aboutsummaryrefslogtreecommitdiffstats
path: root/docs
diff options
context:
space:
mode:
Diffstat (limited to 'docs')
-rw-r--r--docs/content/infrastructure/fdio_dc_testbed_specifications.md86
1 files changed, 59 insertions, 27 deletions
diff --git a/docs/content/infrastructure/fdio_dc_testbed_specifications.md b/docs/content/infrastructure/fdio_dc_testbed_specifications.md
index 3ca81cf796..439cfc31dd 100644
--- a/docs/content/infrastructure/fdio_dc_testbed_specifications.md
+++ b/docs/content/infrastructure/fdio_dc_testbed_specifications.md
@@ -129,7 +129,7 @@ Used for FD.io performance tests.
### 3-Node-Altra Arm Ampere (3n-alt)
Each 3-Node-Altra testbed includes two SUTs (Server-Type-E23) and one
-TG (Server-Type-F4) connected in a 3-node circular topology
+TG (Server-Type-E32) connected in a 3-node circular topology
([Server Types](#server-types)).
Used for FD.io performance tests.
@@ -381,7 +381,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
11. **Server-Type-E11**: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
- - Quantity: 2
+ - Quantity: 2.
- Physical connectivity:
- IPMI and host management ports.
- NIC ports connected into 1-node topologies.
@@ -400,7 +400,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
12. **Server-Type-E21**: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
- - Quantity: 2
+ - Quantity: 2.
- Physical connectivity:
- IPMI(?) and host management ports.
- NIC ports connected into 3-node topology.
@@ -414,7 +414,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot6 11:00.xx: x520-2p10GE Intel.
13. **Server-Type-E22**: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
- - Quantity: 1
+ - Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
- NIC ports connected into 2-node topologies.
@@ -431,7 +431,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
14. **Server-Type-E23**: Purpose - Altra Arm Ampere SUT for FD.io performance testing.
- - Quantity: 2
+ - Quantity: 2.
- Physical connectivity:
- IPMI and host management ports.
- NIC ports connected into 3-node topologies.
@@ -443,10 +443,12 @@ FD.io CSIT lab contains following server types:
- RAM Memory: 16* 8GB DDR4-3200MT/s
- Disks: 2* 960GB SSD Samsung M.2 NVMe PM983
- NICs configuration:
- - Numa0:
+ - Numa0: (x16, x16 PCIe4.0 lanes)
- PCIe Slot1 0004:04:00.x: xl710-QDA2-2p40GE Intel.
+ - PCIe Slot8 0001:00:00.x: ConnectX6-2p100GE Mellanox.
- Numa1:
- no cards.
+
15. **Server-Type-E24**: Purpose - Altra Arm Ampere for FD.io build.
- Quantity: 2.
- Physical connectivity:
@@ -459,8 +461,8 @@ FD.io CSIT lab contains following server types:
- RAM Memory: 12* 16GB DDR4-3200MT/s
- Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
-16. **Server-Type-E31**: Purpose - Skylake Xeon TG for FD.io performance testing.
- - Quantity: 1
+16. **Server-Type-E31**: Purpose - Skylake Xeon Shared TG for FD.io performance testing.
+ - Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
- NIC ports connected into 2-node and 3-node topologies.
@@ -480,7 +482,28 @@ FD.io CSIT lab contains following server types:
- PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
- PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
-17. **Server-Type-F1**: Purpose - Icelake Xeon SUT for FD.io performance testing.
+17. **Server-Type-E32**: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
+ - Quantity: 1.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 2-node and/or 3-node testbed topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-740GP-TNRT.
+ - Motherboard: Super X12DPG-QT6.
+ - Processors: 2* Intel Platinum 8358 2.6 GHz.
+ - RAM Memory: 16* 16GB DDR4-3200.
+ - Disks: 2* 960GB SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe4.0 lanes)
+ - PCIe Slot2 4b:00.xx: xxv710-DA2-2p25GE Intel.
+ - PCIe Slot4 31:00.xx: xl710-QDA2-2p40GE Intel.
+ - PCIe Slot9 ff:00.xx: empty.
+ - Numa1: (x16, x16, x16 PCIe4.0 lanes)
+ - PCIe Slot6 ca:00.xx: e810-XXVDA4-4p25GE Intel.
+ - PCIe Slot8 b1:00.xx: e810-2CQDA2-2p100GE Intel.
+ - PCIe Slot10 ff:00.xx: empty.
+
+18. **Server-Type-F1**: Purpose - Icelake Xeon SUT for FD.io performance testing.
- Quantity: 8.
- Physical connectivity:
- IPMI and host management ports.
@@ -501,7 +524,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-18. **Server-Type-F2**: Purpose - Icelake Xeon TG for FD.io performance testing.
+19. **Server-Type-F2**: Purpose - Icelake Xeon TG for FD.io performance testing.
- Quantity: 3.
- Physical connectivity:
- IPMI and host management ports.
@@ -522,7 +545,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-19. **Server-Type-F3**: Purpose - Icelake Xeon TG for FD.io performance testing.
+20. **Server-Type-F3**: Purpose - Icelake Xeon TG for FD.io performance testing.
- Quantity: 3.
- Physical connectivity:
- IPMI and host management ports.
@@ -542,8 +565,9 @@ FD.io CSIT lab contains following server types:
- PCIe Slot6 86:00.xx: empty.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-20. **Server-Type-F4**: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
- - Quantity: 3.
