summaryrefslogtreecommitdiffstats
path: root/test/test_vcl.py
diff options
context:
space:
mode:
authorDave Wallace <dwallacelf@gmail.com>2018-03-02 13:19:30 -0500
committerKeith Burns <alagalah@gmail.com>2018-03-02 19:22:53 +0000
commitd85075e6e43097e536ab0c8ce9290a81d5a40f81 (patch)
tree43d1f25d62addc2a41de4faaf7978c9636a55d72 /test/test_vcl.py
parent05e4f9b3775b3549535e931042b5539de91a2daa (diff)
make test: VCL extended test cases
- Add VCL cut thru uni-direction test over multiple sockets - Add VCL cut thru bi-direction test over multiple sockets - Add LDP cut thru uni-directional test over multiple sockets - Add LDP cut thru bi-directional test over multiple sockets - Add VCL thru host stack uni-direction test over multiple sockets - Add VCL thru host stack bi-direction test over multiple sockets - Add LDP thru host stack uni-directional test over multiple sockets - Add LDP thru host stack bi-directional test over multiple sockets - Fix validateResults to ensure worker_server process is killed if it still exists after running the test. Change-Id: I77ea9acef172667558dbcec23af1e4c72b29f376 Signed-off-by: Dave Wallace <dwallacelf@gmail.com>
Diffstat (limited to 'test/test_vcl.py')
-rw-r--r--test/test_vcl.py210
1 files changed, 194 insertions, 16 deletions
diff --git a/test/test_vcl.py b/test/test_vcl.py
index 3e50921cddb..d5bbccd26aa 100644
--- a/test/test_vcl.py
+++ b/test/test_vcl.py
@@ -4,18 +4,15 @@
import unittest
import os
import signal
-from framework import VppTestCase, VppTestRunner, Worker
+from framework import VppTestCase, VppTestRunner, running_extended_tests, \
+ Worker
from vpp_ip_route import VppIpTable, VppIpRoute, VppRoutePath
class VclAppWorker(Worker):
""" VCL Test Application Worker """
- def __init__(self, appname, args, logger, env={}):
- var = "VPP_TEST_BUILD_DIR"
- build_dir = os.getenv(var, None)
- if build_dir is None:
- raise Exception("Environment variable `%s' not set" % var)
+ def __init__(self, build_dir, appname, args, logger, env={}):
vcl_lib_dir = "%s/vpp/.libs" % build_dir
app = "%s/%s" % (vcl_lib_dir, appname)
if not os.path.isfile(app):
@@ -30,6 +27,11 @@ class VclTestCase(VppTestCase):
""" VCL Test Class """
def __init__(self, methodName):
+ var = "VPP_TEST_BUILD_DIR"
+ self.build_dir = os.getenv(var, None)
+ if self.build_dir is None:
+ raise Exception("Environment variable `%s' not set" % var)
+ self.vppDebug = 'vpp_debug' in self.build_dir
self.server_addr = "127.0.0.1"
self.server_port = "22000"
self.timeout = 3
@@ -47,11 +49,12 @@ class VclTestCase(VppTestCase):
self.env = {'VCL_API_PREFIX': self.shm_prefix,
'VCL_APP_SCOPE_LOCAL': "true"}
- worker_server = VclAppWorker(server_app, [self.server_port],
+ worker_server = VclAppWorker(self.build_dir, server_app,
+ [self.server_port],
self.logger, self.env)
worker_server.start()
self.sleep(0.2)
- worker_client = VclAppWorker(client_app, client_args,
+ worker_client = VclAppWorker(self.build_dir, client_app, client_args,
self.logger, self.env)
worker_client.start()
worker_client.join(self.timeout)
@@ -106,14 +109,15 @@ class VclTestCase(VppTestCase):
'VCL_APP_NAMESPACE_ID': "0",
'VCL_APP_NAMESPACE_SECRET': "1234"}
- worker_server = VclAppWorker(server_app, [self.server_port],
+ worker_server = VclAppWorker(self.build_dir, server_app,
+ [self.server_port],
self.logger, self.env)
worker_server.start()
self.sleep(0.2)
self.env.update({'VCL_APP_NAMESPACE_ID': "1",
'VCL_APP_NAMESPACE_SECRET': "5678"})
- worker_client = VclAppWorker(client_app, client_args,
+ worker_client = VclAppWorker(self.build_dir, client_app, client_args,
self.logger, self.env)
worker_client.start()
worker_client.join(self.timeout)
@@ -121,13 +125,19 @@ class VclTestCase(VppTestCase):
self.validateResults(worker_client, worker_server, self.timeout)
def validateResults(self, worker_client, worker_server, timeout):
+ if os.path.isdir('/proc/{}'.format(worker_server.process.pid)):
+ self.logger.info("Killing server worker process (pid %d)" %
+ worker_server.process.pid)
+ os.killpg(os.getpgid(worker_server.process.pid), signal.SIGTERM)
+ worker_server.join()
