1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
1001
1002
1003
1004
1005
1006
1007
1008
1009
1010
1011
1012
1013
1014
1015
1016
1017
1018
1019
1020
1021
1022
1023
1024
1025
1026
1027
1028
1029
1030
1031
1032
1033
1034
1035
1036
1037
1038
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
1050
1051
1052
1053
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
1087
1088
1089
1090
1091
1092
1093
1094
1095
1096
1097
1098
1099
1100
1101
1102
1103
1104
1105
1106
1107
1108
1109
1110
1111
1112
1113
1114
1115
1116
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1139
1140
1141
1142
1143
1144
1145
1146
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1168
1169
1170
1171
1172
1173
1174
1175
1176
1177
1178
1179
1180
1181
1182
1183
1184
|
## FD.io CSIT Testbeds - Xeon Haswell
This is a low-level design implemented as an original FD.io CSIT lab based on
Cisco UCS-c240m4 servers based on Intel Xeon Haswell processors.
### Server Hardware Configuration
Total of 10 Cisco UCS-c240 servers with Intel Xeon Haswell processors have been
used to built FD.io CSIT 3-Node Haswell (3n-hsw) performance testbeds and VIRL
functional testbeds. Following three HW configuration types of UCS x86 servers
are used:
```
1. Type-1: Purpose - VPP functional and performance conformance testing.
- Quantity: 6 computers as SUT hosts (Systems Under Test).
- Physical connectivity:
- CIMC and host management ports.
- NIC ports connected in 3-node topologies.
- Main HW configuration:
- Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
- Processors: 2* E5-2699v3 2.3 GHz.
- RAM Memory: 16* 32GB DDR4-2133MHz.
- Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
- NICs configuration:
- Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
- PCIe Slot1: Cisco VIC 1385 2p40GE.
- PCIe Slot2: Intel NIC x520 2p10GE.
- PCIe Slot3: empty.
- Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
- PCIe Slot4: Intel NIC xl710 2p40GE.
- PCIe Slot5: Intel NIC x710 2p10GE.
- PCIe Slot6: Intel QAT 8950 50G (Walnut Hill)
- MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
2. Type-2: Purpose - VPP functional and performance conformance testing.
- Quantity: 3 computers as TG hosts (Traffic Generators).
- Physical connectivity:
- CIMC and host management ports.
- NIC ports connected in 3-node topologies.
- Main HW configuration:
- Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
- Processors: 2* E5-2699v3 2.3 GHz.
- RAM Memory: 16* 32GB DDR4-2133MHz.
- Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
- NICs configuration:
- Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
- PCIe Slot1: Intel NIC xl710 2p40GE.
- PCIe Slot2: Intel NIC x710 2p10GE.
- PCIe Slot3: Intel NIC x710 2p10GE.
- Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
- PCIe Slot4: Intel NIC xl710 2p40GE.
- PCIe Slot5: Intel NIC x710 2p10GE.
- PCIe Slot6: Intel NIC x710 2p10GE.
- MLOM slot: empty.
3. Type-3: Purpose - VIRL functional conformance.
- Quantity: 3 computers as VIRL hosts.
- Physical connectivity:
- CIMC and host management ports.
- no NIC ports, standalone setup.
- Main HW configuration:
- Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
- Processors: 2* E5-2699v3 2.3 GHz.
- RAM Memory: 16* 32GB DDR4-2133MHz.
- Disks: 2* 480 GB 2.5inch 6G SATA SSD.
- NICs configuration:
- Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
- no cards.
- Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
- no cards.
- MLOM slot: empty.
```
## Testbeds1,2,3 Connectivity
### Management Ports
Total of 10 UCSC-C240-M4SX servers is made available for FD.IO CSIT testbed. For
management purposes, each server must have following two ports connected to the
management network:
```
1. 1GE CIMC port
- CIMC - Cisco Integrated Management Controller.
- Required for provides embedded server management with WebUI, CLI, SNMPv3,
IPMIv2.0.
2. 1GE management port
- hostOS management port.
```
### Naming Convention
Following naming convention is used within this page to specify physical
connectivity and wiring across defined CSIT testbeds:
```
- testbedname: testbedN.
- hostname:
- traffic-generator: tN-tgW.
- system-under-testX: tN-sutX.
- portnames:
- tN-tgW-cY/pZ.
- tN-sutX-cY/pZ.
- where:
- N - testbed number.
- tgW - server acts as traffic-generator with W index.
- sutX - server acts as system-under-test with X index.
- Y - PCIe slot number denoting a NIC card number within the host.
- Y=1,2,3 - slots in Riser 1, Right PCIe Riser Board, NUMA node 0.
- Y=4,5,6 - slots in Riser 2, Left PCIe Riser Board, NUMA node 1.
- Y=m - the MLOM slot.
- Z - port number on the NIC card.
```
### 3-node Topology Testbeds for Performance
Nine servers are used to build three of 3-node topologies, with each topology
using two servers of Type-1 (SUT function) and one server of Type-2
(TG function). Server NIC cards are placed and NIC ports are connected using the
scheme defined in next sections.
