aboutsummaryrefslogtreecommitdiffstats
path: root/docs
diff options
context:
space:
mode:
Diffstat (limited to 'docs')
-rw-r--r--docs/lab/testbed_specifications.md323
-rw-r--r--docs/lab/testbeds_sm_skx_hw_bios_cfg.md578
2 files changed, 0 insertions, 901 deletions
diff --git a/docs/lab/testbed_specifications.md b/docs/lab/testbed_specifications.md
index 47c41c23d3..22dade917f 100644
--- a/docs/lab/testbed_specifications.md
+++ b/docs/lab/testbed_specifications.md
@@ -6,14 +6,12 @@
1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
- 1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2)
1. [2-Node-Icelake Xeon Intel (2n-icx)](#2-node-icelake-xeon-intel-2n-icx)
- 1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
1. [3-Node-Altra Arm Ampere (3n-alt)](#3-node-altra-arm-armpere-3n-alt)
@@ -32,14 +30,12 @@
1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
1. [1-Node-ThunderX2 Servers (1n-tx2) PROD](#1-node-thunderx2-servers-1n-tx2-prod)
1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod)
- 1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
1. [2-Node-Denverton Servers (2n-dnv) PROD](#2-node-denverton-servers-2n-dnv-prod)
1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod)
1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod])
1. [2-Node-ThunderX2 Servers (2n-tx2) PROD](#2-node-thunderx2-servers-2n-tx2-prod)
1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
- 1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod)
1. [3-Node-Altra Servers (3n-alt) PROD](#3-node-altra-servers-3n-alt-prod)
@@ -49,14 +45,12 @@
1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod)
1. [1-Node-Cascadelake Wiring (1n-clx) PROD](#1-node-cascadelake-wiring-1n-clx-prod)
- 1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
1. [2-Node-Denverton Wiring (2n-dnv) PROD](#2-node-denverton-wiring-2n-dnv-prod)
1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod])
1. [2-Node-ThunderX2 Wiring (2n-tx2) PROD](#2-node-thunderx2-wiring-2n-tx2-prod)
1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
- 1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
1. [3-Node-Rangeley Wiring (3n-rng) VERIFY](#3-node-rangeley-wiring-3n-rng-todo)
1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod)
1. [3-Node-Altra Wiring (3n-alt) PROD](#3-node-altra-wiring-3n-alt-prod)
@@ -122,13 +116,6 @@ NIC ports connected back-to-back ([Server Types](#server-types)).
Used for FD.io VPP_Device functional driver tests.
-### 2-Node-Skylake Xeon Intel (2n-skx)
-
-Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
-(Server-Type-B2) connected in a 2-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
### 2-Node-Denverton Atom Intel (2n-dnv)
Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
@@ -178,12 +165,6 @@ TG (Server-Type-A2) connected in a 3-node circular topology
([Server Types](#server-types)).
Used for FD.io performance tests.
-### 3-Node-Skylake Xeon Intel (3n-skx)
-
-Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
-TG (Server-Type-B2) connected in a 3-node circular topology.
-Used for FD.io performance tests.
-
### 3-Node-Rangeley Atom Testbeds
Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
@@ -1039,123 +1020,6 @@ connectivity and wiring across defined CSIT testbeds:
- s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
```
-#### 2-Node-Skylake Servers (2n-skx) PROD
-
-```
-- SUT [Server-Type-B1]:
- - testbedname: testbed21.
- - hostname: s3-t21-sut1.
- - IPMI IP: 10.30.50.41
- - Host IP: 10.30.51.44
- - portnames:
- - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- TG [Server-Type-B2]:
- - testbedname: testbed21.
- - hostname: s4-t21-tg1.
- - IPMI IP: 10.30.50.42
- - Host IP: 10.30.51.45
- - portnames:
- - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s3-t21-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
- - s3-t21-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
- - s3-t21-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
- - s3-t21-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
-- SUT [Server-Type-B1]:
- - testbedname: testbed22.
- - hostname: s5-t22-sut1.
- - IPMI IP: 10.30.50.49
- - Host IP: 10.30.51.52
- - portnames:
- - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- TG [Server-Type-B2]:
- - testbedname: testbed22.
- - hostname: s6-t22-tg1.
- - IPMI IP: 10.30.50.50
- - Host IP: 10.30.51.53
- - portnames:
- - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s6-t22-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
- - s6-t22-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
- - s6-t22-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
- - s6-t22-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
-- SUT [Server-Type-B1]:
- - testbedname: testbed23.
- - hostname: s7-t23-sut1.
- - IPMI IP: 10.30.50.51
- - Host IP: 10.30.51.54
- - portnames:
- - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- TG [Server-Type-B2]:
- - testbedname: testbed23.