self.logger.info("Client worker result is `%s'" % worker_client.result)
error = False
if worker_client.result is None:
try:
error = True
self.logger.error(
- "Timeout (%ss)! Killing client worker process" % timeout)
+ "Timeout: %ss! Killing client worker process (pid %d)" %
+ (timeout, worker_client.process.pid))
os.killpg(os.getpgid(worker_client.process.pid),
signal.SIGTERM)
worker_client.join()
@@ -136,8 +146,6 @@ class VclTestCase(VppTestCase):
"Couldn't kill client worker process")
raise
if error:
- os.killpg(os.getpgid(worker_server.process.pid), signal.SIGTERM)
- worker_server.join()
raise Exception(
"Timeout! Client worker did not finish in %ss" % timeout)
self.assert_equal(worker_client.result, 0, "Binary test return code")
@@ -152,6 +160,14 @@ class VCLCutThruTestCase(VclTestCase):
self.cut_thru_setup()
self.client_echo_test_args = [self.server_addr, self.server_port,
"-E", self.echo_phrase, "-X"]
+ self.client_uni_dir_nsock_timeout = 60
+ self.client_uni_dir_nsock_test_args = [self.server_addr,
+ self.server_port,
+ "-I", "5", "-U", "-X"]
+ self.client_bi_dir_nsock_timeout = 120
+ self.client_bi_dir_nsock_test_args = [self.server_addr,
+ self.server_port,
+ "-I", "2", "-B", "-X"]
def tearDown(self):
self.cut_thru_tear_down()
@@ -164,12 +180,44 @@ class VCLCutThruTestCase(VclTestCase):
self.cut_thru_test("sock_test_server", "sock_test_client",
self.client_echo_test_args)
+ @unittest.skipUnless(running_extended_tests(), "part of extended tests")
+ def test_ldp_cut_thru_uni_dir_nsock(self):
+ """ run LDP cut thru uni-directional (multiple sockets) test """
+
+ self.timeout = self.client_uni_dir_nsock_timeout
+ self.cut_thru_test("sock_test_server", "sock_test_client",
+ self.client_uni_dir_nsock_test_args)
+
+ @unittest.skipUnless(running_extended_tests(), "part of extended tests")
+ def test_ldp_cut_thru_bi_dir_nsock(self):
+ """ run LDP cut thru bi-directional (multiple sockets) test """
+
+ self.timeout = self.client_bi_dir_nsock_timeout
+ self.cut_thru_test("sock_test_server", "sock_test_client",
+ self.client_bi_dir_nsock_test_args)
+
def test_vcl_cut_thru_echo(self):
""" run VCL cut thru echo test """
self.cut_thru_test("vcl_test_server", "vcl_test_client",
self.client_echo_test_args)
+ @unittest.skipUnless(running_extended_tests(), "part of extended tests")
+ def test_vcl_cut_thru_uni_dir_nsock(self):
+ """ run VCL cut thru uni-directional (multiple sockets) test """
+
+ self.timeout = self.client_uni_dir_nsock_timeout
+ self.cut_thru_test("vcl_test_server", "vcl_test_client",
+ self.client_uni_dir_nsock_test_args)
+
+ @unittest.skipUnless(running_extended_tests(), "part of extended tests")
+ def test_vcl_cut_thru_bi_dir_nsock(self):
+ """ run VCL cut thru bi-directional (multiple sockets) test """
+
+ self.timeout = self.client_bi_dir_nsock_timeout
+ self.cut_thru_test("vcl_test_server", "vcl_test_client",
+ self.client_bi_dir_nsock_test_args)
+
class VCLThruHostStackTestCase(VclTestCase):
""" VCL Thru Host Stack Tests """
@@ -178,7 +226,8 @@ class VCLThruHostStackTestCase(VclTestCase):
super(VCLThruHostStackTestCase, self).setUp()
self.thru_host_stack_setup()
- self.client_echo_test_args = [self.loop0.local_ip4, self.server_port,
+ self.client_echo_test_args = [self.loop0.local_ip4,
+ self.server_port,
"-E", self.echo_phrase, "-X"]
def tearDown(self):
@@ -191,16 +240,145 @@ class VCLThruHostStackTestCase(VclTestCase):
self.thru_host_stack_test("sock_test_server", "sock_test_client",
self.client_echo_test_args)
- # TBD: Remove this when VPP crash is fixed.
+ # TBD: Remove these when VPP thru host teardown config bug is fixed.
self.thru_host_stack_test("vcl_test_server", "vcl_test_client",
self.client_echo_test_args)
def test_vcl_thru_host_stack_echo(self):
""" run VCL thru host stack echo test """
- # TBD: Enable this when VPP crash is fixed.
+ # TBD: Enable this when VPP thru host teardown config bug is fixed.
# self.thru_host_stack_test("vcl_test_server", "vcl_test_client",
# self.client_echo_test_args)
+ # TBD: Remove VCLThruHostStackExtended*TestCase classes and move
+ # tests here when VPP thru host teardown/setup config bug
+ # is fixed.
