1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
|
# Copyright (c) 2017 Cisco and/or its affiliates.
# Licensed under the Apache License, Version 2.0 (the "License");
# you may not use this file except in compliance with the License.
# You may obtain a copy of the License at:
#
# http://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS,
# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
# See the License for the specific language governing permissions and
# limitations under the License.
*** Settings ***
| Resource | resources/libraries/robot/performance_setup.robot
| Library | resources.libraries.python.QemuUtils
| ...
| Force Tags | 3_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | PDRCHK
| ... | NIC_Intel-X520-DA2 | DOT1Q | L2XCFWD | BASE | VHOST | VM
| ...
| Suite Setup | Set up 3-node performance topology with DUT's NIC model
| ... | L2 | Intel-X520-DA2
| Suite Teardown | Tear down 3-node performance topology
| ...
| Test Setup | Set up performance test
| Test Teardown | Tear down performance pdrchk test with vhost and VM with dpdk-testpmd
| ... | ${rate}pps | ${framesize} | ${traffic_profile}
| ... | dut1_node=${dut1} | dut1_vm_refs=${dut1_vm_refs}
| ... | dut2_node=${dut2} | dut2_vm_refs=${dut2_vm_refs}
| ...
| Documentation | *RFC2544: Packet throughput L2XC test cases with vhost*
| ...
| ... | *[Top] Network Topologies:* TG-DUT1-DUT2-TG 3-node circular topology
| ... | with single links between nodes.
| ... | *[Enc] Packet Encapsulations:* Eth-IPv4 for L2 switching of IPv4. 802.1q
| ... | tagging is applied on link between DUT1 and DUT2.
| ... | *[Cfg] DUT configuration:* DUT1 and DUT2 are configured with L2 cross-
| ... | connect. Qemu Guest is connected to VPP via
| ... | vhost-user interfaces. Guest is running DPDK testpmd interconnecting
| ... | vhost-user interfaces using 5 cores pinned to cpus 5-9 and 2048M
| ... | memory. Testpmd is using socket-mem=1024M (512x2M hugepages), 5 cores
| ... | (1 main core and 4 cores dedicated for io), forwarding mode is set to
| ... | io, rxd/txd=256, burst=64. DUT1, DUT2 are tested with 2p10GE NIC X520
| ... | Niantic by Intel.
| ... | *[Ver] TG verification:* TG verifies throughput PDR (Partial Drop
| ... | Rate) with non-zero packet loss tolerance (LT) expressed in percentage
| ... | of packets transmitted. Ref-PDR value is periodically updated acording to
| ... | formula: ref-PDR = 0.9x PDR, where PDR is found in RFC2544 long
| ... | performance tests for the same DUT configuration. Test packets are
| ... | generated by TG on links to DUTs. TG traffic profile contains two L3
| ... | flow-groups (flow-group per direction, 253 flows per flow-group) with
| ... | all packets containing Ethernet header, IPv4 header with IP protocol=61
| ... | and static payload. MAC addresses are matching MAC addresses of the
| ... | TG node interfaces.
| ... | *[Ref] Applicable standard specifications:* RFC2544.
*** Variables ***
| ${subid}= | 10
| ${tag_rewrite}= | pop-1
# Socket names
| ${sock1}= | /tmp/sock-1
| ${sock2}= | /tmp/sock-2
# Traffic profile:
| ${traffic_profile} | trex-sl-3n-ethip4-ip4src254
*** Keywords ***
| Check PDR for L2XC with vhost and VM with dpdk-testpmd
| | [Documentation]
| | ... | [Cfg] DUT runs L2XC switching config with ${wt} thread, ${wt} phy\
| | ... | core, ${rxq} receive queue per NIC port.
| | ... | [Ver] Verify ref-PDR for ${framesize} Byte frames using single trial\
| | ... | throughput test at 2x ${rate}.
| | ...
| | [Arguments] | ${framesize} | ${rate} | ${wt} | ${rxq}
| | ...
| | # Test Variables required for test and test teardown
| | Set Test Variable | ${framesize}
| | Set Test Variable | ${rate}
| | ${get_framesize}= | Get Frame Size | ${framesize}
| | ${dut1_vm_refs}= | Create Dictionary
| | ${dut2_vm_refs}= | Create Dictionary
| | Set Test Variable | ${dut1_vm_refs}
| | Set Test Variable | ${dut2_vm_refs}
| | ...
| | Given Add '${wt}' worker threads and '${rxq}' rxqueues in 3-node single-link circular topology
| | And Add PCI devices to DUTs in 3-node single link topology
| | And Run Keyword If | ${get_framesize} < ${1522}
| | ... | Add no multi seg to all DUTs
| | And Apply startup configuration on all VPP DUTs
| | When Initialize L2 xconnect with Vhost-User and VLAN in 3-node circular topology
| | ... | ${sock1} | ${sock2} | ${subid} | ${tag_rewrite}
| | ${vm1}= | And Configure guest VM with dpdk-testpmd connected via vhost-user
| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1
| | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1}
| | ${vm2}= | And Configure guest VM with dpdk-testpmd connected via vhost-user
| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1
| | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2}
| | Then Traffic should pass with partial loss | ${perf_trial_duration}
| | ... | ${rate} | ${framesize} | ${traffic_profile}
| | ... | ${perf_pdr_loss_acceptance} | ${perf_pdr_loss_acceptance_type}
*** Test Cases ***
| tc01-64B-1t1c-dot1q-l2xcbase-eth-2vhost-1vm-pdrchk
| | [Documentation]
| | ... | [Cfg] DUT runs L2XC switching config with 1 thread, 1 phy\
| | ... | core, 1 receive queue per NIC port.
