Overview
========
-Testpmd Performance Test Topologies
------------------------------------
+Tested Topologies HW
+--------------------
CSIT Testpmd performance tests are executed on physical baremetal servers hosted
-by LF FD.io project. Testbed physical topology is shown in the figure below.::
+by LF FD.io project. Testbed physical topology is shown in the figure below.
+
+::
+------------------------+ +------------------------+
| | | |
@@ -25,13 +27,14 @@ by LF FD.io project. Testbed physical topology is shown in the figure below.::
| |
+-----------+
-SUT1 and SUT2 are two System Under Test servers (Cisco UCS C240, each with two
-Intel XEON CPUs), TG is a Traffic Generator (TG, another Cisco UCS C240, with
-two Intel XEON CPUs). SUTs run Testpmd SW application in Linux user-mode as a
-Device Under Test (DUT). TG runs TRex SW application as a packet Traffic
-Generator. Physical connectivity between SUTs and to TG is provided using
-different NIC models that need to be tested for performance. Currently
-installed and tested NIC models include:
+SUT1 and SUT2 are two System Under Test servers (currently Cisco UCS C240,
+each with two Intel XEON CPUs), TG is a Traffic Generator (TG, currently
+another Cisco UCS C240, with two Intel XEON CPUs). SUTs run Testpmd SW
+application in Linux user-mode as a Device Under Test (DUT). TG runs TRex SW
+application as a packet Traffic Generator. Physical connectivity between SUTs
+and to TG is provided using direct links (no L2 switches) connecting different
+NIC models that need to be tested for performance. Currently installed and
+tested NIC models include:
#. 2port10GE X520-DA2 Intel.
#. 2port10GE X710 Intel.
@@ -39,26 +42,39 @@ installed and tested NIC models include:
#. 2port40GE VIC1385 Cisco.
#. 2port40GE XL710 Intel.
-Detailed LF FD.io test bed specification and topology is described on `CSIT LF
-testbed wiki page <https://wiki.fd.io/view/CSIT/CSIT_LF_testbed>`_.
+Detailed LF FD.io test bed specification and topology is described in
+`wiki CSIT LF testbed <https://wiki.fd.io/view/CSIT/CSIT_LF_testbed>`_.
-Testpmd Performance Tests Overview
-----------------------------------
+Testing Summary
+---------------
-Performance tests are split into two main categories:
+Performance tests are split into the two main categories:
- Throughput discovery - discovery of packet forwarding rate using binary search
- in accordance to RFC2544.
+ in accordance with RFC2544.
- - NDR - discovery of Non Drop Rate, zero packet loss.
- - PDR - discovery of Partial Drop Rate, with specified non-zero packet loss.
+ - NDR - discovery of Non Drop Rate packet throughput, at zero packet loss;
+ followed by packet one-way latency measurements at 10%, 50% and 100% of
+ discovered NDR throughput.
+ - PDR - discovery of Partial Drop Rate, with specified non-zero packet loss
+ currently set to 0.5%; followed by packet one-way latency measurements at
+ 100% of discovered PDR throughput.
- Throughput verification - verification of packet forwarding rate against
- previously discovered throughput rate. These tests are currently done against
+ previously discovered NDR throughput. These tests are currently done against
0.9 of reference NDR, with reference rates updated periodically.
-CSIT |release| includes following performance test suites:
+CSIT |release| includes following performance test suites, listed per NIC type:
- 2port10GE X520-DA2 Intel
- - **L2XC** - L2 Cross-Connect forwarding of untagged Ethernet frames.
+ - **L2IntLoop** - L2 Interface Loop forwarding any Ethernet frames between
+ two Interfaces.
+
+Execution of performance tests takes time, especially the throughput discovery
+tests. Due to limited HW testbed resources available within FD.io labs hosted
+by Linux Foundation, the number of tests for NICs other than X520 (a.k.a.
+Niantic) has been limited to few baseline tests. Over time we expect the HW
+testbed resources to grow, and will be adding complete set of performance
+tests for all models of hardware to be executed regularly and(or)
+continuously.