### LOM (CIMC) and Management networks
Each server has a LOM (Lights-Out-Management e.g. Cisco CIMC) and a Management
port, which are connected to two different VLANs.
```
1. LOM (CIMC) VLAN:
- Subnet: 10.30.50.0/24
- Gateway: 10.30.50.1
- Broadcast: 10.30.50.255
- DNS1: 199.204.44.24
- DNS2: 199.204.47.54
2. Management Vlan:
- Subnet: 10.30.51.0/24
- Gateway: 10.30.51.1
- Broadcast: 10.30.51.255
- DNS1: 199.204.44.24
- DNS2: 199.204.47.54
```
To access these hosts, an VPN connection is required.
#### LOM (CIMC) VLAN IP Addresses allocation
Name | Comment
---- | -------
10.30.50.0 | network
10.30.51.1 | Router
10.30.50.2 | LF Reserved
10.30.50.3 | LF Reserved
10.30.50.4 | LF Reserved
10.30.50.5 | LF Reserved
10.30.50.6 | LF Reserved
10.30.50.7 | LF Reserved
10.30.50.8 | LF Reserved
10.30.50.9 | LF Reserved
10.30.50.10 | LF Reserved
10.30.50.11 | LF Reserved
10.30.50.12 | LF Reserved
10.30.50.13 | LF Reserved
10.30.50.14 | LF Reserved
10.30.50.15 | LF Reserved
10.30.50.16 | t1-tg1
10.30.50.17 | t1-sut1
10.30.50.18 | t1-sut2
10.30.50.20 | t2-tg1
10.30.50.21 | t2-sut1
10.30.50.22 | t2-sut2
10.30.50.24 | t3-tg1
10.30.50.25 | t3-sut1
10.30.50.26 | t3-sut-2
10.30.50.28 | t4-sut1
10.30.50.29 | t4-sut2
10.30.50.30 | t4-sut3
10.30.50.255 | Broadcast
#### Management VLAN IP Addresses allocation
Name | Comment
---- | -------
10.30.51.0 | network
10.30.51.1 | Router
10.30.51.2 | LF Reserved
10.30.51.3 | LF Reserved
10.30.51.4 | LF Reserved
10.30.51.5 | LF Reserved
10.30.51.6 | LF Reserved
10.30.51.7 | LF Reserved
10.30.51.8 | LF Reserved
10.30.51.9 | netgate-1
10.30.51.10 | netgate-2
10.30.51.11 | netgate-3
10.30.51.12 | softiron-1
10.30.51.13 | softiron-2
10.30.51.14 | softiron-3
10.30.51.15 | LF Reserved
10.30.51.16 | t1-tg1
10.30.51.17 | t1-sut1
10.30.51.18 | t1-sut2
10.30.51.20 | t2-tg1
10.30.51.21 | t2-sut1
10.30.51.22 | t2-sut2
10.30.51.24 | t3-tg1
10.30.51.25 | t3-sut1
10.30.51.26 | t3-sut-2
10.30.51.28 | t4-sut1
10.30.51.29 | t4-sut2
10.30.51.30 | t4-sut3
10.30.51.31-10.30.51.105 | VIRL1
10.30.51.106-10.30.51.180 | VIRL2
10.30.51.181-10.30.51.254 | VIRL3
10.30.51.255 | Broadcast
### Testbeds1,2,3 Naming: Servers, Ports
Each server in 3-node Topology has its NIC cards placed, and NIC cards and ports
indexed using defined naming convention:
```
1. Server1 of Type-1:
- testbedname: testbed1.
- hostname: t1-sut1.
- CIMC IP: 10.30.50.17
- Host IP: 10.30.51.17
- portnames:
- t1-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
- t1-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
- t1-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
- t1-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
- t1-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- t1-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- t1-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
- t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
2. Server2 of Type-1:
- testbedname: testbed1.
- hostname: t1-sut2.
- CIMC IP: 10.30.50.18
- Host IP: 10.30.51.18
- portnames:
- t1-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
- t1-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
- t1-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
- t1-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
- t1-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- t1-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- t1-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
- t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
3. Server3 of Type-2:
- testbedname: testbed1.
- hostname: t1-tg1.
- CIMC IP: 10.30.50.16
- Host IP: 10.30.51.16
- portnames:
- t1-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- t1-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- t1-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- t1-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- t1-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- t1-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- t1-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- t1-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- t1-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
4. Server4 of Type-1:
- testbedname: testbed2.
- hostname: t2-sut1.
- CIMC IP: 10.30.50.21
- Host IP: 10.30.51.21
- portnames:
- t2-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
- t2-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
- t2-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
- t2-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
- t2-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- t2-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- t2-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
- t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
5. Server5 of Type-1:
- testbedname: testbed2.
- hostname: t2-sut2.
