diff options
Diffstat (limited to 'docs')
-rw-r--r-- | docs/lab/fdio-dc-inventory-vexxhost.md | 37 | ||||
-rw-r--r-- | docs/lab/testbed_specifications.md | 659 |
2 files changed, 577 insertions, 119 deletions
diff --git a/docs/lab/fdio-dc-inventory-vexxhost.md b/docs/lab/fdio-dc-inventory-vexxhost.md index c5b129ebb8..fe4169e5fa 100644 --- a/docs/lab/fdio-dc-inventory-vexxhost.md +++ b/docs/lab/fdio-dc-inventory-vexxhost.md @@ -3,7 +3,8 @@ - [FD.io DC Vexxhost Inventory](#fdio-dc-vexxhost-inventory) - [Missing Equipment Inventory](#missing-equipment-inventory) - [YUL1 Inventory](#yul1-inventory) - - [Rack YUL1-9 (3016.9)](#rack-yul1-10-3016.9) + - [Rack YUL1-8 (3016.8)](#rack-yul1-8-3016.8) + - [Rack YUL1-9 (3016.9)](#rack-yul1-9-3016.9) - [Rack YUL1-10 (3016.10)](#rack-yul1-10-3016.10) - [Rack YUL1-11 (3016.11)](#rack-yul1-11-3016.11) - [Rack YUL1-12 (3016.12)](#rack-yul1-12-3016.12) @@ -36,6 +37,21 @@ ### YUL1 Inventory +#### Rack YUL1-8 (3016.8) +name,oper-status,testbed-id,role,model,s/n,mgmt-ip4,ipmi-ip4,rackid,rackunit +?,up,switch,uplink,?,?,?,?,3016.8,u47,?,? +s65-t37-sut1,up,t37,3n-icx,SYS-740GP-TNRT,???,10.30.51.75,10.30.50.75,3016.8,u42-u45 +s66-t37-sut2,up,t37,3n-icx,SYS-740GP-TNRT,???,10.30.51.76,10.30.50.76,3016.8,u38-u41 +s67-t37-tg1,up,t37,3n-icx,SYS-740GP-TNRT,???,10.30.51.77,10.30.50.77,3016.8,u34-u37 +s71-t212-sut1,up,t212,2n-icx,SYS-740GP-TNRT,???,10.30.51.81,10.30.50.81,3016.8,u30-u33 +s72-t212-tg1,up,t212,2n-icx,SYS-740GP-TNRT,???,10.30.51.82,10.30.50.82,3016.8,u26-u29 +s73-t213-sut1,up,t213,2n-icx,SYS-740GP-TNRT,???,10.30.51.83,10.30.50.83,3016.8,u22-u25 +s74-t213-tg1,up,t213,2n-icx,SYS-740GP-TNRT,???,10.30.51.84,10.30.50.84,3016.8,u18-u21 +s75-t214-sut1,up,t214,2n-icx,SYS-740GP-TNRT,???,10.30.51.85,10.30.50.85,3016.8,u14-u17 +s76-t214-tg1,up,t214,2n-icx,SYS-740GP-TNRT,???,10.30.51.86,10.30.50.86,3016.8,u10-u13 +s77-t215-sut1,up,t215,2n-icx,SYS-740GP-TNRT,???,10.30.51.87,10.30.50.87,3016.8,u6-u9 +s78-t215-tg1,up,t215,2n-icx,SYS-740GP-TNRT,???,10.30.51.88,10.30.50.88,3016.8,u2-u5 + #### Rack YUL1-9 (3016.9) name,oper-status,testbed-id,role,model,s/n,mgmt-ip4,ipmi-ip4,rackid,rackunit mtl1-5-lb4m,up,switch,uplink,?,?,?,?,3016.9,u47,?,? @@ -50,6 +66,7 @@ s19-t33t211-tg1,up,t33t211,3n-tsh/2n-tx2,SYS-7049GP-TRT,C7470KH06A20056,10.30.51 s27-t211-sut1,up,t211,2n-tx2,ThunderX2-9975,K61186073100003,10.30.51.69,10.30.50.69,3016.9,u13 s18-t33-sut2,up,t33,3n-tsh,HUAWEI-TAISHAN-2280,N/A,10.30.51.37,10.30.50.37,3016.9,u11-u12 s17-t33-sut1,up,t33,3n-tsh,HUAWEI-TAISHAN-2280,N/A,10.30.51.36,10.30.50.36,3016.9,u9-u10 +s79-t39t310-tg1,in-transit,t39t310,tbd,SYS-740GP-TNRT,???,10.30.51.89,10.30.50.89,3016.9,u5-u8 #### Rack YUL1-10 (3016.10) @@ -65,6 +82,7 @@ s7-t23-sut1,up,t23,2n-skx,SYS-7049GP-TRT,N/A,10.30.51.54,10.30.50.51,3016.10,u18 s8-t23-tg1,up,t23,2n-skx,SYS-7049GP-TRT,C7470KH06A20035,10.30.51.55,10.30.50.52,3016.10,u14-u17 s9-t24-sut1,up,t24,2n-skx,SYS-7049GP-TRT,C7470KH06A20055,10.30.51.56,10.30.50.53,3016.10,u10-u13 s10-t24-tg1,up,t24,2n-skx,SYS-7049GP-TRT,C7470KH06A20196,10.30.51.57,10.30.50.54,3016.10,u6-u9 +s80-t311t312-tg1,in-transit,t311t312,tbd,SYS-740GP-TNRT,???,10.30.51.90,10.30.50.90,3016.10,u2-u5 #### Rack YUL1-11 (3016.11) @@ -79,18 +97,21 @@ s56-t14-sut1,up,t14,1n-tx2,ThunderX2-9980,N/A,10.30.51.71,10.30.50.71,3016.11,u4 s41-nomad,up,nomad-cluster1,nomad-client,UCSC-C240-M4SX,FCH1950V1FQ,10.30.51.28,10.30.50.28,3016.11,u39-u40 s40-nomad,up,nomad-cluster1,nomad-client,UCSC-C240-M4SX,FCH2013V0HZ,10.30.51.30,10.30.50.30,3016.11,u37-u38 s39-nomad,up,nomad-cluster1,nomad-client,UCSC-C240-M4SX,FCH2013V0J2,10.30.51.29,10.30.50.29,3016.11,u35-u36 +s68-t38-sut1,up,t38,3n-icx,SYS-740GP-TNRT,???,10.30.51.78,10.30.50.78,3016.8,u31-u34 +s69-t38-sut2,up,t38,3n-icx,SYS-740GP-TNRT,???,10.30.51.79,10.30.50.79,3016.8,u27-u30 +s70-t38-tg1,up,t38,3n-icx,SYS-740GP-TNRT,???,10.30.51.80,10.30.50.80,3016.8,u23-u26 +s52-nomad,up,nomad-cluster1,nomad-client,ThunderX-88XX,N/A,10.30.51.65,10.30.50.65,3016.11,u21-u22 +s51-nomad,up,nomad-cluster1,nomad-client,ThunderX-88XX,N/A,10.30.51.66,10.30.50.66,3016.11,u21-u22 +s49-nomad,up,nomad-cluster1,nomad-client,ThunderX-88XX,N/A,10.30.51.67,10.30.50.67,3016.11,u21-u22 +s50-nomad,up,nomad-cluster1,nomad-client,ThunderX-88XX,N/A,10.30.51.68,10.30.50.68,3016.11,u21-u22 s42-nomad,up,nomad-cluster1,nomad-client,UCSC-C240-M4SX,FCH1950V1FN,10.30.51.22,10.30.50.22,3016.11,u19-u20 s43-nomad,up,nomad-cluster1,nomad-client,UCSC-C240-M4SX,FCH1950V1H5,10.30.51.24,10.30.50.24,3016.11,u17-u18 s44-nomad,up,nomad-cluster1,nomad-client,UCSC-C240-M4SX,FCH1950V1FS,10.30.51.25,10.30.50.25,3016.11,u15-u16 