aboutsummaryrefslogtreecommitdiffstats
path: root/resources
diff options
context:
space:
mode:
Diffstat (limited to 'resources')
-rw-r--r--resources/tools/presentation/specification.yaml136
1 files changed, 68 insertions, 68 deletions
diff --git a/resources/tools/presentation/specification.yaml b/resources/tools/presentation/specification.yaml
index ee5951f23c..8e1b5a45fb 100644
--- a/resources/tools/presentation/specification.yaml
+++ b/resources/tools/presentation/specification.yaml
@@ -2725,74 +2725,74 @@
- "x710, xxv710 - NICs tested."
- "Diff - difference between x710 and xxv710 NIC."
-# VPP Compare NICs 3n-skx 2t1c mrr
-- type: "table"
- title: "VPP Compare NICs 3n-skx 2t1c mrr"
- algorithm: "table_comparison"
- output-file: "{DIR[STATIC,VPP]}/performance-changes-3n-skx-2t1c-nics-mrr"
- include-tests: "MRR" # "PDR" | "NDR" | "MRR"
- filter: "'2T1C' and 'MRR' and not 'NF_DENSITY'"
- columns:
- - title: "x710"
- data-set: "vpp-nic-comparison-3n-skx-mrr"
- tag: "NIC_Intel-X710"
- - title: "xxv710"
- data-set: "vpp-nic-comparison-3n-skx-mrr"
- tag: "NIC_Intel-XXV710"
- comparisons:
- - title: "Diff"
- reference: 1
- compare: 2
- legend:
- - "Legend to Table:"
- - "x710, xxv710 - NICs tested."
- - "Diff - difference between x710 and xxv710 NIC."
-
-# VPP Compare NICs 3n-skx 4t2c mrr
-- type: "table"
- title: "VPP Compare NICs 3n-skx 4t2c mrr"
- algorithm: "table_comparison"
- output-file: "{DIR[STATIC,VPP]}/performance-changes-3n-skx-4t2c-nics-mrr"
- include-tests: "MRR" # "PDR" | "NDR" | "MRR"
- filter: "'4T2C' and 'MRR' and not 'NF_DENSITY'"
- columns:
- - title: "x710"
- data-set: "vpp-nic-comparison-3n-skx-mrr"
- tag: "NIC_Intel-X710"
- - title: "xxv710"
- data-set: "vpp-nic-comparison-3n-skx-mrr"
- tag: "NIC_Intel-XXV710"
- comparisons:
- - title: "Diff"
- reference: 1
- compare: 2
- legend:
- - "Legend to Table:"
- - "x710, xxv710 - NICs tested."
- - "Diff - difference between x710 and xxv710 NIC."
-
-# VPP Compare NICs 3n-skx 8t4c mrr
-- type: "table"
- title: "VPP Compare NICs 3n-skx 8t4c mrr"
- algorithm: "table_comparison"
- output-file: "{DIR[STATIC,VPP]}/performance-changes-3n-skx-8t4c-nics-mrr"
- include-tests: "MRR" # "PDR" | "NDR" | "MRR"
- filter: "'8T4C' and 'MRR' and not 'NF_DENSITY'"
- columns:
- - title: "x710"
- data-set: "vpp-nic-comparison-3n-skx-mrr"
- tag: "NIC_Intel-X710"
- - title: "xxv710"
- data-set: "vpp-nic-comparison-3n-skx-mrr"
- tag: "NIC_Intel-XXV710"
- comparisons:
- - title: "Diff"
- reference: 1
- compare: 2
- legend:
- - "Legend to Table:"
- - "x710, xxv710 - NICs tested."
- - "Diff - difference between x710 and xxv710 NIC."
+## VPP Compare NICs 3n-skx 2t1c mrr
+#- type: "table"
+# title: "VPP Compare NICs 3n-skx 2t1c mrr"
+# algorithm: "table_comparison"
+# output-file: "{DIR[STATIC,VPP]}/performance-changes-3n-skx-2t1c-nics-mrr"
+# include-tests: "MRR" # "PDR" | "NDR" | "MRR"
+# filter: "'2T1C' and 'MRR' and not 'NF_DENSITY'"
+# columns:
+# - title: "x710"
+# data-set: "vpp-nic-comparison-3n-skx-mrr"
+# tag: "NIC_Intel-X710"
+# - title: "xxv710"
+# data-set: "vpp-nic-comparison-3n-skx-mrr"
+# tag: "NIC_Intel-XXV710"
+# comparisons:
+# - title: "Diff"
+# reference: 1
+# compare: 2
+# legend:
+# - "Legend to Table:"
+# - "x710, xxv710 - NICs tested."
+# - "Diff - difference between x710 and xxv710 NIC."
+#
+## VPP Compare NICs 3n-skx 4t2c mrr
+#- type: "table"
+# title: "VPP Compare NICs 3n-skx 4t2c mrr"
+# algorithm: "table_comparison"
+# output-file: "{DIR[STATIC,VPP]}/performance-changes-3n-skx-4t2c-nics-mrr"
+# include-tests: "MRR" # "PDR" | "NDR" | "MRR"
+# filter: "'4T2C' and 'MRR' and not 'NF_DENSITY'"
+# columns:
+# - title: "x710"
+# data-set: "vpp-nic-comparison-3n-skx-mrr"
+# tag: "NIC_Intel-X710"
+# - title: "xxv710"
+# data-set: "vpp-nic-comparison-3n-skx-mrr"
+# tag: "NIC_Intel-XXV710"
+# comparisons:
+# - title: "Diff"
+# reference: 1
+# compare: 2
+# legend:
+# - "Legend to Table:"
+# - "x710, xxv710 - NICs tested."
+# - "Diff - difference between x710 and xxv710 NIC."
+#
+## VPP Compare NICs 3n-skx 8t4c mrr
+#- type: "table"
+# title: "VPP Compare NICs 3n-skx 8t4c mrr"
+# algorithm: "table_comparison"
+# output-file: "{DIR[STATIC,VPP]}/performance-changes-3n-skx-8t4c-nics-mrr"
+# include-tests: "MRR" # "PDR" | "NDR" | "MRR"
+# filter: "'8T4C' and 'MRR' and not 'NF_DENSITY'"
+# columns:
+# - title: "x710"
+# data-set: "vpp-nic-comparison-3n-skx-mrr"
+# tag: "NIC_Intel-X710"
+# - title: "xxv710"
+# data-set: "vpp-nic-comparison-3n-skx-mrr"
+# tag: "NIC_Intel-XXV710"
+# comparisons:
+# - title: "Diff"
+# reference: 1
+# compare: 2
+# legend:
+# - "Legend to Table:"
+# - "x710, xxv710 - NICs tested."
+# - "Diff - difference between x710 and xxv710 NIC."
# VPP Compare NICs 2n-skx 2t1c ndr
- type: "table"