summaryrefslogtreecommitdiffstats
path: root/src/vpp-api/python/vpp_papi
AgeCommit message (Collapse)AuthorFilesLines
2017-03-15Python API: Change from cPython to CFFI.Ole Troan3-828/+0
Change-Id: I03e52466fb3f909ae52b8fba601168f3eadbd972 Signed-off-by: Ole Troan <ot@cisco.com>
2017-03-07Python API: Synchronous mode.Ole Troan2-112/+121
Change-Id: Ic8f186dbb35bb4e2e191d311cab51315a88a2d81 Signed-off-by: Ole Troan <ot@cisco.com>
2017-03-03python API: work towards python/vpp api separationKlement Sekera1-1/+30
This change improves vpp_papi behaviour by introducing alternate way of calling vpp APIs. The common code is the same: vpp = VPP(...) vpp.connect(...) Calling VPP API is different, instead of deprecated: vpp.show_version() # deprecated one should write vpp.api.show_version() this allows VPP messages like "connect" and "disconnect" to be used, once the old API is dropped (in 17.07). Also part of this patch is a check for name conflict, to prevent VPP object overwriting its own functionality with generated code based on json files. Change-Id: I22e573b6a45f8b2a1f0340c5c2597c194fe42ca4 Signed-off-by: Klement Sekera <ksekera@cisco.com>
2017-01-27Python API: event_callback not initialised.Ole Troan1-0/+1
Even when not requesting notification the VPP API sends event notifications on certain calls. E.g. creating interfaces. Traceback (most recent call last): File "/vpp/ipfix/src/vpp-api/python/vpp_papi/vpp_papi.py", line 447, in msg_handler_sync if self.event_callback: AttributeError: VPP instance has no attribute 'event_callback' Change-Id: I4ca30c49df298655dc8948c5ebd68de0b3d6a592 Signed-off-by: Ole Troan <ot@cisco.com>
2017-01-24Fix PAPI async responseWojciech Dec1-1/+1
Previous changes forgot to return the decoded result Change-Id: I4eb27802eb2672532d856d9b9671ef806374bcd0 Signed-off-by: Wojciech Dec <wdec@cisco.com>
2017-01-20Python API: Missing locking of results data structure.Ole Troan1-84/+219
The wrong assumption that the GIL combined with CPython's "mostly" thread safe assurance does not hold. The combination of a slow event handler for notification and calling the API at the same time let to contention on the results data structure. Added suitable locking. Also added an atexit() to attempt a VPP disconnect on shutdown. Also: lots more comments, docstrings, duplicated code removed. Some of the problem here was a disagreement between caller and author as to how the API should be used; the comments should help. Change-Id: I0cb7d0026db660ec141425c5ad474f14bacea36e Signed-off-by: Ole Troan <ot@cisco.com> Co-Authored-By: Ian Wells <iawells@cisco.com> Signed-off-by: Ole Troan <ot@cisco.com>
2017-01-06python clients can set the API rx message queue lengthDave Barach2-6/+7
Change-Id: I7af1493a823747e0f7389ad6c2093e4cec6c2ce9 Signed-off-by: Dave Barach <dave@barachs.net>
2016-12-28Reorganize source tree to use single autotools instanceDamjan Marion3-0/+653
Change-Id: I7b51f88292e057c6443b12224486f2d0c9f8ae23 Signed-off-by: Damjan Marion <damarion@cisco.com>