aboutsummaryrefslogtreecommitdiffstats
path: root/tests/vpp/perf/vm_vhost
diff options
context:
space:
mode:
Diffstat (limited to 'tests/vpp/perf/vm_vhost')
-rw-r--r--tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot14
-rw-r--r--tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot14
-rw-r--r--tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2xcbase-eth-2vhostvr1024-1vm-ndrpdr.robot14
-rw-r--r--tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2xcbase-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot14
-rw-r--r--tests/vpp/perf/vm_vhost/10ge2p1x710-2lbvpplacp-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot14
-rw-r--r--tests/vpp/perf/vm_vhost/10ge2p1x710-2lbvpplacp-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot14
-rw-r--r--tests/vpp/perf/vm_vhost/10ge2p1x710-2lbvpplacp-dot1q-l2xcbase-eth-2vhostvr1024-1vm-ndrpdr.robot14
-rw-r--r--tests/vpp/perf/vm_vhost/10ge2p1x710-2lbvpplacp-dot1q-l2xcbase-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot14
-rw-r--r--tests/vpp/perf/vm_vhost/10ge2p1x710-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot14
-rw-r--r--tests/vpp/perf/vm_vhost/10ge2p1x710-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot14
-rw-r--r--tests/vpp/perf/vm_vhost/10ge2p1x710-dot1q-l2xcbase-eth-2vhostvr1024-1vm-ndrpdr.robot14
-rw-r--r--tests/vpp/perf/vm_vhost/10ge2p1x710-dot1q-l2xcbase-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot14
-rw-r--r--tests/vpp/perf/vm_vhost/10ge2p1x710-eth-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot13
-rw-r--r--tests/vpp/perf/vm_vhost/10ge2p1x710-eth-l2bdbasemaclrn-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot13
-rw-r--r--tests/vpp/perf/vm_vhost/10ge2p1x710-eth-l2xcbase-eth-2vhostvr1024-1vm-ndrpdr.robot14
-rw-r--r--tests/vpp/perf/vm_vhost/10ge2p1x710-eth-l2xcbase-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot14
-rw-r--r--tests/vpp/perf/vm_vhost/10ge2p1x710-ethip4-ip4base-eth-2vhostvr1024-1vm-ndrpdr.robot14
-rw-r--r--tests/vpp/perf/vm_vhost/10ge2p1x710-ethip4-ip4base-eth-2vhostvr1024-1vm-vppip4-ndrpdr.robot14
-rw-r--r--tests/vpp/perf/vm_vhost/10ge2p1x710-ethip4vxlan-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot14
-rw-r--r--tests/vpp/perf/vm_vhost/10ge2p1x710-ethip4vxlan-l2bdbasemaclrn-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot14
-rw-r--r--tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot14
-rw-r--r--tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot14
-rw-r--r--tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-eth-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot13
-rw-r--r--tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-eth-l2bdbasemaclrn-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot13
-rw-r--r--tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-eth-l2xcbase-eth-2vhostvr1024-1vm-ndrpdr.robot14
-rw-r--r--tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-eth-l2xcbase-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot14
-rw-r--r--tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-ethip4-ip4base-eth-2vhostvr1024-1vm-ndrpdr.robot14
-rw-r--r--tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-ethip4-ip4base-eth-2vhostvr1024-1vm-vppip4-ndrpdr.robot14
28 files changed, 220 insertions, 168 deletions
diff --git a/tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot b/tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot
index 9da3a8787d..98717be886 100644
--- a/tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot
+++ b/tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot
@@ -17,7 +17,7 @@
| Force Tags | 3_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | NDRPDR
| ... | NIC_Intel-X710 | DOT1Q | L2BDMACLRN | BASE | VHOST | 1VM
| ... | VHOST_1024 | LBOND | LBOND_VPP | LBOND_MODE_LACP | LBOND_LB_L34
-| ... | LBOND_1L | VM_TESTPMD
+| ... | LBOND_1L | VM_TESTPMD | DRV_VFIO_PCI
| ...
| Suite Setup | Setup suite single link | performance
| Suite Teardown | Tear down suite | performance
@@ -53,9 +53,10 @@
*** Variables ***
| @{plugins_to_enable}= | dpdk_plugin.so | lacp_plugin.so
-| ${osi_layer}= | L2
+| ${crypto_type}= | ${None}
| ${nic_name}= | Intel-X710
| ${nic_driver}= | vfio-pci
+| ${osi_layer}= | L2
| ${overhead}= | ${4}
| ${subid}= | 10
| ${tag_rewrite}= | pop-1
@@ -88,12 +89,13 @@
| | ...
| | Set Test Variable | \${frame_size}
| | ...
-| | Given Add worker threads and rxqueues to all DUTs | ${phy_cores} | ${rxq}
-| | And Add PCI devices to all DUTs
+| | Given Set Max Rate And Jumbo
+| | And Add worker threads to all DUTs | ${phy_cores} | ${rxq}
+| | And Pre-initialize layer driver | ${nic_driver}
| | And Add VLAN Strip Offload switch off between DUTs in 3-node single link topology
-| | And Set Max Rate And Jumbo And Handle Multi Seg
| | And Apply startup configuration on all VPP DUTs
-| | When Initialize layer driver | vfio-pci
+| | When Initialize layer driver | ${nic_driver}
+| | And Initialize layer interface
| | And Initialize L2 bridge domains with Vhost-User and VLAN with VPP link bonding in a 3-node circular topology
| | ... | ${bd_id1} | ${bd_id2} | ${subid}
| | ... | ${tag_rewrite} | ${bond_mode} | ${lb_mode}
diff --git a/tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot b/tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot
index c308a54535..aca6ad6d98 100644
--- a/tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot
+++ b/tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot
@@ -17,7 +17,7 @@
| Force Tags | 3_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | NDRPDR
| ... | NIC_Intel-X710 | DOT1Q | L2BDMACLRN | BASE | VHOST | 1VM
| ... | VHOST_1024 | LBOND | LBOND_VPP | LBOND_MODE_LACP | LBOND_LB_L34
-| ... | LBOND_1L | NF_VPPL2XC
+| ... | LBOND_1L | NF_VPPL2XC | DRV_VFIO_PCI
| ...
| Suite Setup | Setup suite single link | performance
| Suite Teardown | Tear down suite | performance
@@ -53,9 +53,10 @@
*** Variables ***
| @{plugins_to_enable}= | dpdk_plugin.so | lacp_plugin.so
-| ${osi_layer}= | L2
+| ${crypto_type}= | ${None}
| ${nic_name}= | Intel-X710
| ${nic_driver}= | vfio-pci
+| ${osi_layer}= | L2
| ${overhead}= | ${4}
| ${subid}= | 10
| ${tag_rewrite}= | pop-1
@@ -88,12 +89,13 @@
| | ...
| | Set Test Variable | \${frame_size}
| | ...
-| | Given Add worker threads and rxqueues to all DUTs | ${phy_cores} | ${rxq}
-| | And Add PCI devices to all DUTs
+| | Given Set Max Rate And Jumbo
+| | And Add worker threads to all DUTs | ${phy_cores} | ${rxq}
+| | And Pre-initialize layer driver | ${nic_driver}
| | And Add VLAN Strip Offload switch off between DUTs in 3-node single link topology
-| | And Set Max Rate And Jumbo And Handle Multi Seg
| | And Apply startup configuration on all VPP DUTs
-| | When Initialize layer driver | vfio-pci
+| | When Initialize layer driver | ${nic_driver}
+| | And Initialize layer interface
| | And Initialize L2 bridge domains with Vhost-User and VLAN with VPP link bonding in a 3-node circular topology
| | ... | ${bd_id1} | ${bd_id2} | ${subid}
| | ... | ${tag_rewrite} | ${bond_mode} | ${lb_mode}
diff --git a/tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2xcbase-eth-2vhostvr1024-1vm-ndrpdr.robot b/tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2xcbase-eth-2vhostvr1024-1vm-ndrpdr.robot
index a9c723b979..9ce108415f 100644
--- a/tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2xcbase-eth-2vhostvr1024-1vm-ndrpdr.robot
+++ b/tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2xcbase-eth-2vhostvr1024-1vm-ndrpdr.robot
@@ -17,7 +17,7 @@
| Force Tags | 3_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | NDRPDR
| ... | NIC_Intel-X710 | DOT1Q | L2XCFWD | BASE | VHOST | 1VM
| ... | VHOST_1024 | LBOND | LBOND_VPP | LBOND_MODE_LACP | LBOND_LB_L34
-| ... | LBOND_1L | NF_TESTPMD
+| ... | LBOND_1L | NF_TESTPMD | DRV_VFIO_PCI
| ...
| Suite Setup | Setup suite single link | performance
| Suite Teardown | Tear down suite | performance
@@ -53,9 +53,10 @@
*** Variables ***
| @{plugins_to_enable}= | dpdk_plugin.so | lacp_plugin.so
-| ${osi_layer}= | L2
+| ${crypto_type}= | ${None}
| ${nic_name}= | Intel-X710
| ${nic_driver}= | vfio-pci
+| ${osi_layer}= | L2
| ${overhead}= | ${4}
| ${subid}= | 10
| ${tag_rewrite}= | pop-1
@@ -86,12 +87,13 @@
| | ...
| | Set Test Variable | \${frame_size}
| | ...
