aboutsummaryrefslogtreecommitdiffstats
path: root/src/vnet
diff options
context:
space:
mode:
authorSteven <sluong@cisco.com>2017-06-30 07:15:02 -0700
committerDamjan Marion <dmarion.lists@gmail.com>2017-07-06 13:27:25 +0000
commit9d6d9894b1035eda6163d96c72b9ddbaea096f0e (patch)
tree65982dd21771d8191ec351a6e8bbcab926e8a154 /src/vnet
parent475674ee5aa4e130a0ac0caf08ef9d579b8604b7 (diff)
devices: show interface rx-placement displays the wrong information (VPP-894)
show interface rx-placement somtimes displays the wrong interface names. This happens when there exists subinterfaces in VPP. The problem is due to the function show_interface_rx_placement_fn is calling format_vnet_sw_if_index_name with hw_if_index instead of sw_if_index. VPP has the concept of sw_if_index and hw_if_index. Each serves a different purpose. When there is no subinterfaces, both hw_if_index and sw_if_index may happen to have the same value. But don't count on it. When the API calls for sw_if_index, we must pass the sw_if_index although the hw_if_index has the same type which the compiler does not catch. Passing hw_if_index for an API which requires sw_if_index may have an unpredictable result such as described in the VPP-894 and sometimes it may even crash if the particular index does not exist. Change-Id: I76c4834f79b88a1c20684fcba64f14b2da142d77 Signed-off-by: Steven <sluong@cisco.com> (cherry picked from commit bafa4d048439fdbcc0bd577e43a2784d1b89bfc5)
Diffstat (limited to 'src/vnet')
-rw-r--r--src/vnet/interface_cli.c4
1 files changed, 3 insertions, 1 deletions
diff --git a/src/vnet/interface_cli.c b/src/vnet/interface_cli.c
index bf2873acbe9..fe7ae38f7cd 100644
--- a/src/vnet/interface_cli.c
+++ b/src/vnet/interface_cli.c
@@ -1339,8 +1339,10 @@ show_interface_rx_placement_fn (vlib_main_t * vm, unformat_input_t * input,
vec_foreach (dq, rt->devices_and_queues)
{
+ vnet_hw_interface_t *hi = vnet_get_hw_interface (vnm,
+ dq->hw_if_index);
s = format (s, " %U queue %u (%U)\n",
- format_vnet_sw_if_index_name, vnm, dq->hw_if_index,
+ format_vnet_sw_if_index_name, vnm, hi->sw_if_index,
dq->queue_id,
format_vnet_hw_interface_rx_mode, dq->mode);
}