aboutsummaryrefslogtreecommitdiffstats
path: root/docs/lab/fdio-dc-physical.md
blob: b049073379f7777a6e09143544ccfd30423a61f2 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
<!-- MarkdownTOC autolink="true" -->

- [FD.io DC Vexxhost Inventory](#fdio-dc-vexxhost-inventory)
  - [Missing Equipment Inventory](#missing-equipment-inventory)
  - [YUL1 Inventory](#yul1-inventory)
    - [Rack YUL1-8 (3016.8)](#rack-yul1-8-3016.8)
    - [Rack YUL1-9 (3016.9)](#rack-yul1-9-3016.9)
    - [Rack YUL1-10 (3016.10)](#rack-yul1-10-3016.10)
    - [Rack YUL1-11 (3016.11)](#rack-yul1-11-3016.11)
    - [Rack YUL1-12 (3016.12)](#rack-yul1-12-3016.12)

<!-- /MarkdownTOC -->

## FD.io DC Vexxhost Inventory

- for each DC location, per rack .csv table with server inventory
- captured inventory data: name,oper-status,testbed-id,role,model,s/n,rackid,rackunit,mgmt-ip4,ipmi-ip4,new-rackid,new-rackunit,new-mgmt-ip4,new-ipmi-ip4
  - name: CSIT functional server name as tracked in [CSIT testbed specification](https://git.fd.io/csit/tree/docs/lab/testbed_specifications.md), followed by "/" and the actual configured hostname, unless it is the same as CSIT name.
  - oper-status: operational status (up|down|ipmi).
  - testbed-id: CSIT testbed identifier.
  - role: 2n/3n-xxx performance testbed, nomad-client, nomad-server.
    - role exceptions: decommission, repurpose, spare.
  - model: server model.
  - s/n: serial number.
  - mgmt-ip4: current management IPv4 address on management VLAN.
  - ipmi-ip4: current IPMI IPv4 address on LOM VLAN.
  - rackid: new location rack id.
  - rackunit: new location rack unit id.

### Missing Equipment Inventory

1. Ixia PerfectStorm One Appliance
   - [Specification: Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.](https://git.fd.io/csit/tree/docs/lab/testbed_specifications.md#n554)
   - [Wiring: 2-Node-IxiaPS1L47 Servers (2n-ps1)](https://git.fd.io/csit/tree/docs/lab/testbed_specifications.md#n1017)
   - [mgmt-ip4 10.30.51.62 s26-t25-tg1](https://git.fd.io/csit/tree/docs/lab/testbed_specifications.md#n374)
   - [ipmi-ip4 10.30.50.59 s26-t25-tg1](https://git.fd.io/csit/tree/docs/lab/testbed_specifications.md#n281)

### YUL1 Inventory

#### Rack YUL1-8 (3016.8)
name,oper-status,testbed-id,role,model,s/n,mgmt-ip4,ipmi-ip4,rackid,rackunit
mtl1-8-lb4m,up,switch,uplink,?,?,?,?,3016.8,u47,?,?
s65-t37-sut1,up,t37,3n-icx,SYS-740GP-TNRT,C7470KK25P50098,10.30.51.75,10.30.50.75,3016.8,u42-u45
s66-t37-sut2,up,t37,3n-icx,SYS-740GP-TNRT,C7470KK33P50247,10.30.51.76,10.30.50.76,3016.8,u38-u41
s67-t37-tg1,up,t37,3n-icx,SYS-740GP-TNRT,C7470KK25P50076,10.30.51.77,10.30.50.77,3016.8,u34-u37
s71-t212-sut1,up,t212,2n-icx,SYS-740GP-TNRT,C7470KK25P50173,10.30.51.81,10.30.50.81,3016.8,u30-u33
s72-t212-tg1,up,t212,2n-icx,SYS-740GP-TNRT,C7470KK33P50220,10.30.51.82,10.30.50.82,3016.8,u26-u29
s83-t213-sut1,up,t213,2n-icx,SYS-740GP-TNRT,C7470KL07P50300,10.30.51.83,10.30.50.83,3016.8,u22-u25
s84-t213-tg1,up,t213,2n-icx,SYS-740GP-TNRT,C7470KL03P50187,10.30.51.84,10.30.50.84,3016.8,u18-u21
s85-t214-sut1,up,t214,2n-icx,SYS-740GP-TNRT,C7470KK33P50219,10.30.51.85,10.30.50.85,3016.8,u14-u17
s86-t214-tg1,up,t214,2n-icx,SYS-740GP-TNRT,C7470KL07P50312,10.30.51.86,10.30.50.86,3016.8,u10-u13
s87-t215-sut1,up,t215,2n-icx,SYS-740GP-TNRT,C7470KL03P50171,10.30.51.87,10.30.50.87,3016.8,u6-u9
s88-t215-tg1,up,t215,2n-icx,SYS-740GP-TNRT,C7470KL07P50301,10.30.51.88,10.30.50.88,3016.8,u2-u5

