diff options
Diffstat (limited to 'docs')
-rw-r--r-- | docs/lab/fdio-dc-inventory-vexxhost.md | 8 | ||||
-rw-r--r-- | docs/lab/fdio-dc-physical.yaml | 6 | ||||
-rw-r--r-- | docs/lab/testbed_specifications.md | 371 | ||||
-rw-r--r-- | docs/report/introduction/test_environment_sut_calib_tx2.rst | 2 |
4 files changed, 192 insertions, 195 deletions
diff --git a/docs/lab/fdio-dc-inventory-vexxhost.md b/docs/lab/fdio-dc-inventory-vexxhost.md index 7b2e524a17..84c20ad2d2 100644 --- a/docs/lab/fdio-dc-inventory-vexxhost.md +++ b/docs/lab/fdio-dc-inventory-vexxhost.md @@ -46,8 +46,8 @@ s14-t32-sut1,up,t31,3n-skx,SYS-7049GP-TRT,C7470KH06A20075,10.30.51.58,10.30.50.5 s15-t32-sut2,up,t31,3n-skx,SYS-7049GP-TRT,C7470KH06A20010,10.30.51.59,10.30.50.56,3016.9,u26-u29 s16-t32-tg1,up,t31,3n-skx,SYS-7049GP-TRT,C7470KH06A20047,10.30.51.60,10.30.50.57,3016.9,u22-u25 s25-t25-sut1,down,t25,2n-p1,SYS-7049GP-TRT,C7470KH06A20022,10.30.51.61,10.30.50.58,3016.9,u18-u21 -s19-t33t34-tg1,up,t33t34,3n-tsh/2n-tx2,SYS-7049GP-TRT,C7470KH06A20056,10.30.51.49,10.30.50.46,3016.9,u14-u17 -s27-t211-sut1,up,t25,2n-tx2,ThunderX2-9975,K61186073100003,10.30.51.69,10.30.50.69,3016.9,u13 +s19-t33t211-tg1,up,t33t211,3n-tsh/2n-tx2,SYS-7049GP-TRT,C7470KH06A20056,10.30.51.49,10.30.50.46,3016.9,u14-u17 +s27-t211-sut1,up,t211,2n-tx2,ThunderX2-9975,K61186073100003,10.30.51.69,10.30.50.69,3016.9,u13 s18-t33-sut2,up,t33,3n-tsh,HUAWEI-TAISHAN-2280,N/A,10.30.51.37,10.30.50.37,3016.9,u11-u12 s17-t33-sut1,up,t33,3n-tsh,HUAWEI-TAISHAN-2280,N/A,10.30.51.36,10.30.50.36,3016.9,u9-u10 @@ -75,7 +75,7 @@ mtl1-6-7050QX-32,up,switch,uplink,?,?,?,?,3016.11,u46 fdio-marvell-dev,up,N/A,dev,ThunderX-88XX,N/A,10.30.51.38,10.30.50.38,3016.11,u45 s53-nomad,up,nomad-cluster1,nomad-client,ThunderX-88XX,N/A,10.30.51.39,10.30.50.39,3016.11,u44 s54-nomad,up,nomad-cluster1,nomad-client,ThunderX-88XX,N/A,10.30.51.40,10.30.50.40,3016.11,u43 -s56-t37-sut1,up,t37,2n-tx2,ThunderX2-9980,N/A,10.30.51.71,10.30.50.71,3016.11,u41-u42 +s56-t14-sut1,up,t14,1n-tx2,ThunderX2-9980,N/A,10.30.51.71,10.30.50.71,3016.11,u41-u42 s41-nomad,up,nomad-cluster1,nomad-client,UCSC-C240-M4SX,FCH1950V1FQ,10.30.51.28,10.30.50.28,3016.11,u39-u40 s40-nomad,up,nomad-cluster1,nomad-client,UCSC-C240-M4SX,FCH2013V0HZ,10.30.51.30,10.30.50.30,3016.11,u37-u38 s39-nomad,up,nomad-cluster1,nomad-client,UCSC-C240-M4SX,FCH2013V0J2,10.30.51.29,10.30.50.29,3016.11,u35-u36 @@ -83,7 +83,7 @@ s42-nomad,up,nomad-cluster1,nomad-client,UCSC-C240-M4SX,FCH1950V1FN,10.30.51.22, s43-nomad,up,nomad-cluster1,nomad-client,UCSC-C240-M4SX,FCH1950V1H5,10.30.51.24,10.30.50.24,3016.11,u17-u18 s44-nomad,up,nomad-cluster1,nomad-client,UCSC-C240-M4SX,FCH1950V1FS,10.30.51.25,10.30.50.25,3016.11,u15-u16 s45-nomad,up,nomad-cluster1,nomad-client,UCSC-C240-M4SX,FCH1950V1FL,10.30.51.26,10.30.50.26,3016.11,u13-u14 -s55-t36-sut1,up,t36,1n-tx2,ThunderX2-9980,N/A,10.30.51.70,10.30.50.70,3016.11,u11-u12 +s55-t13-sut1,up,t13,1n-tx2,ThunderX2-9980,N/A,10.30.51.70,10.30.50.70,3016.11,u11-u12 s52-nomad,up,nomad-cluster1,nomad-client,ThunderX-88XX,N/A,10.30.51.65,10.30.50.65,3016.11,u9-u10 s51-nomad,up,nomad-cluster1,nomad-client,ThunderX-88XX,N/A,10.30.51.66,10.30.50.66,3016.11,u9-u10 s49-nomad,up,nomad-cluster1,nomad-client,ThunderX-88XX,N/A,10.30.51.67,10.30.50.67,3016.11,u9-u10 diff --git a/docs/lab/fdio-dc-physical.yaml b/docs/lab/fdio-dc-physical.yaml index ca8978e552..23a5d145d2 100644 --- a/docs/lab/fdio-dc-physical.yaml +++ b/docs/lab/fdio-dc-physical.yaml @@ -69,7 +69,7 @@ yul1: mgmt_ip4: 10.30.51.61 lom_ip4: 10.30.50.58 - unit: 14..17 - name: s19-t33t34-tg1 + name: s19-t33t211-tg1 oper_status: production device_type: SYS-7049GP-TRT serial_number: C7470KH06A20056 @@ -235,7 +235,7 @@ yul1: mgmt_ip4: 10.30.51.40 lom_ip4: 10.30.50.40 - unit: 41..42 - name: s56-t37-sut1 + name: s56-t14-sut1 oper_status: production device_type: ThunderX2-9980 serial_number: N/A @@ -291,7 +291,7 @@ yul1: mgmt_ip4: 10.30.51.26 lom_ip4: 10.30.50.26 - unit: 11..12 - name: s55-t36-sut1 + name: s55-t13-sut1 oper_status: production device_type: ThunderX2-9980 serial_number: N/A diff --git a/docs/lab/testbed_specifications.md b/docs/lab/testbed_specifications.md index b728370064..b905aa798a 100644 --- a/docs/lab/testbed_specifications.md +++ b/docs/lab/testbed_specifications.md @@ -13,8 +13,8 @@ 1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn) 1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2) 1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx) - 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh) 1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds) + 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh) 1. [Server Management](#server-management) 1. [Requirements](#requirements) 1. [Addressing](#addressing) @@ -71,13 +71,13 @@ hosted by LFN FD.io CSIT project. #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #clx #zn2 1. 1-Node-Haswell nomad hsw na 4 4 0 4 0 0 0 0 0 0 0 0 2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0 0 - 3. 1-Node-ThunderX2 perf tx2 na 1 1 .5 0 .5 0 0 0 1 0 0 0 - 4. 1-Node-ThunderX2 dev tx2 na 2 2 0 0 0 0 0 0 2 0 0 0 - 5. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 1 0 - 6. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0 0 - 7. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0 0 - 8. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0 0 - 9. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 6 0 + 3. 1-Node-ThunderX2 dev tx2 na 2 2 0 0 0 0 0 0 2 0 0 0 + 4. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 1 0 + 5. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0 0 + 6. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0 0 + 7. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0 0 + 8. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 6 0 + 9. 2-Node-ThunderX2 perf tx2 skx 1 1 .5 0 .5 0 0 0 1 0 0 0 10. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 0 11. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 0 12. 3-Node-Taishan perf tsh skx 1 2 .5 0 .5 0 0 0 0 2 0 0 @@ -94,7 +94,7 @@ Used for FD.io VPP_Device functional driver tests. ### 1-Node-ThunderX2 Arm Marvell (1n-tx2) -Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-B11) with NIC +Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-E11) with NIC ports connected back-to-back ([Server Types](#server-types)). Used for FD.io VPP_Device functional driver tests. @@ -142,8 +142,8 @@ Used for FD.io performance tests. ### 2-Node-ThunderX2 Arm Marvell (2x-tx2) -Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-B9) and -one TG (Server-Type-B12) connected in a 2-node circular topology +Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-E22) and +one TG (Server-Type-E31) connected in a 2-node circular topology ([Server Types](#server-types)). Used for FD.io performance tests. @@ -160,17 +160,17 @@ Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one TG (Server-Type-B2) connected in a 3-node circular topology. Used for FD.io performance tests. -### 3-Node-TaiShan Arm Huawei (3n-tsh) +### 3-Node-Rangeley Atom Testbeds -Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-B3) and one -TG (Server-Type-B12) connected in a 3-node circular topology +Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one +TG (Server-Type-2) connected in a 3-node circular topology ([Server Types](#server-types)). Used for FD.io performance tests. -### 3-Node-Rangeley Atom Testbeds +### 3-Node-TaiShan Arm Huawei (3n-tsh) -Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one -TG (Server-Type-2) connected in a 3-node circular topology +Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-E21) and one +TG (Server-Type-E31) connected in a 3-node circular topology ([Server Types](#server-types)). Used for FD.io performance tests. @@ -252,7 +252,7 @@ Name | Comment 10.30.50.43 | s11-t31-sut1 10.30.50.44 | s12-t31-sut2 10.30.50.45 | s13-t31-tg1 -10.30.50.46 | s19-t33t34-tg1 +10.30.50.46 | s19-t33t211-tg1 10.30.50.47 | s1-t11-sut1 10.30.50.48 | s2-t12-sut1 10.30.50.49 | s5-t22-sut1 @@ -270,12 +270,10 @@ Name | Comment 10.30.50.66 | s51-nomad 10.30.50.67 | s49-nomad 10.30.50.68 | s50-nomad -10.30.50.69 | s27-t34-sut1 -10.30.50.70 | s55-t36-sut1 -10.30.50.71 | s56-t37-sut1 +10.30.50.69 | s27-t211-sut1 +10.30.50.70 | s55-t13-sut1 +10.30.50.71 | s56-t14-sut1 10.30.50.255 | Broadcast -n/a | s20-t34-sut1 -n/a | s21-t34-sut2 10.30.55.0 | network 10.30.55.1 | Router 10.30.55.10 | s28-t26t35-tg1 @@ -327,7 +325,7 @@ Name | Comment 10.30.51.46 | s11-t31-sut1 10.30.51.47 | s12-t31-sut2 10.30.51.48 | s13-t31-tg1 -10.30.51.49 | s19-t33t34-tg1 +10.30.51.49 | s19-t33t211-tg1 10.30.51.50 | s1-t11-sut1 10.30.51.51 | s2-t12-sut1 10.30.51.52 | s5-t22-sut1 @@ -345,9 +343,9 @@ Name | Comment 10.30.51.66 | s51-nomad 10.30.51.67 | s49-nomad 10.30.51.68 | s50-nomad -10.30.51.69 | s27-t34-sut1 -10.30.51.70 | s55-t36-sut1 -10.30.51.71 | s56-t37-sut1 +10.30.51.69 | s27-t211-sut1 +10.30.51.70 | s55-t13-sut1 +10.30.51.71 | s56-t14-sut1 10.30.51.72-10.30.51.254 | FREE 10.30.51.255 | Broadcast 10.32.8.0 | network @@ -472,20 +470,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: x710-4p10GE Intel. -6. Server-Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing. - - Quantity: 2 - - Physical connectivity: - - IPMI(?) and host management ports. - - NIC ports connected into 3-node topology. - - Main HW configuration: - - Chassis: Huawei TaiShan 2280. - - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72 - - RAM Memory: 8* 16GB DDR4-2400MT/s - - Disks: 1* 4TB SATA HDD - - NICs configuration: - - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox. - - PCIe Slot6 11:00.xx: x520-2p10GE Intel. -7. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing. +6. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing. - Quantity: TBD based on testbed allocation. - Physical connectivity: - Management: serial Port (usb) for console @@ -498,7 +483,7 @@ FD.io CSIT lab contains following server types: - NICs configuration: - 2x 10Gb Intel 82599ES - 4x 1GB Intel I354 -8. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests. +7. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests. - Quantity: 2. - Physical connectivity: - IPMI and host management ports. @@ -518,7 +503,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -9. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests. +8. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests. - Quantity: 1. - Physical connectivity: - Host management interface: 10/100/1000-BaseT. @@ -537,7 +522,7 @@ FD.io CSIT lab contains following server types: - Port-2: 10GE SFP+. - Port-3: 10GE SFP+. - Port-4: 10GE SFP+. -10. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests. +9. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -557,23 +542,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -11. Server-Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing. - - Quantity: 1 - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 1-node topologies. - - Main HW configuration: - - Chassis: Gigabyte R181-T90 1U - - Motherboard: MT91-FS1 - - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz - - RAM Memory: 4* 32GB RDIMM - - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25 - - NICs configuration: - - Numa0: - - PCIe Slot6 08:00.xx: XL710-QDA2-2p40GE Intel. - - Numa1: - - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel. -12. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing. +10. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing. - Quantity: 4 - Physical connectivity: - IPMI and host management ports. @@ -587,46 +556,7 @@ FD.io CSIT lab contains following server types: - 2x 10Gb Intel x553 fiber ports - 2x 10Gb Intel x553 copper ports - 4x 1GB Intel I350 ports -13. Server-Type-B11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests. - - Quantity: 2 - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 1-node topologies. - - Main HW configuration: - - Chassis: GIGABYTE Rack Mount - - Motherboard: MT91-FS4-00 - - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz - - RAM Memory: 16 * 16GB DIMM - - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480 - - NICs configuration: - - Numa0: - - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel. - - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox. - - Numa1: - - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel. - - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox. -14. Server-Type-B12: Purpose - Skylake Xeon TG for FD.io performance testing. - - Quantity: --- - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 2-node and 3-node topologies. - - Main HW configuration: - - Chassis: SuperMicro SYS-7049GP-TRT. - - Motherboard: SuperMicro X11DPG-QT. - - Processors: 2* Intel Platinum 8180 2.5 GHz. - - RAM Memory: 16* 16GB DDR4-2666MHz. - - Disks: 2* 1.6TB 6G SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot2 18:00.xx: x710-4p10GE Intel. - - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel. - - PCIe Slot9 5e:00.xx: empty. - - Numa1: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot6 86:00.xx: empty. - - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel. - - PCIe Slot10 d8:00.xx: x710-4p10GE Intel. - -15. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests. +11. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -646,7 +576,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -16. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing. +12. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing. - Quantity: 3 - Physical connectivity: - IPMI and host management ports. @@ -666,7 +596,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -17. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing. +13. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing. - Quantity: 3. - Physical connectivity: - IPMI and host management ports. @@ -686,7 +616,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -18. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing. +14. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing. - Quantity: 3. - Physical connectivity: - CIMC and host management ports. @@ -702,7 +632,7 @@ FD.io CSIT lab contains following server types: - no cards. - Numa1: - no cards. -19. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing. +15. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -717,7 +647,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot1 01:00.xx: x710-4p10GE Intel. - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel. - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox. -20. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing. +16. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -732,6 +662,73 @@ FD.io CSIT lab contains following server types: - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox. - PCIe Slot2 41:00.xx: x710-4p10GE Intel. - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel. +17. Server-Type-E11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests. + - Quantity: 2 + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 1-node topologies. + - Main HW configuration: + - Chassis: GIGABYTE Rack Mount + - Motherboard: MT91-FS4-00 + - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz + - RAM Memory: 16 * 16GB DIMM + - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480 + - NICs configuration: + - Numa0: + - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel. + - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox. + - Numa1: + - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel. + - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox. +18. Server-Type-E21: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing. + - Quantity: 2 + - Physical connectivity: + - IPMI(?) and host management ports. + - NIC ports connected into 3-node topology. + - Main HW configuration: + - Chassis: Huawei TaiShan 2280. + - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72 + - RAM Memory: 8* 16GB DDR4-2400MT/s + - Disks: 