aboutsummaryrefslogtreecommitdiffstats
path: root/tests/func/l2bd/eth2p-eth-l2bdbasemacstc-eth-2vhost-1vm-func.robot
blob: 88d3260e1e6529f17da97976cb315c35b9d74a3a (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
# Copyright (c) 2016 Cisco and/or its affiliates.
# Licensed under the Apache License, Version 2.0 (the "License");
# you may not use this file except in compliance with the License.
# You may obtain a copy of the License at:
#
#     http://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS,
# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
# See the License for the specific language governing permissions and
# limitations under the License.

*** Settings ***
| Resource | resources/libraries/robot/default.robot
| Resource | resources/libraries/robot/bridge_domain.robot
| Resource | resources/libraries/robot/testing_path.robot
| Resource | resources/libraries/robot/qemu.robot
| Library  | resources.libraries.python.Trace
| Force Tags | 3_NODE_DOUBLE_LINK_TOPO | HW_ENV | VM_ENV | VPP_VM_ENV
| Test Setup | Set up functional test
| Test Teardown | Tear down functional test
| Documentation | *L2 bridge-domain test cases*
| ...
| ... | *[Top] Network Topologies:* TG=DUT=VM 3-node topology with VM
| ... | and double parallel links.
| ... | *[Enc] Packet Encapsulations:* Eth-IPv4-ICMPv4 for L2 switching of
| ... | IPv4; Eth-IPv6-ICMPv6 for L2 switching of IPv6 use. Both apply
| ... | to all links.
| ... | *[Cfg] DUT configuration:* DUT1 is configured with two L2 bridge-domains
| ... | (L2BD) switching combined with static MACs.
| ... | *[Ver] TG verification:* Test ICMPv4 (or ICMPv6) Echo Request packets
| ... | are sent in both directions by TG on links to DUT1 via VM; on
| ... | receive TG verifies packets for correctness and their IPv4 (IPv6)
| ... | src-addr, dst-addr and MAC addresses.
| ... | *[Ref] Applicable standard specifications:*

*** Variables ***
| ${bd_id1}= | 1
| ${bd_id2}= | 2

| ${sock1}= | /tmp/sock1
| ${sock2}= | /tmp/sock2

*** Test Cases ***
| TC01: DUT with two L2BDs (static MACs) switches ICMPv4 between TG and VM links
| | [Documentation]
| | ... | [Top] TG=DUT=VM. [Enc] Eth-IPv4-ICMPv4. [Cfg] On DUT1 configure \
| | ... | two L2BDs with static MACs, each with vhost-user i/f to local VM
| | ... | and i/f to TG; configure VM to loop pkts back betwen its two
| | ... | virtio i/fs. [Ver] Make TG verify ICMPv4 Echo Req pkts are
| | ... | switched thru DUT1 and VM in both directions and are correct on
| | ... | receive. [Ref]
| | ...
| | [Teardown] | Run Keywords | Stop and clear QEMU | ${dut_node} | ${vm_node}
| | ... | AND | Tear down functional test
| | ...
| | Given Configure path in 2-node circular topology
| | ... | ${nodes['TG']} | ${nodes['DUT1']} | ${nodes['TG']}
| | And Set interfaces in 2-node circular topology up
| | When Configure vhost interfaces for L2BD forwarding | ${dut_node}
| | ...                                                     | ${sock1}
| | ...                                                     | ${sock2}
| | And Create bridge domain | ${dut_node} | ${bd_id1}
| | ...                                      | learn=${FALSE}
| | And Add interface to bridge domain | ${dut_node} | ${dut_to_tg_if1}
| | ...                                     | ${bd_id1}
| | And Add interface to bridge domain | ${dut_node} | ${vhost_if1}
| | ...                                     | ${bd_id1}
| | And Add destination port to L2FIB | ${tg_node}
| | ...                                                | ${tg_to_dut_if1}
| | ...                                                | ${dut_node}
| | ...                                                | ${dut_to_tg_if1}
| | ...                                                | ${bd_id1}
| | And Add destination port to L2FIB | ${tg_node}
| | ...                                                | ${tg_to_dut_if2}
| | ...                                                | ${dut_node}
| | ...                                                | ${vhost_if1}
| | ...                                                | ${bd_id1}
| | And Create bridge domain | ${dut_node} | ${bd_id2}
| | ...                                      | learn=${FALSE}
| | And Add interface to bridge domain | ${dut_node} | ${dut_to_tg_if2}
| | ...                                     | ${bd_id2}
| | And Add interface to bridge domain | ${dut_node} | ${vhost_if2}
| | ...                                     | ${bd_id2}
| | And Add destination port to L2FIB | ${tg_node}
| | ...                                                | ${tg_to_dut_if2}
| | ...                                                | ${dut_node}
| | ...                                                | ${dut_to_tg_if2}
| | ...                                                | ${bd_id2}
| | And Add destination port to L2FIB | ${tg_node}
| | ...                                                | ${tg_to_dut_if1}
| | ...                                                | ${dut_node}
| | ...                                                | ${vhost_if2}
| | ...                                                | ${bd_id2}
| | And Configure VM for vhost L2BD forwarding | ${dut_node} | ${sock1}
| | ...                                       | ${sock2}
| | Then Send ICMPv4 bidirectionally and verify received packets | ${tg_node} | ${tg_to_dut_if1}
| | ...                                          | ${tg_to_dut_if2}

