Age | Commit message (Collapse) | Author | Files | Lines |
|
Change-Id: I5fe01e918b534d1ac1d47f0d7610536f45c3158c
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
Change-Id: Ia083050389853c25b069f0f8286d50d3f4aef527
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
Change-Id: I3bb1d9f83dd08f4b93acd4a281bfec0674e39c2e
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
Change-Id: I6048c6a51efa826ac333f7d15919cb87dd766d74
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
Storing buffer in local template seems to be better option....
Change-Id: I1a2fdd68cb956f99a5b36d2cd810fc623e089bcf
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
Change-Id: Ib9c2aba1eda08a22465441e33553b9b744c79d56
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
Change-Id: I764c6565f96e0cb9078503e54e3cf3bb3fd9ff3f
Signed-off-by: Simon Zhang <yuwei1.zhang@intel.com>
|
|
Change-Id: I47d021522cfc92cfb3877449333cbf31022c06f4
Signed-off-by: Simon Zhang <yuwei1.zhang@intel.com>
|
|
Change-Id: I2ef33c7c15b3eb1f55bbfd5cbdd230d6a4d58936
Signed-off-by: Simon Zhang <yuwei1.zhang@intel.com>
|
|
Some dpdk driver does not support rte_eth_dev_rss_hash_conf_get. When that
happens, we display whatever that was in the stack variable for rss_hf which
is confusing.
The fix is to clear rss_hf prior to the call.
Before the fix
--------------
DBGvpp# sh hard
Name Idx Link Hardware
format_dpdk_device:599: rte_eth_dev_rss_hash_conf_get returned -95
GigabitEthernet13/0/0 2 up GigabitEthernet13/0/0
Link speed: 10 Gbps
Ethernet address 00:0c:29:c4:8c:eb
VMware VMXNET3
...
rss avail: ipv4 ipv4-tcp ipv6 ipv6-tcp
rss active: ipv4 ipv4-frag ipv4-tcp ipv4-udp ipv4-other
After the fix
-------------
DBGvpp# sh hard
Name Idx Link Hardware
format_dpdk_device:600: rte_eth_dev_rss_hash_conf_get returned -95
GigabitEthernet13/0/0 2 up GigabitEthernet13/0/0
Link speed: 10 Gbps
Ethernet address 00:0c:29:c4:8c:eb
VMware VMXNET3
..
rss avail: ipv4 ipv4-tcp ipv6 ipv6-tcp
rss active: none
Change-Id: If8f8327f0012eecc8d23cd7f3f9cc581ca025654
Signed-off-by: Steven <sluong@cisco.com>
|
|
* u32/u64/uword mismatches
* pointer-to-int fixes
* printf formatting issues
* issues with incorrect "ULL" and related suffixes
* structure alignment and padding issues
Change-Id: I70b989007758755fe8211c074f651150680f60b4
Signed-off-by: David Johnson <davijoh3@cisco.com>
|
|
Change-Id: If2bbfbc52994f5de0879763e0b7a7864498debb6
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
fix a copy-paste bug, and a typo of function name
Change-Id: Ib408522d2bb6fde7a7492de6f5d5369b461d77c9
Signed-off-by: Kingwel Xie <kingwel.xie@ericsson.com>
|
|
Change-Id: I3896bf9d71dc300520c53dbe3c2fd8fcd1470881
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
1. multi-loop, and new style with vlib_buffer_enqueue_to_next
2. add error counter for AUTH-FAILURE
3. buffer trace changed. now it supports 'trace add dpdk-crypto-input 10'
just like the other input nodes
Actual measurement shows >10 clocks per packets are saved, under QAT
or openssl PMD case
Change-Id: I6ea34e4ae3b08c381219ff6bc8adda2d927fbfd5
Signed-off-by: Kingwel Xie <kingwel.xie@ericsson.com>
|
|
This patch adds support for VMBus to the VPP infrastructure.
Since the only device that matters is the netvsc Poll Mode Driver
in DPDK, the infrastructure is much simpler than PCI.
Change-Id: Ie96c897ad9c426716c2398e4528688ce2217419b
Signed-off-by: Stephen Hemminger <stephen@networkplumber.org>
|
|
Change-Id: I89695c1ad47131ed830f35c677937ce12025a40d
Signed-off-by: Dave Barach <dave@barachs.net>
|
|
startup.conf
otherwise, these pools will occupy an entire huge page for each even
they are very small.
Change-Id: I08919714de9b6cd4b8dddb546ca54364b56ec99f
Signed-off-by: Kingwel Xie <kingwel.xie@ericsson.com>
|
|
fix coding style
Change-Id: I458d81fa80c509b71edb2021468a89715cb32ae3
Signed-off-by: Kingwel Xie <kingwel.xie@ericsson.com>
|
|
crypto-input,esp encrypt/decrypt are indicated in CMakefiles
Change-Id: I18ba851c1d4e5633d07c5de61cdaeae938e94982
Signed-off-by: Kingwel Xie <kingwel.xie@ericsson.com>
|
|
Change-Id: Ib6458e56f546bb5b11c23aa5e1afe0f4b5011c08
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
Example:
dpdk {
dev 0000:01:00.0 { name eth0 }
dev 0000:02:00.0 { name eth1 }
}
Change-Id: I11e60e969a7e3548c99ac0c0c3531767819cb157
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
Change-Id: I5cb2619444507a159c42ac8401800e90b6541a20
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
Change-Id: I3555230ef7b7677d6187282fb0c0f02af216e0a0
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
Change-Id: I4ec7750ef58363bd8966a16a2baeec6db18b7e9e
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
Change-Id: I6a6ab6d8d9aeca9df3ba8a3ac519be25aaa796e8
Signed-off-by: Federico Claramonte <fede.claramonte@caviumnetworks.com>
|
|
To facilitate dispatch trajectory tracing, vlib_buffer_t decoding, etc.