- - hostname: s8-t23-tg1.
- - IPMI IP: 10.30.50.52
- - Host IP: 10.30.51.55
- - portnames:
- - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s8-t23-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
- - s8-t23-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
- - s8-t23-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
- - s8-t23-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
-- SUT [Server-Type-B1]:
- - testbedname: testbed24.
- - hostname: s9-t24-sut1.
- - IPMI IP: 10.30.50.53
- - Host IP: 10.30.51.56
- - portnames:
- - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- TG [Server-Type-B2]:
- - testbedname: testbed24.
- - hostname: s10-t24-tg1.
- - IPMI IP: 10.30.50.54
- - Host IP: 10.30.51.57
- - portnames:
- - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s10-t24-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
- - s10-t24-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
- - s10-t24-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
- - s10-t24-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
-```
-
#### 2-Node-Denverton Servers (2n-dnv) PROD
Note: ServerB28 (TG) is shared between testbed26 & testbed35
@@ -1512,91 +1376,6 @@ Note: Server19 (TG) is shared between testbed33 & testbed211
- s88-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
```
-#### 3-Node-Skylake Servers (3n-skx) PROD
-
-```
-- ServerB11 [Server-Type-B1]:
- - testbedname: testbed31.
- - hostname: s11-t31-sut1.
- - IPMI IP: 10.30.50.43
- - Host IP: 10.30.51.46
- - portnames:
- - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- ServerB12 [Server-Type-B1]:
- - testbedname: testbed31.
- - hostname: s12-t31-sut2.
- - IPMI IP: 10.30.50.44
- - Host IP: 10.30.51.47
- - portnames:
- - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
- - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
- - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
- - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
- - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- ServerB13 [Server-Type-B2]:
- - testbedname: testbed31.
- - hostname: s13-t31-tg1.
- - IPMI IP: 10.30.50.45
- - Host IP: 10.30.51.48
- - portnames:
- - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s13-t31-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
- - s13-t31-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
- - s13-t31-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
- - s13-t31-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
-- ServerB14 [Server-Type-B1]:
- - testbedname: testbed32.
- - hostname: s14-t32-sut1.
- - IPMI IP: 10.30.50.55
- - Host IP: 10.30.51.58
- - portnames:
- - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- ServerB15 [Server-Type-B1]:
- - testbedname: testbed32.
- - hostname: s15-t32-sut2.
- - IPMI IP: 10.30.50.56
- - Host IP: 10.30.51.59
- - portnames:
- - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
- - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
- - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
- - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
- - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- ServerB16 [Server-Type-B2]:
- - testbedname: testbed32.
- - hostname: s16-t32-tg1.
- - IPMI IP: 10.30.50.57
- - Host IP: 10.30.51.60
- - portnames:
- - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s16-t32-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
- - s16-t32-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
- - s16-t32-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
- - s16-t32-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
-```
-
#### 3-Node-Rangeley Servers (3n-rng) VERIFY
Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
@@ -1919,63 +1698,6 @@ Note: Server19 (TG) is shared between testbed33 & testbed211
- s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2.
```
-#### 2-Node-Skylake Wiring (2n-skx) PROD
-
-```
-- testbed21:
- - ring1 10GE-ports x710-4p10GE on SUT:
- - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
- - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
- - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
- - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
- - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
- - s4-t21-tg1-c10/p1 to s4-t21-tg1-c10/p2.
- - s4-t21-tg1-c10/p3 to s4-t21-tg1-c10/p4.
-- testbed22:
- - ring1 10GE-ports x710-4p10GE on SUT:
- - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
- - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
- - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
- - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
- - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
- - s6-t22-tg1-c10/p1 to s6-t22-tg1-c10/p2.
- - s6-t22-tg1-c10/p3 to s6-t22-tg1-c10/p4.
-- testbed23:
- - ring1 10GE-ports x710-4p10GE on SUT:
- - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
- - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
- - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
- - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
- - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
- - s8-t23-tg1-c10/p1 to s8-t23-tg1-c10/p2.
- - s8-t23-tg1-c10/p3 to s8-t23-tg1-c10/p4.
-- testbed24:
- - ring1 10GE-ports x710-4p10GE on SUT:
- - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
- - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
- - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
- - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
- - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
- - s10-t24-tg1-c10/p1 to s10-t24-tg1-c10/p2.
- - s10-t24-tg1-c10/p3 to s10-t24-tg1-c10/p4.
-```
-
#### 2-Node-Denverton Wiring (2n-dnv) PROD
```
@@ -2153,51 +1875,6 @@ Note: Server19 (TG) is shared between testbed33 & testbed211
- s88-t215-tg1-c6/p2 to s88-t215-tg1-c6/p1.