- CIMC IP: 10.30.50.22
- Host IP: 10.30.51.22
- portnames:
- t2-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
- t2-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
- t2-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
- t2-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
- t2-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- t2-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- t2-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
- t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
6. Server6 of Type-2:
- testbedname: testbed2.
- hostname: t2-tg1.
- CIMC IP: 10.30.50.20
- Host IP: 10.30.51.20
- portnames:
- t2-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- t2-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- t2-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- t2-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- t2-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- t2-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- t2-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- t2-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- t2-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
7. Server7 of Type-1:
- testbedname: testbed3.
- hostname: t3-sut1.
- CIMC IP: 10.30.50.25
- Host IP: 10.30.51.25
- portnames:
- t3-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
- t3-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
- t3-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
- t3-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
- t3-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- t3-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- t3-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
- t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
8. Server8 of Type-1:
- testbedname: testbed3.
- hostname: t3-sut2.
- CIMC IP: 10.30.50.26
- Host IP: 10.30.51.26
- portnames:
- t3-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
- t3-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
- t3-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
- t3-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
- t3-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- t3-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- t3-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
- t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
9. Server9 of Type-2:
- testbedname: testbed3.
- hostname: t3-tg1.
- CIMC IP: 10.30.50.24
- Host IP: 10.30.51.24
- portnames:
- t3-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- t3-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- t3-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- t3-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- t3-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- t3-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- t3-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- t3-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- t3-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- t3-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- t3-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- t3-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
```
### Testbeds1,2,3 Network Connectivity
Listed nine servers are connected into the three of 3-node testbeds, testbed1,
testbed2 and testbed3, using defined naming convention as follows:
```
1. testbed1:
- ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
- t1-tg1-c1/p1 to t1-sut1-c1/p2.
- t1-sut1-c1/p1 to t1-sut2-c1/p2.
- t1-sut2-c1/p1 to t1-tg1-c1/p2.
- ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
- t1-tg1-c2/p1 to t1-sut1-c2/p2.
- t1-sut1-c2/p1 to t1-sut2-c2/p2.
- t1-sut2-c2/p1 to t1-tg1-c2/p2.
- ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
- t1-tg1-c4/p1 to t1-sut1-c4/p2.
- t1-sut1-c4/p1 to t1-sut2-c4/p2.
- t1-sut2-c4/p1 to t1-tg1-c4/p2.
- ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
- t1-tg1-c5/p1 to t1-sut1-c5/p2.
- t1-sut1-c5/p1 to t1-sut2-c5/p2.
- t1-sut2-c5/p1 to t1-tg1-c5/p2.
- ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
- t1-tg1-c2/p1 to t1-sut1-cm/p2.
- t1-sut1-cm/p1 to t1-sut2-cm/p2.
- t1-sut2-cm/p1 to t1-tg1-c2/p2.
- TG loopback ports Intel NIC x710 2p10GE
- t1-tg1-c6/p1 to t1-tg1-c6/p2.
2. testbed2:
- ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
- t2-tg1-c1/p1 to t2-sut1-c1/p2.
- t2-sut1-c1/p1 to t2-sut2-c1/p2.
- t2-sut2-c1/p1 to t2-tg1-c1/p2.
- ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
- t2-tg1-c2/p1 to t2-sut1-c2/p2.
- t2-sut1-c2/p1 to t2-sut2-c2/p2.
- t2-sut2-c2/p1 to t2-tg1-c2/p2.
- ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
- t2-tg1-c4/p1 to t2-sut1-c4/p2.
- t2-sut1-c4/p1 to t2-sut2-c4/p2.
- t2-sut2-c4/p1 to t2-tg1-c4/p2.
- ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
- t2-tg1-c5/p1 to t2-sut1-c5/p2.
- t2-sut1-c5/p1 to t2-sut2-c5/p2.
- t2-sut2-c5/p1 to t2-tg1-c5/p2.
- ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
- t2-tg1-c2/p1 to t2-sut1-cm/p2.
- t2-sut1-cm/p1 to t2-sut2-cm/p2.
- t2-sut2-cm/p1 to t2-tg1-c2/p2.
- TG loopback ports Intel NIC x710 2p10GE
- t2-tg1-c6/p1 to t2-tg1-c6/p2.
3. testbed3:
- ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
- t3-tg1-c1/p1 to t3-sut1-c1/p2.
- t3-sut1-c1/p1 to t3-sut2-c1/p2.
- t3-sut2-c1/p1 to t3-tg1-c1/p2.
- ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
- t3-tg1-c2/p1 to t3-sut1-c2/p2.
- t3-sut1-c2/p1 to t3-sut2-c2/p2.
- t3-sut2-c2/p1 to t3-tg1-c2/p2.
- ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
- t3-tg1-c4/p1 to t3-sut1-c4/p2.
- t3-sut1-c4/p1 to t3-sut2-c4/p2.
- t3-sut2-c4/p1 to t3-tg1-c4/p2.
- ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
- t3-tg1-c5/p1 to t3-sut1-c5/p2.
- t3-sut1-c5/p1 to t3-sut2-c5/p2.