s45-nomad,up,nomad-cluster1,nomad-client,UCSC-C240-M4SX,FCH1950V1FL,10.30.51.26,10.30.50.26,3016.11,u13-u14 s55-t13-sut1,up,t13,1n-tx2,ThunderX2-9980,N/A,10.30.51.70,10.30.50.70,3016.11,u11-u12 -s52-nomad,up,nomad-cluster1,nomad-client,ThunderX-88XX,N/A,10.30.51.65,10.30.50.65,3016.11,u9-u10 -s51-nomad,up,nomad-cluster1,nomad-client,ThunderX-88XX,N/A,10.30.51.66,10.30.50.66,3016.11,u9-u10 -s49-nomad,up,nomad-cluster1,nomad-client,ThunderX-88XX,N/A,10.30.51.67,10.30.50.67,3016.11,u9-u10 -s50-nomad,up,nomad-cluster1,nomad-client,ThunderX-88XX,N/A,10.30.51.68,10.30.50.68,3016.11,u9-u10 -s62-t34-sut1,in-transit,t34,3n-alt,Ampere-TBD,TBD,10.30.51.72,10.30.50.72,3016.11,u7-8 -s63-t34-sut2,in-transit,t34,3n-alt,Ampere-TBD,TBD,10.30.51.73,10.30.50.73,3016.11,u5-6 -s64-t34-tg1,in-transit,t34,3n-alt,Intel-TBD,TBD,10.30.51.74,10.30.50.74,3016.11,u1-4 +s62-t34-sut1,in-transit,t34,3n-alt,Ampere-TBD,TBD,10.30.51.72,10.30.50.72,3016.11,u9-u10 +s63-t34-sut2,in-transit,t34,3n-alt,Ampere-TBD,TBD,10.30.51.73,10.30.50.73,3016.11,u7-u8 +s64-t34-tg1,in-transit,t34,3n-alt,Intel-TBD,TBD,10.30.51.74,10.30.50.74,3016.11,u3-u6 #### Rack YUL1-12 (3016.12) diff --git a/docs/lab/testbed_specifications.md b/docs/lab/testbed_specifications.md index d947e53b5d..30343aafc5 100644 --- a/docs/lab/testbed_specifications.md +++ b/docs/lab/testbed_specifications.md @@ -12,10 +12,12 @@ 1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx) 1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn) 1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2) + 1. [2-Node-Icelake Xeon Intel (2n-icx)](#2-node-icelake-xeon-intel-2n-icx) 1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx) 1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds) 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh) 1. [3-Node-Altra Arm Ampere (3n-alt)](#3-node-altra-arm-armpere-3n-alt) + 1. [3-Node-Icelake Xeon Intel (3n-icx)](#3-node-icelake-xeon-intel-3n-icx) 1. [Server Management](#server-management) 1. [Requirements](#requirements) 1. [Addressing](#addressing) @@ -35,10 +37,12 @@ 1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod) 1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod]) 1. [2-Node-ThunderX2 Servers (2n-tx2) PROD](#2-node-thunderx2-servers-2n-tx2-prod) + 1. [2-Node-Icelake Servers (2n-icx) TBD](#2-node-icelake-servers-2n-icx-tbd) 1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod) 1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify) 1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod) 1. [3-Node-Altra Servers (3n-alt) TBD](#3-node-altra-servers-3n-alt-tbd) + 1. [3-Node-Icelake Servers (3n-icx) TBD](#3-node-icelake-servers-3n-icx-tbd) 1. [Per Testbed Wiring](#per-testbed-wiring) 1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod) 1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod) @@ -49,10 +53,12 @@ 1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod) 1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod]) 1. [2-Node-ThunderX2 Wiring (2n-tx2) PROD](#2-node-thunderx2-wiring-2n-tx2-prod) + 1. [2-Node-Icelake Servers (2n-icx) TBD](#2-node-icelake-servers-2n-icx-tbd) 1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod) 1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo) 1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod) 1. [3-Node-Altra Wiring (3n-alt) TBD](#3-node-altra-wiring-3n-alt-tbd) + 1. [3-Node-Icelake Wiring (3n-icx) TBD](#3-node-icelake-wiring-3n-icx-tbd) 1. [Inventory](#inventory) 1. [Appliances](#appliances) 1. [Arm Servers](#arm-servers) @@ -71,23 +77,25 @@ hosted by LFN FD.io CSIT project. ### Summary List ``` - #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #alt #clx #zn2 - 1. 1-Node-Haswell nomad hsw na 4 4 0 4 0 0 0 0 0 0 0 0 0 - 2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0 0 0 - 3. 1-Node-ThunderX2 dev tx2 na 2 2 0 0 0 0 0 0 2 0 0 0 0 - 4. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 0 1 0 - 5. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0 0 0 - 6. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0 0 0 - 7. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0 0 0 - 8. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 0 6 0 - 9. 2-Node-ThunderX2 perf tx2 skx 1 1 .5 0 .5 0 0 0 1 0 0 0 0 -10. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 0 0 -11. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 0 0 -12. 3-Node-Taishan perf tsh skx 1 2 .5 0 .5 0 0 0 0 2 0 0 0 -13. 3-Node-Altra perf alt tbd 1 2 tbd 0 0 0 0 0 0 0 2 0 0 -14. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0 0 0 -15. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 0 0 2 - Totals: 26 33 15 4 19 1 2 3 3 2 2 7 2 + #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #alt #clx #zn2 #icx + 1. 1-Node-Haswell nomad hsw na 4 4 0 4 0 0 0 0 0 0 0 0 0 0 + 2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0 0 0 0 + 3. 1-Node-ThunderX2 dev tx2 na 2 2 0 0 0 0 0 0 2 0 0 0 0 0 + 4. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 0 1 0 0 + 5. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0 0 0 0 + 6. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0 0 0 0 + 7. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0 0 0 0 + 8. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 0 6 0 0 + 9. 2-Node-ThunderX2 perf tx2 skx 1 1 .5 0 .5 0 0 0 1 0 0 0 0 0 +10. 2-Node-Icelake perf icx icx 4 4 4 0 0 0 0 0 0 0 0 0 0 8 +11. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 0 0 0 +12. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 0 0 0 +13. 3-Node-Taishan perf tsh skx 1 2 .5 0 .5 0 0 0 0 2 0 0 0 0 +14. 3-Node-Altra perf alt icx 1 2 .5 0 0 0 0 0 0 0 2 0 0 .5 +15. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0 0 0 0 +16. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 0 0 2 0 +17. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 6 0 6 + Totals: 32 41 21.5 4 19 1 2 3 3 2 2 7 2 14.5 ``` ### 1-Node-Skylake Xeon Intel (1n-skx) @@ -151,6 +159,13 @@ one TG (Server-Type-E31) connected in a 2-node circular topology ([Server Types](#server-types)). Used for FD.io performance tests. +### 2-Node-Icelake Xeon Intel (2n-icx) + +Each 2-Node-Icelake testbed includes one SUT (Server-Type-F1) and +one TG (Server-Type-F2) connected in a 2-node circular topology +([Server Types](#server-types)). +Used for FD.io performance tests. + ### 3-Node-Haswell Xeon Intel (3n-hsw) Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one @@ -181,7 +196,14 @@ Used for FD.io performance tests. ### 3-Node-Altra Arm Ampere (3n-alt) Each 3-Node-Altra testbed includes two SUTs (Server-Type-E23) and one -TG (TBD Server-Type-xxx) connected in a 3-node circular topology +TG (Server-Type-F4) connected in a 3-node circular topology +([Server Types](#server-types)). +Used for FD.io performance tests. + +### 3-Node-Icelake Xeon Intel (3n-icx) + +Each 3-Node-Icelake testbed includes two SUTs (Server-Type-F1) and one +TG (Server-Type-F3) connected in a 3-node circular topology ([Server Types](#server-types)). Used for FD.io performance tests. @@ -286,7 +308,23 @@ Name | Comment 10.30.50.71 | s56-t14-sut1 10.30.50.72 | s62-t34-sut1 10.30.50.73 | s63-t34-sut2 -10.30.50.74 | s64-t34-tg1 +10.30.50.74 | s64-t34t36-tg1 +10.30.50.75 | s65-t37-sut1 +10.30.50.76 | s66-t37-sut2 +10.30.50.77 | s67-t37-tg1 +10.30.50.78 | s68-t38-sut1 +10.30.50.79 | s69-t38-sut2 +10.30.50.80 | s70-t38-tg1 +10.30.50.81 | s71-t212-sut1 +10.30.50.82 | s72-t212-tg1 +10.30.50.83 | s73-t213-sut1 +10.30.50.84 | s74-t213-tg1 +10.30.50.85 | s75-t214-sut1 +10.30.50.86 | s76-t214-tg1 +10.30.50.87 | s77-t215-sut1 +10.30.50.88 | s78-t215-tg1 +10.30.50.89 | s79-t39t310-tg1 +10.30.50.90 | s80-t311t312-tg1 10.30.50.255 | Broadcast 10.30.55.0 | network 10.30.55.1 | Router @@ -310,80 +348,95 @@ Name | Comment ### Management VLAN IP Addresses -Name | Comment -------------------------- | ------- -10.30.51.0 | network -10.30.51.1 | Router -10.30.51.2 | LF Reserved -10.30.51.3 | LF Reserved -10.30.51.4 | LF Reserved -10.30.51.5 | LF Reserved -10.30.51.6 | LF Reserved -10.30.51.7 | LF Reserved -10.30.51.8 | LF Reserved -10.30.51.15 | LF Reserved -10.30.51.22 | s42-nomad -10.30.51.24 | s43-nomad -10.30.51.25 | s44-nomad -10.30.51.26 | s45-nomad -10.30.51.28 | s41-nomad -10.30.51.29 | s39-nomad -10.30.51.30 | s40-nomad -10.30.51.36 | s17-t33-sut1 -10.30.51.37 | s18-t33-sut2 -10.30.51.38 | fdio-marvell-dev -10.30.51.39 | s53-nomad -10.30.51.40 | s54-nomad -10.30.51.44 | s3-t21-sut1 -10.30.51.45 | s4-t21-tg1 -10.30.51.46 | s11-t31-sut1 -10.30.51.47 | s12-t31-sut2 -10.30.51.48 | s13-t31-tg1 -10.30.51.49 | s19-t33t211-tg1 -10.30.51.50 | s1-t11-sut1 -10.30.51.51 | s2-t12-sut1 -10.30.51.52 | s5-t22-sut1 -10.30.51.53 | s6-t22-tg1 -10.30.51.54 | s7-t23-sut1 -10.30.51.55 | s8-t23-tg1 -10.30.51.56 | s9-t24-sut1 -10.30.51.57 | s10-t24-tg1 -10.30.51.58 | s14-t32-sut1 -10.30.51.59 | s15-t32-sut2 -10.30.51.60 | s16-t32-tg1 -10.30.51.61 | s25-t25-sut1 -10.30.51.62 | s26-t25-tg1 -10.30.51.65 | s52-nomad -10.30.51.66 | s51-nomad -10.30.51.67 | s49-nomad -10.30.51.68 | s50-nomad -10.30.51.69 | s27-t211-sut1 -10.30.51.70 | s55-t13-sut1 -10.30.51.71 | s56-t14-sut1 -10.30.51.72 | s62-t34-sut1 -10.30.51.73 | s63-t34-sut2 -10.30.51.74 | s64-t34-tg1 -10.30.51.75-10.30.51.254 | FREE -10.30.51.255 | Broadcast -10.32.8.0 | network -10.32.8.1 | Router -10.32.8.10 | s28-t26t35-tg1 -10.32.8.11 | s29-t26-sut1 -10.32.8.12 | s30-t35-sut1 -10.32.8.13 | s31-t35-sut2 -10.32.8.14 | s46-nomad -10.32.8.15 | s47-nomad -10.32.8.16 | s48-nomad -10.32.8.17 | s57-nomad -10.32.8.18 | s33-t27-sut1 -10.32.8.19 | s34-t27-tg1 -10.32.8.20 | s35-t28-sut1 -10.32.8.21 | s36-t28-tg1 -10.32.8.22 | s37-t29-sut1 -10.32.8.23 | s38-t29-tg1 -10.32.8.24 | s60-t210-sut1 -10.32.8.25 | s61-t210-tg1 -10.32.8.255 | Broadcast +Name | Comment +-------------| ------- +10.30.51.0 | network +10.30.51.1 | Router +10.30.51.2 | LF Reserved +10.30.51.3 | LF Reserved +10.30.51.4 | LF Reserved +10.30.51.5 | LF Reserved +10.30.51.6 | LF Reserved +10.30.51.7 | LF Reserved +10.30.51.8 | LF Reserved +10.30.51.15 | LF Reserved +10.30.51.22 | s42-nomad +10.30.51.24 | s43-nomad +10.30.51.25 | s44-nomad +10.30.51.26 | s45-nomad +10.30.51.28 | s41-nomad +10.30.51.29 | s39-nomad +10.30.51.30 | s40-nomad +10.30.51.36 | s17-t33-sut1 +10.30.51.37 | s18-t33-sut2 +10.30.51.38 | fdio-marvell-dev +10.30.51.39 | s53-nomad +10.30.51.40 | s54-nomad +10.30.51.44 | s3-t21-sut1 +10.30.51.45 | s4-t21-tg1 +10.30.51.46 | s11-t31-sut1 +10.30.51.47 | s12-t31-sut2 +10.30.51.48 | s13-t31-tg1 +10.30.51.49 | s19-t33t211-tg1 +10.30.51.50 | s1-t11-sut1 +10.30.51.51 | s2-t12-sut1 +10.30.51.52 | s5-t22-sut1 +10.30.51.53 | s6-t22-tg1 +10.30.51.54 | s7-t23-sut1 +10.30.51.55 | s8-t23-tg1 +10.30.51.56 | s9-t24-sut1 +10.30.51.57 | s10-t24-tg1 +10.30.51.58 | s14-t32-sut1 +10.30.51.59 | s15-t32-sut2 +10.30.51.60 | s16-t32-tg1 +10.30.51.61 | s25-t25-sut1 +10.30.51.62 | s26-t25-tg1 +10.30.51.65 | s52-nomad +10.30.51.66 | s51-nomad +10.30.51.67 | s49-nomad +10.30.51.68 | s50-nomad +10.30.51.69 | s27-t211-sut1 +10.30.51.70 | s55-t13-sut1 +10.30.51.71 | s56-t14-sut1 +10.30.51.72 | s62-t34-sut1 +10.30.51.73 | s63-t34-sut2 +10.30.51.74 | s64-t34t36-tg1 +10.30.51.75 | s65-t37-sut1 +10.30.51.76 | s66-t37-sut2 +10.30.51.77 | s67-t37-tg1 +10.30.51.78 | s68-t38-sut1 +10.30.51.79 | s69-t38-sut2 +10.30.51.80 | s70-t38-tg1 +10.30.51.81 | s71-t212-sut1 +10.30.51.82 | s72-t212-tg1 +10.30.51.83 | s73-t213-sut1 +10.30.51.84 | s74-t213-tg1 +10.30.51.85 | s75-t214-sut1 +10.30.51.86 | s76-t214-tg1 +10.30.51.87 | s77-t215-sut1 +10.30.51.88 | s78-t215-tg1 +10.30.51.89 | s79-t39t310-tg1 +10.30.51.90 | s80-t311t312-tg1 +10.30.51.255 | Broadcast +10.32.8.0 | network +10.32.8.1 | Router +10.32.8.10 | s28-t26t35-tg1 +10.32.8.11 | s29-t26-sut1 +10.32.8.12 | s30-t35-sut1 +10.32.8.13 | s31-t35-sut2 +10.32.8.14 | s46-nomad +10.32.8.15 | s47-nomad +10.32.8.16 | s48-nomad +10.32.8.17 | s57-nomad +10.32.8.18 | s33-t27-sut1 +10.32.8.19 | s34-t27-tg1 +10.32.8.20 | s35-t28-sut1 +10.32.8.21 | s36-t28-tg1 +10.32.8.22 | s37-t29-sut1 +10.32.8.23 | s38-t29-tg1 +10.32.8.24 | s60-t210-sut1 +10.32.8.25 | s61-t210-tg1 +10.32.8.255 | Broadcast ## Server Specifications @@ -764,6 +817,86 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel. - PCIe Slot10 d8:00.xx: x710-4p10GE Intel. +22. Server-Type-F1: Purpose - Icelake Xeon SUT for FD.io performance testing. + - Quantity: 8. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node or 3-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-740GP-TNRT. + - Motherboard: Super X12DPG-QT6. + - Processors: 2* Intel Platinum 8358 2.6 GHz. + - RAM Memory: 16* 16GB DDR4-3200. + - Disks: 2* 960GB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel. + - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel. + - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: empty. + - PCIe Slot8 af:00.xx: empty. + - PCIe Slot10 d8:00.xx: empty. +23. Server-Type-F2: Purpose - Icelake Xeon TG for FD.io performance testing. + - Quantity: 3. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-740GP-TNRT. + - Motherboard: Super X12DPG-QT6. + - Processors: 2* Intel Platinum 8358 2.6 GHz. + - RAM Memory: 16* 16GB DDR4-3200. + - Disks: 2* 960GB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel. + - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel. + - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel. + - PCIe Slot8 af:00.xx: empty. + - PCIe Slot10 d8:00.xx: empty. +24. Server-Type-F3: Purpose - Icelake Xeon TG for FD.io performance testing. + - Quantity: 3. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 3-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-740GP-TNRT. + - Motherboard: Super X12DPG-QT6. + - Processors: 2* Intel Platinum 8358 2.6 GHz. + - RAM Memory: 16* 16GB DDR4-3200. + - Disks: 2* 960GB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel. + - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel. + - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: empty. + - PCIe Slot8 af:00.xx: empty. + - PCIe Slot10 d8:00.xx: empty. +25. Server-Type-F4: Purpose - Icelake Xeon Shared TG for FD.io performance testing. + - Quantity: 3. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node and/or 3-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-740GP-TNRT. + - Motherboard: Super X12DPG-QT6. + - Processors: 2* Intel Platinum 8358 2.6 GHz. + - RAM Memory: 16* 16GB DDR4-3200. + - Disks: 2* 960GB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel. + - PCIe Slot4 3b:00.xx: empty. + - PCIe Slot9 5e:00.xx: empty. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: e810-XXVDA4-4p25GE Intel. + - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel. + - PCIe Slot10 d8:00.xx: empty. ``` ### Naming Convention @@ -1222,6 +1355,131 @@ Note: Server19 (TG) is shared between testbed33 & testbed211 - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE. ``` +#### 2-Node-Icelake Servers (2n-icx) TBD + +``` +- SUT [Server-Type-F1]: + - testbedname: testbed212. + - hostname: s71-t212-sut1. + - IPMI IP: 10.30.51.81 + - Host IP: 10.30.50.81 + - portnames: + - s71-t212-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s71-t212-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s71-t212-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s71-t212-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s71-t212-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s71-t212-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s71-t212-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s71-t212-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- TG [Server-Type-F2]: + - testbedname: testbed212. + - hostname: s72-t212-tg1. + - IPMI IP: 10.30.51.82 + - Host IP: 10.30.50.82 + - portnames: + - s72-t212-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s72-t212-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s72-t212-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s72-t212-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s72-t212-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s72-t212-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s72-t212-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s72-t212-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s72-t212-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s72-t212-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- SUT [Server-Type-F1]: + - testbedname: testbed213. + - hostname: s73-t213-sut1. + - IPMI IP: 10.30.51.83 + - Host IP: 10.30.50.83 + - portnames: + - s73-t213-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s73-t213-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s73-t213-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s73-t213-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s73-t213-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s73-t213-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s73-t213-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s73-t213-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- TG [Server-Type-F2]: + - testbedname: testbed213. + - hostname: s74-t213-tg1. + - IPMI IP: 10.30.51.84 + - Host IP: 10.30.50.84 + - portnames: + - s74-t213-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s74-t213-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s74-t213-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s74-t213-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s74-t213-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s74-t213-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s74-t213-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s74-t213-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s74-t213-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s74-t213-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- SUT [Server-Type-F1]: + - testbedname: testbed214. + - hostname: s75-t214-sut1. + - IPMI IP: 10.30.51.85 + - Host IP: 10.30.50.85 + - portnames: + - s75-t214-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s75-t214-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s75-t214-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s75-t214-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s75-t214-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s75-t214-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s75-t214-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s75-t214-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- TG [Server-Type-F2]: + - testbedname: testbed214. + - hostname: s76-t214-tg1. + - IPMI IP: 10.30.51.86 + - Host IP: 10.30.50.86 + - portnames: + - s76-t214-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s76-t214-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s76-t214-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s76-t214-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s76-t214-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s76-t214-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s76-t214-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s76-t214-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s76-t214-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s76-t214-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- SUT [Server-Type-F1]: + - testbedname: testbed215. + - hostname: s77-t215-sut1. + - IPMI IP: 10.30.51.87 + - Host IP: 10.30.50.87 + - portnames: + - s77-t215-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s77-t215-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s77-t215-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s77-t215-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s77-t215-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s77-t215-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s77-t215-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s77-t215-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- TG [Server-Type-F2]: + - testbedname: testbed215. + - hostname: s78-t215-tg1. + - IPMI IP: 10.30.51.88 + - Host IP: 10.30.50.88 + - portnames: + - s78-t215-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s78-t215-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s78-t215-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s78-t215-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s78-t215-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s78-t215-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s78-t215-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s78-t215-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s78-t215-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s78-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +``` + #### 3-Node-Skylake Servers (3n-skx) PROD ``` @@ -1237,8 +1495,6 @@ Note: Server19 (TG) is shared between testbed33 & testbed211 - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. - ServerB12 [Server-Type-B1]: - testbedname: testbed31. - hostname: s12-t31-sut2. @@ -1251,8 +1507,6 @@ Note: Server19 (TG) is shared between testbed33 & testbed211 - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE. - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. - ServerB13 [Server-Type-B2]: - testbedname: testbed31. - hostname: s13-t31-tg1. @@ -1265,8 +1519,6 @@ Note: Server19 (TG) is shared between testbed33 & testbed211 - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. - s13-t31-tg1-c10/p1 - 10GE-port1 x710-4p10GE. - s13-t31-tg1-c10/p2 - 10GE-port2 x710-4p10GE. - s13-t31-tg1-c10/p3 - 10GE-port3 x710-4p10GE. @@ -1283,8 +1535,6 @@ Note: Server19 (TG) is shared between testbed33 & testbed211 - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. - ServerB15 [Server-Type-B1]: - testbedname: testbed32. - hostname: s15-t32-sut2. @@ -1297,8 +1547,6 @@ Note: Server19 (TG) is shared between testbed33 & testbed211 - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE. - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. - ServerB16 [Server-Type-B2]: - testbedname: testbed32. - hostname: s16-t32-tg1. @@ -1311,8 +1559,6 @@ Note: Server19 (TG) is shared between testbed33 & testbed211 - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. - s16-t32-tg1-c10/p1 - 10GE-port1 x710-4p10GE. - s16-t32-tg1-c10/p2 - 10GE-port2 x710-4p10GE. - s16-t32-tg1-c10/p3 - 10GE-port3 x710-4p10GE. @@ -1400,6 +1646,8 @@ Note: Server19 (TG) is shared between testbed33 & testbed211 #### 3-Node-Altra Servers (3n-alt) TBD +Note: Server64 (TG) is shared between testbed34 & testbed36 + ``` - SUT [Server-Type-E23]: - testbedname: testbed34. @@ -1421,16 +1669,14 @@ Note: Server19 (TG) is shared between testbed33 & testbed211 - s63-t34-sut2-cn/p2 - 40GE-port2 xl710-QDA2-2p40GE. - s63-t34-sut2-ck/p1 - 100GE-port1 ConnectX5-2p100GE. - s63-t34-sut2-ck/p2 - 100GE-port1 ConnectX5-2p100GE. -- TG [TBD Server-Type]: +- TG [Server-Type-F4]: - testbedname: testbed34. - - hostname: s64-t34-tg1. + - hostname: s64-t34t36-tg1. - IPMI IP: 10.30.50.74 - Host IP: 10.30.51.74 - portnames: - - s64-t34-tg1-cn/p1 - 40GE-port1 xl710-QDA2-2p40GE. - - s64-t34-tg1-cn/p2 - 40GE-port2 xl710-QDA2-2p40GE. - - s64-t34-tg1-ck/p1 - 100GE-port1 ConnectX5-2p100GE. - - s64-t34-tg1-ck/p2 - 100GE-port1 ConnectX5-2p100GE. + - s64-t34-tg1-c1/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s64-t34-tg1-c1/p2 - 25GE-port2 xxv710-DA2-2p25GE. ``` #### 3-Node-Denverton Servers (3n-dnv) PROD @@ -1458,6 +1704,95 @@ Note: Server19 (TG) is shared between testbed33 & testbed211 - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port. ``` +#### 3-Node-Icelake Servers (3n-icx) TBD + +``` +- ServerF1 [Server-Type-F1]: + - testbedname: testbed37. + - hostname: s65-t37-sut1. + - IPMI IP: 10.30.50.75 + - Host IP: 10.30.51.75 + - portnames: + - s65-t37-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s65-t37-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s65-t37-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s65-t37-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s65-t37-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s65-t37-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s65-t37-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s65-t37-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- ServerF1 [Server-Type-F1]: + - testbedname: testbed37. + - hostname: s66-t37-sut2. + - IPMI IP: 10.30.50.76 + - Host IP: 10.30.51.76 + - portnames: + - s66-t37-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s66-t37-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s66-t37-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s66-t37-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s66-t37-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s66-t37-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s66-t37-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s66-t37-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- ServerF3 [Server-Type-F3]: + - testbedname: testbed37. + - hostname: s67-t37-tg1. + - IPMI IP: 10.30.50.77 + - Host IP: 10.30.51.77 + - portnames: + - s67-t37-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s67-t37-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s67-t37-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s67-t37-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s67-t37-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s67-t37-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s67-t37-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s67-t37-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- ServerF1 [Server-Type-F1]: + - testbedname: testbed38. + - hostname: s68-t38-sut1. + - IPMI IP: 10.30.50.78 + - Host IP: 10.30.51.78 + - portnames: + - s68-t38-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s68-t38-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s68-t38-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s68-t38-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s68-t38-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s68-t38-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s68-t38-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s68-t38-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- ServerF1 [Server-Type-F1]: + - testbedname: testbed38. + - hostname: s69-t38-sut2. + - IPMI IP: 10.30.50.79 + - Host IP: 10.30.51.79 + - portnames: + - s69-t38-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s69-t38-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s69-t38-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s69-t38-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s69-t38-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s69-t38-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s69-t38-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s69-t38-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- ServerF3 [Server-Type-F3]: + - testbedname: testbed38. + - hostname: s70-t38-tg1. + - IPMI IP: 10.30.50.80 + - Host IP: 10.30.51.80 + - portnames: + - s70-t38-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s70-t38-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s70-t38-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s70-t38-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s70-t38-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s70-t38-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s70-t38-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s70-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +``` + ### Per Testbed Wiring #### 1-Node-Skylake Wiring (1n-skx) PROD @@ -1678,6 +2013,71 @@ Note: Server19 (TG) is shared between testbed33 & testbed211 - s27-t211-sut1-c18/p2 - s19-t33t211-tg1-c8/p2. ``` +#### 