```
-#### 3-Node-Skylake Wiring (3n-skx) PROD
-
-```
-- testbed31:
- - ring1 10GE-ports x710-4p10GE on SUTs:
- - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
- - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
- - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
- - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
- - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
- - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
- - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
- - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
- - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
- - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
- - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
- - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
- - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
- - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
-- testbed32:
- - ring1 10GE-ports x710-4p10GE on SUTs:
- - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
- - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
- - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
- - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
- - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
- - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
- - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
- - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
- - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
- - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
- - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
- - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
- - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
- - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
-```
-
#### 3-Node-Rangeley Wiring (3n-rng) VERIFY
```
diff --git a/docs/lab/testbeds_sm_skx_hw_bios_cfg.md b/docs/lab/testbeds_sm_skx_hw_bios_cfg.md
deleted file mode 100644
index b00ba370b6..0000000000
--- a/docs/lab/testbeds_sm_skx_hw_bios_cfg.md
+++ /dev/null
@@ -1,578 +0,0 @@
-# SuperMicro Skylake Servers - HW and BIOS Configuration
-
-1. [Linux lscpu](#linux-lscpu)
-1. [Linux dmidecode](#dmidecode)
-1. [Xeon Skx Server BIOS Configuration](#xeon-skx-server-bios-configuration)
- 1. [Boot Feature](#boot-feature)
- 1. [CPU Configuration](#cpu-configuration)
- 1. [Advanced Power Management Configuration](#advanced-power-management-configuration)
- 1. [CPU P State Control](#cpu-p-state-control)
- 1. [Hardware PM State Control](#hardware-pm-state-control)
- 1. [CPU C State Control](#cpu-c-state-control)
- 1. [Package C State Control](#package-c-state-control)
- 1. [CPU T State Control](#cpu-t-state-control)
- 1. [Chipset Configuration](#chipset-configuration)
- 1. [North Bridge](#north-bridge)
- 1. [UPI Configuration](#upi-configuration)
- 1. [Memory Configuration](#memory-configuration)
- 1. [IIO Configuration](#iio-configuration)
- 1. [CPU1 Configuration](#cpu1-configuration)
- 1. [CPU2 Configuration](#cpu2-configuration)
- 1. [South Bridge](#south-bridge)
- 1. [PCIe/PCI/PnP Configuration](#pciepcipnp-configuration)
- 1. [ACPI Settings](#acpi-settings)
-1. [Xeon Skx Server Firmware Inventory](#xeon-skx-server-firmware-inventory)
-
-## Linux lscpu
-
-```
-$ lscpu
-Architecture: x86_64
-CPU op-mode(s): 32-bit, 64-bit
-Byte Order: Little Endian
-CPU(s): 112
-On-line CPU(s) list: 0-111
-Thread(s) per core: 2
-Core(s) per socket: 28
-Socket(s): 2
-NUMA node(s): 2
-Vendor ID: GenuineIntel
-CPU family: 6
-Model: 85
-Model name: Intel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz
-Stepping: 4
-CPU MHz: 2500.550
-BogoMIPS: 5000.00
-Virtualization: VT-x
-L1d cache: 32K
-L1i cache: 32K
-L2 cache: 1024K
-L3 cache: 39424K
-NUMA node0 CPU(s): 0-27,56-83
-NUMA node1 CPU(s): 28-55,84-111
-Flags: fpu vme de pse tsc msr pae mce cx8 apic sep mtrr pge mca
-cmov pat pse36 clflush dts acpi mmx fxsr sse sse2 ss ht tm pbe syscall nx
-pdpe1gb rdtscp lm constant_tsc art arch_perfmon pebs bts rep_good nopl xtopology
-nonstop_tsc cpuid aperfmperf pni pclmulqdq dtes64 monitor ds_cpl vmx smx est tm2
-ssse3 sdbg fma cx16 xtpr pdcm pcid dca sse4_1 sse4_2 x2apic movbe popcnt
-tsc_deadline_timer aes xsave avx f16c rdrand lahf_lm abm 3dnowprefetch
-cpuid_fault epb cat_l3 cdp_l3 invpcid_single pti ssbd mba ibrs ibpb stibp
-tpr_shadow vnmi flexpriority ept vpid fsgsbase tsc_adjustbmi1 hle avx2 smep bmi2
-erms invpcid rtm cqm mpx rdt_a avx512f avx512dq rdseed adx smap clflushopt clwb
-intel_pt avx512cd avx512bw avx512vl xsaveopt xsavec xgetbv1 xsaves cqm_llc
-cqm_occup_llc cqm_mbm_total cqm_mbm_local dtherm ida arat pln pts pku ospke
-md_clear flush_l1d
-```
-
-### Linux dmidecode
-
-```
- $ dmidecode
- # dmidecode 3.1
- Getting SMBIOS data from sysfs.