- t3-sut2-c5/p1 to t3-tg1-c5/p2.
- ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
- t3-tg1-c2/p1 to t3-sut1-cm/p2.
- t3-sut1-cm/p1 to t3-sut2-cm/p2.
- t3-sut2-cm/p1 to t3-tg1-c2/p2.
- TG loopback ports Intel NIC x710 2p10GE
- t3-tg1-c6/p1 to t3-tg1-c6/p2.
```
## Testbeds1,2,3 Server Specifications
### Linux lscpu
```
$ lscpu
Architecture: x86_64
CPU op-mode(s): 32-bit, 64-bit
Byte Order: Little Endian
CPU(s): 36
On-line CPU(s) list: 0-35
Thread(s) per core: 1
Core(s) per socket: 18
Socket(s): 2
NUMA node(s): 2
Vendor ID: GenuineIntel
CPU family: 6
Model: 63
Model name: Intel(R) Xeon(R) CPU E5-2699 v3 @ 2.30GHz
Stepping: 2
CPU MHz: 2294.249
BogoMIPS: 4589.82
Virtualization: VT-x
L1d cache: 32K
L1i cache: 32K
L2 cache: 256K
L3 cache: 46080K
NUMA node0 CPU(s): 0-17
NUMA node1 CPU(s): 18-35
Flags: fpu vme de pse tsc msr pae mce cx8 apic sep mtrr pge mca cmov pat pse36 clflush dts acpi mmx fxsr sse sse2 ss ht tm pbe syscall nx pdpe1gb rdtscp lm constant_tsc arch_perfmon pebs bts rep_good nopl xtopology nonstop_tsc aperfmperf eagerfpu pni pclmulqdq
dtes64 monitor ds_cpl vmx smx est tm2 ssse3 sdbg fma cx16 xtpr pdcm pcid dca sse4_1 sse4_2 x2apic movbe popcnt tsc_deadline_timer aes xsave avx f16c rdrand lahf_lm abm epb tpr_shadow vnmi flexpriority ept vpid fsgsbase tsc_adjust bmi1 avx2 smep bmi2 erms invpcid cqm xsaveopt
cqm_llc cqm_occup_llc dtherm arat pln pts
```
### Linux dmidecode pci
```
$ dmidecode --type 9 | grep 'Handle\|Slot\|Type\|Address'
Handle 0x0046, DMI type 9, 17 bytes
System Slot Information
Designation: SlotID:1
Type: x8 PCI Express 3 x8
Bus Address: 0000:0a:02.0
Handle 0x0047, DMI type 9, 17 bytes
System Slot Information
Designation: SlotID:2
Type: x8 PCI Express 3 x8
Bus Address: 0000:0e:03.2
Handle 0x0048, DMI type 9, 17 bytes
System Slot Information
Designation: SlotID:3
Type: x8 PCI Express 3 x8
Bus Address: 0000:0d:03.0
Handle 0x0049, DMI type 9, 17 bytes
System Slot Information
Designation: SlotID:4
Type: x8 PCI Express 3 x8
Bus Address: 0000:85:02.2
Handle 0x004A, DMI type 9, 17 bytes
System Slot Information
Designation: SlotID:5
Type: x8 PCI Express 3 x16
Bus Address: 0000:87:03.0
Handle 0x004B, DMI type 9, 17 bytes
System Slot Information
Designation: SlotID:6
Type: x8 PCI Express 3 x8
Bus Address: 0000:84:02.0
Handle 0x004C, DMI type 9, 17 bytes
System Slot Information
Designation: SlotID:MLOM
Type: x8 Other
Bus Address: 0000:01:01.0
Handle 0x004D, DMI type 9, 17 bytes
System Slot Information
Designation: SlotID:HBA
Type: x8 Other
Bus Address: 0000:0c:02.2
Handle 0x004E, DMI type 9, 17 bytes
System Slot Information
Designation: SlotID:NVMe1
Type: x4 PCI Express 3 x4
Bus Address: 0000:82:01.0
Handle 0x004F, DMI type 9, 17 bytes
System Slot Information
Designation: SlotID:NVMe2
Type: x4 PCI Express 3 x4
Bus Address: 0000:83:01.1
Handle 0x0050, DMI type 9, 17 bytes
System Slot Information
Designation: SlotID:2.1
Type: x16 PCI Express 3 x16
Bus Address: 0000:00:1f.7
Handle 0x0051, DMI type 9, 17 bytes
System Slot Information
Designation: SlotID:2.2
Type: x16 PCI Express 3 x16
Bus Address: 0000:00:1f.7
Handle 0x0052, DMI type 9, 17 bytes
System Slot Information
Designation: SlotID:2.3
Type: x16 PCI Express 3 x16
Bus Address: 0000:00:1f.7
Handle 0x0053, DMI type 9, 17 bytes
System Slot Information
Designation: SlotID:2.4
Type: x16 PCI Express 3 x16
Bus Address: 0000:00:1f.7
Handle 0x0054, DMI type 9, 17 bytes
System Slot Information
Designation: SlotID:2.5
Type: x16 PCI Express 3 x16
Bus Address: 0000:00:1f.7
Handle 0x0055, DMI type 9, 17 bytes
System Slot Information
Designation: SlotID:5.1
Type: x8 PCI Express 3 x16
Bus Address: 0000:00:1f.7
Handle 0x0056, DMI type 9, 17 bytes
System Slot Information
Designation: SlotID:5.2
Type: x8 PCI Express 3 x16
Bus Address: 0000:00:1f.7
Handle 0x0057, DMI type 9, 17 bytes
System Slot Information
Designation: SlotID:5.3
Type: x8 PCI Express 3 x16
Bus Address: 0000:00:1f.7
Handle 0x0058, DMI type 9, 17 bytes
System Slot Information
Designation: SlotID:5.4
Type: x8 PCI Express 3 x16
Bus Address: 0000:00:1f.7
Handle 0x0059, DMI type 9, 17 bytes
System Slot Information
Designation: SlotID:5.5
Type: x8 PCI Express 3 x16
Bus Address: 0000:00:1f.7
```
### Linux dmidecode memory
```
$ dmidecode -t memory
# dmidecode 2.12
SMBIOS 2.8 present.