-| | Given Add worker threads and rxqueues to all DUTs | ${phy_cores} | ${rxq}
-| | And Add PCI devices to all DUTs
+| | Given Set Max Rate And Jumbo
+| | And Add worker threads to all DUTs | ${phy_cores} | ${rxq}
+| | And Pre-initialize layer driver | ${nic_driver}
| | And Add VLAN Strip Offload switch off between DUTs in 3-node single link topology
-| | And Set Max Rate And Jumbo And Handle Multi Seg
| | And Apply startup configuration on all VPP DUTs
-| | When Initialize layer driver | vfio-pci
+| | When Initialize layer driver | ${nic_driver}
+| | And Initialize layer interface
| | And Initialize L2 xconnect with Vhost-User and VLAN with VPP link bonding in 3-node circular topology
| | ... | ${subid} | ${tag_rewrite} | ${bond_mode} | ${lb_mode}
| | And Configure chains of NFs connected via vhost-user
diff --git a/tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2xcbase-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot b/tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2xcbase-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot
index 6c753cbf1c..c57d10c851 100644
--- a/tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2xcbase-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot
+++ b/tests/vpp/perf/vm_vhost/10ge2p1x710-1lbvpplacp-dot1q-l2xcbase-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot
@@ -17,7 +17,7 @@
| Force Tags | 3_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | NDRPDR
| ... | NIC_Intel-X710 | DOT1Q | L2XCFWD | BASE | VHOST | 1VM
| ... | VHOST_1024 | LBOND | LBOND_VPP | LBOND_MODE_LACP | LBOND_LB_L34
-| ... | LBOND_1L | NF_VPPL2XC
+| ... | LBOND_1L | NF_VPPL2XC | DRV_VFIO_PCI
| ...
| Suite Setup | Setup suite single link | performance
| Suite Teardown | Tear down suite | performance
@@ -53,9 +53,10 @@
*** Variables ***
| @{plugins_to_enable}= | dpdk_plugin.so | lacp_plugin.so
-| ${osi_layer}= | L2
+| ${crypto_type}= | ${None}
| ${nic_name}= | Intel-X710
| ${nic_driver}= | vfio-pci
+| ${osi_layer}= | L2
| ${overhead}= | ${4}
| ${subid}= | 10
| ${tag_rewrite}= | pop-1
@@ -86,12 +87,13 @@
| | ...
| | Set Test Variable | \${frame_size}
| | ...
-| | Given Add worker threads and rxqueues to all DUTs | ${phy_cores} | ${rxq}
-| | And Add PCI devices to all DUTs
+| | Given Set Max Rate And Jumbo
+| | And Add worker threads to all DUTs | ${phy_cores} | ${rxq}
+| | And Pre-initialize layer driver | ${nic_driver}
| | And Add VLAN Strip Offload switch off between DUTs in 3-node single link topology
-| | And Set Max Rate And Jumbo And Handle Multi Seg
| | And Apply startup configuration on all VPP DUTs
-| | When Initialize layer driver | vfio-pci
+| | When Initialize layer driver | ${nic_driver}
+| | And Initialize layer interface
| | And Initialize L2 xconnect with Vhost-User and VLAN with VPP link bonding in 3-node circular topology
| | ... | ${subid} | ${tag_rewrite} | ${bond_mode} | ${lb_mode}
| | And Configure chains of NFs connected via vhost-user
diff --git a/tests/vpp/perf/vm_vhost/10ge2p1x710-2lbvpplacp-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot b/tests/vpp/perf/vm_vhost/10ge2p1x710-2lbvpplacp-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot
index a40829235b..15915c1db9 100644
--- a/tests/vpp/perf/vm_vhost/10ge2p1x710-2lbvpplacp-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot
+++ b/tests/vpp/perf/vm_vhost/10ge2p1x710-2lbvpplacp-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot
@@ -17,7 +17,7 @@
| Force Tags | 3_NODE_DOUBLE_LINK_TOPO | PERFTEST | HW_ENV | NDRPDR
| ... | NIC_Intel-X710 | DOT1Q | L2BDMACLRN | BASE | VHOST | 1VM
| ... | VHOST_1024 | LBOND | LBOND_VPP | LBOND_MODE_LACP | LBOND_LB_L34
-| ... | LBOND_2L | VM_TESTPMD
+| ... | LBOND_2L | VM_TESTPMD | DRV_VFIO_PCI
| ...
| Suite Setup | Setup suite double link | performance
| Suite Teardown | Tear down suite | performance
@@ -54,9 +54,10 @@
*** Variables ***
| @{plugins_to_enable}= | dpdk_plugin.so | lacp_plugin.so
-| ${osi_layer}= | L2
+| ${crypto_type}= | ${None}
| ${nic_name}= | Intel-X710
| ${nic_driver}= | vfio-pci
+| ${osi_layer}= | L2
| ${overhead}= | ${4}
| ${subid}= | 10
| ${tag_rewrite}= | pop-1
@@ -89,12 +90,13 @@
| | ...
| | Set Test Variable | \${frame_size}
| | ...
-| | Given Add worker threads and rxqueues to all DUTs | ${phy_cores} | ${rxq}
-| | And Add PCI devices to all DUTs
+| | Given Set Max Rate And Jumbo
+| | And Add worker threads to all DUTs | ${phy_cores} | ${rxq}
+| | And Pre-initialize layer driver | ${nic_driver}
| | And Add VLAN Strip Offload switch off between DUTs in 3-node double link topology
-| | And Set Max Rate And Jumbo And Handle Multi Seg
| | And Apply startup configuration on all VPP DUTs
-| | When Initialize layer driver | vfio-pci
+| | When Initialize layer driver | ${nic_driver}
+| | And Initialize layer interface
| | And Initialize L2 bridge domains with Vhost-User and VLAN with VPP link bonding in a 3-node circular topology
| | ... | ${bd_id1} | ${bd_id2} | ${subid}
| | ... | ${tag_rewrite} | ${bond_mode} | ${lb_mode}
diff --git a/tests/vpp/perf/vm_vhost/10ge2p1x710-2lbvpplacp-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot b/tests/vpp/perf/vm_vhost/10ge2p1x710-2lbvpplacp-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot
index 5eca71c9df..8d3b48ea0c 100644
--- a/tests/vpp/perf/vm_vhost/10ge2p1x710-2lbvpplacp-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot
+++ b/tests/vpp/perf/vm_vhost/10ge2p1x710-2lbvpplacp-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot
@@ -17,7 +17,7 @@
| Force Tags | 3_NODE_DOUBLE_LINK_TOPO | PERFTEST | HW_ENV | NDRPDR
| ... | NIC_Intel-X710 | DOT1Q | L2BDMACLRN | BASE | VHOST | 1VM
| ... | VHOST_1024 | LBOND | LBOND_VPP | LBOND_MODE_LACP | LBOND_LB_L34
-| ... | LBOND_2L | NF_VPPL2XC
+| ... | LBOND_2L | NF_VPPL2XC | DRV_VFIO_PCI
| ...
| Suite Setup | Setup suite double link | performance
| Suite Teardown | Tear down suite | performance
@@ -54,9 +54,10 @@
*** Variables ***
| @{plugins_to_enable}= | dpdk_plugin.so | lacp_plugin.so
-| ${osi_layer}= | L2
+| ${crypto_type}= | ${None}
| ${nic_name}= | Intel-X710
| ${nic_driver}= | vfio-pci
+| ${osi_layer}= | L2
| ${overhead}= | ${4}
| ${subid}= | 10
| ${tag_rewrite}= | pop-1
@@ -89,12 +90,13 @@
| | ...
| | Set Test Variable | \${frame_size}
| | ...