- SMBIOS 3.2.1 present.
- Table at 0x6F388000.
-
- Handle 0x0000, DMI type 0, 26 bytes
- BIOS Information
- Vendor: American Megatrends Inc.
- Version: 3.2
- Release Date: 10/18/2019
- Address: 0xF0000
- Runtime Size: 64 kB
- ROM Size: 64 MB
- Characteristics:
- PCI is supported
- BIOS is upgradeable
- BIOS shadowing is allowed
- Boot from CD is supported
- Selectable boot is supported
- BIOS ROM is socketed
- EDD is supported
- 5.25"/1.2 MB floppy services are supported (int 13h)
- 3.5"/720 kB floppy services are supported (int 13h)
- 3.5"/2.88 MB floppy services are supported (int 13h)
- Print screen service is supported (int 5h)
- Serial services are supported (int 14h)
- Printer services are supported (int 17h)
- ACPI is supported
- USB legacy is supported
- BIOS boot specification is supported
- Targeted content distribution is supported
- UEFI is supported
- BIOS Revision: 5.14
-
- Handle 0x0001, DMI type 1, 27 bytes
- System Information
- Manufacturer: Supermicro
- Product Name: SYS-7049GP-TRT
- Version: 0123456789
- Serial Number: S291427X8332242
- UUID: 00000000-0000-0000-0000-AC1F6B8A8DB6
- Wake-up Type: Power Switch
- SKU Number: To be filled by O.E.M.
- Family: To be filled by O.E.M.
-
- Handle 0x0002, DMI type 2, 15 bytes
- Base Board Information
- Manufacturer: Supermicro
- Product Name: X11DPG-QT
- Version: 1.02
- Serial Number: VM183S014930
- Asset Tag: To be filled by O.E.M.
- Features:
- Board is a hosting board
- Board is replaceable
- Location In Chassis: To be filled by O.E.M.
- Chassis Handle: 0x0003
- Type: Motherboard
- Contained Object Handles: 0
-
- Handle 0x0003, DMI type 3, 22 bytes
- Chassis Information
- Manufacturer: Supermicro
- Type: Other
- Lock: Not Present
- Version: 0123456789
- Serial Number: C7470KH06A20167
- Asset Tag: To be filled by O.E.M.
- Boot-up State: Safe
- Power Supply State: Safe
- Thermal State: Safe
- Security Status: None
- OEM Information: 0x00000000
-
- Handle 0x0050, DMI type 4, 48 bytes
- Processor Information
- Socket Designation: CPU1
- Type: Central Processor
- Family: Xeon
- Manufacturer: Intel(R) Corporation
- ID: 54 06 05 00 FF FB EB BF
- Signature: Type 0, Family 6, Model 85, Stepping 4
- Flags:
- FPU (Floating-point unit on-chip)
- VME (Virtual mode extension)
- DE (Debugging extension)
- PSE (Page size extension)
- TSC (Time stamp counter)
- MSR (Model specific registers)
- PAE (Physical address extension)
- MCE (Machine check exception)
- CX8 (CMPXCHG8 instruction supported)
- APIC (On-chip APIC hardware supported)
- SEP (Fast system call)
- MTRR (Memory type range registers)
- PGE (Page global enable)
- MCA (Machine check architecture)
- CMOV (Conditional move instruction supported)
- PAT (Page attribute table)
- PSE-36 (36-bit page size extension)
- CLFSH (CLFLUSH instruction supported)
- DS (Debug store)
- ACPI (ACPI supported)
- MMX (MMX technology supported)
- FXSR (FXSAVE and FXSTOR instructions supported)
- SSE (Streaming SIMD extensions)
- SSE2 (Streaming SIMD extensions 2)
- SS (Self-snoop)
- HTT (Multi-threading)
- TM (Thermal monitor supported)
- PBE (Pending break enabled)
- Version: Intel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz
- Voltage: 1.6 V
- External Clock: 100 MHz
- Max Speed: 4000 MHz
- Current Speed: 2500 MHz
- Status: Populated, Enabled
- Upgrade: Other
- L1 Cache Handle: 0x004D
- L2 Cache Handle: 0x004E
- L3 Cache Handle: 0x004F
- Serial Number: Not Specified
- Asset Tag: UNKNOWN
- Part Number: Not Specified
- Core Count: 28
- Core Enabled: 28
- Thread Count: 56
- Characteristics:
- 64-bit capable
- Multi-Core
- Hardware Thread
- Execute Protection
- Enhanced Virtualization