Handle 0x0022, DMI type 16, 23 bytes
Physical Memory Array
Location: System Board Or Motherboard
Use: System Memory
Error Correction Type: Multi-bit ECC
Maximum Capacity: 1536 GB
Error Information Handle: Not Provided
Number Of Devices: 24
Handle 0x0024, DMI type 17, 34 bytes
Memory Device
Array Handle: 0x0022
Error Information Handle: Not Provided
Total Width: 72 bits
Data Width: 64 bits
Size: 32 GB
Form Factor: DIMM
Set: None
Locator: DIMM_A1
Bank Locator: NODE 0 CHANNEL 0 DIMM 0
Type: Other
Type Detail: None
Speed: 2133 MHz
Manufacturer: 0xAD00
Serial Number: 80EC7380
Asset Tag: DIMM_A1_AssetTag
Part Number: HMA84GL7MMR4N-TF
Rank: 4
Configured Clock Speed: 2133 MHz
Handle 0x0025, DMI type 17, 34 bytes
Memory Device
Array Handle: 0x0022
Error Information Handle: Not Provided
Total Width: 72 bits
Data Width: 64 bits
Size: 32 GB
Form Factor: DIMM
Set: None
Locator: DIMM_A2
Bank Locator: NODE 0 CHANNEL 0 DIMM 1
Type: Other
Type Detail: None
Speed: 2133 MHz
Manufacturer: 0xAD00
Serial Number: 80EC73D1
Asset Tag: DIMM_A2_AssetTag
Part Number: HMA84GL7MMR4N-TF
Rank: 4
Configured Clock Speed: 2133 MHz
Handle 0x0026, DMI type 17, 34 bytes
Memory Device
Array Handle: 0x0022
Error Information Handle: Not Provided
Total Width: Unknown
Data Width: Unknown
Size: No Module Installed
Form Factor: DIMM
Set: None
Locator: DIMM_A3
Bank Locator: NODE 0 CHANNEL 0 DIMM 2
Type: Other
Type Detail: None
Speed: Unknown
Manufacturer: NO DIMM
Serial Number: NO DIMM
Asset Tag: NO DIMM
Part Number: NO DIMM
Rank: Unknown
Configured Clock Speed: Unknown
Handle 0x0027, DMI type 17, 34 bytes
Memory Device
Array Handle: 0x0022
Error Information Handle: Not Provided
Total Width: 72 bits
Data Width: 64 bits
Size: 32 GB
Form Factor: DIMM
Set: None
Locator: DIMM_B1
Bank Locator: NODE 0 CHANNEL 1 DIMM 0
Type: Other
Type Detail: None
Speed: 2133 MHz
Manufacturer: 0xAD00
Serial Number: 80EC7325
Asset Tag: DIMM_B1_AssetTag
Part Number: HMA84GL7MMR4N-TF
Rank: 4
Configured Clock Speed: 2133 MHz
Handle 0x0028, DMI type 17, 34 bytes
Memory Device
Array Handle: 0x0022
Error Information Handle: Not Provided
Total Width: 72 bits
Data Width: 64 bits
Size: 32 GB
Form Factor: DIMM
Set: None
Locator: DIMM_B2
Bank Locator: NODE 0 CHANNEL 1 DIMM 1
Type: Other
Type Detail: None
Speed: 2133 MHz
Manufacturer: 0xAD00
Serial Number: 80EC7334
Asset Tag: DIMM_B2_AssetTag
Part Number: HMA84GL7MMR4N-TF
Rank: 4
Configured Clock Speed: 2133 MHz
Handle 0x0029, DMI type 17, 34 bytes
Memory Device
Array Handle: 0x0022
Error Information Handle: Not Provided
Total Width: Unknown
Data Width: Unknown
Size: No Module Installed
Form Factor: DIMM
Set: None
Locator: DIMM_B3
Bank Locator: NODE 0 CHANNEL 1 DIMM 2
Type: Other
Type Detail: None
Speed: Unknown
Manufacturer: NO DIMM
Serial Number: NO DIMM
Asset Tag: NO DIMM
Part Number: NO DIMM
Rank: Unknown
Configured Clock Speed: Unknown
Handle 0x002A, DMI type 17, 34 bytes
Memory Device
Array Handle: 0x0022
Error Information Handle: Not Provided
Total Width: 72 bits
Data Width: 64 bits
Size: 32 GB
Form Factor: DIMM
Set: None
Locator: DIMM_C1
Bank Locator: NODE 0 CHANNEL 2 DIMM 0
Type: Other
Type Detail: None
Speed: 2133 MHz
Manufacturer: 0xAD00
Serial Number: 80EC7329
