Age | Commit message (Collapse) | Author | Files | Lines |
|
Type: improvement
Change-Id: I0cafe08d21e02094dda203c5eb60601b5953425d
Signed-off-by: Florin Coras <fcoras@cisco.com>
|
|
For bond interface, we set hardware link state to up initially when
admin state is set to up. Thereafter, if we toggle the admin state to
down and up, we require at least one active member in the bond prior
to bringing up the hardware state which is inconsistent. The fix is to
remove the unnecessary condition.
This is a rework of the original proposed patch which is more complex
and could be tricky to get it right
https://gerrit.fd.io/r/c/vpp/+/27141
Type: fix
Signed-off-by: Steven Luong <sluong@cisco.com>
Change-Id: I65f4fee55299b5b4d5645f6e05e1be15b46b73cd
|
|
Update the documents for the VPP tutorial.
Type: fix
Signed-off-by: John DeNisco <jdenisco@cisco.com>
Change-Id: I62d0641ff0af7b07a26b4379f19cbdaf285537d7
|
|
Type: improvement
Signed-off-by: Klement Sekera <ksekera@cisco.com>
Change-Id: Ia77ce41a8f1a032c5e027c4bb47347752cfda0a9
|
|
Type: fix
Change-Id: Idb6f82e08b29e3805ed2133acb5fd7226148f672
Signed-off-by: Benoît Ganne <bganne@cisco.com>
|
|
Type: fix
Signed-off-by: Florin Coras <fcoras@cisco.com>
Change-Id: Ibb380eecca76ed9c00ed14c167dfcf576f943db0
|
|
Type: fix
Signed-off-by: Florin Coras <fcoras@cisco.com>
Change-Id: I6832e3f24a56e043415a32eb4072d0bfb7697251
|
|
Type: fix
Change-Id: I5f550bd6a03f47b829ef99803cb6b9ac86329450
Signed-off-by: Florin Coras <fcoras@cisco.com>
|
|
Type: fix
Change-Id: Iefe6b3a1a0a999d89ef9812fc14d31159043e60c
Signed-off-by: Florin Coras <fcoras@cisco.com>
|
|
prefix_len is parsed using '%u' format requiring an integer.
Type: fix
Change-Id: I9f31fa60e80d4f45fe456f3fd6c94f123cfc99ea
Signed-off-by: Benoît Ganne <bganne@cisco.com>
|
|
- Replace textual string slave with member except APIs.
- For APIs, mark the existing APIs as deprecated and introduce new APIs
- While introducing sw_bond_interface_dump, add the optional filter by
sw_if_index and enhance the testcases to make use of it.
Type: improvement
Signed-off-by: Steven Luong <sluong@cisco.com>
Change-Id: Ib6626c514e45350308aeeda0decb70f3aba2f63e
|
|
Type: fix
Change-Id: Ie3d24b3df02d08fbb74d97f4e5ab0d79c35b0c0d
Signed-off-by: Filip Tehlar <ftehlar@cisco.com>
|
|
Type: improvement
Signed-off-by: Klement Sekera <ksekera@cisco.com>
Change-Id: I83f44711264376389989152666f3c71216146bdd
|
|
This fixes TCP connection cleanup crash when TCP debugging is enabled.
It could happen if session_stream_accept() returned an error.
Type: fix
Signed-off-by: Ivan Shvedunov <ivan4th@gmail.com>
Change-Id: I0df08969d82bb0f44def81b9e47195bd15502831
|
|
Type: fix
Change-Id: I8f776ce10ee8c29689db5ceef70df42dfb6b747c
Signed-off-by: Benoît Ganne <bganne@cisco.com>
|
|
Type: fix
Change-Id: Iab99bc1f6c309fae6eaa714b484274fe7072a4cb
Signed-off-by: Benoît Ganne <bganne@cisco.com>
|
|
Type: fix
Change-Id: Iab512ba8c72c9e20aeba2d4265276bcabf095d46
Signed-off-by: Benoît Ganne <bganne@cisco.com>
|
|
Type: fix
Signed-off-by: Ivan Shvedunov <ivan4th@gmail.com>
Signed-off-by: Florin Coras <fcoras@cisco.com>
Change-Id: Id20f693a5acdee74ab534e9964418973537b977f
|
|
The elog track, if enabled, must be initalized before synack is sent.