#### Rack YUL1-9 (3016.9)
name,oper-status,testbed-id,role,model,s/n,mgmt-ip4,ipmi-ip4,rackid,rackunit
mtl1-5-lb4m,up,switch,uplink,?,?,?,?,3016.9,u47,?,?
s11-t31-sut1,up,t31,3n-skx,SYS-7049GP-TRT,C7470KH06A20037,10.30.51.46,10.30.50.43,3016.9,u42-u45
s12-t31-sut2,up,t31,3n-skx,SYS-7049GP-TRT,C7470KH06A20018,10.30.51.47,10.30.50.44,3016.9,u38-u41
s13-t31-tg1,up,t31,3n-skx,SYS-7049GP-TRT,C7470KH06A20043,10.30.51.48,10.30.50.45,3016.9,u34-u37
s14-t32-sut1,up,t31,3n-skx,SYS-7049GP-TRT,C7470KH06A20075,10.30.51.58,10.30.50.55,3016.9,u30-u33
s15-t32-sut2,up,t31,3n-skx,SYS-7049GP-TRT,C7470KH06A20010,10.30.51.59,10.30.50.56,3016.9,u26-u29
s16-t32-tg1,up,t31,3n-skx,SYS-7049GP-TRT,C7470KH06A20047,10.30.51.60,10.30.50.57,3016.9,u22-u25
s25-t25-sut1,down,t25,2n-p1,SYS-7049GP-TRT,C7470KH06A20022,10.30.51.61,10.30.50.58,3016.9,u18-u21
s19-t33t211-tg1,up,t33t211,3n-tsh/2n-tx2,SYS-7049GP-TRT,C7470KH06A20056,10.30.51.49,10.30.50.46,3016.9,u14-u17
s27-t211-sut1,up,t211,2n-tx2,ThunderX2-9975,K61186073100003,10.30.51.69,10.30.50.69,3016.9,u13
s18-t33-sut2,up,t33,3n-tsh,HUAWEI-TAISHAN-2280,N/A,10.30.51.37,10.30.50.37,3016.9,u11-u12
s17-t33-sut1,up,t33,3n-tsh,HUAWEI-TAISHAN-2280,N/A,10.30.51.36,10.30.50.36,3016.9,u9-u10
s79-t39t310-tg1,in-transit,t39t310,tbd,SYS-740GP-TNRT,???,10.30.51.89,10.30.50.89,3016.9,u5-u8