Asset Tag: DIMM_C1_AssetTag
Part Number: HMA84GL7MMR4N-TF
Rank: 4
Configured Clock Speed: 2133 MHz
Handle 0x002B, DMI type 17, 34 bytes
Memory Device
Array Handle: 0x0022
Error Information Handle: Not Provided
Total Width: 72 bits
Data Width: 64 bits
Size: 32 GB
Form Factor: DIMM
Set: None
Locator: DIMM_C2
Bank Locator: NODE 0 CHANNEL 2 DIMM 1
Type: Other
Type Detail: None
Speed: 2133 MHz
Manufacturer: 0xAD00
Serial Number: 80EC732D
Asset Tag: DIMM_C2_AssetTag
Part Number: HMA84GL7MMR4N-TF
Rank: 4
Configured Clock Speed: 2133 MHz
Handle 0x002C, DMI type 17, 34 bytes
Memory Device
Array Handle: 0x0022
Error Information Handle: Not Provided
Total Width: Unknown
Data Width: Unknown
Size: No Module Installed
Form Factor: DIMM
Set: None
Locator: DIMM_C3
Bank Locator: NODE 0 CHANNEL 2 DIMM 2
Type: Other
Type Detail: None
Speed: Unknown
Manufacturer: NO DIMM
Serial Number: NO DIMM
Asset Tag: NO DIMM
Part Number: NO DIMM
Rank: Unknown
Configured Clock Speed: Unknown
Handle 0x002D, DMI type 17, 34 bytes
Memory Device
Array Handle: 0x0022
Error Information Handle: Not Provided
Total Width: 72 bits
Data Width: 64 bits
Size: 32 GB
Form Factor: DIMM
Set: None
Locator: DIMM_D1
Bank Locator: NODE 0 CHANNEL 3 DIMM 0
Type: Other
Type Detail: None
Speed: 2133 MHz
Manufacturer: 0xAD00
Serial Number: 80EC73D3
Asset Tag: DIMM_D1_AssetTag
Part Number: HMA84GL7MMR4N-TF
Rank: 4
Configured Clock Speed: 2133 MHz
Handle 0x002E, DMI type 17, 34 bytes
Memory Device
Array Handle: 0x0022
Error Information Handle: Not Provided
Total Width: 72 bits
Data Width: 64 bits
Size: 32 GB
Form Factor: DIMM
Set: None
Locator: DIMM_D2
Bank Locator: NODE 0 CHANNEL 3 DIMM 1
Type: Other
Type Detail: None
Speed: 2133 MHz
Manufacturer: 0xAD00
Serial Number: 80EC7330
Asset Tag: DIMM_D2_AssetTag
Part Number: HMA84GL7MMR4N-TF
Rank: 4
Configured Clock Speed: 2133 MHz
Handle 0x002F, DMI type 17, 34 bytes
Memory Device
Array Handle: 0x0022
Error Information Handle: Not Provided
Total Width: Unknown
Data Width: Unknown
Size: No Module Installed
Form Factor: DIMM
Set: None
Locator: DIMM_D3
Bank Locator: NODE 0 CHANNEL 3 DIMM 2
Type: Other
Type Detail: None
Speed: Unknown
Manufacturer: NO DIMM
Serial Number: NO DIMM
Asset Tag: NO DIMM
Part Number: NO DIMM
Rank: Unknown
Configured Clock Speed: Unknown
Handle 0x0030, DMI type 17, 34 bytes
Memory Device
Array Handle: 0x0022
Error Information Handle: Not Provided
Total Width: 72 bits
Data Width: 64 bits
Size: 32 GB
Form Factor: DIMM
Set: None
Locator: DIMM_E1
Bank Locator: NODE 1 CHANNEL 0 DIMM 0
Type: Other
Type Detail: None
Speed: 2133 MHz
Manufacturer: 0xAD00
Serial Number: 80E54252
Asset Tag: DIMM_E1_AssetTag
Part Number: HMA84GL7MMR4N-TF
Rank: 4
Configured Clock Speed: 2133 MHz
Handle 0x0031, DMI type 17, 34 bytes
Memory Device
Array Handle: 0x0022
Error Information Handle: Not Provided
Total Width: 72 bits
Data Width: 64 bits
Size: 32 GB
Form Factor: DIMM
Set: None
Locator: DIMM_E2
Bank Locator: NODE 1 CHANNEL 0 DIMM 1
Type: Other
Type Detail: None
Speed: 2133 MHz
Manufacturer: 0xAD00
Serial Number: 80E54235
Asset Tag: DIMM_E2_AssetTag
Part Number: HMA84GL7MMR4N-TF
Rank: 4
Configured Clock Speed: 2133 MHz
Handle 0x0032, DMI type 17, 34 bytes
Memory Device
Array Handle: 0x0022