-| | Given Add worker threads and rxqueues to all DUTs | ${phy_cores} | ${rxq}
-| | And Add PCI devices to all DUTs
+| | Given Set Max Rate And Jumbo
+| | And Add worker threads to all DUTs | ${phy_cores} | ${rxq}
+| | And Pre-initialize layer driver | ${nic_driver}
| | And Add VLAN Strip Offload switch off between DUTs in 3-node double link topology
-| | And Set Max Rate And Jumbo And Handle Multi Seg
| | And Apply startup configuration on all VPP DUTs
-| | When Initialize layer driver | vfio-pci
+| | When Initialize layer driver | ${nic_driver}
+| | And Initialize layer interface
| | And Initialize L2 bridge domains with Vhost-User and VLAN with VPP link bonding in a 3-node circular topology
| | ... | ${bd_id1} | ${bd_id2} | ${subid}
| | ... | ${tag_rewrite} | ${bond_mode} | ${lb_mode}
diff --git a/tests/vpp/perf/vm_vhost/10ge2p1x710-2lbvpplacp-dot1q-l2xcbase-eth-2vhostvr1024-1vm-ndrpdr.robot b/tests/vpp/perf/vm_vhost/10ge2p1x710-2lbvpplacp-dot1q-l2xcbase-eth-2vhostvr1024-1vm-ndrpdr.robot
index 7cf79c904c..c5d8e65fa0 100644
--- a/tests/vpp/perf/vm_vhost/10ge2p1x710-2lbvpplacp-dot1q-l2xcbase-eth-2vhostvr1024-1vm-ndrpdr.robot
+++ b/tests/vpp/perf/vm_vhost/10ge2p1x710-2lbvpplacp-dot1q-l2xcbase-eth-2vhostvr1024-1vm-ndrpdr.robot
@@ -17,7 +17,7 @@
| Force Tags | 3_NODE_DOUBLE_LINK_TOPO | PERFTEST | HW_ENV | NDRPDR
| ... | NIC_Intel-X710 | DOT1Q | L2XCFWD | BASE | VHOST | 1VM
| ... | VHOST_1024 | LBOND | LBOND_VPP | LBOND_MODE_LACP | LBOND_LB_L34
-| ... | LBOND_2L | NF_TESTPMD
+| ... | LBOND_2L | NF_TESTPMD | DRV_VFIO_PCI
| ...
| Suite Setup | Setup suite double link | performance
| Suite Teardown | Tear down suite | performance
@@ -54,9 +54,10 @@
*** Variables ***
| @{plugins_to_enable}= | dpdk_plugin.so | lacp_plugin.so
-| ${osi_layer}= | L2
+| ${crypto_type}= | ${None}
| ${nic_name}= | Intel-X710
| ${nic_driver}= | vfio-pci
+| ${osi_layer}= | L2
| ${overhead}= | ${4}
| ${subid}= | 10
| ${tag_rewrite}= | pop-1
@@ -87,12 +88,13 @@
| | ...
| | Set Test Variable | \${frame_size}
| | ...
-| | Given Add worker threads and rxqueues to all DUTs | ${phy_cores} | ${rxq}
-| | And Add PCI devices to all DUTs
+| | Given Set Max Rate And Jumbo
+| | And Add worker threads to all DUTs | ${phy_cores} | ${rxq}
+| | And Pre-initialize layer driver | ${nic_driver}
| | And Add VLAN Strip Offload switch off between DUTs in 3-node double link topology
-| | And Set Max Rate And Jumbo And Handle Multi Seg
| | And Apply startup configuration on all VPP DUTs
-| | When Initialize layer driver | vfio-pci
+| | When Initialize layer driver | ${nic_driver}
+| | And Initialize layer interface
| | And Initialize L2 xconnect with Vhost-User and VLAN with VPP link bonding in 3-node circular topology
| | ... | ${subid} | ${tag_rewrite} | ${bond_mode} | ${lb_mode}
| | And Configure chains of NFs connected via vhost-user
diff --git a/tests/vpp/perf/vm_vhost/10ge2p1x710-2lbvpplacp-dot1q-l2xcbase-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot b/tests/vpp/perf/vm_vhost/10ge2p1x710-2lbvpplacp-dot1q-l2xcbase-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot
index 2084d8f1da..3ec3d9c075 100644
--- a/tests/vpp/perf/vm_vhost/10ge2p1x710-2lbvpplacp-dot1q-l2xcbase-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot
+++ b/tests/vpp/perf/vm_vhost/10ge2p1x710-2lbvpplacp-dot1q-l2xcbase-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot
@@ -17,7 +17,7 @@
| Force Tags | 3_NODE_DOUBLE_LINK_TOPO | PERFTEST | HW_ENV | NDRPDR
| ... | NIC_Intel-X710 | DOT1Q | L2XCFWD | BASE | VHOST | 1VM
| ... | VHOST_1024 | LBOND | LBOND_VPP | LBOND_MODE_LACP | LBOND_LB_L34
-| ... | LBOND_2L | NF_VPPL2XC
+| ... | LBOND_2L | NF_VPPL2XC | DRV_VFIO_PCI
| ...
| Suite Setup | Setup suite double link | performance
| Suite Teardown | Tear down suite | performance
@@ -54,9 +54,10 @@
*** Variables ***
| @{plugins_to_enable}= | dpdk_plugin.so | lacp_plugin.so
-| ${osi_layer}= | L2
+| ${crypto_type}= | ${None}
| ${nic_name}= | Intel-X710
| ${nic_driver}= | vfio-pci
+| ${osi_layer}= | L2
| ${overhead}= | ${4}
| ${subid}= | 10
| ${tag_rewrite}= | pop-1
@@ -87,12 +88,13 @@
| | ...
| | Set Test Variable | \${frame_size}
| | ...
-| | Given Add worker threads and rxqueues to all DUTs | ${phy_cores} | ${rxq}
-| | And Add PCI devices to all DUTs
+| | Given Set Max Rate And Jumbo
+| | And Add worker threads to all DUTs | ${phy_cores} | ${rxq}
+| | And Pre-initialize layer driver | ${nic_driver}
| | And Add VLAN Strip Offload switch off between DUTs in 3-node double link topology
-| | And Set Max Rate And Jumbo And Handle Multi Seg
| | And Apply startup configuration on all VPP DUTs
-| | When Initialize layer driver | vfio-pci
+| | When Initialize layer driver | ${nic_driver}
+| | And Initialize layer interface
| | And Initialize L2 xconnect with Vhost-User and VLAN with VPP link bonding in 3-node circular topology
| | ... | ${subid} | ${tag_rewrite} | ${bond_mode} | ${lb_mode}
| | And Configure chains of NFs connected via vhost-user
diff --git a/tests/vpp/perf/vm_vhost/10ge2p1x710-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot b/tests/vpp/perf/vm_vhost/10ge2p1x710-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot
index bdb0e17a42..28c2a06c04 100644
--- a/tests/vpp/perf/vm_vhost/10ge2p1x710-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot
+++ b/tests/vpp/perf/vm_vhost/10ge2p1x710-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot
@@ -16,7 +16,7 @@
| ...
| Force Tags | 3_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | NDRPDR
| ... | NIC_Intel-X710 | DOT1Q | L2BDMACLRN | BASE | VHOST | 1VM
-| ... | VHOST_1024 | NF_TESTPMD
+| ... | VHOST_1024 | NF_TESTPMD | DRV_VFIO_PCI
| ...
| Suite Setup | Setup suite single link | performance
| Suite Teardown | Tear down suite | performance
@@ -52,9 +52,10 @@
*** Variables ***
| @{plugins_to_enable}= | dpdk_plugin.so
-| ${osi_layer}= | L2
+| ${crypto_type}= | ${None}
| ${nic_name}= | Intel-X710
| ${nic_driver}= | vfio-pci
+| ${osi_layer}= | L2
| ${overhead}= | ${4}
| ${subid}= | 10
| ${tag_rewrite}= | pop-1
@@ -84,11 +85,12 @@
| | ...
| | Set Test Variable | \${frame_size}
| | ...
