aboutsummaryrefslogtreecommitdiffstats
path: root/tests/vpp/perf/ip6_tunnels/10ge2p1x520-ethip6lispip6-ip6base-pdrchk.robot
diff options
context:
space:
mode:
Diffstat (limited to 'tests/vpp/perf/ip6_tunnels/10ge2p1x520-ethip6lispip6-ip6base-pdrchk.robot')
-rw-r--r--tests/vpp/perf/ip6_tunnels/10ge2p1x520-ethip6lispip6-ip6base-pdrchk.robot193
1 files changed, 193 insertions, 0 deletions
diff --git a/tests/vpp/perf/ip6_tunnels/10ge2p1x520-ethip6lispip6-ip6base-pdrchk.robot b/tests/vpp/perf/ip6_tunnels/10ge2p1x520-ethip6lispip6-ip6base-pdrchk.robot
new file mode 100644
index 0000000000..717efedf45
--- /dev/null
+++ b/tests/vpp/perf/ip6_tunnels/10ge2p1x520-ethip6lispip6-ip6base-pdrchk.robot
@@ -0,0 +1,193 @@
+# Copyright (c) 2017 Cisco and/or its affiliates.
+# Licensed under the Apache License, Version 2.0 (the "License");
+# you may not use this file except in compliance with the License.
+# You may obtain a copy of the License at:
+#
+# http://www.apache.org/licenses/LICENSE-2.0
+#
+# Unless required by applicable law or agreed to in writing, software
+# distributed under the License is distributed on an "AS IS" BASIS,
+# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
+# See the License for the specific language governing permissions and
+# limitations under the License.
+
+*** Settings ***
+| Resource | resources/libraries/robot/performance/performance_setup.robot
+| Resource | resources/libraries/robot/overlay/lisp_static_adjacency.robot
+| Variables | resources/test_data/lisp/performance/lisp_static_adjacency.py
+| ...
+| Force Tags | 3_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | PDRCHK
+| ... | NIC_Intel-X520-DA2 | IP6FWD | ENCAP | LISP | IP6UNRLAY | IP6OVRLAY
+| ...
+| Suite Setup | Set up 3-node performance topology with DUT's NIC model
+| ... | L3 | Intel-X520-DA2
+| Suite Teardown | Tear down 3-node performance topology
+| ...
+| Test Setup | Set up performance test
+| Test Teardown | Tear down performance pdrchk test
+| ...
+| Documentation | *Reference PDR throughput Lisp tunnel verify test cases*
+| ...
+| ... | *[Top] Network Topologies:* TG-DUT1-DUT2-TG 3-node circular topology\
+| ... | with single links between nodes.
+| ... | *[Enc] Packet Encapsulations:* Eth-IPv6-LISP-IPv6 on DUT1-DUT2,\
+| ... | Eth-IPv6-ICMPv6 on TG-DUTn for IPv6 routing over LISPoIPv6 tunnel.
+| ... | *[Cfg] DUT configuration:* DUT1 and DUT2 are configured with IPv6\
+| ... | routing and static routes. LISPoIPv6 tunnel is configured\
+| ... | between DUT1 and DUT2. DUT1 and DUT2 tested with 2p10GE NIC X520\
+| ... | Niantic by Intel.
+| ... | *[Ver] TG verification:* In short performance tests, TG verifies\
+| ... | DUTs' throughput at ref-PDR (reference Non Drop Rate) with zero packet\
+| ... | loss tolerance. Ref-PDR value is periodically updated acording to\
+| ... | formula: ref-PDR = 0.9x PDR, where PDR is found in RFC2544 long\
+| ... | performance tests for the same DUT confiiguration. Test packets are\
+| ... | generated by TG on links to DUTs. TG traffic profile contains two L3\
+| ... | flow-groups (flow-group per direction, 253 flows per flow-group) with\
+| ... | all packets containing Ethernet header, IPv6 header with\
+| ... | IP protocol=61 and generated payload.
+| ... | *[Ref] Applicable standard specifications:* RFC2544.