1* 4TB SATA HDD + - NICs configuration: + - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox. + - PCIe Slot6 11:00.xx: x520-2p10GE Intel. +19. Server-Type-E22: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing. + - Quantity: 1 + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node topologies. + - Main HW configuration: + - Chassis: Gigabyte R181-T90 1U + - Motherboard: MT91-FS1 + - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz + - RAM Memory: 4* 32GB RDIMM + - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25 + - NICs configuration: + - Numa0: + - PCIe Slot6 08:00.xx: XL710-QDA2-2p40GE Intel. + - Numa1: + - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel. +20. Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing. + - Quantity: 1 + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node and 3-node topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-7049GP-TRT. + - Motherboard: SuperMicro X11DPG-QT. + - Processors: 2* Intel Platinum 8180 2.5 GHz. + - RAM Memory: 16* 16GB DDR4-2666MHz. + - Disks: 2* 1.6TB 6G SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: x710-4p10GE Intel. + - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel. + - PCIe Slot9 5e:00.xx: empty. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: empty. + - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel. + - PCIe Slot10 d8:00.xx: x710-4p10GE Intel. ``` ### Naming Convention @@ -795,34 +792,34 @@ connectivity and wiring across defined CSIT testbeds: #### 1-Node-ThunderX2 Servers (1n-tx2) PROD ``` -- SUT [Server-Type-B11]: - - testbedname: testbed36 - - hostname: s55-t36-sut1 +- SUT [Server-Type-E11]: + - testbedname: testbed13 + - hostname: s55-t13-sut1 - IPMI IP: 10.30.50.70 - Host IP: 10.30.51.70 - portnames: - - s55-t36-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE. - - s55-t36-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE. - - s55-t36-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. - - s55-t36-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. - - s55-t36-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE. - - s55-t36-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE. - - s55-t36-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. - - s55-t36-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. -- SUT [Server-Type-B11]: - - testbedname: testbed37 - - hostname: s56-t37-sut1 + - s55-t13-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE. + - s55-t13-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE. + - s55-t13-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. + - s55-t13-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. + - s55-t13-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE. + - s55-t13-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE. + - s55-t13-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. + - s55-t13-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. +- SUT [Server-Type-E11]: + - testbedname: testbed14 + - hostname: s56-t14-sut1 - IPMI IP: 10.30.50.71 - Host IP: 10.30.51.71 - portnames: - - s56-t37-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE. - - s56-t37-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE. - - s56-t37-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. - - s56-t37-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. - - s56-t37-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE. - - s56-t37-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE. - - s56-t37-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. - - s56-t37-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. + - s56-t14-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE. + - s56-t14-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE. + - s56-t14-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. + - s56-t14-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. + - s56-t14-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE. + - s56-t14-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE. + - s56-t14-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. + - s56-t14-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. ``` #### 