-| | Given Add worker threads and rxqueues to all DUTs | ${phy_cores} | ${rxq}
-| | And Add PCI devices to all DUTs
-| | And Set Max Rate And Jumbo And Handle Multi Seg
+| | Given Set Max Rate And Jumbo
+| | And Add worker threads to all DUTs | ${phy_cores} | ${rxq}
+| | And Pre-initialize layer driver | ${nic_driver}
| | And Apply startup configuration on all VPP DUTs
-| | When Initialize layer driver | vfio-pci
+| | When Initialize layer driver | ${nic_driver}
+| | And Initialize layer interface
| | And Initialize L2 bridge domains with Vhost-User and VLAN in circular topology
| | ... | ${bd_id1} | ${bd_id2} | ${subid} | ${tag_rewrite}
| | And Configure chains of NFs connected via vhost-user
diff --git a/tests/vpp/perf/vm_vhost/10ge2p1x710-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot b/tests/vpp/perf/vm_vhost/10ge2p1x710-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot
index 4751d14163..8dfe92171f 100644
--- a/tests/vpp/perf/vm_vhost/10ge2p1x710-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot
+++ b/tests/vpp/perf/vm_vhost/10ge2p1x710-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot
@@ -16,7 +16,7 @@
| ...
| Force Tags | 3_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | NDRPDR
| ... | NIC_Intel-X710 | DOT1Q | L2BDMACLRN | BASE | VHOST | 1VM
-| ... | VHOST_1024 | NF_VPPL2XC
+| ... | VHOST_1024 | NF_VPPL2XC | DRV_VFIO_PCI
| ...
| Suite Setup | Setup suite single link | performance
| Suite Teardown | Tear down suite | performance
@@ -52,9 +52,10 @@
*** Variables ***
| @{plugins_to_enable}= | dpdk_plugin.so
-| ${osi_layer}= | L2
+| ${crypto_type}= | ${None}
| ${nic_name}= | Intel-X710
| ${nic_driver}= | vfio-pci
+| ${osi_layer}= | L2
| ${overhead}= | ${4}
| ${subid}= | 10
| ${tag_rewrite}= | pop-1
@@ -84,11 +85,12 @@
| | ...
| | Set Test Variable | \${frame_size}
| | ...
-| | Given Add worker threads and rxqueues to all DUTs | ${phy_cores} | ${rxq}
-| | And Add PCI devices to all DUTs
-| | And Set Max Rate And Jumbo And Handle Multi Seg
+| | Given Set Max Rate And Jumbo
+| | And Add worker threads to all DUTs | ${phy_cores} | ${rxq}
+| | And Pre-initialize layer driver | ${nic_driver}
| | And Apply startup configuration on all VPP DUTs
-| | When Initialize layer driver | vfio-pci
+| | When Initialize layer driver | ${nic_driver}
+| | And Initialize layer interface
| | And Initialize L2 bridge domains with Vhost-User and VLAN in circular topology
| | ... | ${bd_id1} | ${bd_id2} | ${subid} | ${tag_rewrite}
| | And Configure chains of NFs connected via vhost-user
diff --git a/tests/vpp/perf/vm_vhost/10ge2p1x710-dot1q-l2xcbase-eth-2vhostvr1024-1vm-ndrpdr.robot b/tests/vpp/perf/vm_vhost/10ge2p1x710-dot1q-l2xcbase-eth-2vhostvr1024-1vm-ndrpdr.robot
index 3897e2228f..1f723fe38d 100644
--- a/tests/vpp/perf/vm_vhost/10ge2p1x710-dot1q-l2xcbase-eth-2vhostvr1024-1vm-ndrpdr.robot
+++ b/tests/vpp/perf/vm_vhost/10ge2p1x710-dot1q-l2xcbase-eth-2vhostvr1024-1vm-ndrpdr.robot
@@ -16,7 +16,7 @@
| ...
| Force Tags | 3_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | NDRPDR
| ... | NIC_Intel-X710 | DOT1Q | L2XCFWD | BASE | VHOST | 1VM | VHOST_1024
-| ... | NF_TESTPMD
+| ... | NF_TESTPMD | DRV_VFIO_PCI
| ...
| Suite Setup | Setup suite single link | performance
| Suite Teardown | Tear down suite | performance
@@ -50,9 +50,10 @@
*** Variables ***
| @{plugins_to_enable}= | dpdk_plugin.so
-| ${osi_layer}= | L2
+| ${crypto_type}= | ${None}
| ${nic_name}= | Intel-X710
| ${nic_driver}= | vfio-pci
+| ${osi_layer}= | L2
| ${overhead}= | ${4}
| ${subid}= | 10
| ${tag_rewrite}= | pop-1
@@ -80,11 +81,12 @@
| | ...
| | Set Test Variable | \${frame_size}
| | ...
-| | Given Add worker threads and rxqueues to all DUTs | ${phy_cores} | ${rxq}
-| | And Add PCI devices to all DUTs
-| | And Set Max Rate And Jumbo And Handle Multi Seg
+| | Given Set Max Rate And Jumbo
+| | And Add worker threads to all DUTs | ${phy_cores} | ${rxq}
+| | And Pre-initialize layer driver | ${nic_driver}
| | And Apply startup configuration on all VPP DUTs
-| | When Initialize layer driver | vfio-pci
+| | When Initialize layer driver | ${nic_driver}
+| | And Initialize layer interface
| | And Initialize L2 xconnect with Vhost-User and VLAN in 3-node circular topology
| | ... | ${subid} | ${tag_rewrite}
| | And Configure chains of NFs connected via vhost-user
diff --git a/tests/vpp/perf/vm_vhost/10ge2p1x710-dot1q-l2xcbase-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot b/tests/vpp/perf/vm_vhost/10ge2p1x710-dot1q-l2xcbase-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot
index 8511069d6b..7e9af95798 100644
--- a/tests/vpp/perf/vm_vhost/10ge2p1x710-dot1q-l2xcbase-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot
+++ b/tests/vpp/perf/vm_vhost/10ge2p1x710-dot1q-l2xcbase-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot
@@ -16,7 +16,7 @@
| ...
| Force Tags | 3_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | NDRPDR
| ... | NIC_Intel-X710 | DOT1Q | L2XCFWD | BASE | VHOST | 1VM | VHOST_1024
-| ... | NF_VPPL2XC
+| ... | NF_VPPL2XC | DRV_VFIO_PCI
| ...
| Suite Setup | Setup suite single link | performance
| Suite Teardown | Tear down suite | performance
@@ -50,9 +50,10 @@
*** Variables ***
| @{plugins_to_enable}= | dpdk_plugin.so
-| ${osi_layer}= | L2
+| ${crypto_type}= | ${None}
| ${nic_name}= | Intel-X710
| ${nic_driver}= | vfio-pci
+| ${osi_layer}= | L2
| ${overhead}= | ${4}
| ${subid}= | 10
| ${tag_rewrite}= | pop-1
@@ -80,11 +81,12 @@
| | ...
| | Set Test Variable | \${frame_size}
| | ...
-| | Given Add worker threads and rxqueues to all DUTs | ${phy_cores} | ${rxq}
-| | And Add PCI devices to all DUTs
-| | And Set Max Rate And Jumbo And Handle Multi Seg
+| | Given Set Max Rate And Jumbo
+| | And Add worker threads to all DUTs | ${phy_cores} | ${rxq}
+| | And Pre-initialize layer driver | ${nic_driver}
| | And Apply startup configuration on all VPP DUTs
-| | When Initialize layer driver | vfio-pci
+| | When Initialize layer driver | ${nic_driver}
+| | And Initialize layer interface
| | And Initialize L2 xconnect with Vhost-User and VLAN in 3-node circular topology
| | ... | ${subid} | ${tag_rewrite}
| | And Configure chains of NFs connected via vhost-user
diff --git a/tests/vpp/perf/vm_vhost/10ge2p1x710-eth-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot b/tests/vpp/perf/vm_vhost/10ge2p1x710-eth-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot
index ee1fe539c4..ef19a8253b 100644
--- a/tests/vpp/perf/vm_vhost/10ge2p1x710-eth-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot
+++ b/tests/vpp/perf/vm_vhost/10ge2p1x710-eth-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot
@@ -16,7 +16,7 @@
| ...
| Force Tags | 3_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | NDRPDR
| ... | NIC_Intel-X710 | ETH | L2BDMACLRN | BASE | VHOST | 1VM | VHOST_1024
-| ... | NF_TESTPMD
+| ... | NF_TESTPMD | DRV_VFIO_PCI
| ...
| Suite Setup | Setup suite single link | performance
| Suite Teardown | Tear down suite | performance
@@ -50,9 +50,10 @@
*** Variables ***
| @{plugins_to_enable}= | dpdk_plugin.so
-| ${osi_layer}= | L2
+| ${crypto_type}= | ${None}
| ${nic_name}= | Intel-X710
| ${nic_driver}= | vfio-pci
+| ${osi_layer}= | L2
| ${overhead}= | ${0}
| ${nf_dtcr}= | ${1}
| ${nf_dtc}= | ${1}
@@ -78,11 +79,11 @@
| | ...
| | Set Test Variable | \${frame_size}
| | ...