#### Rack YUL1-10 (3016.10)

name,oper-status,testbed-id,role,model,s/n,mgmt-ip4,ipmi-ip4,rackid,rackunit
yul1-10-lb4m,up,switch,uplink,?,?,?,?,3016.10,u47,?,?
s2-t12-sut1,up,t12,1n-skx,SYS-7049GP-TRT,C7470KH06A20119,10.30.51.51,10.30.50.48,3016.10,u42-u45
s1-t11-sut1,up,t11,1n-skx,SYS-7049GP-TRT,C7470KH06A20154,10.30.51.50,10.30.50.47,3016.10,u38-u41
s3-t21-sut1,up,t21,2n-skx,SYS-7049GP-TRT,C7470KH06A20167,10.30.51.44,10.30.50.41,3016.10,u34-u37
s4-t21-tg1,up,t21,2n-skx,SYS-7049GP-TRT,C7470KH06A20158,10.30.51.45,10.30.50.42,3016.10,u30-u33
s5-t22-sut1,up,t22,2n-skx,SYS-7049GP-TRT,N/A,10.30.51.52,10.30.50.49,3016.10,u26-u29
s6-t22-tg1,up,t22,2n-skx,SYS-7049GP-TRT,N/A,10.30.51.53,10.30.50.50,3016.10,u22-u25
s7-t23-sut1,up,t23,2n-skx,SYS-7049GP-TRT,N/A,10.30.51.54,10.30.50.51,3016.10,u18-u21
s8-t23-tg1,up,t23,2n-skx,SYS-7049GP-TRT,C7470KH06A20035,10.30.51.55,10.30.50.52,3016.10,u14-u17
s93-t39-sut1,up,t39,3n-snr,?,?,10.30.51.93,10.30.50.93,3016.10,u10-u13
s94-t39-sut2,up,t39,3n-snr,?,?,10.30.51.94,10.30.50.94,3016.10,u6-u9
s89-t39t310-tg1,up,t39,3n-snr,?,?,10.30.51.89,10.30.50.89,3016.10,u2-u5

#### Rack YUL1-11 (3016.11)

name,oper-status,testbed-id,role,model,s/n,mgmt-ip4,ipmi-ip4,rackid,rackunit
yul1-11-lb6m,up,switch,arm-uplink,?,?,?,?,3016.11,u48
yul1-11-lf-tor-switch,up,switch,uplink,?,?,?,?,3016.11,u47
mtl1-6-7050QX-32,up,switch,uplink,?,?,?,?,3016.11,u46
fdio-marvell-dev,up,N/A,dev,ThunderX-88XX,N/A,10.30.51.38,10.30.50.38,3016.11,u45
s56-t14-sut1,up,t14,1n-tx2,ThunderX2-9980,N/A,10.30.51.71,10.30.50.71,3016.11,u41-u42
s20-nomad,up,nomad-cluster1,nomad-client,UCSC-C240-M4SX,FCH1950V1FQ,10.30.51.20,10.30.50.20,3016.11,u39-u40
s22-nomad,up,nomad-cluster1,nomad-client,UCSC-C240-M4SX,FCH2013V0HZ,10.30.51.22,10.30.50.22,3016.11,u37-u38
s21-nomad,up,nomad-cluster1,nomad-client,UCSC-C240-M4SX,FCH2013V0J2,10.30.51.21,10.30.50.21,3016.11,u35-u36
s78-t38-sut1,up,t38,3n-icx,SYS-740GP-TNRT,C7470KL03P50450,10.30.51.78,10.30.50.78,3016.11,u31-u34
s79-t38-sut2,up,t38,3n-icx,SYS-740GP-TNRT,C7470KL07P50297,10.30.51.79,10.30.50.79,3016.11,u27-u30
s80-t38-tg1,up,t38,3n-icx,SYS-740GP-TNRT,C7470KL03P50454,10.30.51.80,10.30.50.80,3016.11,u23-u26
s16-nomad,up,nomad-cluster1,nomad-client,UCSC-C240-M4SX,FCH1950V1FN,10.30.51.16,10.30.50.16,3016.11,u19-u20
s17-nomad,up,nomad-cluster1,nomad-client,UCSC-C240-M4SX,FCH1950V1H5,10.30.51.17,10.30.50.17,3016.11,u17-u18
s18-nomad,up,nomad-cluster1,nomad-client,UCSC-C240-M4SX,FCH1950V1FS,10.30.51.18,10.30.50.18,3016.11,u15-u16
s19-nomad,up,nomad-cluster1,nomad-client,UCSC-C240-M4SX,FCH1950V1FL,10.30.51.19,10.30.50.19,3016.11,u13-u14
s55-t13-sut1,up,t13,1n-tx2,ThunderX2-9980,N/A,10.30.51.70,10.30.50.70,3016.11,u11-u12
s62-t34-sut1,up,t34,3n-alt,WIWYNN,04000059N0SC,10.30.51.72,10.30.50.72,3016.11,u9-u10
s63-t34-sut2,up,t34,3n-alt,WIWYNN,0390003EN0SC,10.30.51.73,10.30.50.73,3016.11,u7-u8
s64-t34-tg1,up,t34,3n-alt,SYS-740GP-TNRT,C7470KK40P50249,10.30.51.74,10.30.50.74,3016.11,u3-u6