+
+
+class VCLThruHostStackExtendedATestCase(VclTestCase):
+ """ VCL Thru Host Stack Extended Tests """
+
+ def setUp(self):
+ super(VCLThruHostStackExtendedATestCase, self).setUp()
+
+ self.thru_host_stack_setup()
+ if self.vppDebug:
+ self.client_bi_dir_nsock_timeout = 120
+ else:
+ self.client_bi_dir_nsock_timeout = 60
+ self.client_bi_dir_nsock_test_args = [self.loop0.local_ip4,
+ self.server_port,
+ "-I", "2", "-B", "-X"]
+
+ def tearDown(self):
+ self.thru_host_stack_tear_down()
+
+ super(VCLThruHostStackExtendedATestCase, self).tearDown()
+
+ @unittest.skipUnless(running_extended_tests(), "part of extended tests")
+ def test_vcl_thru_host_stack_bi_dir_nsock(self):
+ """ run VCL thru host stack bi-directional (multiple sockets) test """
+
+ self.timeout = self.client_bi_dir_nsock_timeout
+ self.thru_host_stack_test("vcl_test_server", "vcl_test_client",
+ self.client_bi_dir_nsock_test_args)
+
+
+class VCLThruHostStackExtendedBTestCase(VclTestCase):
+ """ VCL Thru Host Stack Extended Tests """
+
+ def setUp(self):
+ super(VCLThruHostStackExtendedBTestCase, self).setUp()
+
+ self.thru_host_stack_setup()
+ if self.vppDebug:
+ self.client_bi_dir_nsock_timeout = 120
+ else:
+ self.client_bi_dir_nsock_timeout = 60
+ self.client_bi_dir_nsock_test_args = [self.loop0.local_ip4,
+ self.server_port,
+ "-I", "2", "-B", "-X"]
+
+ def tearDown(self):
+ self.thru_host_stack_tear_down()
+
+ super(VCLThruHostStackExtendedBTestCase, self).tearDown()
+
+ @unittest.skipUnless(running_extended_tests(), "part of extended tests")
+ def test_ldp_thru_host_stack_bi_dir_nsock(self):
+ """ run LDP thru host stack bi-directional (multiple sockets) test """
+
+ self.timeout = self.client_bi_dir_nsock_timeout
+ self.thru_host_stack_test("sock_test_server", "sock_test_client",
+ self.client_bi_dir_nsock_test_args)
+
+
+class VCLThruHostStackExtendedCTestCase(VclTestCase):
+ """ VCL Thru Host Stack Extended Tests """
+
+ def setUp(self):
+ super(VCLThruHostStackExtendedCTestCase, self).setUp()
+
+ self.thru_host_stack_setup()
+ if self.vppDebug:
+ self.client_uni_dir_nsock_timeout = 120
+ self.numSockets = "2"
+ else:
+ self.client_uni_dir_nsock_timeout = 120
+ self.numSockets = "5"
+
+ self.client_uni_dir_nsock_test_args = [self.loop0.local_ip4,
+ self.server_port,
+ "-I", self.numSockets,
+ "-U", "-X"]
+
+ def tearDown(self):
+ self.thru_host_stack_tear_down()
+
+ super(VCLThruHostStackExtendedCTestCase, self).tearDown()
+
+ @unittest.skipUnless(running_extended_tests(), "part of extended tests")
+ def test_ldp_thru_host_stack_uni_dir_nsock(self):
+ """ run LDP thru host stack uni-directional (multiple sockets) test """
+
+ self.timeout = self.client_uni_dir_nsock_timeout
+ self.thru_host_stack_test("sock_test_server", "sock_test_client",
+ self.client_uni_dir_nsock_test_args)
+
+
+class VCLThruHostStackExtendedDTestCase(VclTestCase):
+ """ VCL Thru Host Stack Extended Tests """
+
+ def setUp(self):
+ super(VCLThruHostStackExtendedDTestCase, self).setUp()
+
+ self.thru_host_stack_setup()
+ if self.vppDebug:
+ self.client_uni_dir_nsock_timeout = 120
+ self.numSockets = "2"
+ else:
+ self.client_uni_dir_nsock_timeout = 120
+ self.numSockets = "5"
+
+ self.client_uni_dir_nsock_test_args = [self.loop0.local_ip4,
+ self.server_port,
+ "-I", self.numSockets,
+ "-U", "-X"]
+
+ def tearDown(self):
+ self.thru_host_stack_tear_down()
+
+ super(VCLThruHostStackExtendedDTestCase, self).tearDown()
+
+ @unittest.skipUnless(running_extended_tests(), "part of extended tests")
+ def test_vcl_thru_host_stack_uni_dir_nsock(self):
+ """ run VCL thru host stack uni-directional (multiple sockets) test """
+
+ self.timeout = self.client_uni_dir_nsock_timeout
+ self.thru_host_stack_test("vcl_test_server", "vcl_test_client",
+ self.client_uni_dir_nsock_test_args)
+
+
if __name__ == '__main__':
unittest.main(testRunner=VppTestRunner)