Age | Commit message (Collapse) | Author | Files | Lines |
|
This patch adds support for the DPDK iAVF PMD
Type: feature
Signed-off-by: Chenmin Sun <chenmin.sun@intel.com>
Change-Id: I7bb0f621774e4c55b9b7309462e6591ce1b88fb6
|
|
DPDK provides two new APIs to retrieve information about the Tx/Rx
packet burst mode:
rte_eth_tx_burst_mode_get
rte_eth_rx_burst_mode_get
This patch leverages these two APIs to describe the tx/rx mode.
Currently, Intel X710/E810 and Mellanox Mlx5 support the new APIs.
For NICs that don't support the new APIs, still use the original way
to print their tx/rx function name
Type: refactor
Signed-off-by: Chenmin Sun <chenmin.sun@intel.com>
Change-Id: Ibe47f5debe3b3f17f462fbf9834394e22845cc08
|
|
Type: feature
Output DPDK switch information to allow finding out which DPDK ports are
associated with which DPDK representor ports.
Signed-off-by: Haggai Eran <haggai.eran@gmail.com>
Change-Id: I612cbd5a97e04787eca13423f53c7283d5945e37
|
|
Not in functional state for a long time ...
Type: refactor
Change-Id: I2cc1525a6d49518cbc94faf6afbf0d2d0d515f56
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
Type: feature
This patch adds the devargs support for dpdk device
The devargs are used as hardware-specific init args for dpdk devices
please refer to the nic guides under
$(DPDK_DIR)/doc/guides/nics/$(NIC_DRIVER).rst
Signed-off-by: Chenmin Sun <chenmin.sun@intel.com>
Change-Id: Id380d04720090bb66afe5ce09d664e5e248b8eb9
|
|
This adds support to compile the bnxt PMD that supports Broadcom's
10/25/40/50/100/200 Gbps NICs. Tested with modified DPDK driver on
x86_64 and aarch64 targets that is pending upstream acceptance, but
should compile just fine today.
Type: feature
Signed-off-by: Andy Gospodarek <gospo@broadcom.com>
Change-Id: I735a991c4cae4fa77e5605094facea54b781a1db
|
|
Extended stats are not displayed due to incorrect condition.
Type: fix
Change-Id: Ie04664e6274137462dce832bf7ee06204cd77be5
Signed-off-by: Filip Tehlar <ftehlar@cisco.com>
|
|
hardware-interfaces verbose'
Type: fix
It's time-consuming to execute 'show hardware-interfaces detail' in CSIT script.
'show hardware-interfaces' dumps SFP eeprom, via a software emulated I2C bus.
Currently 'show hardware-interfaces', 'show hardware-interfaces verbose' and
'show hardware-interfaces detail' give exactly the same output,
and they all will dump SFP eeprom.
Will move the SFP eeprom dump to 'show hardware-interfaces detail' only,
and use “show hardware-interfaces verbose” in CSIT script to save time.
Change-Id: I1a6e5a0ca5fce5b4f0b9a6eb4e9dfd76d45b2487
Signed-off-by: Lijian Zhang <Lijian.Zhang@arm.com>
|
|
.. and remove helper stat struct for keeping last cleared stats.
This is not needed anymore as dpdk lib provides rte_eth_dev_reset().
Change-Id: I78076e689aac7ca70836ce688dfa8e704f64cd84
Signed-off-by: Filip Tehlar <ftehlar@cisco.com>
|
|
Change-Id: I421192e1921d4c9c5486a6dcca745582aebf4e3e
Signed-off-by: Filip Tehlar <ftehlar@cisco.com>
|
|
We have native implementation and we should not maintain both....
Change-Id: Ic09ebffda52cdc733b3cfeff06690e0d3cc08084
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
Reorder foreach_dpdk_rss_hf to fix rss configuration error issue.
Change-Id: Idec45534cd7dfe810b25584b1b27ac52b1c45110
Signed-off-by: Chenmin Sun <chenmin.sun@intel.com>
|
|
Change-Id: Id5b30d7a394551844a79b3d222d2d26194d033df
Signed-off-by: ChenminSun <chenmin.sun@intel.com>
|
|
The log-level dpdk config value should be transparently
forwarded to DPDK via EAL argument. Since DPDK now supports
naming log-levels, VPP no longer needs to parse and call
rte_set_loglevel().
This was the other part of the DPDK log-level change.
It must have got missed during my initial checkin.
Without it passing dynamic log-level values like are silently
ignored.
Fixes: 6ca6ac6c887e ("dpdk: support passing log-level")
Change-Id: I732cec5f638c9924e3ffb04c4753f957e3633d64
Signed-off-by: Stephen Hemminger <stephen@networkplumber.org>
|
|
Some dpdk driver does not support rte_eth_dev_rss_hash_conf_get. When that
happens, we display whatever that was in the stack variable for rss_hf which
is confusing.
The fix is to clear rss_hf prior to the call.