-| | Given Add worker threads and rxqueues to all DUTs | ${phy_cores} | ${rxq}
-| | And Add PCI devices to all DUTs
-| | And Set Max Rate And Jumbo And Handle Multi Seg
+| | Given Set Max Rate And Jumbo
+| | And Add worker threads to all DUTs | ${phy_cores} | ${rxq}
+| | And Pre-initialize layer driver | ${nic_driver}
| | And Apply startup configuration on all VPP DUTs
-| | When Initialize layer driver | vfio-pci
+| | When Initialize layer driver | ${nic_driver}
| | And Initialize layer interface
| | ... | count=${nf_chains}
| | And Initialize L2 bridge domains for multiple chains with Vhost-User
diff --git a/tests/vpp/perf/vm_vhost/10ge2p1x710-eth-l2bdbasemaclrn-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot b/tests/vpp/perf/vm_vhost/10ge2p1x710-eth-l2bdbasemaclrn-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot
index 0a88172c48..d6fd922dd3 100644
--- a/tests/vpp/perf/vm_vhost/10ge2p1x710-eth-l2bdbasemaclrn-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot
+++ b/tests/vpp/perf/vm_vhost/10ge2p1x710-eth-l2bdbasemaclrn-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot
@@ -16,7 +16,7 @@
| ...
| Force Tags | 3_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | NDRPDR
| ... | NIC_Intel-X710 | ETH | L2BDMACLRN | BASE | VHOST | 1VM | VHOST_1024
-| ... | NF_VPPL2XC
+| ... | NF_VPPL2XC | DRV_VFIO_PCI
| ...
| Suite Setup | Setup suite single link | performance
| Suite Teardown | Tear down suite | performance
@@ -50,9 +50,10 @@
*** Variables ***
| @{plugins_to_enable}= | dpdk_plugin.so
-| ${osi_layer}= | L2
+| ${crypto_type}= | ${None}
| ${nic_name}= | Intel-X710
| ${nic_driver}= | vfio-pci
+| ${osi_layer}= | L2
| ${overhead}= | ${0}
| ${nf_dtcr}= | ${1}
| ${nf_dtc}= | ${1}
@@ -78,11 +79,11 @@
| | ...
| | Set Test Variable | \${frame_size}
| | ...
-| | Given Add worker threads and rxqueues to all DUTs | ${phy_cores} | ${rxq}
-| | And Add PCI devices to all DUTs
-| | And Set Max Rate And Jumbo And Handle Multi Seg
+| | Given Set Max Rate And Jumbo
+| | And Add worker threads to all DUTs | ${phy_cores} | ${rxq}
+| | And Pre-initialize layer driver | ${nic_driver}
| | And Apply startup configuration on all VPP DUTs
-| | When Initialize layer driver | vfio-pci
+| | When Initialize layer driver | ${nic_driver}
| | And Initialize layer interface
| | ... | count=${nf_chains}
| | And Initialize L2 bridge domains for multiple chains with Vhost-User
diff --git a/tests/vpp/perf/vm_vhost/10ge2p1x710-eth-l2xcbase-eth-2vhostvr1024-1vm-ndrpdr.robot b/tests/vpp/perf/vm_vhost/10ge2p1x710-eth-l2xcbase-eth-2vhostvr1024-1vm-ndrpdr.robot
index a167933224..226231e6c1 100644
--- a/tests/vpp/perf/vm_vhost/10ge2p1x710-eth-l2xcbase-eth-2vhostvr1024-1vm-ndrpdr.robot
+++ b/tests/vpp/perf/vm_vhost/10ge2p1x710-eth-l2xcbase-eth-2vhostvr1024-1vm-ndrpdr.robot
@@ -16,7 +16,7 @@
| ...
| Force Tags | 3_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | NDRPDR
| ... | NIC_Intel-X710 | ETH | L2XCFWD | BASE | VHOST | 1VM | VHOST_1024
-| ... | NF_TESTPMD
+| ... | NF_TESTPMD | DRV_VFIO_PCI
| ...
| Suite Setup | Setup suite single link | performance
| Suite Teardown | Tear down suite | performance
@@ -49,9 +49,10 @@
*** Variables ***
| @{plugins_to_enable}= | dpdk_plugin.so
-| ${osi_layer}= | L2
+| ${crypto_type}= | ${None}
| ${nic_name}= | Intel-X710
| ${nic_driver}= | vfio-pci
+| ${osi_layer}= | L2
| ${overhead}= | ${0}
| ${nf_dtcr}= | ${1}
| ${nf_dtc}= | ${1}
@@ -77,11 +78,12 @@
| | ...
| | Set Test Variable | \${frame_size}
| | ...
-| | Given Add worker threads and rxqueues to all DUTs | ${phy_cores} | ${rxq}
-| | And Add PCI devices to all DUTs
-| | And Set Max Rate And Jumbo And Handle Multi Seg
+| | Given Set Max Rate And Jumbo
+| | And Add worker threads to all DUTs | ${phy_cores} | ${rxq}
+| | And Pre-initialize layer driver | ${nic_driver}
| | And Apply startup configuration on all VPP DUTs
-| | When Initialize layer driver | vfio-pci
+| | When Initialize layer driver | ${nic_driver}
+| | And Initialize layer interface
| | And Initialize L2 xconnect with Vhost-User | nf_nodes=${nf_nodes}
| | And Configure chains of NFs connected via vhost-user
| | ... | nf_chains=${nf_chains} | nf_nodes=${nf_nodes} | jumbo=${jumbo}
diff --git a/tests/vpp/perf/vm_vhost/10ge2p1x710-eth-l2xcbase-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot b/tests/vpp/perf/vm_vhost/10ge2p1x710-eth-l2xcbase-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot
index 4a06f36e96..0f93baf698 100644
--- a/tests/vpp/perf/vm_vhost/10ge2p1x710-eth-l2xcbase-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot
+++ b/tests/vpp/perf/vm_vhost/10ge2p1x710-eth-l2xcbase-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot
@@ -16,7 +16,7 @@
| ...
| Force Tags | 3_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | NDRPDR
| ... | NIC_Intel-X710 | ETH | L2XCFWD | BASE | VHOST | 1VM | VHOST_1024
-| ... | NF_VPPL2XC
+| ... | NF_VPPL2XC | DRV_VFIO_PCI
| ...
| Suite Setup | Setup suite single link | performance
| Suite Teardown | Tear down suite | performance
@@ -49,9 +49,10 @@
*** Variables ***
| @{plugins_to_enable}= | dpdk_plugin.so
-| ${osi_layer}= | L2
+| ${crypto_type}= | ${None}
| ${nic_name}= | Intel-X710
| ${nic_driver}= | vfio-pci
+| ${osi_layer}= | L2
| ${overhead}= | ${0}
| ${nf_dtcr}= | ${1}
| ${nf_dtc}= | ${1}
@@ -77,11 +78,12 @@
| | ...
| | Set Test Variable | \${frame_size}
| | ...
-| | Given Add worker threads and rxqueues to all DUTs | ${phy_cores} | ${rxq}
-| | And Add PCI devices to all DUTs
-| | And Set Max Rate And Jumbo And Handle Multi Seg
+| | Given Set Max Rate And Jumbo
+| | And Add worker threads to all DUTs | ${phy_cores} | ${rxq}
+| | And Pre-initialize layer driver | ${nic_driver}
| | And Apply startup configuration on all VPP DUTs
-| | When Initialize layer driver | vfio-pci
+| | When Initialize layer driver | ${nic_driver}
+| | And Initialize layer interface
| | And Initialize L2 xconnect with Vhost-User | nf_nodes=${nf_nodes}
| | And Configure chains of NFs connected via vhost-user
| | ... | nf_chains=${nf_chains} | nf_nodes=${nf_nodes} | jumbo=${jumbo}
diff --git a/tests/vpp/perf/vm_vhost/10ge2p1x710-ethip4-ip4base-eth-2vhostvr1024-1vm-ndrpdr.robot b/tests/vpp/perf/vm_vhost/10ge2p1x710-ethip4-ip4base-eth-2vhostvr1024-1vm-ndrpdr.robot
index f12fe17547..3ee2b60ffb 100644
--- a/tests/vpp/perf/vm_vhost/10ge2p1x710-ethip4-ip4base-eth-2vhostvr1024-1vm-ndrpdr.robot
+++ b/tests/vpp/perf/vm_vhost/10ge2p1x710-ethip4-ip4base-eth-2vhostvr1024-1vm-ndrpdr.robot
@@ -16,7 +16,7 @@
| ...
| Force Tags | 3_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | NDRPDR
| ... | NIC_Intel-X710 | ETH | IP4FWD | BASE | VHOST | 1VM | VHOST_1024
-| ... | NF_TESTPMD
+| ... | NF_TESTPMD | DRV_VFIO_PCI
| ...
| Suite Setup | Setup suite single link | performance
| Suite Teardown | Tear down suite | performance
@@ -49,9 +49,10 @@
*** Variables ***
| @{plugins_to_enable}= | dpdk_plugin.so
-| ${osi_layer}= | L3
+| ${crypto_type}= | ${None}
| ${nic_name}= | Intel-X710
| ${nic_driver}= | vfio-pci
+| ${osi_layer}= | L3
| ${overhead}= | ${0}
| ${nf_dtcr}= | ${1}
| ${nf_dtc}= | ${1}
@@ -77,11 +78,12 @@
| | ...
| | Set Test Variable | \${frame_size}
| | ...