+
+21. **Server-Type-F4**: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
+ - Quantity: 2.
- Physical connectivity:
- IPMI and host management ports.
- NIC ports connected into 2-node and/or 3-node testbed topologies.
@@ -555,15 +579,15 @@ FD.io CSIT lab contains following server types:
- Disks: 2* 960GB SATA SSD.
- NICs configuration:
- Numa0: (x16, x16, x16 PCIe4.0 lanes)
- - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
- - PCIe Slot4 3b:00.xx: empty.
- - PCIe Slot9 5e:00.xx: empty.
+ - PCIe Slot2 4b:00.xx: xxv710-DA2-2p25GE Intel.
+ - PCIe Slot4 31:00.xx: empty.
+ - PCIe Slot9 ff:00.xx: empty.
- Numa1: (x16, x16, x16 PCIe4.0 lanes)
- - PCIe Slot6 86:00.xx: e810-XXVDA4-4p25GE Intel.
- - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel.
- - PCIe Slot10 d8:00.xx: empty.
+ - PCIe Slot6 ca:00.xx: e810-XXVDA4-4p25GE Intel.
+ - PCIe Slot8 b1:00.xx: e810-2CQDA2-2p100GE Intel.
+ - PCIe Slot10 ff:00.xx: empty.
-21. **Server-Type-G1**: Purpose - SnowRidge Atom SUT for FD.io performance testing.
+22. **Server-Type-G1**: Purpose - SnowRidge Atom SUT for FD.io performance testing.
- Quantity: 2
- Physical connectivity:
- IPMI and host management ports.
@@ -578,7 +602,7 @@ FD.io CSIT lab contains following server types:
- Numa0: (x16, PCIe3.0 lane)
- PCIe BuiltIn ec:00.xx: e810-XXVDA4-4p25GE Intel.
-22. **Server-Type-H1**: Purpose - SapphireRapids Xeon SUT for FD.io full system performance testing.
+23. **Server-Type-H1**: Purpose - SapphireRapids Xeon SUT for FD.io full system performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
@@ -599,7 +623,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
- PCIe Slot11 d8:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
-23. **Server-Type-H2**: Purpose - SapphireRapids Xeon TG for FD.io full system performance testing.
+24. **Server-Type-H2**: Purpose - SapphireRapids Xeon TG for FD.io full system performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
@@ -620,7 +644,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
- PCIe Slot11 d8:00.xx: empty.
-24. **Server-Type-H3**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.
+25. **Server-Type-H3**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
@@ -641,7 +665,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot9 af:00.xx: e810-XXVDA4-4p25GE Intel.
- PCIe Slot11 d8:00.xx: empty.
-25. **Server-Type-H4**: Purpose - SapphireRapids Xeon TG for FD.io performance testing.
+26. **Server-Type-H4**: Purpose - SapphireRapids Xeon TG for FD.io performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
@@ -662,7 +686,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot9 af:00.xx: empty.
- PCIe Slot11 d8:00.xx: empty.
-26. **Server-Type-H5**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.
+27. **Server-Type-H5**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.
- Quantity: 2.
- Physical connectivity:
- IPMI and host management ports.
@@ -683,7 +707,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot9 af:00.xx: empty.
- PCIe Slot11 d8:00.xx: empty.
-27. **Server-Type-H6**: Purpose - SapphireRapids Xeon TG for FD.io performance testing.
+28. **Server-Type-H6**: Purpose - SapphireRapids Xeon TG for FD.io performance testing.
- Quantity: 2.
- Physical connectivity:
- IPMI and host management ports.
@@ -1210,6 +1234,8 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
- portnames:
- s62-t34-sut1-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
- s62-t34-sut1-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
+ - s62-t34-sut1-c8/p1 - 100GE-port1 ConnectX6-2p100GE Mellanox.
+ - s62-t34-sut1-c8/p2 - 100GE-port1 ConnectX6-2p100GE Mellanox.
- SUT [Server-Type-E23]:
- testbedname: testbed34.
- hostname: s63-t34-sut2.
@@ -1218,7 +1244,9 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
- portnames:
- s63-t34-sut2-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
- s63-t34-sut2-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
-- TG [Server-Type-F4]:
+ - s63-t34-sut2-c8/p1 - 100GE-port1 ConnectX6-2p100GE Mellanox.
+ - s63-t34-sut2-c8/p2 - 100GE-port1 ConnectX6-2p100GE Mellanox.
+- TG [Server-Type-E32]:
- testbedname: testbed34.
- hostname: s64-t34-tg1.
- IPMI IP: 10.30.50.74
@@ -1747,6 +1775,10 @@ To be completed.
- s64-t34-tg1-c4/p1 - s62-t34-sut1-c1/p2.
- s62-t34-sut1-c1/p1 - s63-t34-sut2-c1/p2.
- s63-t34-sut2-c1/p1 - s64-t34-tg1-c4/p2.
+ - ring2 100GE-ports ConnectX6-2p100GE Mellanox on SUTs:
+ - s64-t34-tg1-c8/p1 - s62-t34-sut1-c8/p2.
+ - s62-t34-sut1-c8/p1 - s63-t34-sut2-c8/p2.
+ - s63-t34-sut2-c8/p1 - s64-t34-tg1-c8/p2.
```
### 3-Node-Icelake (3n-icx)