Type: fix
Signed-off-by: Ivan Shvedunov <ivan4th@gmail.com>
Signed-off-by: Florin Coras <fcoras@cisco.com>
Change-Id: I0c585f466c9a5cbc13af971ae4951b93f9913c5f
|
|
Type: feature
Ticket: VPP-1897
Change-Id: I0245aceeb344efd29b1f9217c35889a8bbe1f744
Signed-off-by: jan_cavojsky <Jan.Cavojsky@pantheon.tech>
Signed-off-by: Filip Tehlar <ftehlar@cisco.com>
|
|
create geneve tunnel local 10.10.10.10 remote 10.10.10.9 vni 48 decap-next node ethernet-input l3-mode
set interface ip address geneve_tunnel0 11.11.11.12/24
Type: feature
Change-Id: I579ce879553d72a2e8048e33d0c0122674996b81
Signed-off-by: Ole Troan <ot@cisco.com>
|
|
By default, VPP automatically assignes for each tunnel
next available QAT device by order dev_id-que-pair.
In most cases we have more than one device and it can
greatly increase ipsec perfomance without any actions
with configuration from user if we use all the
devices first and first que-pairs
Type: feature
Signed-off-by: Vladimir Ratnikov <vratnikov@netgate.com>
Change-Id: Iac9fe74768775459e22f69bb3706b542090a9375
|
|
Copy only exactly the data provided by the user even when it is not a
4-bytes multiple.
Type: fix
Change-Id: I2ef987c37e58523a38b46b09227529db2c26aa55
Signed-off-by: Benoît Ganne <bganne@cisco.com>
|
|
"ipv4"/"ipv6" option is not supported in acl_add_replace and
macip_acl_add_replace vat api.
Update its help message per actual api usage.
Type: fix
Change-Id: I8d34fac5f98bd78a46a5e98df05cd35182988dd8
Signed-off-by: Lijian Zhang <Lijian.Zhang@arm.com>
Reviewed-by: Jieqiang Wang <Jieqiang.Wang@arm.com>
Reviewed-by: Govindarajan Mohandoss <Govindarajan.Mohandoss@arm.com>
|
|
Type: fix
Signed-off-by: Florin Coras <fcoras@cisco.com>
Change-Id: I96673c984077876e69b18b4126b55e70dc07b50f
|
|
Type: improvement
Change-Id: Ia63d1d7de273967ab7725d83634c0b6dd481c6c0
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
Also removes delack timer and reuses the u32 for the pending timers
list.
Type: fix
Ticket: VPP-1923
Signed-off-by: Florin Coras <fcoras@cisco.com>
Change-Id: I4edbb72d5b2aa5e14f87659f49e675af1e834aca
|
|
Change the port number selection for new NAT sessions so that it
matches how the thread index is calculated from the port number for
out2in packets. Before this change there was a problem when the
largest port number in the range was used, that resulted in the wrong
thread index being selected when out2in packets arrive for that
session.
Type: fix
Signed-off-by: Elias Rudberg <elias.rudberg@bahnhof.net>
Change-Id: I936c389eb0d5df6168e18e5e44754de1cdad6ad1
Signed-off-by: Klement Sekera <ksekera@cisco.com>
|
|
Type: fix
Change-Id: I3eb51ea4f6c29005b0315cf488fcabb8543dfcd1
Signed-off-by: Benoît Ganne <bganne@cisco.com>
|
|
make the change backwards compatible
Change-Id: I379691aa5972f99b2144deda4b7ef9e6ba4af67d
Type: fix
Signed-off-by: Ole Troan <ot@cisco.com>
|
|
Type: improvement
Change-Id: I991e32d531719693c387db4ef93d04d4b562789d
Signed-off-by: Mohsin Kazmi <sykazmi@cisco.com>
|
|
Type: feature
Signed-off-by: Neale Ranns <nranns@cisco.com>
Change-Id: Ie8bd50df163aea2798e9f9d35a13dcadc4a4a4b2
|
|
Do not access data structures based on uninitialized key->alg.
Type: fix
Fixes: f539578bac8b64886b57c460c9d74273e6613f8b
Change-Id: I6bfb7e7a51af2c131b8bdf3bca6a38fcf1094760
Signed-off-by: Benoît Ganne <bganne@cisco.com>
|
|
Free the existing vectors prior to losing them.
Type: fix
Ticket: VPPSUPP-94
Signed-off-by: Steven Luong <sluong@cisco.com>
Change-Id: Ic15f1fbc7a0c6c348065fc9759ee5d5c43013b91
Signed-off-by: Ole Troan <ot@cisco.com>
|
|
Type: refactor
Change-Id: I6b8dc68e5d4a452776fbaf5a69fbd7f53a8abb75
Signed-off-by: Filip Tehlar <ftehlar@cisco.com>
|
|
Type: fix
Signed-off-by: Chinmaya Agarwal <chinmaya.agarwal@hsc.com>
Change-Id: Id43ab583f444e4487085fc686d5faed4858b2e97
|
|
Add a callback to clear the per-client packet trace buffer cache.
