2 0 0 0 0 0 0 2 0 0 0 0 - 4. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 1 1 0 0 0 0 0 0 0 0 - 5. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 6 0 0 0 - 6. 2-Node-ThunderX2 perf tx2 skx 1 1 .5 .5 0 0 1 0 0 0 0 0 0 - 7. 2-Node-Icelake perf icx icx 4 4 4 0 0 0 0 0 0 0 0 8 0 - 8. 3-Node-Rangeley perf rng skx 1 3 1 0 0 2 0 0 0 0 0 0 0 - 9. 3-Node-Taishan perf tsh skx 1 2 .5 .5 0 0 0 2 0 0 0 0 0 -10. 3-Node-Altra perf alt icx 1 2 1 0 0 0 0 0 2 0 0 1 0 -11. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 2 0 0 -12. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 6 0 -13. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 0 0 .5 2 - Totals: 23 31 14.5 7 1 2 1 2 4 7 2 15.5 2 + #. Type Purpose SUT TG #TB #SUT #TG #skx #ps1 #rng #tx2 #tsh #alt #clx #zn2 #icx #snr #spr + 1. 1-Node-Skylake nomad skx na 5 5 0 5 0 0 0 0 0 0 0 0 0 0 + 2. 1-Node-Cascadelake nomad clx na 1 1 0 0 0 0 0 0 0 1 0 0 0 0 + 3. 1-Node-AmpereAltra nomad alt na 2 2 0 0 0 0 0 0 2 0 0 0 0 0 + 4. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 + 5. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 6 0 0 0 0 + 6. 2-Node-ThunderX2 perf tx2 skx 1 1 .5 .5 0 0 1 0 0 0 0 0 0 0 + 7. 2-Node-Icelake perf icx icx 4 4 4 0 0 0 0 0 0 0 0 8 0 0 + 8. 3-Node-Rangeley perf rng skx 1 3 1 0 0 2 0 0 0 0 0 0 0 0 + 9. 3-Node-Taishan perf tsh skx 1 2 .5 .5 0 0 0 2 0 0 0 0 0 0 +10. 3-Node-Altra perf alt icx 1 2 1 0 0 0 0 0 2 0 0 1 0 0 +11. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 2 0 0 0 +12. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 6 0 0 +13. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 0 0 .5 2 0 +13. 2-Node-SapphireRapids perf spr spr 4 4 4 0 0 0 0 0 0 0 0 0 0 8 + Totals: 28 35 18.5 7 1 2 1 2 4 7 2 15.5 2 8 ``` ### 1-Node-Skylake Xeon Intel (1n-skx) @@ -185,32 +174,22 @@ Used for FD.io performance tests. ### 2-Node-Full-SapphireRapids Xeon Intel (2nf-spr) -One 2-Node-Full-SapphireRapids testbed includes one SUT (Server-Type-TODO) and -one TG (Server-Type-TODO) connected in a 2-node physical topology with NUMA (socket) daisy chaining. For more detail see [Server Types](#server-types) and [Testbed Topology-TODO](#TODO). -Used for FD.io performance tests in a full system SUT setup with all PCIe Gen5 x16 lane slots populated with 2p200GbE NICs. +One 2-Node-Full-SapphireRapids testbed includes one SUT (Server-Type-H1) and +one TG (Server-Type-H2) connected in a 2-node physical topology +with NUMA (socket) daisy chaining. For more detail see +[Server Types](#server-types) and [Testbed Topology-TODO](#TODO). +Used for FD.io performance tests in a full system SUT setup with all PCIe +Gen5 x16 lane slots populated with 2p200GbE NICs. ### 2-Node-SapphireRapids Xeon Intel (2n-spr) -Each 2-Node-SapphireRapids testbed includes one SUT (Server-Type-TODO) and -one TG (Server-Type-TODO) connected in a 2-node circular topology. For more detail see [Server Types](#server-types) and [Testbed Topology-TODO](#TODO). +Each 2-Node-SapphireRapids testbed includes one SUT (Server-Type-H5) and +one TG (Server-Type-H6) connected in a 2-node circular topology. For more +detail see [Server Types](#server-types) and [Testbed Topology-TODO](#TODO). Used for FD.io performance tests. ## Server Management -### Requirements - -For management purposes, each server must have following two ports -connected to the management network: - -``` -- 1GE IPMI port - - IPMI - Intelligent Platform Management Interface. - - Required for access to embedded server management with WebUI, CLI, - SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates. -- 1GE/10GE/40GE management port - - hostOS management port for general system management. -``` - ### Addressing Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a @@ -627,12 +606,12 @@ FD.io CSIT lab contains following server types: - Numa0: (x16, x16, x16 PCIe5.0 