-| | Given Add worker threads and rxqueues to all DUTs | ${phy_cores} | ${rxq}
-| | And Add PCI devices to all DUTs
-| | And Set Max Rate And Jumbo And Handle Multi Seg
+| | Given Set Max Rate And Jumbo
+| | And Add worker threads to all DUTs | ${phy_cores} | ${rxq}
+| | And Pre-initialize layer driver | ${nic_driver}
| | And Apply startup configuration on all VPP DUTs
-| | When Initialize layer driver | vfio-pci
+| | When Initialize layer driver | ${nic_driver}
+| | And Initialize layer interface
| | And Initialize IPv4 forwarding with vhost in 3-node circular topology
| | ... | nf_nodes=${nf_nodes} | testpmd_mac=${TRUE}
| | And Configure chains of NFs connected via vhost-user
diff --git a/tests/vpp/perf/vm_vhost/10ge2p1x710-ethip4-ip4base-eth-2vhostvr1024-1vm-vppip4-ndrpdr.robot b/tests/vpp/perf/vm_vhost/10ge2p1x710-ethip4-ip4base-eth-2vhostvr1024-1vm-vppip4-ndrpdr.robot
index 20f2beeb65..6d2ea070bf 100644
--- a/tests/vpp/perf/vm_vhost/10ge2p1x710-ethip4-ip4base-eth-2vhostvr1024-1vm-vppip4-ndrpdr.robot
+++ b/tests/vpp/perf/vm_vhost/10ge2p1x710-ethip4-ip4base-eth-2vhostvr1024-1vm-vppip4-ndrpdr.robot
@@ -16,7 +16,7 @@
| ...
| Force Tags | 3_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | NDRPDR
| ... | NIC_Intel-X710 | ETH | IP4FWD | BASE | VHOST | 1VM | VHOST_1024
-| ... | NF_VPPIP4
+| ... | NF_VPPIP4 | DRV_VFIO_PCI
| ...
| Suite Setup | Setup suite single link | performance
| Suite Teardown | Tear down suite | performance
@@ -49,9 +49,10 @@
*** Variables ***
| @{plugins_to_enable}= | dpdk_plugin.so
-| ${osi_layer}= | L3
+| ${crypto_type}= | ${None}
| ${nic_name}= | Intel-X710
| ${nic_driver}= | vfio-pci
+| ${osi_layer}= | L3
| ${overhead}= | ${0}
| ${nf_dtcr}= | ${1}
| ${nf_dtc}= | ${1}
@@ -77,11 +78,12 @@
| | ...
| | Set Test Variable | \${frame_size}
| | ...
-| | Given Add worker threads and rxqueues to all DUTs | ${phy_cores} | ${rxq}
-| | And Add PCI devices to all DUTs
-| | And Set Max Rate And Jumbo And Handle Multi Seg
+| | Given Set Max Rate And Jumbo
+| | And Add worker threads to all DUTs | ${phy_cores} | ${rxq}
+| | And Pre-initialize layer driver | ${nic_driver}
| | And Apply startup configuration on all VPP DUTs
-| | When Initialize layer driver | vfio-pci
+| | When Initialize layer driver | ${nic_driver}
+| | And Initialize layer interface
| | And Initialize IPv4 forwarding with vhost in 3-node circular topology
| | ... | nf_nodes=${nf_nodes}
| | And Configure chains of NFs connected via vhost-user
diff --git a/tests/vpp/perf/vm_vhost/10ge2p1x710-ethip4vxlan-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot b/tests/vpp/perf/vm_vhost/10ge2p1x710-ethip4vxlan-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot
index e5f7bf242c..55552ceca2 100644
--- a/tests/vpp/perf/vm_vhost/10ge2p1x710-ethip4vxlan-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot
+++ b/tests/vpp/perf/vm_vhost/10ge2p1x710-ethip4vxlan-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot
@@ -16,7 +16,7 @@
| ...
| Force Tags | 3_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | NDRPDR
| ... | NIC_Intel-X710 | L2BDMACLRN | ENCAP | VXLAN | L2OVRLAY | IP4UNRLAY
-| ... | VHOST | 1VM | VHOST_1024 | NF_TESTPMD
+| ... | VHOST | 1VM | VHOST_1024 | NF_TESTPMD | DRV_VFIO_PCI
| ...
| Suite Setup | Setup suite single link | performance
| Suite Teardown | Tear down suite | performance
@@ -51,9 +51,10 @@
*** Variables ***
| @{plugins_to_enable}= | dpdk_plugin.so
-| ${osi_layer}= | L2
+| ${crypto_type}= | ${None}
| ${nic_name}= | Intel-X710
| ${nic_driver}= | vfio-pci
+| ${osi_layer}= | L2
| ${overhead}= | ${50}
| ${bd_id1}= | 1
| ${bd_id2}= | 2
@@ -81,11 +82,12 @@
| | ...
| | Set Test Variable | \${frame_size}
| | ...
-| | Given Add worker threads and rxqueues to all DUTs | ${phy_cores} | ${rxq}
-| | And Add PCI devices to all DUTs
-| | And Set Max Rate And Jumbo And Handle Multi Seg
+| | Given Set Max Rate And Jumbo
+| | And Add worker threads to all DUTs | ${phy_cores} | ${rxq}
+| | And Pre-initialize layer driver | ${nic_driver}
| | And Apply startup configuration on all VPP DUTs
-| | When Initialize layer driver | vfio-pci
+| | When Initialize layer driver | ${nic_driver}
+| | And Initialize layer interface
| | And Initialize L2 bridge domains with Vhost-User and VXLANoIPv4 in 3-node circular topology
| | ... | ${bd_id1} | ${bd_id2}
| | And Configure chains of NFs connected via vhost-user
diff --git a/tests/vpp/perf/vm_vhost/10ge2p1x710-ethip4vxlan-l2bdbasemaclrn-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot b/tests/vpp/perf/vm_vhost/10ge2p1x710-ethip4vxlan-l2bdbasemaclrn-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot
index e70db2e210..ab8f42e43e 100644
--- a/tests/vpp/perf/vm_vhost/10ge2p1x710-ethip4vxlan-l2bdbasemaclrn-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot
+++ b/tests/vpp/perf/vm_vhost/10ge2p1x710-ethip4vxlan-l2bdbasemaclrn-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot
@@ -16,7 +16,7 @@
| ...
| Force Tags | 3_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | NDRPDR
| ... | NIC_Intel-X710 | L2BDMACLRN | ENCAP | VXLAN | L2OVRLAY | IP4UNRLAY
-| ... | VHOST | 1VM | VHOST_1024 | NF_VPPL2XC
+| ... | VHOST | 1VM | VHOST_1024 | NF_VPPL2XC | DRV_VFIO_PCI
| ...
| Suite Setup | Setup suite single link | performance
| Suite Teardown | Tear down suite | performance
@@ -51,9 +51,10 @@
*** Variables ***
| @{plugins_to_enable}= | dpdk_plugin.so
-| ${osi_layer}= | L2
+| ${crypto_type}= | ${None}
| ${nic_name}= | Intel-X710
| ${nic_driver}= | vfio-pci
+| ${osi_layer}= | L2
| ${overhead}= | ${50}
| ${bd_id1}= | 1
| ${bd_id2}= | 2
@@ -81,11 +82,12 @@
| | ...
| | Set Test Variable | \${frame_size}
| | ...
