diff options
Diffstat (limited to 'docs')
-rw-r--r-- | docs/content/infrastructure/fdio_dc_testbed_specifications.md | 36 |
1 files changed, 18 insertions, 18 deletions
diff --git a/docs/content/infrastructure/fdio_dc_testbed_specifications.md b/docs/content/infrastructure/fdio_dc_testbed_specifications.md index 164e348bd1..cb0049bec3 100644 --- a/docs/content/infrastructure/fdio_dc_testbed_specifications.md +++ b/docs/content/infrastructure/fdio_dc_testbed_specifications.md @@ -1311,8 +1311,8 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s65-t37-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s65-t37-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s65-t37-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - - s65-t37-sut1-c6/p1 - 100GE-port1 ConnectX6-2p100GE. - - s65-t37-sut1-c6/p2 - 100GE-port2 ConnectX6-2p100GE. + - s65-t37-sut1-c10/p1 - 100GE-port1 ConnectX6-2p100GE. + - s65-t37-sut1-c10/p2 - 100GE-port2 ConnectX6-2p100GE. - SUT2 [Server-Type-F3]: - testbedname: testbed37. - hostname: s66-t37-sut2. @@ -1327,8 +1327,8 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s66-t37-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s66-t37-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s66-t37-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - - s65-t37-sut1-c6/p1 - 100GE-port1 ConnectX6-2p100GE. - - s65-t37-sut1-c6/p2 - 100GE-port2 ConnectX6-2p100GE. + - s65-t37-sut1-c10/p1 - 100GE-port1 ConnectX6-2p100GE. + - s65-t37-sut1-c10/p2 - 100GE-port2 ConnectX6-2p100GE. - TG [Server-Type-F3]: - testbedname: testbed37. - hostname: s67-t37-tg1. @@ -1343,8 +1343,8 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s67-t37-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s67-t37-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s67-t37-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - - s67-t37-tg1-c6/p1 - 100GE-port1 ConnectX6-2p100GE. - - s67-t37-tg1-c6/p2 - 100GE-port2 ConnectX6-2p100GE. + - s67-t37-tg1-c10/p1 - 100GE-port1 ConnectX6-2p100GE. + - s67-t37-tg1-c10/p2 - 100GE-port2 ConnectX6-2p100GE. - SUT1 [Server-Type-F3]: - testbedname: testbed38. - hostname: s78-t38-sut1. @@ -1359,8 +1359,8 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s78-t38-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s78-t38-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s78-t38-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - - s78-t38-sut1-c6/p1 - 100GE-port1 ConnectX6-2p100GE. - - s78-t38-sut1-c6/p2 - 100GE-port2 ConnectX6-2p100GE. + - s78-t38-sut1-c10/p1 - 100GE-port1 ConnectX6-2p100GE. + - s78-t38-sut1-c10/p2 - 100GE-port2 ConnectX6-2p100GE. - SUT2 [Server-Type-F3]: - testbedname: testbed38. - hostname: s79-t38-sut2. @@ -1375,8 +1375,8 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s79-t38-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s79-t38-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s79-t38-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - - s79-t38-sut2-c6/p1 - 100GE-port1 ConnectX6-2p100GE. - - s79-t38-sut2-c6/p2 - 100GE-port2 ConnectX6-2p100GE. + - s79-t38-sut2-c10/p1 - 100GE-port1 ConnectX6-2p100GE. + - s79-t38-sut2-c10/p2 - 100GE-port2 ConnectX6-2p100GE. - TG [Server-Type-F3]: - testbedname: testbed38. - hostname: s80-t38-tg1. @@ -1391,8 +1391,8 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s80-t38-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s80-t38-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s80-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - - s80-t38-tg1-c6/p1 - 100GE-port1 ConnectX6-2p100GE. - - s80-t38-tg1-c6/p2 - 100GE-port2 ConnectX6-2p100GE. + - s80-t38-tg1-c10/p1 - 100GE-port1 ConnectX6-2p100GE. + - s80-t38-tg1-c10/p2 - 100GE-port2 ConnectX6-2p100GE. ``` ### 3-Node-SnowRidge (3n-snr) @@ -1853,9 +1853,9 @@ To be completed. - s65-t37-sut1-c9/p2 to s66-t37-sut2-c9/p2. - s66-t37-sut2-c9/p1 to s67-t37-tg1-c9/p2. - ring4 200GE-ports ConnectX6-2p200GE: - - s67-t37-tg1-c6/p1 - s65-t37-sut1-c6/p2. - - s65-t37-sut1-c6/p1 - s66-t37-sut2-c6/p2. - - s66-t37-sut2-c6/p1 - s67-t37-tg1-c9-c6/p2. + - s67-t37-tg1-c10/p1 - s65-t37-sut1-c10/p2. + - s65-t37-sut1-c10/p1 - s66-t37-sut2-c10/p2. + - s66-t37-sut2-c10/p1 - s67-t37-tg1-c10/p2. - testbed38: - ring1 25GE-ports xxv710-DA2-2p25GE: - s80-t38-tg1-c2/p1 to s78-t38-sut1-c2/p1. @@ -1873,9 +1873,9 @@ To be completed. - s78-t38-sut1-c9/p2 to s79-t38-sut2-c9/p2. - s79-t38-sut2-c9/p1 to s80-t38-tg1-c9/p2. - ring4 200GE-ports ConnectX6-2p200GE: - - s80-t38-tg1-c6/p1 to s78-t38-sut1-c6/p1. - - s78-t38-sut1-c6/p2 to s79-t38-sut2-c6/p2. - - s79-t38-sut2-c6/p1 to s80-t38-tg1-c6/p2. + - s80-t38-tg1-c10/p1 to s78-t38-sut1-c10/p1. + - s78-t38-sut1-c10/p2 to s79-t38-sut2-c10/p2. + - s79-t38-sut2-c10/p1 to s80-t38-tg1-c10/p2. ``` ### 3-Node-SnowRidge (3n-snr) |