lanes) - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - PCIe Slot4 3b:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - PCIe Slot9 5e:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. + - PCIe Slot10 5e:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - Numa1: (x16, x16, x16 PCIe5.0 lanes) - - PCIe Slot6 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - PCIe Slot8 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - PCIe Slot10 d8:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. -23. TODO-REVIEW Server-Type-H2: Purpose - SapphireRapids Xeon TG for FD.io full system performance testing. + - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. + - PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. + - PCIe Slot11 d8:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. +23. Server-Type-H2: Purpose - SapphireRapids Xeon TG for FD.io full system performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -647,11 +626,11 @@ FD.io CSIT lab contains following server types: - Numa0: (x16, x16, x16 PCIe5.0 lanes) - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - PCIe Slot4 3b:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - PCIe Slot9 5e:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. + - PCIe Slot10 5e:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - Numa1: (x16, x16, x16 PCIe5.0 lanes) - - PCIe Slot6 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - PCIe Slot8 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - PCIe Slot10 d8:00.xx: empty. + - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. + - PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. + - PCIe Slot11 d8:00.xx: empty. 24. Server-Type-H3: Purpose - SapphireRapids Xeon SUT for FD.io performance testing. - Quantity: 1. - Physical connectivity: @@ -667,11 +646,11 @@ FD.io CSIT lab contains following server types: - Numa0: (x16, x16, x16 PCIe5.0 lanes) - PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel. - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel. - - PCIe Slot9 5e:00.xx: + - PCIe Slot10 5e:00.xx: empty. - Numa1: (x16, x16, x16 PCIe5.0 lanes) - - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel. - - PCIe Slot8 af:00.xx: e810-XXVDA4-4p25GE Intel. - - PCIe Slot10 d8:00.xx: empty. + - PCIe Slot7 86:00.xx: e810-2CQDA2-2p100GE Intel. + - PCIe Slot9 af:00.xx: e810-XXVDA4-4p25GE Intel. + - PCIe Slot11 d8:00.xx: empty. 25. Server-Type-H4: Purpose - SapphireRapids Xeon TG for FD.io performance testing. - Quantity: 1. - Physical connectivity: @@ -687,11 +666,11 @@ FD.io CSIT lab contains following server types: - Numa0: (x16, x16, x16 PCIe5.0 lanes) - PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel. - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel. - - PCIe Slot9 5e:00.xx: empty. + - PCIe Slot10 5e:00.xx: empty. - Numa1: (x16, x16, x16 PCIe5.0 lanes) - - PCIe Slot6 86:00.xx: empty. - - PCIe Slot8 af:00.xx: empty. - - PCIe Slot10 d8:00.xx: empty. + - PCIe Slot7 86:00.xx: empty. + - PCIe Slot9 af:00.xx: empty. + - PCIe Slot11 d8:00.xx: empty. 26. Server-Type-H5: Purpose - SapphireRapids Xeon SUT for FD.io performance testing. - Quantity: 2. - Physical connectivity: @@ -707,11 +686,11 @@ FD.io CSIT lab contains following server types: - Numa0: (x16, x16, x16 PCIe5.0 lanes) - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - PCIe Slot4 3b:00.xx: e810-2CQDA2-2p100GE Intel. - - PCIe Slot9 5e:00.xx: e810-XXVDA4-4p25GE Intel. + - PCIe Slot10 5e:00.xx: e810-XXVDA4-4p25GE Intel. - Numa1: (x16, x16, x16 PCIe5.0 lanes) - - PCIe Slot6 86:00.xx: empty. - - PCIe Slot8 af:00.xx: empty. - - PCIe Slot10 d8:00.xx: empty. + - PCIe Slot7 86:00.xx: empty. + - PCIe Slot9 af:00.xx: empty. + - PCIe Slot11 d8:00.xx: empty. 