Before the fix
--------------
DBGvpp# sh hard
Name Idx Link Hardware
format_dpdk_device:599: rte_eth_dev_rss_hash_conf_get returned -95
GigabitEthernet13/0/0 2 up GigabitEthernet13/0/0
Link speed: 10 Gbps
Ethernet address 00:0c:29:c4:8c:eb
VMware VMXNET3
...
rss avail: ipv4 ipv4-tcp ipv6 ipv6-tcp
rss active: ipv4 ipv4-frag ipv4-tcp ipv4-udp ipv4-other
After the fix
-------------
DBGvpp# sh hard
Name Idx Link Hardware
format_dpdk_device:600: rte_eth_dev_rss_hash_conf_get returned -95
GigabitEthernet13/0/0 2 up GigabitEthernet13/0/0
Link speed: 10 Gbps
Ethernet address 00:0c:29:c4:8c:eb
VMware VMXNET3
..
rss avail: ipv4 ipv4-tcp ipv6 ipv6-tcp
rss active: none
Change-Id: If8f8327f0012eecc8d23cd7f3f9cc581ca025654
Signed-off-by: Steven <sluong@cisco.com>
|
|
Example:
dpdk {
dev 0000:01:00.0 { name eth0 }
dev 0000:02:00.0 { name eth1 }
}
Change-Id: I11e60e969a7e3548c99ac0c0c3531767819cb157
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
Change-Id: Idd4471a3adf7023e48e85717f00c786b1dde0cca
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
Change-Id: I49a5029d256df8f749ee30d19ff7473147b6516f
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
When netvsc or failsafe DPDK device is used, the DPDK port id does not
match the VPP device instance id. The code that formats the device
name was incorrectly calling DPDK device info using the VPP device
instance id. This causes the VPP interface to be named
"FortyGigabit0/2/0" based on mistakenly finding the PCI device
information of the hidden DPDK port id for the VF device.
Change-Id: I9366232f4b2087076bdcc1a58bf228007c24c084
Signed-off-by: Stephen Hemminger <stephen@networkplumber.org>
|
|
The pmd device type show with 'show hardware' is wrong if using failsafe
(or netvsc pmd) because the pmd device type should be based of the VPP device
instance, not the DPDK port id.
Fixes: a059a000f81a ("dpdk: Decoupling the meaning of xd->device_index in dpdk_plugin")
Change-Id: I3880fe674731880c5706a21d8ef3ccf8d569d46d
Signed-off-by: Stephen Hemminger <stephen@networkplumber.org>
|
|
The failsafe driver is unique because it shares device with underlying
pci device. This confuses name generation. Without this fix, the name
is wrong and multiple devices get created with same name.
Fixes: 3901a038edf4 ("dpdk: only look at PCI information on PCI devices")
Change-Id: I13796d03baf6c76dafe3667c83bea4a1ae30c48f
Signed-off-by: Stephen Hemminger <stephen@networkplumber.org>
|
|
Teach DPDK plugin about the netvsc Poll Mode Driver.
The speed of the Netvsc device matches the speed of the external
port on the underlying vswitch. Therefore 1G, 10G, 25G, 56G and
even 100G are possible.
Change-Id: I14ab6907b7d8d350b63a083409d45fb9c348a364
Signed-off-by: Stephen Hemminger <stephen@networkplumber.org>
|
|
Rather than keeping our own list of offload capabalities, use the
function in 18.08 or later to decode the value.
Also, introduce a formatter to convert to lower case because
DPDK API returns upper case names.
Change-Id: I87546fa2bec67f8a8b44288f5994514114cb6faf
Signed-off-by: Stephen Hemminger <stephen@networkplumber.org>
|
|
The rte_device is use as a base type of all DPDK devices.
It is not valid to use container_of to find PCI information
unless the bus of the rte_device is pci. Otherwise, the
pointer is looking at some other data, which may or may not
be zero.
This change introduces a helper function to get rte_pci_device
pointer. If device is on PCI bus it returns pointer to
rte_pci_device info, otherwise it returns NULL.
Change-Id: Ia7446006bb93a7a54844969f3b3dd3b918890dfd
Signed-off-by: Stephen Hemminger <stephen@networkplumber.org>
|
|
Change-Id: I89c7df778e66a5d2147190dc99445405d81964e5
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
module: id SFP/SFP+/SFP28, compatibility: 40g_active_cable
vendor: Amphenol, part NDCCGF-I202
revision: C, serial: APF1711202351C, date code: 170318
cable length: 2m
Change-Id: Ife35607b4f078f7b56737fe066ad4cbd247a7504
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
Change-Id: I085615fde1f966490f30ed5d32017b8b088cfd59
Signed-off-by: Paul Vinciguerra <pvinci@vinciconsulting.com>
|
|
Warning messsage is displayed in system log:
vpp# show log
1970/ 1/ 1 01:00:01:198 warn dpdk unsupported rx offloads requested on port 0: scatter
Change-Id: I40021066daf2d37ca5233e3adce55e412f0d3932
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
Some counters (bytes, pkts) are formatted as signed instead of unsigned
in "show hardware-interfaces" and "show lb".
These stats counters are declared as u64.
Change-Id: Id1b588188bff4e36402beb8d07f779e9a5193956
Signed-off-by: Naoyuki Mori <naoyuki.mori@intel.com>
|
|
DPDK 18.08 verifies if all set bits are supported and fails if not....
