diff options
author | Steven Luong <sluong@cisco.com> | 2019-03-14 09:57:09 -0700 |
---|---|---|
committer | Damjan Marion <dmarion@me.com> | 2019-03-18 11:11:50 +0000 |
commit | ee8ba6877efb916b88255821f94ef33437724f75 (patch) | |
tree | aeb507c38ba53a60791c7084f6f47d540608971f /src/plugins/vmxnet3/vmxnet3.c | |
parent | a990a2e4930014f025338d8ce186abfa12ec09ff (diff) |
vmxnet3: auto bind support
For creating the vmxnet3 interface, add the bind option to automatically bind
the pci to vfio-pci module which removes the need for manual bind. Manual bind
still works, should people prefer to go that route.
Change-Id: Ife75926f8755d754a08dd0ecff0f1de326ad5ba1
Signed-off-by: Steven Luong <sluong@cisco.com>
Diffstat (limited to 'src/plugins/vmxnet3/vmxnet3.c')
-rw-r--r-- | src/plugins/vmxnet3/vmxnet3.c | 46 |
1 files changed, 32 insertions, 14 deletions
diff --git a/src/plugins/vmxnet3/vmxnet3.c b/src/plugins/vmxnet3/vmxnet3.c index 43f9cbed793..de1002381b6 100644 --- a/src/plugins/vmxnet3/vmxnet3.c +++ b/src/plugins/vmxnet3/vmxnet3.c @@ -658,9 +658,10 @@ vmxnet3_create_if (vlib_main_t * vm, vmxnet3_create_if_args_t * args) pool_foreach (vd, vmxm->devices, ({ if (vd->pci_addr.as_u32 == args->addr.as_u32) { - args->rv = VNET_API_ERROR_INVALID_VALUE; + args->rv = VNET_API_ERROR_ADDRESS_IN_USE; args->error = - clib_error_return (error, "PCI address in use"); + clib_error_return (error, "%U: %s", format_vlib_pci_addr, + &args->addr, "pci address in use"); vlib_log (VLIB_LOG_LEVEL_ERR, vmxm->log_default, "%U: %s", format_vlib_pci_addr, &args->addr, "pci address in use"); return; @@ -668,24 +669,31 @@ vmxnet3_create_if (vlib_main_t * vm, vmxnet3_create_if_args_t * args) })); /* *INDENT-ON* */ - pool_get (vmxm->devices, vd); - vd->num_tx_queues = args->txq_num; - vd->num_rx_queues = args->rxq_num; - vd->dev_instance = vd - vmxm->devices; - vd->per_interface_next_index = ~0; - vd->pci_addr = args->addr; - - if (args->enable_elog) - vd->flags |= VMXNET3_DEVICE_F_ELOG; + if (args->bind) + { + error = vlib_pci_bind_to_uio (vm, &args->addr, (char *) "auto"); + if (error) + { + args->rv = VNET_API_ERROR_INVALID_INTERFACE; + args->error = + clib_error_return (error, "%U: %s", format_vlib_pci_addr, + &args->addr, + "error encountered on binding pci device"); + vlib_log (VLIB_LOG_LEVEL_ERR, vmxm->log_default, "%U: %s", + format_vlib_pci_addr, &args->addr, + "error encountered on binding pci devicee"); + return; + } + } if ((error = vlib_pci_device_open (vm, &args->addr, vmxnet3_pci_device_ids, &h))) { - pool_put (vmxm->devices, vd); args->rv = VNET_API_ERROR_INVALID_INTERFACE; args->error = - clib_error_return (error, "pci-addr %U", format_vlib_pci_addr, - &args->addr); + clib_error_return (error, "%U: %s", format_vlib_pci_addr, + &args->addr, + "error encountered on pci device open"); vlib_log (VLIB_LOG_LEVEL_ERR, vmxm->log_default, "%U: %s", format_vlib_pci_addr, &args->addr, "error encountered on pci device open"); @@ -696,6 +704,16 @@ vmxnet3_create_if (vlib_main_t * vm, vmxnet3_create_if_args_t * args) * Do not use vmxnet3_log_error prior to this line since the macro * references vd->pci_dev_handle */ + pool_get (vmxm->devices, vd); + vd->num_tx_queues = args->txq_num; + vd->num_rx_queues = args->rxq_num; + vd->dev_instance = vd - vmxm->devices; + vd->per_interface_next_index = ~0; + vd->pci_addr = args->addr; + + if (args->enable_elog) + vd->flags |= VMXNET3_DEVICE_F_ELOG; + vd->pci_dev_handle = h; vd->numa_node = vlib_pci_get_numa_node (vm, h); vd->num_intrs = vd->num_rx_queues + 1; // +1 for the event interrupt |