#### Rack YUL1-12 (3016.12)

name,oper-status,testbed-id,role,model,s/n,mgmt-ip4,ipmi-ip4,rackid,rackunit
yul1-12-lb4m,up,switch,uplink,?,?,?,?,3016.12,u47
s31-t35-sut2/dnv3,up,t35,3n-dnv,SYS-E300-9A,CE300AG39040898,10.32.8.13,10.30.55.13,3016.12,u45
s30-t35-sut1/dnv2,up,t35,3n-dnv,SYS-E300-9A,CE300AG39040866,10.32.8.12,10.30.55.12,3016.12,u44
s29-t26-sut1/dnv1,up,t26,2n-dnv,SYS-E300-9A,CE300AG39040897,10.32.8.11,10.30.55.11,3016.12,u43
s28-t26t35-tg1,up,t26t35,2n/3n-dnv,SYS-7049GP-TRT,C7470KH06A20137,10.32.8.10,10.30.55.10,3016.12,u39-u42
s91-nomad,up,nomad-cluster1,nomad-client,R152-P30-00,GLG4P9912A0016,10.30.51.91,10.30.50.91,3016.12,u36
s92-nomad,up,nomad-cluster1,nomad-client,R152-P30-00,GLG4P9912A0004,10.30.51.92,10.30.50.92,3016.12,u35
s23-nomad,up,nomad-cluster1,nomad-server,SYS-1029P-WTRT,C1160LI12NM0256,10.30.51.23,10.30.51.23,3016.12,u34
s24-nomad,up,nomad-cluster1,nomad-server,SYS-1029P-WTRT,C1160LI12NM0241,10.30.51.24,10.30.51.24,3016.12,u33
s25-nomad,up,nomad-cluster1,nomad-server,SYS-1029P-WTRT,C1160LI12NM0540,10.30.51.25,10.30.51.25,3016.12,u32
s61-t210-tg1,up,t210,2n-zn2,AS-1014S-WTRT,C8150LI50NS2689,10.32.8.25,10.30.55.25,3016.12,u31
s60-t210-sut1,up,t210,2n-zn2,AS-1114S-WTRT,N/A,10.32.8.24,10.30.55.24,3016.12,u30
s26-nomad,up,nomad-cluster1,nomad-server,SYS-7049GP-TRT,C7470KH37A30505,10.30.51.26,10.30.51.26,3016.12,u26-u29
s33-t27-sut1,up,t27,2n-clx,SYS-7049GP-TRT,C7470KH37A30567,10.32.8.18,10.30.55.18,3016.12,u22-u25
s34-t27-tg1,up,t27,2n-clx,SYS-7049GP-TRT,C7470KH37A30565,10.32.8.19,10.30.55.19,3016.12,u18-u21
s35-t28-sut1,up,t28,2n-clx,SYS-7049GP-TRT,C7470KH37A30509,10.32.8.20,10.30.55.20,3016.12,u14-u17
s36-t28-tg1,up,t28,2n-clx,SYS-7049GP-TRT,C7470KH37A30511,10.32.8.21,10.30.55.21,3016.12,u10-u13
s37-t29-sut1,up,t29,2n-clx,SYS-7049GP-TRT,C7470KH37A30566,10.32.8.22,10.30.55.22,3016.12,u6-u9
s38-t29-tg1,up,t29,2n-clx,SYS-7049GP-TRT,C7470KH37A30506,10.32.8.23,10.30.55.23,3016.12,u2-u5