Change-Id: Ia87242fcda11147dff3bebe2e2bef32f0a8891fb
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
Change-Id: If1b93341c222160b9a08f127620c024620e55c37
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
The driver implements Cavium QLogic FastLinQ QL4xxxx 10G/25G/40G/50G/100G
Intelligent Ethernet Adapters (IEA) and Converged Network Adapters (CNA)
(doc/guides/nics/qede.rst)
Change-Id: If17e8cb572eb8c0585085be1c7cfdfa159eb6e68
Signed-off-by: Igor Mikhailov (imichail) <imichail@cisco.com>
|
|
Change-Id: I6fa4c6bf9c4e96ba4502a06907bdecc654ace665
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
Added code to initialize failsafe PMD
This is part of initial effort to enable vpp running over
dpdk on failsafe PMD in Microsoft Azure(4/4).
Change-Id: Ia2469c7087ca4b5c7881dfb11ec5c4fcebaa1d04
Signed-off-by: Rui Cai <rucai@microsoft.com>
|
|
Change-Id: I205932bc727c990011bbbe1dc6c0cf5349d19806
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
Prior to the change, dpdk plugin assumes xd->device_index is
used both as index for internal dpdk_main->devices array
and DPDK port index to call into DPDK APIs.
However, when running on top of Failsafe PMDs,
DPDK port index range may no longer be contiguous (as noted:
http://dpdk.org/ml/archives/dev/2018-March/092375.html
for related changes in DPDK). Because this, dpdk plugin can
no longer iterate through all available DPDK ports
with a for 0->rte_eth_dev_count() loop and the assumption of
device_index no longer holds.
This is part of initial effort to enable vpp running over
dpdk on failsafe PMD in Microsoft Azure(3/4).
Change-Id: I416fd80f2d40e12e139f8f3492814da98343eae7
Signed-off-by: Rui Cai <rucai@microsoft.com>
|
|
port_id be used for dpdk port_id
Change-Id: Ia7d8cdc5dec2ad658c11f9c0f3ef8005a470ac3c
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
1、Adding PMD type for support Cavium LiquidIO II CN23XX NIC;
2、Our company is using VPP + DPDK +Cavium LiquidIO II CN23XX NIC,
Unfortunately, the latest VPP code does not support
Cavium LiquidIO II CN23XX pci.
So I increased the PMD type to support LiquidIO NIC,
and can run normally, we most subsequent projects are
based on VPP + DPDK + Cavium LiquidIO II CN23XX NIC model,
so I hope VPP team can adopt this requirement, thanks a lot.
Change-Id: I604ae444d69b37c2e26962bfe4ccdfe983b75041
Signed-off-by: chuhong yao <ych@panath.cn>
|
|
Adding name, enum constants and formatting code
for failsafe PMD.
This is part of initial effort to enable vpp running over
dpdk on failsafe PMD in Microsoft Azure(2/4).
Change-Id: I4eb0093db9f666e2635f7ddff451e3c9064bd0c4
Signed-off-by: Rui Cai <rucai@microsoft.com>
|
|
Change-Id: If174d189de40e6f9ffae99997bba93a2519d9fda
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
Change-Id: I3792c524323ce9e300648abe85454cff5d19aba7
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
Change-Id: I0d10f13a56420b119fdfad97dcc135b245c269e1
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
Linux kernel and DPDK recognize the following Ethernet speeds:
10M, 100M, 1G, 2.5G, 5G, 10G, 20G, 25G, 40G, 50G, 56G and 100G.
Add consistent Ethernet speeds to VPP.
Change-Id: I4cfcf378fb34425c1206db5aa2f6bdcc66e0a6ab
Signed-off-by: Lee Roberts <lee.roberts@hpe.com>
|
|
17.11 is still default.
Change-Id: I524d232579db8a59c717c5d760398b6b7f811d03
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
On rx, the ENA PMD sets tx offload flags based on the
received packet's l4 protocol. This means you need
to turn off those offloads for every packet if you
encapsulate packets arriving on an interface using
that PMD. Disable this behavior.
Change-Id: Icae9f32e3d292d767da440ae5c1280902bdaa083
Signed-off-by: Matthew Smith <mgsmith@netgate.com>
|
|
Elastic Network Adapter PMD for newer AWS instance types
Change-Id: Ic7f6ac4a261ccc7af3ffb2ed8950274532e3feae
Signed-off-by: Matthew Smith <mgsmith@netgate.com>
|
|
Change-Id: I0a6d1257e391c3b6f7da6498bd5f7d4c545d17e9
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
Also remove DPDK 17.05 support.
Change-Id: I4f96cb3f002cd90b12d800d6904f2364d7c4e270
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
Change-Id: I02b2b69db1e2afe62e3d3413034feb3bdcb3123e
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
- always use 'va_args' as pointer in all format_* functions
- u32 for all 'indent' params as it's declaration was inconsistent
Change-Id: Ic5799309a6b104c9b50fec309cba789c8da99e79
Signed-off-by: Christophe Fontaine <christophe.fontaine@enea.com>
|