1-Node-Cascadelake Servers (1n-clx) PROD @@ -1141,37 +1138,37 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 #### 2-Node-ThunderX2 Servers (2x-tx2) PROD -Note: Server19 (TG) is shared between testbed33 & testbed34 +Note: Server19 (TG) is shared between testbed33 & testbed211 ``` -- SUT [Server-Type-B9]: - - testbedname: testbed34. - - hostname: s27-t34-sut1. +- SUT [Server-Type-E22]: + - testbedname: testbed211. + - hostname: s27-t211-sut1. - IPMI IP: 10.30.50.69 - Host IP: 10.30.51.69 - portnames: - - s27-t34-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE. - - s27-t34-sut1-c6/p2 - 40GE-port1 XL710-QDA2-2p40GE. - - s27-t34-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE. - - s27-t34-sut1-c18/p2 - 40GE-port1 XL710-QDA2-2p40GE. -- TG [Server-Type-B12]: - - testbedname: testbed33 and testbed34. - - hostname: s19-t33t34-tg1. + - s27-t211-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE. + - s27-t211-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE. + - s27-t211-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE. + - s27-t211-sut1-c18/p2 - 40GE-port2 XL710-QDA2-2p40GE. +- TG [Server-Type-E31]: + - testbedname: testbed33 and testbed211. + - hostname: s19-t33t211-tg1. - IPMI IP: 10.30.50.46 - Host IP: 10.30.51.49 - portnames: - - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE. - - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE. - - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE. - - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s19-t33t34-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE. - - s19-t33t34-tg1-c8/p2 - 40GE-port1 xl710-QDA2-2p40GE. - - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE. - - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE. - - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE. - - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE. + - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE. + - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE. + - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE. + - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE. + - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE. + - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE. ``` #### 3-Node-Skylake Servers (3n-skx) PROD @@ -1299,10 +1296,10 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. #### 3-Node-Taishan Servers (3n-tsh) PROD -Note: Server19 (TG) is shared between testbed33 & testbed34 +Note: Server19 (TG) is shared between testbed33 & testbed211 ``` -- SUT [Server-Type-B3]: +- SUT [Server-Type-E21]: - testbedname: testbed33. - hostname: s17-t33-sut1. - IPMI IP: 10.30.50.36 @@ -1312,7 +1309,7 @@ Note: Server19 (TG) is shared between testbed33 & testbed34 - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE. - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE. - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE. -- SUT [Server-Type-B3]: +- SUT [Server-Type-E21]: - testbedname: testbed33. - hostname: s18-t33-sut2. - IPMI IP: 10.30.50.37 @@ -1322,24 +1319,24 @@ Note: Server19 (TG) is shared between testbed33 & testbed34 - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE. - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE. - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE. -- TG [Server-Type-B12]: - - testbedname: testbed33 and testbed34. - - hostname: s19-t33t34-tg1. +- TG [Server-Type-E31]: + - testbedname: testbed33 and testbed211. + - hostname: s19-t33t211-tg1. - IPMI IP: 10.30.50.46 - Host IP: 10.30.51.49 - portnames: - - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE. - - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE. - - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE. - - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s19-t33t34-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE. - - s19-t33t34-tg1-c8/p2 - 40GE-port1 xl710-QDA2-2p40GE. - - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE. - - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE. - - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE. - - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE. + - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE. + - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE. + - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE. + - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE. + - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE. + - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE. ``` #### 3-Node-Denverton Servers (3n-dnv) PROD @@ -1403,25 +1400,25 @@ Note: Server19 (TG) is shared between testbed33 & testbed34 #### 1-Node-ThunderX2 Wiring (1n-tx2) PROD ``` -- testbed36: +- testbed13: - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs: - - s55-t36-sut1-c4/p1 - s55-t36-sut1-c14/p1. + - s55-t13-sut1-c4/p1 - s55-t13-sut1-c14/p1. - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs: - - s55-t36-sut1-c4/p2 - s55-t36-sut1-c14/p2. + - s55-t13-sut1-c4/p2 - s55-t13-sut1-c14/p2. - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs: - - s55-t36-sut1-c8/p1 - s55-t36-sut1-c26/p1. + - s55-t13-sut1-c8/p1 - s55-t13-sut1-c26/p1. - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs: - - s55-t36-sut1-c8/p2 - s55-t36-sut1-c26/p2. + - s55-t13-sut1-c8/p2 - s55-t13-sut1-c26/p2. -- testbed37: +- testbed14: - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs: - - s56-t37-sut1-c4/p1 - s56-t37-sut1-c14/p1. + - s56-t14-sut1-c4/p1 - s56-t14-sut1-c14/p1. - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs: - - s56-t37-sut1-c4/p2 - s56-t37-sut1-c14/p2. + - s56-t14-sut1-c4/p2 - s56-t14-sut1-c14/p2. - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs: - - s55-t37-sut1-c8/p1 - s55-t37-sut1-c26/p1. + - s56-t14-sut1-c8/p1 - s56-t14-sut1-c26/p1. - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs: - - s55-t37-sut1-c8/p2 - s55-t37-sut1-c26/p2. + - s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2. ``` #### 1-Node-Cascadelake Wiring (1n-clx) PROD @@ -1583,10 +1580,10 @@ Note: Server19 (TG) is shared between testbed33 & testbed34 #### 2-Node-ThunderX2 Wiring (2n-tx2) PROD ``` -- testbed34: +- testbed211: - ring1 10GE-ports x520-2p10GE on SUTs: - - s27-t34-sut1-c18/p1 - s19-t33t34-tg1-c8/p1. - - s27-t34-sut1-c18/p2 - s19-t33t34-tg1-c8/p2. + - s27-t211-sut1-c18/p1 - s19-t33t211-tg1-c8/p1. + - s27-t211-sut1-c18/p2 - s19-t33t211-tg1-c8/p2. ``` #### 3-Node-Skylake Wiring (3n-skx) PROD @@ -1645,13 +1642,13 @@ To be completed. ``` - testbed33: - ring1 10GE-ports x520-2p10GE on SUTs: - - s19-t33t34-tg1-c2/p2 - s17-t33-sut1-c6/p2. + - s19-t33t211-tg1-c2/p2 - s17-t33-sut1-c6/p2. - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2. - - s18-t33-sut2-c6/p1 - s19-t33t34-tg1-c2/p1. + - s18-t33-sut2-c6/p1 - s19-t33t211-tg1-c2/p1. - ring2 25GE-ports cx4-2p25GE on SUTs: - - s19-t33t34-tg1-c4/p2 - s17-t33-sut1-c4/p2. + - s19-t33t211-tg1-c4/p2 - s17-t33-sut1-c4/p2. - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2. - - s18-t33-sut2-c4/p1 - s19-t33t34-tg1-c4/p1. + - s18-t33-sut2-c4/p1 - s19-t33t211-tg1-c4/p1. ``` #### 3-Node-Denverton Wiring (3n-dnv) PROD @@ -1685,7 +1682,7 @@ To be completed. - Operating System: Native IxOS. ``` -### Arm Servers +### Arm Servers ``` 1. Arm Cortex A-72 servers diff --git a/docs/report/introduction/test_environment_sut_calib_tx2.rst b/docs/report/introduction/test_environment_sut_calib_tx2.rst index 2844ec169a..05b7d8c16a 100644 --- a/docs/report/introduction/test_environment_sut_calib_tx2.rst +++ b/docs/report/introduction/test_environment_sut_calib_tx2.rst @@ -2,7 +2,7 @@ ThunderX2 ~~~~~~~~~ Following sections include sample calibration data measured on -s27-t34-sut1 server running in one of the ThunderX2 testbeds. +s27-t211-sut1 server running in one of the ThunderX2 testbeds. Linux cmdline |