- Power/Performance Control
-
-
- Handle 0x0054, DMI type 4, 48 bytes
- Processor Information
- Socket Designation: CPU2
- Type: Central Processor
- Family: Xeon
- Manufacturer: Intel(R) Corporation
- ID: 54 06 05 00 FF FB EB BF
- Signature: Type 0, Family 6, Model 85, Stepping 4
- Flags:
- FPU (Floating-point unit on-chip)
- VME (Virtual mode extension)
- DE (Debugging extension)
- PSE (Page size extension)
- TSC (Time stamp counter)
- MSR (Model specific registers)
- PAE (Physical address extension)
- MCE (Machine check exception)
- CX8 (CMPXCHG8 instruction supported)
- APIC (On-chip APIC hardware supported)
- SEP (Fast system call)
- MTRR (Memory type range registers)
- PGE (Page global enable)
- MCA (Machine check architecture)
- CMOV (Conditional move instruction supported)
- PAT (Page attribute table)
- PSE-36 (36-bit page size extension)
- CLFSH (CLFLUSH instruction supported)
- DS (Debug store)
- ACPI (ACPI supported)
- MMX (MMX technology supported)
- FXSR (FXSAVE and FXSTOR instructions supported)
- SSE (Streaming SIMD extensions)
- SSE2 (Streaming SIMD extensions 2)
- SS (Self-snoop)
- HTT (Multi-threading)
- TM (Thermal monitor supported)
- PBE (Pending break enabled)
- Version: Intel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz
- Voltage: 1.6 V
- External Clock: 100 MHz
- Max Speed: 4000 MHz
- Current Speed: 2500 MHz
- Status: Populated, Enabled
- Upgrade: Other
- L1 Cache Handle: 0x0051
- L2 Cache Handle: 0x0052
- L3 Cache Handle: 0x0053
- Serial Number: Not Specified
- Asset Tag: UNKNOWN
- Part Number: Not Specified
- Core Count: 28
- Core Enabled: 28
- Thread Count: 56
- Characteristics:
- 64-bit capable
- Multi-Core
- Hardware Thread
- Execute Protection
- Enhanced Virtualization
- Power/Performance Control
-```
-
-## Xeon Skx Server BIOS Configuration
-
-### Boot Feature
-
-```
- | Quiet Boot [Enabled] |Boot option |
- | | |
- | Option ROM Messages [Force BIOS] | |
- | Bootup NumLock State [On] | |
- | Wait For "F1" If Error [Enabled] | |
- | INT19 Trap Response [Immediate] | |
- | Re-try Boot [Disabled] | |
- | Install Windows 7 USB support [Disabled] | |
- | Port 61h Bit-4 Emulation [Disabled] | |
- | | |
- | Power Configuration | |
- | Watch Dog Function [Disabled] | |
- | Restore on AC Power Loss [Last State] | |
- | Power Button Function [Instant Off] | |
- | Throttle on Power Fail [Disabled] | |
-```
-
-### CPU Configuration
-
-```
- | Processor Configuration |Enables Hyper Threading |
- | -------------------------------------------------- |(Software Method to |
- | Processor BSP Revision 50654 - SKX H0 |Enable/Disable Logical |
- | Processor Socket CPU1 | CPU2 |Processor threads. |
- | Processor ID 00050654* | 000506... | |
- | Processor Frequency 2.500GHz | 2.500GHz | |
- | Processor Max Ratio 19H | 19H | |
- | Processor Min Ratio 0AH | 0AH | |
- | Microcode Revision 02000054 | 02000054 | |
- | L1 Cache RAM 64KB | 64KB | |
- | L2 Cache RAM 1024KB | 1024KB | |
- | L3 Cache RAM 39424KB | 39424KB | |
- | Processor 0 Version | |
- | Intel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz | |
- | Processor 1 Version | |
- | Intel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz | |
- | | |
- | Hyper-Threading [ALL] [Enable] | |
- | Core Enabled 0 | |
- | Monitor/Mwait [Auto] | |
- | Execute Disable Bit [Enable] | |
- | Intel Virtualization Technology [Enable] | |
- | PPIN Control [Unlock/Enable] | |
- | Hardware Prefetcher [Enable] | |
- | Adjacent Cache Prefetch [Enable] | |
- | DCU Streamer Prefetcher [Enable] | |
- | DCU IP Prefetcher [Enable] | |
- | LLC Prefetch [Disable] | |
- | Extended APIC [Disable] | |
- | AES-NI [Enable] | |