+
+*** Variables ***
+# Traffic profile:
+| ${traffic_profile} | trex-sl-3n-ethip6-ip6src253
+
+*** Keywords ***
+| Check PDR for Lisp IPv6 over IPv6 forwarding
+| | [Documentation]
+| | ... | [Cfg] DUT runs LISP tunnel config with ${wt} thread, ${wt} phy core,\
+| | ... | ${rxq} receive queue per NIC port.
+| | ... | [Ver] Verify ref-NDR for ${framesize} Byte frames using single trial\
+| | ... | throughput test at 2x ${rate}.
+| | ...
+| | [Arguments] | ${framesize} | ${rate} | ${wt} | ${rxq}
+| | ...
+| | # Test Variables required for test and test teardown
+| | Set Test Variable | ${framesize}
+| | Set Test Variable | ${rate}
+| | ${get_framesize}= | Get Frame Size | ${framesize}
+| | ...
+| | Given Add '${wt}' worker threads and '${rxq}' rxqueues in 3-node single-link circular topology
+| | And Add PCI devices to DUTs in 3-node single link topology
+| | And Run Keyword If | ${get_framesize} < ${1522}
+| | ... | Add no multi seg to all DUTs
+| | And Apply startup configuration on all VPP DUTs
+| | When Initialize LISP IPv6 forwarding in 3-node circular topology
+| | ... | ${dut1_to_dut2_ip6} | ${dut1_to_tg_ip6} | ${dut2_to_dut1_ip6}
+| | ... | ${dut2_to_tg_ip6} | ${prefix6}
+| | And Configure LISP topology in 3-node circular topology
+| | ... | ${dut1} | ${dut1_if2} | ${NONE}
+| | ... | ${dut2} | ${dut2_if1} | ${NONE}
+| | ... | ${duts_locator_set} | ${dut1_ip6_eid} | ${dut2_ip6_eid}
+| | ... | ${dut1_ip6_static_adjacency} | ${dut2_ip6_static_adjacency}
+| | Then Traffic should pass with partial loss | ${perf_trial_duration}
+| | ... | ${rate} | ${framesize} | ${traffic_profile}
+| | ... | ${perf_pdr_loss_acceptance} | ${perf_pdr_loss_acceptance_type}
+
+*** Test Cases ***
+| tc01-78B-1t1c-ethip6lispip6-ip6base-pdrchk
+| | [Documentation]
+| | ... | [Cfg] DUT runs LISP tunnel config with 1 thread, 1 phy core,\
+| | ... | 1 receive queue per NIC port.
+| | ... | [Ver] Verify ref-NDR for 78 Byte frames using single trial\
+| | ... | throughput test at 2x ${rate}.
+| | ...
+| | [Tags] | 78B | 1T1C | STHREAD
+| | ...
+| | [Template] | Check PDR for Lisp IPv6 over IPv6 forwarding
+| | framesize=${78} | rate=1.56mpps | wt=1 | rxq=1
+
+| tc02-1460B-1t1c-ethip6lispip6-ip6base-pdrchk
+| | [Documentation]
+| | ... | [Cfg] DUT runs LISP tunnel config with 1 thread, 1 phy core,\
+| | ... | 1 receive queue per NIC port.
+| | ... | [Ver] Verify ref-NDR for 1460 Byte frames using single trial\
+| | ... | throughput test at 2x ${rate}.
+| | ...
+| | [Tags] | 1460B | 1T1C | STHREAD
+| | ...
+| | [Template] | Check PDR for Lisp IPv6 over IPv6 forwarding
+| | framesize=${1460} | rate=370000pps | wt=1 | rxq=1
+
+| tc03-9000B-1t1c-ethip6lispip6-ip6base-pdrchk
+| | [Documentation]
+| | ... | [Cfg] DUT runs LISP tunnel config with 1 thread, 1 phy core,\
+| | ... | 1 receive queue per NIC port.
+| | ... | [Ver] Verify ref-NDR for 9000 Byte frames using single trial\
+| | ... | throughput test at 2x ${rate}.
+| | ...
+| | [Tags] | 9000B | 1T1C | STHREAD
+| | ...