2-Node-Icelake Wiring (2n-icx) TBD + +``` +- testbed212: + - ring1 25GE-ports xxv710-DA2-2p25GE on SUT + - s72-t212-tg1-c2/p1 to s71-t212-sut1-c2/p1. + - s71-t212-sut1-c2/p2 to s72-t212-tg1-c2/p2. + - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT: + - s72-t212-tg1-c4/p1 to s71-t212-sut1-c4/p1. + - s71-t212-sut1-c4/p2 to s72-t212-tg1-c4/p2. + - s72-t212-tg1-c4/p3 to s71-t212-sut1-c4/p3. + - s71-t212-sut1-c4/p4 to s72-t212-tg1-c4/p4. + - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT: + - s72-t212-tg1-c9/p1 to s71-t212-sut1-c9/p1. + - s71-t212-sut1-c9/p2 to s72-t212-tg1-c9/p2. + - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT: + - s72-t212-tg1-c6/p1 to s72-t212-tg1-c6/p2. + - s72-t212-tg1-c6/p2 to s72-t212-tg1-c6/p1. +- testbed213: + - ring1 25GE-ports xxv710-DA2-2p25GE on SUT + - s74-t213-tg1-c2/p1 to s73-t213-sut1-c2/p1. + - s73-t213-sut1-c2/p2 to s74-t213-tg1-c2/p2. + - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT: + - s74-t213-tg1-c4/p1 to s73-t213-sut1-c4/p1. + - s73-t213-sut1-c4/p2 to s74-t213-tg1-c4/p2. + - s74-t213-tg1-c4/p3 to s73-t213-sut1-c4/p3. + - s73-t213-sut1-c4/p4 to s74-t213-tg1-c4/p4. + - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT: + - s74-t213-tg1-c9/p1 to s73-t213-sut1-c9/p1. + - s73-t213-sut1-c9/p2 to s74-t213-tg1-c9/p2. + - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT: + - s74-t213-tg1-c6/p1 to s74-t213-tg1-c6/p2. + - s74-t213-tg1-c6/p2 to s74-t213-tg1-c6/p1. +- testbed214: + - ring1 25GE-ports xxv710-DA2-2p25GE on SUT + - s76-t214-tg1-c2/p1 to s75-t214-sut1-c2/p1. + - s75-t214-sut1-c2/p2 to s76-t214-tg1-c2/p2. + - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT: + - s76-t214-tg1-c4/p1 to s75-t214-sut1-c4/p1. + - s75-t214-sut1-c4/p2 to s76-t214-tg1-c4/p2. + - s76-t214-tg1-c4/p3 to s75-t214-sut1-c4/p3. + - s75-t214-sut1-c4/p4 to s76-t214-tg1-c4/p4. + - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT: + - s76-t214-tg1-c9/p1 to s75-t214-sut1-c9/p1. + - s75-t214-sut1-c9/p2 to s76-t214-tg1-c9/p2. + - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT: + - s76-t214-tg1-c6/p1 to s76-t214-tg1-c6/p2. + - s76-t214-tg1-c6/p2 to s76-t214-tg1-c6/p1. +- testbed215: + - ring1 25GE-ports xxv710-DA2-2p25GE on SUT + - s78-t215-tg1-c2/p1 to s77-t215-sut1-c2/p1. + - s77-t215-sut1-c2/p2 to s78-t215-tg1-c2/p2. + - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT: + - s78-t215-tg1-c4/p1 to s77-t215-sut1-c4/p1. + - s77-t215-sut1-c4/p2 to s78-t215-tg1-c4/p2. + - s78-t215-tg1-c4/p3 to s77-t215-sut1-c4/p3. + - s77-t215-sut1-c4/p4 to s78-t215-tg1-c4/p4. + - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT: + - s78-t215-tg1-c9/p1 to s77-t215-sut1-c9/p1. + - s77-t215-sut1-c9/p2 to s78-t215-tg1-c9/p2. + - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT: + - s78-t215-tg1-c6/p1 to s78-t215-tg1-c6/p2. + - s78-t215-tg1-c6/p2 to s78-t215-tg1-c6/p1. +``` + #### 3-Node-Skylake Wiring (3n-skx) PROD ``` @@ -1771,6 +2171,43 @@ To be completed. - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4. ``` +#### 3-Node-Icelake Wiring (3n-icx) TBD + +``` +- testbed37: + - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs: + - s67-t37-tg1-c2/p1 to s65-t37-sut1-c2/p1. + - s65-t37-sut1-c2/p2 to s66-t37-sut2-c2/p2. + - s66-t37-sut2-c2/p1 to s67-t37-tg1-c2/p2. + - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT: + - s67-t37-tg1-c4/p1 to s65-t37-sut1-c4/p1. + - s65-t37-sut1-c4/p2 to s66-t37-sut2-c4/p2. + - s66-t37-sut2-c4/p1 to s67-t37-tg1-c4/p2. + - s67-t37-tg1-c4/p3 to s65-t37-sut1-c4/p3. + - s65-t37-sut1-c4/p4 to s66-t37-sut2-c4/p4. + - s66-t37-sut2-c4/p3 to s67-t37-tg1-c4/p4. + - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT + - s67-t37-tg1-c9/p1 to s65-t37-sut1-c9/p1. + - s65-t37-sut1-c9/p2 to s66-t37-sut2-c9/p2. + - s66-t37-sut2-c9/p1 to s67-t37-tg1-c9/p2. +- testbed38: + - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs: + - s70-t38-tg1-c2/p1 to s68-t38-sut1-c2/p1. + - s68-t38-sut1-c2/p2 to s69-t38-sut2-c2/p2. + - s69-t38-sut2-c2/p1 to s70-t38-tg1-c2/p2. + - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT: + - s70-t38-tg1-c4/p1 to s68-t38-sut1-c4/p1. + - s68-t38-sut1-c4/p2 to s69-t38-sut2-c4/p2. + - s69-t38-sut2-c4/p1 to s70-t38-tg1-c4/p2. + - s70-t38-tg1-c4/p3 to s68-t38-sut1-c4/p3. + - s68-t38-sut1-c4/p4 to s69-t38-sut2-c4/p4. + - s69-t38-sut2-c4/p3 to s70-t38-tg1-c4/p4. + - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT + - s70-t38-tg1-c9/p1 to s68-t38-sut1-c9/p1. + - s68-t38-sut1-c9/p2 to s69-t38-sut2-c9/p2. + - s69-t38-sut2-c9/p1 to s70-t38-tg1-c9/p2. +``` + ## Inventory ### Appliances |