-| | Given Add worker threads and rxqueues to all DUTs | ${phy_cores} | ${rxq}
-| | And Add PCI devices to all DUTs
-| | And Set Max Rate And Jumbo And Handle Multi Seg
+| | Given Set Max Rate And Jumbo
+| | And Add worker threads to all DUTs | ${phy_cores} | ${rxq}
+| | And Pre-initialize layer driver | ${nic_driver}
| | And Apply startup configuration on all VPP DUTs
-| | When Initialize layer driver | vfio-pci
+| | When Initialize layer driver | ${nic_driver}
+| | And Initialize layer interface
| | And Initialize L2 bridge domains with Vhost-User and VXLANoIPv4 in 3-node circular topology
| | ... | ${bd_id1} | ${bd_id2}
| | And Configure chains of NFs connected via vhost-user
diff --git a/tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot b/tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot
index c7d5410913..d44ae9c909 100644
--- a/tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot
+++ b/tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot
@@ -16,7 +16,7 @@
| ...
| Force Tags | 2_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | NDRPDR
| ... | NIC_Intel-X710 | DOT1Q | L2BDMACLRN | BASE | VHOST | 1VM
-| ... | VHOST_1024 | NF_TESTPMD
+| ... | VHOST_1024 | NF_TESTPMD | DRV_VFIO_PCI
| ...
| Suite Setup | Setup suite single link | performance
| Suite Teardown | Tear down suite | performance
@@ -51,9 +51,10 @@
*** Variables ***
| @{plugins_to_enable}= | dpdk_plugin.so
-| ${osi_layer}= | L2
+| ${crypto_type}= | ${None}
| ${nic_name}= | Intel-X710
| ${nic_driver}= | vfio-pci
+| ${osi_layer}= | L2
| ${overhead}= | ${4}
| ${subid}= | 10
| ${tag_rewrite}= | pop-1
@@ -83,11 +84,12 @@
| | ...
| | Set Test Variable | \${frame_size}
| | ...
-| | Given Add worker threads and rxqueues to all DUTs | ${phy_cores} | ${rxq}
-| | And Add PCI devices to all DUTs
-| | And Set Max Rate And Jumbo And Handle Multi Seg
+| | Given Set Max Rate And Jumbo
+| | And Add worker threads to all DUTs | ${phy_cores} | ${rxq}
+| | And Pre-initialize layer driver | ${nic_driver}
| | And Apply startup configuration on all VPP DUTs
-| | When Initialize layer driver | vfio-pci
+| | When Initialize layer driver | ${nic_driver}
+| | And Initialize layer interface
| | And Initialize L2 bridge domains with Vhost-User and VLAN in circular topology
| | ... | ${bd_id1} | ${bd_id2} | ${subid} | ${tag_rewrite}
| | And Configure chains of NFs connected via vhost-user
diff --git a/tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot b/tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot
index 2a5c08297c..6a8d3466a8 100644
--- a/tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot
+++ b/tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-dot1q-l2bdbasemaclrn-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot
@@ -16,7 +16,7 @@
| ...
| Force Tags | 2_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | NDRPDR
| ... | NIC_Intel-X710 | DOT1Q | L2BDMACLRN | BASE | VHOST | 1VM
-| ... | VHOST_1024 | NF_VPPL2XC
+| ... | VHOST_1024 | NF_VPPL2XC | DRV_VFIO_PCI
| ...
| Suite Setup | Setup suite single link | performance
| Suite Teardown | Tear down suite | performance
@@ -51,9 +51,10 @@
*** Variables ***
| @{plugins_to_enable}= | dpdk_plugin.so
-| ${osi_layer}= | L2
+| ${crypto_type}= | ${None}
| ${nic_name}= | Intel-X710
| ${nic_driver}= | vfio-pci
+| ${osi_layer}= | L2
| ${overhead}= | ${4}
| ${subid}= | 10
| ${tag_rewrite}= | pop-1
@@ -83,11 +84,12 @@
| | ...
| | Set Test Variable | \${frame_size}
| | ...
-| | Given Add worker threads and rxqueues to all DUTs | ${phy_cores} | ${rxq}
-| | And Add PCI devices to all DUTs
-| | And Set Max Rate And Jumbo And Handle Multi Seg
+| | Given Set Max Rate And Jumbo
+| | And Add worker threads to all DUTs | ${phy_cores} | ${rxq}
+| | And Pre-initialize layer driver | ${nic_driver}
| | And Apply startup configuration on all VPP DUTs
-| | When Initialize layer driver | vfio-pci
+| | When Initialize layer driver | ${nic_driver}
+| | And Initialize layer interface
| | And Initialize L2 bridge domains with Vhost-User and VLAN in circular topology
| | ... | ${bd_id1} | ${bd_id2} | ${subid} | ${tag_rewrite}
| | And Configure chains of NFs connected via vhost-user
diff --git a/tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-eth-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot b/tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-eth-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot
index 0b9c4422c7..9bfd07ea33 100644
--- a/tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-eth-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot
+++ b/tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-eth-l2bdbasemaclrn-eth-2vhostvr1024-1vm-ndrpdr.robot
@@ -16,7 +16,7 @@
| ...
| Force Tags | 2_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | NDRPDR
| ... | NIC_Intel-X710 | ETH | L2BDMACLRN | BASE | VHOST | 1VM | VHOST_1024
-| ... | NF_TESTPMD
+| ... | NF_TESTPMD | DRV_VFIO_PCI
| ...
| Suite Setup | Setup suite single link | performance
| Suite Teardown | Tear down suite | performance
@@ -50,9 +50,10 @@
*** Variables ***
| @{plugins_to_enable}= | dpdk_plugin.so
-| ${osi_layer}= | L2
+| ${crypto_type}= | ${None}
| ${nic_name}= | Intel-X710
| ${nic_driver}= | vfio-pci
+| ${osi_layer}= | L2
| ${overhead}= | ${0}
| ${nf_dtcr}= | ${1}
| ${nf_dtc}= | ${1}
@@ -78,11 +79,11 @@
| | ...
| | Set Test Variable | \${frame_size}
| | ...
-| | Given Add worker threads and rxqueues to all DUTs | ${phy_cores} | ${rxq}
-| | And Add PCI devices to all DUTs
-| | And Set Max Rate And Jumbo And Handle Multi Seg
+| | Given Set Max Rate And Jumbo
+| | And Add worker threads to all DUTs | ${phy_cores} | ${rxq}
+| | And Pre-initialize layer driver | ${nic_driver}
| | And Apply startup configuration on all VPP DUTs
-| | When Initialize layer driver | vfio-pci
+| | When Initialize layer driver | ${nic_driver}
| | And Initialize layer interface
| | ... | count=${nf_chains}
| | And Initialize L2 bridge domains for multiple chains with Vhost-User
diff --git a/tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-eth-l2bdbasemaclrn-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot b/tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-eth-l2bdbasemaclrn-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot
index 31f29c94dc..45fbfe8233 100644
--- a/tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-eth-l2bdbasemaclrn-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot
+++ b/tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-eth-l2bdbasemaclrn-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot
@@ -16,7 +16,7 @@
| ...
| Force Tags | 2_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | NDRPDR
| ... | NIC_Intel-X710 | ETH | L2BDMACLRN | BASE | VHOST | 1VM | VHOST_1024
-| ... | NF_VPPL2XC
+| ... | NF_VPPL2XC | DRV_VFIO_PCI
| ...
| Suite Setup | Setup suite single link | performance
| Suite Teardown | Tear down suite | performance
@@ -50,9 +50,10 @@
*** Variables ***
| @{plugins_to_enable}= | dpdk_plugin.so
-| ${osi_layer}= | L2
+| ${crypto_type}= | ${None}
| ${nic_name}= | Intel-X710
| ${nic_driver}= | vfio-pci
+| ${osi_layer}= | L2
| ${overhead}= | ${0}
| ${nf_dtcr}= | ${1}
| ${nf_dtc}= | ${1}
@@ -78,11 +79,11 @@
| | ...
| | Set Test Variable | \${frame_size}
| | ...
-| | Given Add worker threads and rxqueues to all DUTs | ${phy_cores} | ${rxq}
-| | And Add PCI devices to all DUTs
-| | And Set Max Rate And Jumbo And Handle Multi Seg
+| | Given Set Max Rate And Jumbo
+| | And Add worker threads to all DUTs | ${phy_cores} | ${rxq}
+| | And Pre-initialize layer driver | ${nic_driver}
| | And Apply startup configuration on all VPP DUTs
-| | When Initialize layer driver | vfio-pci
+| | When Initialize layer driver | ${nic_driver}
| | And Initialize layer interface
| | ... | count=${nf_chains}
| | And Initialize L2 bridge domains for multiple chains with Vhost-User
diff --git a/tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-eth-l2xcbase-eth-2vhostvr1024-1vm-ndrpdr.robot b/tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-eth-l2xcbase-eth-2vhostvr1024-1vm-ndrpdr.robot
index 92a05c51ca..559acc2467 100644
--- a/tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-eth-l2xcbase-eth-2vhostvr1024-1vm-ndrpdr.robot
+++ b/tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-eth-l2xcbase-eth-2vhostvr1024-1vm-ndrpdr.robot
@@ -16,7 +16,7 @@
| ...
| Force Tags | 2_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | NDRPDR
| ... | NIC_Intel-X710 | ETH | L2XCFWD | BASE | VHOST | 1VM | VHOST_1024
-| ... | NF_TESTPMD
+| ... | NF_TESTPMD | DRV_VFIO_PCI
| ...
| Suite Setup | Setup suite single link | performance
| Suite Teardown | Tear down suite | performance
@@ -49,9 +49,10 @@
*** Variables ***
| @{plugins_to_enable}= | dpdk_plugin.so
-| ${osi_layer}= | L2
+| ${crypto_type}= | ${None}
| ${nic_name}= | Intel-X710
| ${nic_driver}= | vfio-pci
+| ${osi_layer}= | L2
| ${overhead}= | ${0}
| ${nf_dtcr}= | ${1}
| ${nf_dtc}= | ${1}
@@ -77,11 +78,12 @@
| | ...
| | Set Test Variable | \${frame_size}
| | ...