through Wireshark
Change-Id: I31356b9fa1f40cba8830aaf10a86a9fbb7546438
Signed-off-by: Dave Barach <dave@barachs.net>
|
|
Change-Id: Ifa6d8391b1b2413a88b7720fc434e0bc849a149a
Signed-off-by: Klement Sekera <ksekera@cisco.com>
Signed-off-by: Andrew Yourtchenko <ayourtch@gmail.com>
|
|
Change-Id: Id4f37f5d4a03160572954a416efa1ef9b3d79ad1
Signed-off-by: Dave Barach <dave@barachs.net>
|
|
Change-Id: I3daf8d473aa37b4597d130d19913b782cf7b8511
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
Change-Id: Idd4471a3adf7023e48e85717f00c786b1dde0cca
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
If no PCI address is specified in dpdk config, the default to automatically
put all PCIs in the whitelist.
For vmxnet3 PCIs, we want to change its default to exclude the vmxnet3 PCIs.
That is to put them in the blacklist instead of whitelist.
Change-Id: I2b7061d6437910eb0e1b16df19a770cab968c602
Signed-off-by: Steven <sluong@cisco.com>
|
|
Change-Id: I49a5029d256df8f749ee30d19ff7473147b6516f
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
When netvsc or failsafe DPDK device is used, the DPDK port id does not
match the VPP device instance id. The code that formats the device
name was incorrectly calling DPDK device info using the VPP device
instance id. This causes the VPP interface to be named
"FortyGigabit0/2/0" based on mistakenly finding the PCI device
information of the hidden DPDK port id for the VF device.
Change-Id: I9366232f4b2087076bdcc1a58bf228007c24c084
Signed-off-by: Stephen Hemminger <stephen@networkplumber.org>
|
|
The pmd device type show with 'show hardware' is wrong if using failsafe
(or netvsc pmd) because the pmd device type should be based of the VPP device
instance, not the DPDK port id.
Fixes: a059a000f81a ("dpdk: Decoupling the meaning of xd->device_index in dpdk_plugin")
Change-Id: I3880fe674731880c5706a21d8ef3ccf8d569d46d
Signed-off-by: Stephen Hemminger <stephen@networkplumber.org>
|
|
The failsafe driver is unique because it shares device with underlying
pci device. This confuses name generation. Without this fix, the name
is wrong and multiple devices get created with same name.
Fixes: 3901a038edf4 ("dpdk: only look at PCI information on PCI devices")
Change-Id: I13796d03baf6c76dafe3667c83bea4a1ae30c48f
Signed-off-by: Stephen Hemminger <stephen@networkplumber.org>
|
|
Fixes debug build crash.
Change-Id: Ia5c5da82beda5992f9e67456af9a4676b9b82722
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
Change-Id: Ibef46e068cd72415af28920b0146adf48105bf68
Signed-off-by: Klement Sekera <ksekera@cisco.com>
|
|
Change-Id: Iecceffe06a92660976ebb58cd3cbec4be8931db0
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
Change-Id: I88577615bfd3cddca834a7b881979ab32bfd5574
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
Change-Id: I5ff713ad0b254c74c5622e3b9425cca365b5ee97
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
Change-Id: Ic4c46bc733afae8bf0d8146623ed15633928de30
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
In DPDK 18.11 the device flags for keeping/stripping CRC flags has
changed. The old strip flag is gone, and replaced by a CRC keep
flag.
Change-Id: Iaa162854862a2a0855b418ee8029383fc116d3a2
Signed-off-by: Stephen Hemminger <stephen@networkplumber.org>
|
|
The function dpdk_ipsec_process() attempts to initialize some
globals that store node indexes after looking up the node
dpdk-esp6-decrypt. No such node was declared, so a segv
occurs after dereferencing the result of the lookup.
Add a node function that invokes dpdk_esp_decrypt_inline()
with is_ip6 set to 1. Add a declaration of node dpdk-esp6-decrypt
that uses the node function.
Change-Id: I31ce23a458c2d4181bf40cbc2118c4ef3b9baf97
Signed-off-by: Matthew Smith <mgsmith@netgate.com>
|
|
Change-Id: Ied34720ca5a6e6e717eea4e86003e854031b6eab
Signed-off-by: Dave Barach <dave@barachs.net>
|
|
- logging
- pass vlib_main_t to all APIs
- open vfio container only when needed
Change-Id: I897e53e0af3f91c3a99f0c827401d1c0ec2e478a
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
Change-Id: I70bc5af646894811d373456ec66aa83f2d75a477
Signed-off-by: Klement Sekera <ksekera@cisco.com>
|
|
Change-Id: Ibec32c6df32f4cd9889d378e244f170c93ad295b
Signed-off-by: Damjan Marion <damarion@cisco.com>
|
|
Change-Id: Iffba7ebe5af8fadc0251f3a10022739d45f394ce
Signed-off-by: Juraj Sloboda <jsloboda@cisco.com>
|
|
Change-Id: Ic6b27659f1fe9e8df39e80a0441305e4e952195a
Signed-off-by: Klement Sekera <ksekera@cisco.com>
|