parent | b8b02937b1a0ef8b02cc1dcf09e93e512d6fc234 (diff) |
flowprobe: fix clearing interface state on feature disabling
As a result of recent fixes, all currently stored flows of an interface
are deleted when the feature is being disabled for the interface. This
includes stopping the timer and freeing the flow entries for further
reuse. The problem is that meta information is not cleared in the flow
entries being deleted. For example, packet delta count will keep its
value. The next flow that gets one of these pool entries will already
have a non-zero packet count. So the counting of packets will start from
a non-zero value. And incorrect packet delta count will be exported for
that flow.
With this fix, clear meta information too when clearing interface state.
Also, update the corresponding test to cover this case.
Type: fix
Change-Id: I9a73b3958adfd1676e66b0ed50f1478920671cca
Signed-off-by: Alexander Chernavin <achernavin@netgate.com>
(cherry picked from commit dab1dfeea9fec04a9a90a82dc5d770fbff344540)
-rw-r--r-- | src/plugins/flowprobe/flowprobe.c | 3 | ||||
-rw-r--r-- | test/test_flowprobe.py | 21 |
2 files changed, 23 insertions, 1 deletions
diff --git a/src/plugins/flowprobe/flowprobe.c b/src/plugins/flowprobe/flowprobe.c index af8b8ce5218..30521b5a0ca 100644 --- a/src/plugins/flowprobe/flowprobe.c +++ b/src/plugins/flowprobe/flowprobe.c @@ -527,6 +527,9 @@ flowprobe_clear_state_if_index (u32 sw_if_index) if (e->key.rx_sw_if_index == sw_if_index || e->key.tx_sw_if_index == sw_if_index) { + e->packetcount = 0; + e->octetcount = 0; + e->prot.tcp.flags = 0; if (fm->passive_timer > 0) { tw_timer_stop_2t_1w_2048sl ( diff --git a/test/test_flowprobe.py b/test/test_flowprobe.py index 234cb3b55c7..5cc36ad305a 100644 --- a/test/test_flowprobe.py +++ b/test/test_flowprobe.py @@ -1433,8 +1433,27 @@ class DisableFP(MethodHolder): self.sleep(12, "wait for leftover ip4 flows during three passive intervals") self.collector.assert_nothing_captured() + # re-enable feature for the interface + ipfix.enable_flowprobe_feature() + + # template packet should arrive immediately + ipfix_decoder = IPFIXDecoder() + self.vapi.ipfix_flush() + templates = ipfix.verify_templates(ipfix_decoder, count=1) + + # send some ip4 packets + self.create_stream(src_if=self.pg3, dst_if=self.pg4, packets=5) + capture = self.send_packets(src_if=self.pg3, dst_if=self.pg4) + + # verify meta info - packet/octet delta + self.vapi.ipfix_flush() + cflow = self.wait_for_cflow_packet(self.collector, templates[0], timeout=8) + self.verify_cflow_data(ipfix_decoder, capture, cflow) + + self.collector.get_capture(2) + # cleanup - ipfix.disable_exporter() + ipfix.remove_vpp_config() @unittest.skipUnless(config.extended, "part of extended tests") |