Save the packet trace dump pg setup script.
Type: improvement
Signed-off-by: Dave Barach <dave@barachs.net>
Change-Id: I252be911b5f937ece0da5dca152263ece3d52963
|
|
Type: fix
Change-Id: Iae9e84d4297acd54c909d3a8a39adafcd86b0a91
Signed-off-by: Benoît Ganne <bganne@cisco.com>
|
|
As requested by Neale, mark the ABF API as in-progress
Change-Id: I109a32fa54b1f2a882695d9fd71b235fa46bc6f3
Type: fix
Signed-off-by: Andrew Yourtchenko <ayourtch@gmail.com>
|
|
As per request from Neale, mark the GBP plugin APIs as in-progress.
Type: fix
Change-Id: I679943edcfff0742ee32c45cd8f97f482c353b9f
Signed-off-by: Andrew Yourtchenko <ayourtch@gmail.com>
|
|
As requested by Neale, mark the API as in-progress.
Change-Id: Id92cad65c66435e179583507f077816e09e4205b
Type: fix
Signed-off-by: Andrew Yourtchenko <ayourtch@gmail.com>
|
|
In pppoe_cp_node.c, node->errors[error0] was accessed without
node->errors being initialized.
Found with AFL + ASAN.
Type: fix
Signed-off-by: TimotheeChauvin <timchauv@cisco.com>
Change-Id: Ide8a60021b2d47b5e2fce7062d8f12c7f4d225f7
|
|
Callbacks for monitoring and performance measurement:
- Add new callback list type, with context
- Add callbacks for API, CLI, and barrier sync
- Modify node dispatch callback to pass plugin-specific context
- Modify perfmon plugin to keep PMC samples local to the plugin
- Include process nodes in dispatch callback
- Pass dispatch function return value to callback
Type: refactor
Signed-off-by: Tom Seidenberg <tseidenb@cisco.com>
Change-Id: I28b06c58490611e08d76ff5b01b2347ba2109b22
|
|
CID 211153
Type: fix
Signed-off-by: Chenmin Sun <chenmin.sun@intel.com>
Change-Id: Ic4d518d047c3ff36d9a7b72477c3efcb554d05bb
|
|
clang tends to force alignment of all sections when compiling for
address sanitizer, confusing VPP plugin infra.
On the contrary, GCC does not support this attribute on sections.
Selectively enable it depending upon the compiler.
Type: fix
Fixes: cea46522e79637f6ec37c03ec3fbeb87b160a378
Change-Id: I2dd6e52e70e6b4d89c101171cafc813e175ec472
Signed-off-by: Benoît Ganne <bganne@cisco.com>
|
|
- Fixes coverity issue #210160.
- Fixes the possible issue in cryptodev when input node does
not update mbuf, such as avf-input.
- Fixes GCM ESN packet incorrect tag.
- Code clean up to reduce binary size.
Type: fix
Signed-off-by: Fan Zhang <roy.fan.zhang@intel.com>
Signed-off-by: Dariusz Kazimierski <dariuszx.kazimierski@intel.com>
Signed-off-by: Piotr Kleski <piotrx.kleski@intel.com>
Change-Id: Ic05ae29855ac1f7a62e4af5831a4ed9faa8f561a
|
|
In case of vector, we must check length before trying to access element.
Also fix wrong DPDK plugin workaround.
Type: fix
Change-Id: I2ecef1c88ebef2362f48cab0d462699aa43cd4b9
Signed-off-by: Benoît Ganne <bganne@cisco.com>
|
|
Type: feature
Signed-off-by: Dave Barach <dave@barachs.net>
Change-Id: I586547508003b95eaa74e18e4a5ac6f72986822c
|
|
Provide binary API compatibility support for the "cop" APIs until vpp
21.01.
Change the deprecation date in map.api to vpp 21.01.
Type: refactor
Signed-off-by: Dave Barach <dave@barachs.net>
Change-Id: I0e60d96de4ae9ae4448f134cf257934126f3b760
|
|
- add 64-bit version
- remove byte swaps, as they are actually not needed
Type: improvement
Change-Id: Ia1efe54ee80b4ae7633b9ab36b3154c3357006d7
Signed-off-by: Damjan Marion <damarion@cisco.com>
|