diff options
Diffstat (limited to 'topologies/available')
-rw-r--r-- | topologies/available/2n_hw_testbed1.yaml.example | 8 | ||||
-rw-r--r-- | topologies/available/lf_2n_clx_testbed27.yaml | 203 | ||||
-rw-r--r-- | topologies/available/lf_2n_clx_testbed28.yaml | 203 | ||||
-rw-r--r-- | topologies/available/lf_2n_clx_testbed29.yaml | 187 | ||||
-rw-r--r-- | topologies/available/lf_2n_tx2_testbed34.yaml | 64 | ||||
-rw-r--r-- | topologies/available/lf_3n_tsh_testbed33.yaml | 97 |
6 files changed, 4 insertions, 758 deletions
diff --git a/topologies/available/2n_hw_testbed1.yaml.example b/topologies/available/2n_hw_testbed1.yaml.example index 4155f6eb0a..eb3acae3ec 100644 --- a/topologies/available/2n_hw_testbed1.yaml.example +++ b/topologies/available/2n_hw_testbed1.yaml.example @@ -34,12 +34,12 @@ nodes: mac_address: "08:00:27:35:59:04" pci_address: "0000:00:08.0" link: link1 - model: Intel-X553 + model: Intel-X710 port5: mac_address: "08:00:27:46:2b:4c" pci_address: "0000:00:09.0" link: link2 - model: Intel-X553 + model: Intel-X710 DUT1: type: DUT host: 10.0.0.1 @@ -53,9 +53,9 @@ nodes: mac_address: "08:00:27:ae:29:2b" pci_address: "0000:00:08.0" link: link1 - model: Intel-X553 + model: Intel-X710 port3: mac_address: "08:00:27:f3:be:f0" pci_address: "0000:00:09.0" link: link2 - model: Intel-X553
\ No newline at end of file + model: Intel-X710
\ No newline at end of file diff --git a/topologies/available/lf_2n_clx_testbed27.yaml b/topologies/available/lf_2n_clx_testbed27.yaml deleted file mode 100644 index 63e16d90e2..0000000000 --- a/topologies/available/lf_2n_clx_testbed27.yaml +++ /dev/null @@ -1,203 +0,0 @@ ---- -metadata: - version: 0.1 - schema: - - resources/topology_schemas/2_node_topology.sch.yaml - - resources/topology_schemas/topology.sch.yaml - tags: [hw, 2-node] - -nodes: - TG: - type: TG - subtype: TREX - host: "10.32.8.19" - arch: x86_64 - port: 22 - username: testuser - password: Csit1234 - interfaces: - port1: - # s34-t27-tg1-c2/p1 - 10GE port1 on Intel NIC x710 4p10GE. - mac_address: "3c:fd:fe:ca:e9:88" - pci_address: "0000:18:00.0" - ip4_address: "172.16.10.2" - driver: i40e - link: disabled1 - model: Intel-X710 - port2: - # s34-t27-tg1-c2/p2 - 10GE port2 on Intel NIC x710 4p10GE. - mac_address: "3c:fd:fe:ca:e9:89" - pci_address: "0000:18:00.1" - ip4_address: "172.16.20.2" - driver: i40e - link: disabled2 - model: Intel-X710 - port3: - # s34-t27-tg1-c2/p3 - 10GE port3 on Intel NIC x710 4p10GE. - mac_address: "3c:fd:fe:ca:e9:8a" - pci_address: "0000:18:00.2" - ip4_address: "172.16.30.2" - driver: i40e - link: link3 - model: Intel-X710 - port4: - # s34-t27-tg1-c2/p4 - 10GE port4 on Intel NIC x710 4p10GE. - mac_address: "3c:fd:fe:ca:e9:8b" - pci_address: "0000:18:00.3" - ip4_address: "172.16.40.2" - driver: i40e - link: link4 - model: Intel-X710 - port5: - # s34-t27-tg1-c4/p1 - 25GE port1 on Intel NIC xxv710 2p25GE. - mac_address: "3c:fd:fe:dd:d4:28" - pci_address: "0000:3b:00.0" - ip4_address: "172.16.50.2" - driver: i40e - link: link5 - model: Intel-XXV710 - port6: - # s34-t27-tg1-c4/p2 - 25GE port2 on Intel NIC xxv710 2p25GE. - mac_address: "3c:fd:fe:dd:d4:29" - pci_address: "0000:3b:00.1" - ip4_address: "172.16.60.2" - driver: i40e - link: link6 - model: Intel-XXV710 - port7: - # s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. - mac_address: "ec:0d:9a:8c:c6:a6" - pci_address: "0000:5e:00.0" - ip4_address: "172.16.70.2" - driver: mlx5_core - link: link7 - model: Mellanox-CX556A - port8: - # s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. - mac_address: "ec:0d:9a:8c:c6:a7" - pci_address: "0000:5e:00.1" - ip4_address: "172.16.80.2" - driver: mlx5_core - link: link8 - model: Mellanox-CX556A - port9: - # s34-t27-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE. - mac_address: "10:70:fd:15:60:54" - pci_address: "0000:86:00.0" - ip4_address: "172.16.90.2" - driver: mlx5_core - link: link9 - model: Mellanox-CX556A - port10: - # s34-t27-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE. - mac_address: "10:70:fd:15:60:55" - pci_address: "0000:86:00.1" - ip4_address: "172.16.100.2" - driver: mlx5_core - link: link10 - model: Mellanox-CX556A - port11: - # s34-t27-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE. - mac_address: "0c:42:a1:0b:92:1a" - pci_address: "0000:af:00.0" - ip4_address: "172.16.110.2" - driver: mlx5_core - link: link11 - model: Mellanox-CX556A - port12: - # s34-t27-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE. - mac_address: "0c:42:a1:0b:92:1b" - pci_address: "0000:af:00.1" - ip4_address: "172.16.120.2" - driver: mlx5_core - link: link11 - model: Mellanox-CX556A - DUT1: - type: DUT - host: "10.32.8.18" - arch: x86_64 - port: 22 - username: testuser - password: Csit1234 - uio_driver: vfio-pci - interfaces: - port1: - # s33-t27-sut1-c2/p1 - 10GE port1 on Intel NIC x710 4p10GE. - mac_address: "3c:fd:fe:ca:e9:98" - pci_address: "0000:18:00.0" - ip4_address: "172.16.10.1" - driver: i40e - link: disabled3 - model: Intel-X710 - port2: - # s33-t27-sut1-c2/p2 - 10GE port2 on Intel NIC x710 4p10GE. - mac_address: "3c:fd:fe:ca:e9:99" - pci_address: "0000:18:00.1" - ip4_address: "172.16.20.1" - driver: i40e - link: disabled4 - model: Intel-X710 - port3: - # s33-t27-sut1-c2/p3 - 10GE port3 on Intel NIC x710 4p10GE. - mac_address: "3c:fd:fe:ca:e9:9a" - pci_address: "0000:18:00.2" - ip4_address: "172.16.30.1" - driver: i40e - link: link3 - model: Intel-X710 - port4: - # s33-t27-sut1-c2/p4 - 10GE port4 on Intel NIC x710 4p10GE. - mac_address: "3c:fd:fe:ca:e9:9b" - pci_address: "0000:18:00.3" - ip4_address: "172.16.40.1" - driver: i40e - link: link4 - model: Intel-X710 - port5: - # s33-t27-sut1-c2/p1 - 25GE port1 on Intel NIC xxv710 2p25GE. - mac_address: "3c:fd:fe:cf:69:e8" - pci_address: "0000:3b:00.0" - ip4_address: "172.16.50.1" - driver: i40e - link: link5 - model: Intel-XXV710 - port6: - # s33-t27-sut1-c2/p2 - 25GE port2 on Intel NIC xxv710 2p25GE. - mac_address: "3c:fd:fe:cf:69:e9" - pci_address: "0000:3b:00.1" - ip4_address: "172.16.60.1" - driver: i40e - link: link6 - model: Intel-XXV710 - port7: - # s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. - mac_address: "ec:0d:9a:8c:c6:96" - pci_address: "0000:5e:00.0" - ip4_address: "172.16.70.1" - driver: mlx5_core - link: link7 - model: Mellanox-CX556A - port8: - # s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. - mac_address: "ec:0d:9a:8c:c6:97" - pci_address: "0000:5e:00.1" - ip4_address: "172.16.80.1" - driver: mlx5_core - link: link8 - model: Mellanox-CX556A - port9: - # s33-t27-sut1-c6/p1 - 100GE-port1 Intel E810-CQDA2 2p100GE. - mac_address: "b4:96:91:a2:fb:d0" - pci_address: "0000:86:00.0" - ip4_address: "172.16.90.1" - driver: ice - link: link9 - model: Intel-E810CQ - port10: - # s33-t27-sut1-c6/p2 - 100GE-port1 Intel E810-CQDA2 2p100GE. - mac_address: "b4:96:91:a2:fb:d1" - pci_address: "0000:86:00.1" - ip4_address: "172.16.100.1" - driver: ice - link: link10 - model: Intel-E810CQ
\ No newline at end of file diff --git a/topologies/available/lf_2n_clx_testbed28.yaml b/topologies/available/lf_2n_clx_testbed28.yaml deleted file mode 100644 index 771cb20c52..0000000000 --- a/topologies/available/lf_2n_clx_testbed28.yaml +++ /dev/null @@ -1,203 +0,0 @@ ---- -metadata: - version: 0.1 - schema: - - resources/topology_schemas/2_node_topology.sch.yaml - - resources/topology_schemas/topology.sch.yaml - tags: [hw, 2-node] - -nodes: - TG: - type: TG - subtype: TREX - host: "10.32.8.21" - arch: x86_64 - port: 22 - username: testuser - password: Csit1234 - interfaces: - port1: - # s36-t28-tg1-c2/p1 - 10GE port1 on Intel NIC x710 4p10GE. - mac_address: "3c:fd:fe:ca:e8:28" - pci_address: "0000:18:00.0" - ip4_address: "172.16.10.2" - driver: i40e - link: disabled1 - model: Intel-X710 - port2: - # s36-t28-tg1-c2/p2 - 10GE port2 on Intel NIC x710 4p10GE. - mac_address: "3c:fd:fe:ca:e8:29" - pci_address: "0000:18:00.1" - ip4_address: "172.16.20.2" - driver: i40e - link: disabled2 - model: Intel-X710 - port3: - # s36-t28-tg1-c2/p3 - 10GE port3 on Intel NIC x710 4p10GE. - mac_address: "3c:fd:fe:ca:e8:2a" - pci_address: "0000:18:00.2" - ip4_address: "172.16.30.2" - driver: i40e - link: link3 - model: Intel-X710 - port4: - # s36-t28-tg1-c2/p4 - 10GE port4 on Intel NIC x710 4p10GE. - mac_address: "3c:fd:fe:ca:e8:2b" - pci_address: "0000:18:00.3" - ip4_address: "172.16.40.2" - driver: i40e - link: link4 - model: Intel-X710 - port5: - # s36-t28-tg1-c4/p1 - 25GE port1 on Intel NIC xxv710 2p25GE. - mac_address: "3c:fd:fe:cf:69:ec" - pci_address: "0000:3b:00.0" - ip4_address: "172.16.50.2" - driver: i40e - link: link5 - model: Intel-XXV710 - port6: - # s36-t28-tg1-c4/p2 - 25GE port2 on Intel NIC xxv710 2p25GE. - mac_address: "3c:fd:fe:cf:69:ed" - pci_address: "0000:3b:00.1" - ip4_address: "172.16.60.2" - driver: i40e - link: link6 - model: Intel-XXV710 - port7: - # s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. - mac_address: "ec:0d:9a:8c:c7:f6" - pci_address: "0000:5e:00.0" - ip4_address: "172.16.70.2" - driver: mlx5_core - link: link7 - model: Mellanox-CX556A - port8: - # s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. - mac_address: "ec:0d:9a:8c:c7:f7" - pci_address: "0000:5e:00.1" - ip4_address: "172.16.80.2" - driver: mlx5_core - link: link8 - model: Mellanox-CX556A - port9: - # s36-t28-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE. - mac_address: "10:70:fd:15:5f:b4" - pci_address: "0000:86:00.0" - ip4_address: "172.16.90.2" - driver: mlx5_core - link: link9 - model: Mellanox-CX556A - port10: - # s36-t28-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE. - mac_address: "10:70:fd:15:5f:b5" - pci_address: "0000:86:00.1" - ip4_address: "172.16.100.2" - driver: mlx5_core - link: link10 - model: Mellanox-CX556A - port11: - # s36-t28-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE. - mac_address: "0c:42:a1:0b:99:8a" - pci_address: "0000:af:00.0" - ip4_address: "172.16.110.2" - driver: mlx5_core - link: link11 - model: Mellanox-CX556A - port12: - # s36-t28-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE. - mac_address: "0c:42:a1:0b:99:8b" - pci_address: "0000:af:00.1" - ip4_address: "172.16.120.2" - driver: mlx5_core - link: link11 - model: Mellanox-CX556A - DUT1: - type: DUT - host: "10.32.8.20" - arch: x86_64 - port: 22 - username: testuser - password: Csit1234 - uio_driver: vfio-pci - interfaces: - port1: - # s35-t28-sut1-c2/p1 - 10GE port1 on Intel NIC x710 4p10GE. - mac_address: "3c:fd:fe:ca:e3:b0" - pci_address: "0000:18:00.0" - ip4_address: "172.16.10.1" - driver: i40e - link: disabled3 - model: Intel-X710 - port2: - # s35-t28-sut1-c2/p2 - 10GE port2 on Intel NIC x710 4p10GE. - mac_address: "3c:fd:fe:ca:e3:b1" - pci_address: "0000:18:00.1" - ip4_address: "172.16.20.1" - driver: i40e - link: disabled4 - model: Intel-X710 - port3: - # s35-t28-sut1-c2/p3 - 10GE port3 on Intel NIC x710 4p10GE. - mac_address: "3c:fd:fe:ca:e3:b2" - pci_address: "0000:18:00.2" - ip4_address: "172.16.30.1" - driver: i40e - link: link4 - model: Intel-X710 - port4: - # s35-t28-sut1-c2/p4 - 10GE port4 on Intel NIC x710 4p10GE. - mac_address: "3c:fd:fe:ca:e3:b3" - pci_address: "0000:18:00.3" - ip4_address: "172.16.40.1" - driver: i40e - link: link3 - model: Intel-X710 - port5: - # s35-t28-sut1-c2/p1 - 25GE port1 on Intel NIC xxv710 2p25GE. - mac_address: "3c:fd:fe:dd:d1:90" - pci_address: "0000:3b:00.0" - ip4_address: "172.16.50.1" - driver: i40e - link: link5 - model: Intel-XXV710 - port6: - # s35-t28-sut1-c2/p2 - 25GE port2 on Intel NIC xxv710 2p25GE. - mac_address: "3c:fd:fe:dd:d1:91" - pci_address: "0000:3b:00.1" - ip4_address: "172.16.60.1" - driver: i40e - link: link6 - model: Intel-XXV710 - port7: - # s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. - mac_address: "ec:0d:9a:8c:c7:b6" - pci_address: "0000:5e:00.0" - ip4_address: "172.16.70.1" - driver: mlx5_core - link: link7 - model: Mellanox-CX556A - port8: - # s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. - mac_address: "ec:0d:9a:8c:c7:b7" - pci_address: "0000:5e:00.1" - ip4_address: "172.16.80.1" - driver: mlx5_core - link: link8 - model: Mellanox-CX556A - port9: - # s35-t28-sut1-c6/p1 - 100GE-port1 Intel E810-CQDA2 2p100GE. - mac_address: "b4:96:91:a4:26:08" - pci_address: "0000:86:00.0" - ip4_address: "172.16.90.1" - driver: ice - link: link9 - model: Intel-E810CQ - port10: - # s35-t28-sut1-c6/p2 - 100GE-port1 Intel E810-CQDA2 2p100GE. - mac_address: "b4:96:91:a4:26:09" - pci_address: "0000:86:00.1" - ip4_address: "172.16.100.1" - driver: ice - link: link10 - model: Intel-E810CQ
