diff options
author | Neale Ranns <nranns@cisco.com> | 2016-10-07 15:14:33 +0100 |
---|---|---|
committer | Damjan Marion <dmarion.lists@gmail.com> | 2016-10-10 18:58:22 +0000 |
commit | 33a7dd5ad9a3d3ecd9bd8472ca20ee5f82ae9542 (patch) | |
tree | 039a067b44b25df78a3aa2d14d4dc558c79dc9d7 /test/test_l2bd.py | |
parent | bfe737a1b29afea2e10248b8c9fa800148fbd573 (diff) |
FIB2.0: memory leaks during load-balance update (VPP-475)
some other fixes and enhancemets to address failures in the IPv6 Scale testing:
- The rate at which VPP sends ARP/ND requests, 1 per-millisecond, is too high. This is reduced to 1 every 10 ms. probably still too high.
- If an ARP/ND response is received that does not contain a change to the known MAC address, no further processing is done.
- Added stats to get info about the async FIB walks.
- When walking FIB entries and performing a load-balance update, it is not necessary to re-insert the LB in the forwarding table.
Change-Id: Ifd47e4bdbce94495f44aaf1b78e7d1395ed870d1
Signed-off-by: Neale Ranns <nranns@cisco.com>
Diffstat (limited to 'test/test_l2bd.py')
0 files changed, 0 insertions, 0 deletions