+| | [Template] | Check PDR for Lisp IPv6 over IPv6 forwarding
+| | framesize=${9000} | rate=60000pps | wt=1 | rxq=1
+
+| tc04-78B-2t2c-ethip6lispip6-ip6base-pdrchk
+| | [Documentation]
+| | ... | [Cfg] DUT runs LISP tunnel config with 2 thread, 2 phy core,\
+| | ... | 1 receive queue per NIC port.
+| | ... | [Ver] Verify ref-NDR for 78 Byte frames using single trial\
+| | ... | throughput test at 2x ${rate}.
+| | ...
+| | [Tags] | 78B | 2T2C | MTHREAD
+| | ...
+| | [Template] | Check PDR for Lisp IPv6 over IPv6 forwarding
+| | framesize=${78} | rate=3.2mpps | wt=2 | rxq=1
+
+| tc05-1460B-2t2c-ethip6lispip6-ip6base-pdrchk
+| | [Documentation]
+| | ... | [Cfg] DUT runs LISP tunnel config with 2 threads, 2 phy cores,\
+| | ... | 1 receive queue per NIC port.
+| | ... | [Ver] Verify ref-NDR for 1460 Byte frames using single trial\
+| | ... | throughput test at 2x ${rate}.
+| | ...
+| | [Tags] | 1460B | 2T2C | MTHREAD
+| | ...
+| | [Template] | Check PDR for Lisp IPv6 over IPv6 forwarding
+| | framesize=${1460} | rate=370000pps | wt=2 | rxq=1
+
+| tc06-9000B-2t2c-ethip6lispip6-ip6base-pdrchk
+| | [Documentation]
+| | ... | [Cfg] DUT runs LISP tunnel config with 2 threads, 2 phy cores,\
+| | ... | 1 receive queue per NIC port.
+| | ... | [Ver] Verify ref-NDR for 9000 Byte frames using single trial\
+| | ... | throughput test at 2x ${rate}.
+| | ...
+| | [Tags] | 9000B | 2T2C | MTHREAD
+| | ...
+| | [Template] | Check PDR for Lisp IPv6 over IPv6 forwarding
+| | framesize=${9000} | rate=60000pps | wt=2 | rxq=1
+
+| tc07-78B-4t4c-ethip6lispip6-ip6base-pdrchk
+| | [Documentation]
+| | ... | [Cfg] DUT runs LISP tunnel config with 4 threads, 4 phy cores,\
+| | ... | 2 receive queues per NIC port.
+| | ... | [Ver] Verify ref-NDR for 78 Byte frames using single trial\
+| | ... | throughput test at 2x ${rate}.
+| | ...
+| | [Tags] | 78B | 4T4C | MTHREAD
+| | ...
+| | [Template] | Check PDR for Lisp IPv6 over IPv6 forwarding
+| | framesize=${78} | rate=3.2mpps | wt=4 | rxq=2
+
+| tc08-1460B-4t4c-ethip6lispip6-ip6base-pdrchk
+| | [Documentation]
+| | ... | [Cfg] DUT runs LISP tunnel config with 4 threads, 4 phy cores,\
+| | ... | 2 receive queues per NIC port.
+| | ... | [Ver] Verify ref-NDR for 1460 Byte frames using single trial\
+| | ... | throughput test at 2x ${rate}.
+| | ...
+| | [Tags] | 1460B | 4T4C | MTHREAD
+| | ...
+| | [Template] | Check PDR for Lisp IPv6 over IPv6 forwarding
+| | framesize=${1460} | rate=370000pps | wt=4 | rxq=2
+
+| tc09-9000B-4t4c-ethip6lispip6-ip6base-pdrchk
+| | [Documentation]
+| | ... | [Cfg] DUT runs LISP tunnel config with 4 threads, 4 phy cores,\
+| | ... | 2 receive queues per NIC port.
+| | ... | [Ver] Verify ref-NDR for 9000 Byte frames using single trial\
+| | ... | throughput test at 2x ${rate}.
+| | ...
+| | [Tags] | 9000B | 4T4C | MTHREAD
+| | ...
+| | [Template] | Check PDR for Lisp IPv6 over IPv6 forwarding
+| | framesize=${9000} | rate=60000pps | wt=4 | rxq=2