\ No newline at end of file diff --git a/topologies/available/lf_2n_clx_testbed29.yaml b/topologies/available/lf_2n_clx_testbed29.yaml deleted file mode 100644 index 24cba15af9..0000000000 --- a/topologies/available/lf_2n_clx_testbed29.yaml +++ /dev/null @@ -1,187 +0,0 @@ ---- -metadata: - version: 0.1 - schema: - - resources/topology_schemas/2_node_topology.sch.yaml - - resources/topology_schemas/topology.sch.yaml - tags: [hw, 2-node] - -nodes: - TG: - type: TG - subtype: TREX - host: "10.32.8.23" - arch: x86_64 - port: 22 - username: testuser - password: Csit1234 - interfaces: - port1: - # s38-t29-tg1-c2/p1 - 10GE port1 on Intel NIC x710 4p10GE. - mac_address: "3c:fd:fe:a8:b1:90" - pci_address: "0000:18:00.0" - ip4_address: "172.16.10.2" - driver: i40e - link: disabled1 - model: Intel-X710 - port2: - # s38-t29-tg1-c2/p2 - 10GE port2 on Intel NIC x710 4p10GE. - mac_address: "3c:fd:fe:a8:b1:91" - pci_address: "0000:18:00.1" - ip4_address: "172.16.20.2" - driver: i40e - link: disabled2 - model: Intel-X710 - port3: - # s38-t29-tg1-c2/p3 - 10GE port3 on Intel NIC x710 4p10GE. - mac_address: "3c:fd:fe:a8:b1:92" - pci_address: "0000:18:00.2" - ip4_address: "172.16.30.2" - driver: i40e - link: link3 - model: Intel-X710 - port4: - # s38-t29-tg1-c2/p4 - 10GE port4 on Intel NIC x710 4p10GE. - mac_address: "3c:fd:fe:a8:b1:93" - pci_address: "0000:18:00.3" - ip4_address: "172.16.40.2" - driver: i40e - link: link4 - model: Intel-X710 - port5: - # s38-t29-tg1-c4/p1 - 25GE port1 on Intel NIC xxv710 2p25GE. - mac_address: "3c:fd:fe:cf:6c:bc" - pci_address: "0000:3b:00.0" - ip4_address: "172.16.50.2" - driver: i40e - link: link5 - model: Intel-XXV710 - port6: - # s38-t29-tg1-c4/p2 - 25GE port2 on Intel NIC xxv710 2p25GE. - mac_address: "3c:fd:fe:cf:6c:bd" - pci_address: "0000:3b:00.1" - ip4_address: "172.16.60.2" - driver: i40e - link: link6 - model: Intel-XXV710 - port7: - # s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. - mac_address: "b8:59:9f:fe:4a:a8" - pci_address: "0000:5e:00.0" - ip4_address: "172.16.70.2" - driver: mlx5_core - link: link7 - model: Mellanox-CX556A - port8: - # s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. - mac_address: "b8:59:9f:fe:4a:a9" - pci_address: "0000:5e:00.1" - ip4_address: "172.16.80.2" - driver: mlx5_core - link: link8 - model: Mellanox-CX556A - port9: - # s38-t29-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE. - mac_address: "10:70:fd:18:44:ec" - pci_address: "0000:86:00.0" - ip4_address: "172.16.90.2" - driver: mlx5_core - link: link9 - model: Mellanox-CX556A - port10: - # s38-t29-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE. - mac_address: "10:70:fd:18:44:ed" - pci_address: "0000:86:00.1" - ip4_address: "172.16.100.2" - driver: mlx5_core - link: link10 - model: Mellanox-CX556A - DUT1: - type: DUT - host: "10.32.8.22" - arch: x86_64 - port: 22 - username: testuser - password: Csit1234 - uio_driver: vfio-pci - interfaces: - port1: - # s37-t29-sut1-c2/p1 - 10GE port1 on Intel NIC x710 4p10GE. - mac_address: "3c:fd:fe:ca:eb:10" - pci_address: "0000:18:00.0" - ip4_address: "172.16.10.1" - driver: i40e - link: disabled3 - model: Intel-X710 - port2: - # s37-t29-sut1-c2/p2 - 10GE port2 