Error Information Handle: Not Provided
Total Width: Unknown
Data Width: Unknown
Size: No Module Installed
Form Factor: DIMM
Set: None
Locator: DIMM_E3
Bank Locator: NODE 1 CHANNEL 0 DIMM 2
Type: Other
Type Detail: None
Speed: Unknown
Manufacturer: NO DIMM
Serial Number: NO DIMM
Asset Tag: NO DIMM
Part Number: NO DIMM
Rank: Unknown
Configured Clock Speed: Unknown
Handle 0x0033, DMI type 17, 34 bytes
Memory Device
Array Handle: 0x0022
Error Information Handle: Not Provided
Total Width: 72 bits
Data Width: 64 bits
Size: 32 GB
Form Factor: DIMM
Set: None
Locator: DIMM_F1
Bank Locator: NODE 1 CHANNEL 1 DIMM 0
Type: Other
Type Detail: None
Speed: 2133 MHz
Manufacturer: 0xAD00
Serial Number: 80E54218
Asset Tag: DIMM_F1_AssetTag
Part Number: HMA84GL7MMR4N-TF
Rank: 4
Configured Clock Speed: 2133 MHz
Handle 0x0034, DMI type 17, 34 bytes
Memory Device
Array Handle: 0x0022
Error Information Handle: Not Provided
Total Width: 72 bits
Data Width: 64 bits
Size: 32 GB
Form Factor: DIMM
Set: None
Locator: DIMM_F2
Bank Locator: NODE 1 CHANNEL 1 DIMM 1
Type: Other
Type Detail: None
Speed: 2133 MHz
Manufacturer: 0xAD00
Serial Number: 80E54236
Asset Tag: DIMM_F2_AssetTag
Part Number: HMA84GL7MMR4N-TF
Rank: 4
Configured Clock Speed: 2133 MHz
Handle 0x0035, DMI type 17, 34 bytes
Memory Device
Array Handle: 0x0022
Error Information Handle: Not Provided
Total Width: Unknown
Data Width: Unknown
Size: No Module Installed
Form Factor: DIMM
Set: None
Locator: DIMM_F3
Bank Locator: NODE 1 CHANNEL 1 DIMM 2
Type: Other
Type Detail: None
Speed: Unknown
Manufacturer: NO DIMM
Serial Number: NO DIMM
Asset Tag: NO DIMM
Part Number: NO DIMM
Rank: Unknown
Configured Clock Speed: Unknown
Handle 0x0036, DMI type 17, 34 bytes
Memory Device
Array Handle: 0x0022
Error Information Handle: Not Provided
Total Width: 72 bits
Data Width: 64 bits
Size: 32 GB
Form Factor: DIMM
Set: None
Locator: DIMM_G1
Bank Locator: NODE 1 CHANNEL 2 DIMM 0
Type: Other
Type Detail: None
Speed: 2133 MHz
Manufacturer: 0xAD00
Serial Number: 80E54247
Asset Tag: DIMM_G1_AssetTag
Part Number: HMA84GL7MMR4N-TF
Rank: 4
Configured Clock Speed: 2133 MHz
Handle 0x0037, DMI type 17, 34 bytes
Memory Device
Array Handle: 0x0022
Error Information Handle: Not Provided
Total Width: 72 bits
Data Width: 64 bits
Size: 32 GB
Form Factor: DIMM
Set: None
Locator: DIMM_G2
Bank Locator: NODE 1 CHANNEL 2 DIMM 1
Type: Other
Type Detail: None
Speed: 2133 MHz
Manufacturer: 0xAD00
Serial Number: 80E5421E
Asset Tag: DIMM_G2_AssetTag
Part Number: HMA84GL7MMR4N-TF
Rank: 4
Configured Clock Speed: 2133 MHz
Handle 0x0038, DMI type 17, 34 bytes
Memory Device
Array Handle: 0x0022
Error Information Handle: Not Provided
Total Width: Unknown
Data Width: Unknown
Size: No Module Installed
Form Factor: DIMM
Set: None
Locator: DIMM_G3
Bank Locator: NODE 1 CHANNEL 2 DIMM 2
Type: Other
Type Detail: None
Speed: Unknown
Manufacturer: NO DIMM
Serial Number: NO DIMM
Asset Tag: NO DIMM
Part Number: NO DIMM
Rank: Unknown
Configured Clock Speed: Unknown
Handle 0x0039, DMI type 17, 34 bytes
Memory Device
Array Handle: 0x0022
Error Information Handle: Not Provided
Total Width: 72 bits
Data Width: 64 bits
Size: 32 GB
Form Factor: DIMM
Set: None
Locator: DIMM_H1