- |> Advanced Power Management Configuration | |
-```
-
-#### Advanced Power Management Configuration
-
-```
- | Advanced Power Management Configuration |Switch CPU Power Management |
- | -------------------------------------------------- |profile |
- | Power Technology [Custom] | |
- | Power Performance Tuning [BIOS Controls EPB] | |
- | ENERGY_PERF_BIAS_CFG mode [Maximum Performance] | |
- |> CPU P State Control | |
- |> Hardware PM State Control | |
- |> CPU C State Control | |
- |> Package C State Control | |
- |> CPU T State Control | |
-```
-
-##### CPU P State Control
-
-```
- | CPU P State Control |Enable/Disable EIST |
- | |(P-States) |
- | SpeedStep (Pstates) [Disable] | |
- | EIST PSD Function [HW_ALL] | |
-```
-
-##### Hardware PM State Control
-
-```
- | Hardware PM State Control |Disable: Hardware chooses a |
- | |P-state based on OS Request |
- | Hardware P-States [Disable] |(Legacy P-States) |
- | |Native Mode:Hardware |
- | |chooses a P-state based on |
- | |OS guidance |
- | |Out of Band Mode:Hardware |
- | |autonomously chooses a |
- | |P-state (no OS guidance) |
-```
-
-##### CPU C State Control
-
-```
- | CPU C State Control |Autonomous Core C-State |
- | |Control |
- | Autonomous Core C-State [Disable] | |
- | CPU C6 report [Disable] | |
- | Enhanced Halt State (C1E) [Disable] | |
-```
-
-##### Package C State Control
-
-```
- | Package C State Control |Package C State limit |
- | | |
- | Package C State [C0/C1 state] | |
-```
-
-##### CPU T State Control
-
-```
- | CPU T State Control |Enable/Disable Software |
- | |Controlled T-States |
- | Software Controlled T-States [Disable] | |
-```
-
-#### Chipset Configuration
-
-```
- | WARNING: Setting wrong values in below sections may cause |North Bridge Parameters |
- | system to malfunction. | |
- |> North Bridge | |
- |> South Bridge | |
-```
-
-##### North Bridge
-
-```
- |> UPI Configuration |Displays and provides |
- |> Memory Configuration |option to change the UPI |
- |> IIO Configuration |Settings |
-```
-
-##### UPI Configuration
-
-```
- | UPI Configuration |Choose Topology Precedence |
- | -------------------------------------------------- |to degrade features if |
- | Number of CPU 2 |system options are in |
- | Number of Active UPI Link 3 |conflict or choose Feature |
- | Current UPI Link Speed Fast |Precedence to degrade |
- | Current UPI Link Frequency 10.4 GT/s |topology if system options |
- | UPI Global MMIO Low Base / Limit 90000000 / FBFFFFFF |are in conflict. |
- | UPI Global MMIO High Base / Limit 0000000000000000 / ... | |
- | UPI Pci-e Configuration Base / Size 80000000 / 10000000 | |
- | Degrade Precedence [Topology Precedence] | |
- | Link L0p Enable [Disable] | |
- | Link L1 Enable [Disable] | |
- | IO Directory Cache (IODC) [Auto] | |
- | SNC [Disable] | |
- | XPT Prefetch [Disable] | |
- | KTI Prefetch [Enable] | |
- | Local/Remote Threshold [Auto] | |
- | Stale AtoS [Disable] | |
- | LLC dead line alloc [Enable] | |
- | Isoc Mode [Auto] | |
-```
-
-##### Memory Configuration
-
-```
- | |POR - Enforces Plan Of |
- | -------------------------------------------------- |Record restrictions for |
- | Integrated Memory Controller (iMC) |DDR4 frequency and voltage |
- | -------------------------------------------------- |programming. Disable - |
- | |Disables this feature. |
- | Enforce POR [POR] | |
- | PPR Type [Hard PPR] | |
- | Enhanced PPR [Disable] | |
- | Operation Mode [Test and Repair] | |
- | Memory Frequency [2933] | |
- | Data Scrambling for DDR4 [Auto] | |
- | tCCD_L Relaxation [Auto] | |
- | tRWSR Relaxation [Disable] | |
- | tRFC Optimization for 16Gb Based DIMM [Force 550ns] | |