on Intel NIC x710 4p10GE. - mac_address: "3c:fd:fe:ca:eb:11" - pci_address: "0000:18:00.1" - ip4_address: "172.16.20.1" - driver: i40e - link: disabled4 - model: Intel-X710 - port3: - # s37-t29-sut1-c2/p3 - 10GE port3 on Intel NIC x710 4p10GE. - mac_address: "3c:fd:fe:ca:eb:12" - pci_address: "0000:18:00.2" - ip4_address: "172.16.30.1" - driver: i40e - link: link3 - model: Intel-X710 - port4: - # s37-t29-sut1-c2/p4 - 10GE port4 on Intel NIC x710 4p10GE. - mac_address: "3c:fd:fe:ca:eb:13" - pci_address: "0000:18:00.3" - ip4_address: "172.16.40.1" - driver: i40e - link: link4 - model: Intel-X710 - port5: - # s37-t29-sut1-c2/p1 - 25GE port1 on Intel NIC xxv710 2p25GE. - mac_address: "3c:fd:fe:dd:d3:48" - pci_address: "0000:3b:00.0" - ip4_address: "172.16.50.1" - driver: i40e - link: link5 - model: Intel-XXV710 - port6: - # s37-t29-sut1-c2/p2 - 25GE port2 on Intel NIC xxv710 2p25GE. - mac_address: "3c:fd:fe:dd:d3:49" - pci_address: "0000:3b:00.1" - ip4_address: "172.16.60.1" - driver: i40e - link: link6 - model: Intel-XXV710 - port7: - # s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. - mac_address: "b8:59:9f:fe:4a:c8" - pci_address: "0000:5e:00.0" - ip4_address: "172.16.70.1" - driver: mlx5_core - link: link7 - model: Mellanox-CX556A - port8: - # s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. - mac_address: "b8:59:9f:fe:4a:c9" - pci_address: "0000:5e:00.1" - ip4_address: "172.16.80.1" - driver: mlx5_core - link: link8 - model: Mellanox-CX556A - port9: - # s37-t29-sut1-c6/p1 - 100GE-port1 Intel E810-CQDA2 2p100GE. - mac_address: "b4:96:91:a4:23:50" - pci_address: "0000:86:00.0" - ip4_address: "172.16.90.1" - driver: ice - link: link9 - model: Intel-E810CQ - port10: - # s37-t29-sut1-c6/p2 - 100GE-port1 Intel E810-CQDA2 2p100GE. - mac_address: "b4:96:91:a4:23:51" - pci_address: "0000:86:00.1" - ip4_address: "172.16.100.1" - driver: ice - link: link10 - model: Intel-E810CQ
\ No newline at end of file diff --git a/topologies/available/lf_2n_tx2_testbed34.yaml b/topologies/available/lf_2n_tx2_testbed34.yaml deleted file mode 100644 index cbaefc387a..0000000000 --- a/topologies/available/lf_2n_tx2_testbed34.yaml +++ /dev/null @@ -1,64 +0,0 @@ -# Copyright (c) 2020-2023 PANTHEON.tech and/or its affiliates. -# Licensed under the Apache License, Version 2.0 (the "License"); -# you may not use this file except in compliance with the License. -# You may obtain a copy of the License at: -# -# http://www.apache.org/licenses/LICENSE-2.0 -# -# Unless required by applicable law or agreed to in writing, software -# distributed under the License is distributed on an "AS IS" BASIS, -# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. -# See the License for the specific language governing permissions and -# limitations under the License. - ---- -metadata: - version: 0.1 - schema: # list of schema files against which to validate - - resources/topology_schemas/2_node_topology.sch.yaml - - resources/topology_schemas/topology.sch.yaml - tags: [hw, 2-node] - -nodes: - TG: - type: TG - subtype: TREX - host: 10.30.51.49 - arch: x86_64 - port: 6002 - username: root - password: Csit1234 - interfaces: - port0: - mac_address: "3c:fd:fe:c3:e9:70" - pci_address: "0000:af:00.0" - link: link1 - driver: i40e - model: Intel-XL710 - port1: - mac_address: "3c:fd:fe:c3:e9:71" - pci_address: "0000:af:00.1" - link: link2 - driver: i40e - model: Intel-XL710 - DUT1: - type: DUT - host: 10.30.51.69 - arch: aarch64 - port: 22 - uio_driver: vfio-pci - username: testuser - password: Csit1234 - interfaces: - port0: - mac_address: "3c:fd:fe:c3:e0:90" - pci_address: "0000:91:00.0" - link: link1 - driver: i40e - model: Intel-XL710 - port1: - mac_address: "3c:fd:fe:c3:e0:91" - pci_address: "0000:91:00.1" - link: link2 - driver: i40e - model: Intel-XL710 diff --git a/topologies/available/lf_3n_tsh_testbed33.yaml b/topologies/available/lf_3n_tsh_testbed33.yaml deleted file mode 100644 index 8d6397379a..0000000000 --- a/topologies/available/lf_3n_tsh_testbed33.yaml +++ /dev/null @@ -1,97 +0,0 @@ -# Copyright (c) 2020 PANTHEON.tech and/or its affiliates. -# Licensed under the Apache License, Version 2.0 (the "License"); -# you may not use this file except in compliance with the License. -# You may obtain a copy of the License at: -# -# http://www.apache.org/licenses/LICENSE-2.0 -# -# Unless required by applicable law or agreed to in writing, software -# distributed under the License is distributed on an "AS IS" BASIS, -# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. -# See the License for the specific language governing permissions and -# limitations under the License. - ---- -metadata: - version: 0.1 - schema: # list of schema files against which to validate - - resources/topology_schemas/3_node_topology.sch.yaml - - resources/topology_schemas/topology.sch.yaml - tags: [hw, 3-node] - -nodes: - TG: - type: TG - subtype: TREX - host: 10.30.51.49 - arch: x86_64 - port: 6001 - username: root - password: Csit1234 - interfaces: - port0: - mac_address: "3c:fd:fe:a8:aa:c0" - pci_address: "0000:18:00.0" - link: link2 - driver: i40e - model: Intel-X710 - port1: - mac_address: "3c:fd:fe:a8:aa:c1" - pci_address: "0000:18:00.1" - link: link1 - driver: i40e - model: Intel-X710 - port2: - mac_address: "3c:fd:fe:a8:aa:c2" - pci_address: "0000:18:00.2" - link: link10 - driver: i40e - model: Intel-X710 - port3: - mac_address: "3c:fd:fe:a8:aa:c3" - pci_address: "0000:18:00.3" - link: link11 - driver: i40e - model: Intel-X710 - DUT1: - type: DUT - host: 10.30.51.36 - arch: aarch64 - port: 22 - uio_driver: vfio-pci - username: testuser - password: Csit1234 - interfaces: - port0: - mac_address: "80:41:26:6f:19:81" - pci_address: "0000:11:00.0" - link: link3 - driver: ixgbe - model: Intel-X520-DA2 - port1: - mac_address: "80:41:26:6f:19:82" - pci_address: "0000:11:00.1" - link: link1 - driver: ixgbe - model: Intel-X520-DA2 - DUT2: - type: DUT - host: 10.30.51.37 - arch: aarch64 - port: 22 - username: testuser - uio_driver: vfio-pci - password: Csit1234 - interfaces: - port0: - mac_address: "80:41:26:6f:19:7d" - pci_address: "0000:11:00.0" - link: link2 - driver: ixgbe - model: Intel-X520-DA2 - port1: - mac_address: "80:41:26:6f:19:7e" - pci_address: "0000:11:00.1" - link: link3 - driver: ixgbe - model: Intel-X520-DA2 |