Bank Locator: NODE 1 CHANNEL 3 DIMM 0
Type: Other
Type Detail: None
Speed: 2133 MHz
Manufacturer: 0xAD00
Serial Number: 80E5423C
Asset Tag: DIMM_H1_AssetTag
Part Number: HMA84GL7MMR4N-TF
Rank: 4
Configured Clock Speed: 2133 MHz
Handle 0x003A, DMI type 17, 34 bytes
Memory Device
Array Handle: 0x0022
Error Information Handle: Not Provided
Total Width: 72 bits
Data Width: 64 bits
Size: 32 GB
Form Factor: DIMM
Set: None
Locator: DIMM_H2
Bank Locator: NODE 1 CHANNEL 3 DIMM 1
Type: Other
Type Detail: None
Speed: 2133 MHz
Manufacturer: 0xAD00
Serial Number: 80E5424D
Asset Tag: DIMM_H2_AssetTag
Part Number: HMA84GL7MMR4N-TF
Rank: 4
Configured Clock Speed: 2133 MHz
Handle 0x003B, DMI type 17, 34 bytes
Memory Device
Array Handle: 0x0022
Error Information Handle: Not Provided
Total Width: Unknown
Data Width: Unknown
Size: No Module Installed
Form Factor: DIMM
Set: None
Locator: DIMM_H3
Bank Locator: NODE 1 CHANNEL 3 DIMM 2
Type: Other
Type Detail: None
Speed: Unknown
Manufacturer: NO DIMM
Serial Number: NO DIMM
Asset Tag: NO DIMM
Part Number: NO DIMM
Rank: Unknown
Configured Clock Speed: Unknown
```
### Xeon Hsw Server BIOS Configuration
```
C240 / # scope bios
C240 /bios # show advanced detail
Set-up parameters:
Intel(R) VT-d ATS Support: Enabled
Adjacent Cache Line Prefetcher: Enabled
All Onboard LOM Ports: Enabled
Altitude: 300 M
Bits per second: 115200
Power Technology: Performance
Channel Interleaving: Auto
Intel(R) VT-d Coherency Support: Disabled
Console Redirection: COM 0
Number of Enabled Cores: All
Energy Performance: Performance
CPU Performance: Enterprise
DCU IP Prefetcher: Enabled
DCU Streamer Prefetch: Enabled
Demand Scrub: Enabled
Direct Cache Access Support: Auto
Enhanced Intel Speedstep(R) Tec: Disabled
Execute Disable: Enabled
Flow Control: None
Hardware Prefetcher: Enabled
Intel(R) Hyper-Threading Techno: Disabled
Intel(R) Turbo Boost Technology: Disabled
Intel(R) VT: Enabled
Intel(R) VT-d: Enabled
Intel(R) Interrupt Remapping: Enabled
Legacy USB Support: Enabled
Extended APIC: XAPIC
LOM Port 1 OptionROM: Enabled
LOM Port 2 OptionROM: Enabled
MMIO above 4GB: Enabled
NUMA: Enabled
PCI ROM CLP: Disabled
Package C State Limit: C6 Retention
Intel(R) Pass Through DMA: Disabled
Patrol Scrub: Enabled
xHCI Mode: Disabled
All PCIe Slots OptionROM: Enabled
PCIe Slot:1 OptionROM: Disabled
PCIe Slot:2 OptionROM: Disabled
PCIe Slot:3 OptionROM: Disabled
PCIe Slot:4 OptionROM: Disabled
PCIe Slot:5 OptionROM: Disabled
PCIe Slot:6 OptionROM: Disabled
PCIe Slot:HBA Link Speed: GEN3
PCIe Slot:HBA OptionROM: Enabled
PCIe Slot:MLOM OptionROM: Enabled
PCIe Slot:N1 OptionROM: Enabled
PCIe Slot:N2 OptionROM: Enabled
Processor Power state C1 Enhanc: Disabled
Processor C3 Report: Disabled
Processor C6 Report: Disabled
P-STATE Coordination: HW ALL
Putty KeyPad: ESCN
Energy Performance Tuning: BIOS
QPI Link Frequency Select: Auto
QPI Snoop Mode: Home Snoop
Rank Interleaving: Auto
Redirection After BIOS POST: Always Enable
PCH SATA Mode: AHCI
Select Memory RAS: Maximum Performance
SR-IOV Support: Enabled
Terminal Type: VT100
Port 60/64 Emulation: Enabled
Workload Configuration: Balanced
CDN Support for VIC: Disabled
Out-of-Band Management: Disabled
C240-FCH1950V1H5 /bios/advanced #
```
|