- | 2x Refresh [Auto] | |
- | Page Policy [Auto] | |
- | IMC Interleaving [2-way Interleave] | |
- |> Memory Topology | |
- |> Memory RAS Configuration | |
-```
-
-##### IIO Configuration
-
-```
- | IIO Configuration |Expose IIO DFX devices and |
- | -------------------------------------------------- |other CPU devices like PMON |
- | | |
- | EV DFX Features [Disable] | |
- |> CPU1 Configuration | |
- |> CPU2 Configuration | |
- |> IOAT Configuration | |
- |> Intel. VT for Directed I/O (VT-d) | |
- |> Intel. VMD technology | |
- | | |
- | IIO-PCIE Express Global Options | |
- | ======================================== | |
- | PCI-E Completion Timeout Disable [No] | |
-```
-
-##### CPU1 Configuration
-
-```
- | IOU0 (IIO PCIe Br1) [Auto] |Selects PCIe port |
- | IOU1 (IIO PCIe Br2) [Auto] |Bifurcation for selected |
- | IOU2 (IIO PCIe Br3) [Auto] |slot(s) |
- |> CPU1 SLOT2 PCI-E 3.0 X16 | |
- |> CPU1 SLOT4 PCI-E 3.0 X16 | |
- |> CPU1 SLOT9 PCI-E 3.0 X16 | |
-```
-
-##### CPU2 Configuration
-
-```
- | IOU0 (IIO PCIe Br1) [Auto] |Selects PCIe port |
- | IOU1 (IIO PCIe Br2) [Auto] |Bifurcation for selected |
- | IOU2 (IIO PCIe Br3) [Auto] |slot(s) |
- |> CPU2 SLOT6 PCI-E 3.0 X16 | |
- |> CPU2 SLOT8 PCI-E 3.0 X16 | |
- |> CPU2 SLOT10 PCI-E 3.0 X16 | |
-```
-
-#### South Bridge
-
-```
- | |Enables Legacy USB support. |
- | USB Module Version 21 |AUTO option disables legacy |
- | |support if no USB devices |
- | USB Devices: |are connected. DISABLE |
- | 1 Keyboard, 1 Mouse, 1 Hub |option will keep USB |
- | |devices available only for |
- | Legacy USB Support [Enabled] |EFI applications. |
- | XHCI Hand-off [Enabled] | |
- | Port 60/64 Emulation [Enabled] | |
- | PCIe PLL SSC [Disable] | |
- | Real USB Wake Up [Enabled] | |
- | Front USB Wake Up [Enabled] | |
- | | |
- | Azalia [Auto] | |
- | Azalia PME Enable [Disabled] | |
-```
-
-### PCIe/PCI/PnP Configuration
-
-```
- | PCI Bus Driver Version A5.01.18 |Enables or Disables 64bit |
- | |capable Devices to be |
- | PCI Devices Common Settings: |Decoded in Above 4G Address |
- | Above 4G Decoding [Enabled] |Space (Only if System |
- | SR-IOV Support [Enabled] |Supports 64 bit PCI |
- | ARI Support [Enabled] |Decoding). |
- | MMIO High Base [56T] | |
- | MMIO High Granularity Size [256G] | |
- | Maximum Read Request [Auto] | |
- | MMCFG Base [2G] | |
- | NVMe Firmware Source [Vendor Defined Fi...] | |
- | VGA Priority [Onboard] | |
- | CPU1 SLOT2 PCI-E 3.0 X16 OPROM [Legacy] | |
- | CPU1 SLOT4 PCI-E 3.0 X16 OPROM [Legacy] | |
- | CPU2 SLOT6 PCI-E 3.0 X16 OPROM [Legacy] | |
- | CPU2 SLOT8 PCI-E 3.0 X16 OPROM [Legacy] | |
- | CPU1 SLOT9 PCI-E 3.0 X16 OPROM [Legacy] | |
- | CPU2 SLOT10 PCI-E 3.0 X16 OPROM [Legacy] | |
- | CPU2 SLOT11 PCI-E 3.0 X4(IN X8) OPROM [Legacy] | |
- | M.2 CONNECTOR OPROM [Legacy] | |
- | Onboard LAN1 Option ROM [Legacy] | |
- | Onboard LAN2 Option ROM [Disabled] | |
- | Onboard Video Option ROM [Legacy] | |
- |> Network Stack Configuration | |
-```
-
-### ACPI Settings
-
-```
- | ACPI Settings |Enable or Disable Non |
- | |uniform Memory Access |
- | NUMA [Enabled] |(NUMA). |
- | WHEA Support [Enabled] | |
- | High Precision Event Timer [Enabled] | |
-```
-
-## Xeon Skx Server Firmware Inventory
-
-```
-Host. IPMI IP. BMC. BIOS. CPLD. Aptio SU. CPU Microcode. PCI Bus. ME Operation FW. X710 Firmware. XXV710 Firmware. i40e.
-s1-t11-sut1. 10.30.50.47. 1.39. 2.1. 03.B1.03. 2.19.1268. 0200005e. A5.01.12. 4.0.4.294. 6.01 0x800034af 1.1747.0. N/A. 2.8.20-k.
-s2-t12-sut1. 10.30.50.48. 1.39. 2.0b. 03.B1.03. 2.19.1268. 0200005e. A5.01.12. 4.0.4.294. 6.01 0x800034af 1.1747.0. N/A. 2.8.20-k.