27. Server-Type-H6: Purpose - SapphireRapids Xeon TG for FD.io performance testing. - Quantity: 2. - Physical connectivity: @@ -727,11 +706,11 @@ FD.io CSIT lab contains following server types: - Numa0: (x16, x16, x16 PCIe5.0 lanes) - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - PCIe Slot4 3b:00.xx: e810-2CQDA2-2p100GE Intel. - - PCIe Slot9 5e:00.xx: e810-XXVDA4-4p25GE Intel. + - PCIe Slot10 5e:00.xx: e810-XXVDA4-4p25GE Intel. - Numa1: (x16, x16, x16 PCIe5.0 lanes) - - PCIe Slot6 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel. - - PCIe Slot10 d8:00.xx: empty. + - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. + - PCIe Slot9 af:00.xx: e810-2CQDA2-2p100GE Intel. + - PCIe Slot11 d8:00.xx: empty. ``` ### Naming Convention @@ -1046,8 +1025,8 @@ Note: Server19 (TG) is shared between testbed33 & testbed211 - SUT [Server-Type-F1]: - testbedname: testbed212. - hostname: s71-t212-sut1. - - IPMI IP: 10.30.51.81 - - Host IP: 10.30.50.81 + - IPMI IP: 10.30.50.81 + - Host IP: 10.30.51.81 - portnames: - s71-t212-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s71-t212-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. @@ -1060,8 +1039,8 @@ Note: Server19 (TG) is shared between testbed33 & testbed211 - TG [Server-Type-F2]: - testbedname: testbed212. - hostname: s72-t212-tg1. - - IPMI IP: 10.30.51.82 - - Host IP: 10.30.50.82 + - IPMI IP: 10.30.50.82 + - Host IP: 10.30.51.82 - portnames: - s72-t212-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s72-t212-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. @@ -1076,8 +1055,8 @@ Note: Server19 (TG) is shared between testbed33 & testbed211 - SUT [Server-Type-F1]: - testbedname: testbed213. - hostname: s83-t213-sut1. - - IPMI IP: 10.30.51.83 - - Host IP: 10.30.50.83 + - IPMI IP: 10.30.50.83 + - Host IP: 10.30.51.83 - portnames: - s83-t213-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s83-t213-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. @@ -1090,8 +1069,8 @@ Note: Server19 (TG) is shared between testbed33 & testbed211 - TG [Server-Type-F2]: - testbedname: testbed213. - hostname: s84-t213-tg1. - - IPMI IP: 10.30.51.84 - - Host IP: 10.30.50.84 + - IPMI IP: 10.30.50.84 + - Host IP: 10.30.51.84 - portnames: - s84-t213-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s84-t213-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. @@ -1106,8 +1085,8 @@ Note: Server19 (TG) is shared between testbed33 & testbed211 - SUT [Server-Type-F1]: - testbedname: testbed214. - hostname: s85-t214-sut1. - - IPMI IP: 10.30.51.85 - - Host IP: 10.30.50.85 + - IPMI IP: 10.30.50.85 + - Host IP: 10.30.51.85 - portnames: - s85-t214-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s85-t214-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. @@ -1120,8 +1099,8 @@ Note: Server19 (TG) is shared between testbed33 & testbed211 - TG [Server-Type-F2]: - testbedname: testbed214. - hostname: s86-t214-tg1. - - IPMI IP: 10.30.51.86 - - Host IP: 10.30.50.86 + - IPMI IP: 10.30.50.86 + - Host IP: 10.30.51.86 - portnames: - s86-t214-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s86-t214-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. @@ -1136,8 +1115,8 @@ Note: Server19 (TG) is shared between testbed33 & testbed211 - SUT [Server-Type-F1]: - testbedname: testbed215. - hostname: s87-t215-sut1. - - IPMI IP: 10.30.51.87 - - Host IP: 10.30.50.87 + - IPMI IP: 10.30.50.87 + - Host IP: 10.30.51.87 - portnames: - s87-t215-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s87-t215-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. @@ -1150,8 +1129,8 @@ Note: Server19 (TG) is shared between testbed33 & testbed211 - TG [Server-Type-F2]: - testbedname: testbed215. - hostname: s88-t215-tg1. - - IPMI IP: 10.30.51.88 - - Host IP: 10.30.50.88 + - IPMI IP: 10.30.50.88 + - Host IP: 10.30.51.88 - portnames: - s88-t215-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s88-t215-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. @@ -1405,6 +1384,107 @@ Note: Server19 (TG) is shared between testbed33 & testbed211 - s89-t39t310-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE. ``` +#### 2-Node-SapphireRapids Servers (2n-spr) PROD + +``` +- SUT [Server-Type-H1]: + - testbedname: testbed21. + - hostname: s52-t21-sut1. + - IPMI IP: 10.30.50.52 + - Host IP: 10.30.51.52 + - portnames: + - s52-t21-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE. + - s52-t21-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE. + - s52-t21-sut1-c4/p1 - 200GE-port1 ConnectX7-2p200GE. + - s52-t21-sut1-c4/p2 - 200GE-port2 ConnectX7-2p200GE. + - s52-t21-sut1-c10/p1 - 200GE-port1 ConnectX7-2p200GE. + - s52-t21-sut1-c10/p2 - 200GE-port2 ConnectX7-2p200GE. + - s52-t21-sut1-c7/p1 - 200GE-port1 ConnectX7-2p200GE. + - s52-t21-sut1-c7/p2 - 200GE-port2 ConnectX7-2p200GE. + - s52-t21-sut1-c9/p1 - 200GE-port1 ConnectX7-2p200GE. + - s52-t21-sut1-c9/p2 - 200GE-port2 ConnectX7-2p200GE. + - s52-t21-sut1-c11/p1 - 200GE-port1 ConnectX7-2p200GE. + - s52-t21-sut1-c11/p2 - 200GE-port2 ConnectX7-2p200GE. +- TG [Server-Type-H2]: + - testbedname: testbed21. + - hostname: s53-t21-tg1. + - IPMI IP: 10.30.51.53 + - Host IP: 10.30.50.53 + - portnames: + - s53-t21-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE. + - s53-t21-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE. + - s53-t21-tg1-c4/p1 - 200GE-port1 ConnectX7-2p200GE. + - s53-t21-tg1-c4/p2 - 200GE-port2 ConnectX7-2p200GE. + - s53-t21-tg1-c10/p1 - 200GE-port1 ConnectX7-2p200GE. + - s53-t21-tg1-c10/p2 - 200GE-port2 ConnectX7-2p200GE. + - s53-t21-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE. + - s53-t21-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE. + - s53-t21-tg1-c9/p1 - 200GE-port1 ConnectX7-2p200GE. + - s53-t21-tg1-c9/p2 - 200GE-port2 ConnectX7-2p200GE. +- SUT [Server-Type-H3]: + - testbedname: testbed22. + - hostname: s54-t22-sut1. + - IPMI IP: 10.30.50.54 + - Host IP: 10.30.51.54 + - portnames: + - s54-t22-sut1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s54-t22-sut1-c2/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s54-t22-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s54-t22-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s54-t22-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s54-t22-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s54-t22-sut1-c7/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s54-t22-sut1-c7/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s54-t22-sut1-c9/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s54-t22-sut1-c9/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s54-t22-sut1-c9/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s54-t22-sut1-c9/p4 - 25GE-port4 e810-XXVDA4-4p25GE. +- TG [Server-Type-H4]: + - testbedname: testbed22. + - hostname: s55-t22-tg1. + - IPMI IP: 10.30.51.55 + - Host IP: 10.30.50.55 + - portnames: + - s55-t22-tg1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s55-t22-tg1-c2/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s55-t22-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s55-t22-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s55-t22-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s55-t22-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. +- SUT [Server-Type-H5]: + - testbedname: testbed23. + - hostname: s56-t23-sut1. + - IPMI IP: 10.30.50.56 + - Host IP: 10.30.51.56 + - portnames: + - s56-t23-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE. + - s56-t23-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE. + - s56-t23-sut1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s56-t23-sut1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s56-t23-sut1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s56-t23-sut1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s56-t23-sut1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s56-t23-sut1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE. +- TG [Server-Type-H6]: + - testbedname: testbed23. + - hostname: s57-t23-tg1. + - IPMI IP: 10.30.51.57 + - Host IP: 10.30.50.57 + - portnames: + - s57-t23-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE. + - s57-t23-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE. + - s57-t23-tg1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s57-t23-tg1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s57-t23-tg1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s57-t23-tg1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s57-t23-tg1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s57-t23-tg1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s57-t23-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE. + - s57-t23-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE. + - s57-t23-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s57-t23-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +``` + ### Per Testbed Wiring #### 1-Node-Skylake Wiring (1n-skx) PROD @@ -1707,117 +1787,8 @@ To be completed. - s94-t39-sut2-c1/p3 to s89-t39t310-tg1-c6/p4. ``` -## Inventory - -### Appliances - -``` -1. Ixia PerfectStorm One Appliance - - 1 * PS10GE4NG - - Chassis: PS10GE4NG. - - Motherboard: SuperMicro X11DPG-QT. - - Processors: Quad-Core, Intel Processor. - - HW accelerators: FPGA offload. - - RAM Memory: 64GB. - - Disks: 1 * 1 TB, Enterprise Class, High MTBF. - - Physical Interfaces: 4 * 10GE SFP+. - - Operating System: Native IxOS. -``` - -### Arm Servers +#### 2-Node-SapphireRapids Wiring (2n-spr) PROD ``` -1. Arm Cortex A-72 servers - - 2 * ThunderX2 (VPP Device) - - Chassis: GIGABYTE Rack Mount - - Processors: 2* ThunderX2 CN9980 ~ 32* ThunderX2 - - RAM Memory: 16* 16GB DIMM - - Disks: 2* 480GB 6G SATA SSD SAMSUNG MZ7LH480 - - 1 * ThunderX2 (Performance) - - Chassis: GIGABYTE Rack Mount - - Processors: 2* ThunderX2 CN9975 ~ 28* ThunderX2. - - RAM Memory: 4* 32GB RDIMM - - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25 - - 2 * Huawei TaiShan 2280. - - Chassis: Huawei TaiShan 2280. - - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72. - - RAM Memory: 8* 16GB DDR4-2400MT/s. - - Disks: 1* 4TB SATA HDD. -2. Arm Neoverse N1 servers - - 2 * Ampere Altra (Performance) - - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U - - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1) - - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1 - - RAM Memory: 16* 8GB DDR4-3200MT/s - - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983 - - 2 * Ampere Altra (Build) - - Chassis: Gigabyte R152-P30-00 1U - - Motherboard: MP32-AR1-00 - - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1) - - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1 - - RAM Memory: 12* 16GB DDR4-3200MT/s - - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983 -``` - -### Xeon and Atom Servers - -``` -1. Intel Xeon servers: - - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors. - - Chassis: SuperMicro SYS-7049GP-TRT. - - Motherboard: SuperMicro X11DPG-QT. - - Processors: 2* Intel Platinum 8180 2.5 GHz. - - RAM Memory: 16* 16GB DDR4-2666MHz. - - Disks: 2* 1.6TB 6G SATA SSD. -2. Intel Atom servers with Rangely processors. - - 3 * Netgate XG-2758-1u - - Chassis: Netgate XG-2758-1u - - Processors: 1* Rangely (Atom) C2758 2.4 GHz - - RAM Memory: 16GB ECC - - Disks: 150 GB -``` - -### Network Interface Cards - -``` -1. 10GE NICs - - ? -2. 25GE NICs - - ? -3. 40GE NICs - - ? -4. 100GE NICs - - ? -``` - -### Pluggables and Cables - -Pluggables: - -``` -1. 10GE SFP+ - - ? -2. 25GE SFP28 - - ? -3. 40GE QSFP+ - - ? -4. 100GE - - ? -``` - -Standalone cables: - -``` -1. 10GE - - ? -2. 25GE - - ? -3. 40GE QSFP+ - - ? -4. 100GE - - ? -``` - -### Other Parts - -None. +TBD +```
\ No newline at end of file |