-| | Given Add worker threads and rxqueues to all DUTs | ${phy_cores} | ${rxq}
-| | And Add PCI devices to all DUTs
-| | And Set Max Rate And Jumbo And Handle Multi Seg
+| | Given Set Max Rate And Jumbo
+| | And Add worker threads to all DUTs | ${phy_cores} | ${rxq}
+| | And Pre-initialize layer driver | ${nic_driver}
| | And Apply startup configuration on all VPP DUTs
-| | When Initialize layer driver | vfio-pci
+| | When Initialize layer driver | ${nic_driver}
+| | And Initialize layer interface
| | And Initialize L2 xconnect with Vhost-User | nf_nodes=${nf_nodes}
| | And Configure chains of NFs connected via vhost-user
| | ... | nf_chains=${nf_chains} | nf_nodes=${nf_nodes} | jumbo=${jumbo}
diff --git a/tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-eth-l2xcbase-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot b/tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-eth-l2xcbase-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot
index 1d9e309dda..4e26a4886b 100644
--- a/tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-eth-l2xcbase-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot
+++ b/tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-eth-l2xcbase-eth-2vhostvr1024-1vm-vppl2xc-ndrpdr.robot
@@ -16,7 +16,7 @@
| ...
| Force Tags | 2_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | NDRPDR
| ... | NIC_Intel-X710 | ETH | L2XCFWD | BASE | VHOST | 1VM | VHOST_1024
-| ... | NF_VPPL2XC
+| ... | NF_VPPL2XC | DRV_VFIO_PCI
| ...
| Suite Setup | Setup suite single link | performance
| Suite Teardown | Tear down suite | performance
@@ -49,9 +49,10 @@
*** Variables ***
| @{plugins_to_enable}= | dpdk_plugin.so
-| ${osi_layer}= | L2
+| ${crypto_type}= | ${None}
| ${nic_name}= | Intel-X710
| ${nic_driver}= | vfio-pci
+| ${osi_layer}= | L2
| ${overhead}= | ${0}
| ${nf_dtcr}= | ${1}
| ${nf_dtc}= | ${1}
@@ -77,11 +78,12 @@
| | ...
| | Set Test Variable | \${frame_size}
| | ...
-| | Given Add worker threads and rxqueues to all DUTs | ${phy_cores} | ${rxq}
-| | And Add PCI devices to all DUTs
-| | And Set Max Rate And Jumbo And Handle Multi Seg
+| | Given Set Max Rate And Jumbo
+| | And Add worker threads to all DUTs | ${phy_cores} | ${rxq}
+| | And Pre-initialize layer driver | ${nic_driver}
| | And Apply startup configuration on all VPP DUTs
-| | When Initialize layer driver | vfio-pci
+| | When Initialize layer driver | ${nic_driver}
+| | And Initialize layer interface
| | And Initialize L2 xconnect with Vhost-User | nf_nodes=${nf_nodes}
| | And Configure chains of NFs connected via vhost-user
| | ... | nf_chains=${nf_chains} | nf_nodes=${nf_nodes} | jumbo=${jumbo}
diff --git a/tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-ethip4-ip4base-eth-2vhostvr1024-1vm-ndrpdr.robot b/tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-ethip4-ip4base-eth-2vhostvr1024-1vm-ndrpdr.robot
index 1678b17b10..ae1b86ec05 100644
--- a/tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-ethip4-ip4base-eth-2vhostvr1024-1vm-ndrpdr.robot
+++ b/tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-ethip4-ip4base-eth-2vhostvr1024-1vm-ndrpdr.robot
@@ -16,7 +16,7 @@
| ...
| Force Tags | 2_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | NDRPDR
| ... | NIC_Intel-X710 | ETH | IP4FWD | BASE | VHOST | 1VM | VHOST_1024
-| ... | NF_TESTPMD
+| ... | NF_TESTPMD | DRV_VFIO_PCI
| ...
| Suite Setup | Setup suite single link | performance
| Suite Teardown | Tear down suite | performance
@@ -49,9 +49,10 @@
*** Variables ***
| @{plugins_to_enable}= | dpdk_plugin.so
-| ${osi_layer}= | L3
+| ${crypto_type}= | ${None}
| ${nic_name}= | Intel-X710
| ${nic_driver}= | vfio-pci
+| ${osi_layer}= | L3
| ${overhead}= | ${0}
| ${nf_dtcr}= | ${1}
| ${nf_dtc}= | ${1}
@@ -77,11 +78,12 @@
| | ...
| | Set Test Variable | \${frame_size}
| | ...
-| | Given Add worker threads and rxqueues to all DUTs | ${phy_cores} | ${rxq}
-| | And Add PCI devices to all DUTs
-| | And Set Max Rate And Jumbo And Handle Multi Seg
+| | Given Set Max Rate And Jumbo
+| | And Add worker threads to all DUTs | ${phy_cores} | ${rxq}
+| | And Pre-initialize layer driver | ${nic_driver}
| | And Apply startup configuration on all VPP DUTs
-| | When Initialize layer driver | vfio-pci
+| | When Initialize layer driver | ${nic_driver}
+| | And Initialize layer interface
| | And Initialize IPv4 forwarding with vhost in 2-node circular topology
| | ... | nf_nodes=${nf_nodes} | testpmd_mac=${TRUE}
| | And Configure chains of NFs connected via vhost-user
diff --git a/tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-ethip4-ip4base-eth-2vhostvr1024-1vm-vppip4-ndrpdr.robot b/tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-ethip4-ip4base-eth-2vhostvr1024-1vm-vppip4-ndrpdr.robot
index 8e9f63389e..6cb2f016be 100644
--- a/tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-ethip4-ip4base-eth-2vhostvr1024-1vm-vppip4-ndrpdr.robot
+++ b/tests/vpp/perf/vm_vhost/2n1l-10ge2p1x710-ethip4-ip4base-eth-2vhostvr1024-1vm-vppip4-ndrpdr.robot
@@ -16,7 +16,7 @@
| ...
| Force Tags | 2_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | NDRPDR
| ... | NIC_Intel-X710 | ETH | IP4FWD | BASE | VHOST | 1VM | VHOST_1024
-| ... | NF_VPPIP4
+| ... | NF_VPPIP4 | DRV_VFIO_PCI
| ...
| Suite Setup | Setup suite single link | performance
| Suite Teardown | Tear down suite | performance
@@ -49,9 +49,10 @@
*** Variables ***
| @{plugins_to_enable}= | dpdk_plugin.so
-| ${osi_layer}= | L3
+| ${crypto_type}= | ${None}
| ${nic_name}= | Intel-X710
| ${nic_driver}= | vfio-pci
+| ${osi_layer}= | L3
| ${overhead}= | ${0}
| ${nf_dtcr}= | ${1}
| ${nf_dtc}= | ${1}
@@ -77,11 +78,12 @@
| | ...
| | Set Test Variable | \${frame_size}
| | ...
-| | Given Add worker threads and rxqueues to all DUTs | ${phy_cores} | ${rxq}
-| | And Add PCI devices to all DUTs
-| | And Set Max Rate And Jumbo And Handle Multi Seg
+| | Given Set Max Rate And Jumbo
+| | And Add worker threads to all DUTs | ${phy_cores} | ${rxq}
+| | And Pre-initialize layer driver | ${nic_driver}
| | And Apply startup configuration on all VPP DUTs
-| | When Initialize layer driver | vfio-pci
+| | When Initialize layer driver | ${nic_driver}
+| | And Initialize layer interface
| | And Initialize IPv4 forwarding with vhost in 2-node circular topology
| | ... | nf_nodes=${nf_nodes}
| | And Configure chains of NFs connected via vhost-user