| TC02: DUT with two L2BDs (static MACs) switches ICMPv6 between TG and VM links
| | [Documentation]
| | ... | [Top] TG=DUT=VM. [Enc] Eth-IPv6-ICMPv6. [Cfg] On DUT1 configure \
| | ... | two L2BDs with static MACs, each with vhost-user i/f to local VM
| | ... | and i/f to TG; configure VM to loop pkts back betwen its two
| | ... | virtio i/fs. [Ver] Make TG verify ICMPv6 Echo Req pkts are
| | ... | switched thru DUT1 and VM in both directions and are correct on
| | ... | receive. [Ref]
| | ...
| | [Teardown] | Run Keywords | Stop and clear QEMU | ${dut_node} | ${vm_node}
| | ... | AND | Tear down functional test
| | ...
| | Given Configure path in 2-node circular topology
| | ... | ${nodes['TG']} | ${nodes['DUT1']} | ${nodes['TG']}
| | And Set interfaces in 2-node circular topology up
| | When Configure vhost interfaces for L2BD forwarding | ${dut_node}
| | ...                                                     | ${sock1}
| | ...                                                     | ${sock2}
| | And Create bridge domain | ${dut_node} | ${bd_id1}
| | ...                                      | learn=${FALSE}
| | And Add interface to bridge domain | ${dut_node} | ${dut_to_tg_if1}
| | ...                                     | ${bd_id1}
| | And Add interface to bridge domain | ${dut_node} | ${vhost_if1}
| | ...                                     | ${bd_id1}
| | And Add destination port to L2FIB | ${tg_node}
| | ...                                                | ${tg_to_dut_if1}
| | ...                                                | ${dut_node}
| | ...                                                | ${dut_to_tg_if1}
| | ...                                                | ${bd_id1}
| | And Add destination port to L2FIB | ${tg_node}
| | ...                                                | ${tg_to_dut_if2}
| | ...                                                | ${dut_node}
| | ...                                                | ${vhost_if1}
| | ...                                                | ${bd_id1}
| | And Create bridge domain | ${dut_node} | ${bd_id2}
| | ...                                      | learn=${FALSE}
| | And Add interface to bridge domain | ${dut_node} | ${dut_to_tg_if2}
| | ...                                     | ${bd_id2}
| | And Add interface to bridge domain | ${dut_node} | ${vhost_if2}
| | ...                                     | ${bd_id2}
| | And Add destination port to L2FIB | ${tg_node}
| | ...                                                | ${tg_to_dut_if2}
| | ...                                                | ${dut_node}
| | ...                                                | ${dut_to_tg_if2}
| | ...                                                | ${bd_id2}
| | And Add destination port to L2FIB | ${tg_node}
| | ...                                                | ${tg_to_dut_if1}
| | ...                                                | ${dut_node}
| | ...                                                | ${vhost_if2}
| | ...                                                | ${bd_id2}
| | And Configure VM for vhost L2BD forwarding | ${dut_node} | ${sock1}
| | ...                                       | ${sock2}
| | Then Send ICMPv6 bidirectionally and verify received packets | ${tg_node} | ${tg_to_dut_if1}
| | ...                                          | ${tg_to_dut_if2}