| | ... | [Ver] Verify ref-PDR for 64 Byte frames using single trial\
| | ... | throughput test at 2x ${rate}.
| | ...
| | [Tags] | 64B | 1T1C | STHREAD
| | ...
| | [Template] | Check PDR for L2XC with vhost and VM with dpdk-testpmd
| | framesize=${64} | rate=1.4mpps | wt=1 | rxq=1
| tc02-1518B-1t1c-dot1q-l2xcbase-eth-2vhost-1vm-pdrchk
| | [Documentation]
| | ... | [Cfg] DUT runs L2XC switching config with 1 thread, 1 phy\
| | ... | core, 1 receive queue per NIC port.
| | ... | [Ver] Verify ref-PDR for 1518 Byte frames using single trial\
| | ... | throughput test at 2x ${rate}.
| | ...
| | [Tags] | 1518B | 1T1C | STHREAD
| | ...
| | [Template] | Check PDR for L2XC with vhost and VM with dpdk-testpmd
| | framesize=${1518} | rate=330000pps | wt=1 | rxq=1
| tc03-IMIX-1t1c-dot1q-l2xcbase-eth-2vhost-1vm-pdrchk
| | [Documentation]
| | ... | [Cfg] DUT runs L2XC switching config with 1 thread, 1 phy\
| | ... | core, 1 receive queue per NIC port.
| | ... | [Ver] Verify ref-PDR for 64 Byte frames using single trial\
| | ... | throughput test at 2x ${rate}.
| | ...
| | [Tags] | IMIX | 1T1C | STHREAD
| | ...
| | [Template] | Check PDR for L2XC with vhost and VM with dpdk-testpmd
| | framesize=IMIX_v4_1 | rate=1.0mpps | wt=1 | rxq=1
| tc04-64B-2t2c-dot1q-l2xcbase-eth-2vhost-1vm-pdrchk
| | [Documentation]
| | ... | [Cfg] DUT runs L2XC switching config with 2 threads, 2 phy\
| | ... | cores, 1 receive queue per NIC port.
| | ... | [Ver] Verify ref-PDR for 64 Byte frames using single trial\
| | ... | throughput test at 2x ${rate}.
| | ...
| | [Tags] | 64B | 2T2C | MTHREAD
| | ...
| | [Template] | Check PDR for L2XC with vhost and VM with dpdk-testpmd
| | framesize=${64} | rate=1.4mpps | wt=2 | rxq=1
| tc05-1518B-2t2c-dot1q-l2xcbase-eth-2vhost-1vm-pdrchk
| | [Documentation]
| | ... | [Cfg] DUT runs L2XC switching config with 2 threads, 2 phy\
| | ... | cores, 1 receive queue per NIC port.
| | ... | [Ver] Verify ref-PDR for 1518 Byte frames using single trial\
| | ... | throughput test at 2x ${rate}.
| | ...
| | [Tags] | 1518B | 2T2C | MTHREAD
| | ...
| | [Template] | Check PDR for L2XC with vhost and VM with dpdk-testpmd
| | framesize=${1518} | rate=0.7mpps | wt=2 | rxq=1
| tc06-IMIX-2t2c-dot1q-l2xcbase-eth-2vhost-1vm-pdrchk
| | [Documentation]
| | ... | [Cfg] DUT runs L2XC switching config with 2 threads, 2 phy\
| | ... | cores, 1 receive queue per NIC port.
| | ... | [Ver] Verify ref-PDR for 64 Byte frames using single trial\
| | ... | throughput test at 2x ${rate}.
| | ...
| | [Tags] | IMIX | 2T2C | MTHREAD
| | ...
| | [Template] | Check PDR for L2XC with vhost and VM with dpdk-testpmd
| | framesize=IMIX_v4_1 | rate=1.6mpps | wt=2 | rxq=1
| tc07-64B-4t4c-dot1q-l2xcbase-eth-2vhost-1vm-pdrchk
| | [Documentation]
| | ... | [Cfg] DUT runs L2XC switching config with 4 threads, 4 phy\
| | ... | cores, 2 receive queues per NIC port.
| | ... | [Ver] Verify ref-PDR for 64 Byte frames using single trial\
| | ... | throughput test at 2x ${rate}.
| | ...
| | [Tags] | 64B | 4T4C | MTHREAD
| | ...
| | [Template] | Check PDR for L2XC with vhost and VM with dpdk-testpmd
| | framesize=${64} | rate=4.0mpps | wt=4 | rxq=2
| tc08-1518B-4t4c-dot1q-l2xcbase-eth-2vhost-1vm-pdrchk
| | [Documentation]
| | ... | [Cfg] DUT runs L2XC switching config with 4 threads, 4 phy\
| | ... | cores, 2 receive queues per NIC port.
| | ... | [Ver] Verify ref-PDR for 1518 Byte frames using single trial\
| | ... | throughput test at 2x ${rate}.
| | ...
| | [Tags] | 1518B | 4T4C | MTHREAD
| | ...
| | [Template] | Check PDR for L2XC with vhost and VM with dpdk-testpmd
| | framesize=${1518} | rate=0.7mpps | wt=4 | rxq=2
| tc09-IMIX-4t4c-dot1q-l2xcbase-eth-2vhost-1vm-pdrchk
| | [Documentation]
| | ... | [Cfg] DUT runs L2XC switching config with 4 threads, 4 phy\
| | ... | cores, 2 receive queues per NIC port.
| | ... | [Ver] Verify ref-PDR for 64 Byte frames using single trial\
| | ... | throughput test at 2x ${rate}.
| | ...
| | [Tags] | IMIX | 4T4C | MTHREAD
| | ...
| | [Template] | Check PDR for L2XC with vhost and VM with dpdk-testpmd