-s3-t21-sut1. 10.30.50.41. 1.39. 3.2. 03.B1.03. 2.19.1268. 02000065. A5.01.18. 4.0.4.294. 8.30 0x8000a49a 1.2926.0. 8.30 0x8000a485 1.2926.0. 2.17.15.
-s4-t21-tg1. 10.30.50.42. 1.39. 3.2. 03.B1.03. 2.19.1268. 02000065. A5.01.18. 4.0.4.294. 8.00 0x80008b80 1.2007.0. 8.00 0x80008c1a 1.2007.0. 2.14.13.
-s5-t22-sut1. 10.30.50.49. 1.53. 3.2. 03.B1.03. 2.19.1268. 02000065. A5.01.18. 4.0.4.294. 8.30 0x8000a49a 1.2926.0. 8.30 0x8000a485 1.2926.0. 2.17.15.
-s6-t22-tg1. 10.30.50.50. 1.53. 3.2. 03.B1.03. 2.19.1268. 02000065. A5.01.18. 4.0.4.294. 8.00 0x80008b80 1.2007.0. 8.00 0x80008c1a 1.2007.0. 2.14.13.
-s7-t23-sut1. 10.30.50.51. 1.53. 3.2. 03.B1.03. 2.19.1268. 02000065. A5.01.18. 4.0.4.294. 8.30 0x8000a49a 1.2926.0. 8.30 0x8000a485 1.2926.0. 2.17.15.
-s8-t23-tg1. 10.30.50.52. 1.39. 3.2. 03.B1.03. 2.19.1268. 02000065. A5.01.18. 4.0.4.294. 8.00 0x80008b80 1.2007.0. 8.00 0x80008c1a 1.2007.0. 2.14.13.
-s9-t24-sut1. 10.30.50.53. 1.39. 3.2. 03.B1.03. 2.19.1268. 02000065. A5.01.18. 4.0.4.294. 8.30 0x8000a49a 1.2926.0. 8.30 0x8000a485 1.2926.0. 2.17.15.
-s10-t24-tg1. 10.30.50.54. 1.39. 3.2. 03.B1.03. 2.19.1268. 02000065. A5.01.18. 4.0.4.294. 8.00 0x80008b80 1.2007.0. 8.00 0x80008c1a 1.2007.0. 2.14.13.
-s11-t31-sut1. 10.30.50.43. 1.39. 3.2. 03.B1.03. 2.19.1268. 02000065. A5.01.18. 4.0.4.294. 8.30 0x8000a49a 1.2926.0. 8.30 0x8000a485 1.2926.0. 2.17.15.
-s12-t31-sut2. 10.30.50.44. 1.39. 3.2. 03.B1.03. 2.19.1268. 02000065. A5.01.18. 4.0.4.294. 8.30 0x8000a49a 1.2926.0. 8.30 0x8000a485 1.2926.0. 2.17.15.
-s13-t31-tg1. 10.30.50.45. 1.39. 3.2. 03.B1.03. 2.19.1268. 02000065. A5.01.18. 4.0.4.294. 8.00 0x80008b80 1.2007.0. 8.00 0x80008c1a 1.2007.0. 2.14.13.
-s14-t32-sut1. 10.30.50.55. 1.39. 3.2. 03.B1.03. 2.19.1268. 02000065. A5.01.18. 4.0.4.294. 8.30 0x8000a49a 1.2926.0. 8.30 0x8000a485 1.2926.0. 2.17.15.
-s15-t32-sut2. 10.30.50.56. 1.39. 3.2. 03.B1.03. 2.19.1268. 02000065. A5.01.18. 4.0.4.294. 8.30 0x8000a49a 1.2926.0. 8.30 0x8000a485 1.2926.0. 2.17.15.
-s16-t32-tg1. 10.30.50.57. 1.39. 3.2. 03.B1.03. 2.19.1268. 02000065. A5.01.18. 4.0.4.294. 8.00 0x80008b80 1.2007.0. 8.00 0x80008c1a 1.2007.0. 2.14.13.
-s19-t33t211-sut1. 10.30.50.46. 1.39. 3.2. 03.B1.03. 2.19.1268. 02000065. A5.01.18. 4.0.4.294. 8.00 0x80008b80 1.2007.0. 8.00 0x80008c1a 1.2007.0. 2.17.15.
-s28-t26t35-tg1. 10.30.55.10. 1.39. 3.2. 03.B1.03. 2.19.1268. 02000065. A5.01.18. 4.0.4.294. 8.00 0x80008b80 1.2007.0. N/A. 2.14.13.
-```