docs(infra): 2n-emr
Signed-off-by: Peter Mikus <peter.mikus@protonmail.ch> Change-Id: Ib845cfdbcf38cbea9c47483d5f9e8675dc7967dd
Diffstat (limited to 'docs/content/infrastructure')
-rw-r--r--docs/content/infrastructure/fdio_csit_testbed_versioning.md12
-rw-r--r--docs/content/infrastructure/fdio_dc_testbed_specifications.md281
-rw-r--r--docs/content/infrastructure/fdio_dc_vexxhost_inventory.md8
3 files changed, 101 insertions, 200 deletions
diff --git a/docs/content/infrastructure/fdio_csit_testbed_versioning.md b/docs/content/infrastructure/fdio_csit_testbed_versioning.md
index 811060b6b6..dd284b00ba 100644
--- a/docs/content/infrastructure/fdio_csit_testbed_versioning.md
+++ b/docs/content/infrastructure/fdio_csit_testbed_versioning.md
@@ -36,9 +36,17 @@ environment versioning include:
Following is the list of CSIT versions to date:
+- Ver. 17 associated with CSIT rls2502 branch (
+ [HW](https://git.fd.io/csit/tree/docs/content/infrastructure/testbed_configuration?h=rls2502),
+ [CSIT](https://git.fd.io/csit/tree/?h=rls2502)
+ ).
+ - Intel NIC 700/800 series firmware upgrade based on DPDK compatibility
+ matrix.
+ - Mellanox 556A/CX6-DX/MCX713106AS-VEAT series firmware upgrade based on DPDK
+ compatibility matrix.
- Ver. 16 associated with CSIT rls2410 branch (
- [HW](https://git.fd.io/csit/tree/docs/content/infrastructure/testbed_configuration?h=rls2406),
- [CSIT](https://git.fd.io/csit/tree/?h=rls2406)
+ [HW](https://git.fd.io/csit/tree/docs/content/infrastructure/testbed_configuration?h=rls2410),
+ [CSIT](https://git.fd.io/csit/tree/?h=rls2410)
).
- Ver. 15 associated with CSIT rls2406 branch (
[HW](https://git.fd.io/csit/tree/docs/content/infrastructure/testbed_configuration?h=rls2406),
diff --git a/docs/content/infrastructure/fdio_dc_testbed_specifications.md b/docs/content/infrastructure/fdio_dc_testbed_specifications.md
index dd2847385b..8a58152ca5 100644
--- a/docs/content/infrastructure/fdio_dc_testbed_specifications.md
+++ b/docs/content/infrastructure/fdio_dc_testbed_specifications.md
@@ -39,20 +39,21 @@ To access these hosts, VPN connection is required.
### Summary List
```
- #. Type Purpose SUT TG #TB #SUT #TG #skx #ps1 #rng #tx2 #tsh #alt #clx #zn2 #icx #snr #spr #icxd #grc
- 1. 1-Node-Skylake nomad skx na 2 2 0 2 0 0 0 0 0 0 0 0 0 0 0 0
- 2. 1-Node-Cascadelake nomad clx na 4 4 0 0 0 0 0 0 0 4 0 0 0 0 0 0
- 3. 1-Node-AmpereAltra nomad alt na 4 4 0 0 0 0 0 0 4 0 0 0 0 0 0 0
- 4. 1-Node-SapphireRapids nomad spr na 4 4 0 0 0 0 0 0 0 0 0 0 0 4 0 0
- 6. 2-Node-Icelake perf icx icx 3 3 3 0 0 0 0 0 0 0 0 6 0 0 0 0
- 7. 2-Node-Octeon perf icx icx 1 1 1 0 0 0 0 0 0 0 0 2 0 0 0 0
- 8. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 2 0 0 0 0 0
- 9. 3-Node-Altra perf alt icx 1 2 1 0 0 0 0 0 2 0 0 1 0 0 0 0
-10. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 6 0 0 0 0
-11. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 .5 0 0 2 0 0 0
-12. 2-Node-SapphireRapids perf spr spr 4 4 4 0 0 0 0 0 0 0 0 0 0 8 0 0
-13. 3-Node-IcelakeD perf icxd icx 2 4 1 0 0 0 0 0 0 0 0 1 0 0 4 0
-14. 2-Node-Grace perf grc icx 1 1 1 0 0 0 0 0 0 0 0 1 0 0 0 1
+ #. Type Purpose SUT TG #TB #SUT #TG #skx #ps1 #rng #tx2 #tsh #alt #clx #zn2 #icx #snr #spr #icxd #grc #spr
+ 1. 1-Node-Skylake nomad skx na 2 2 0 2 0 0 0 0 0 0 0 0 0 0 0 0 0
+ 2. 1-Node-Cascadelake nomad clx na 4 4 0 0 0 0 0 0 0 4 0 0 0 0 0 0 0
+ 3. 1-Node-AmpereAltra nomad alt na 4 4 0 0 0 0 0 0 4 0 0 0 0 0 0 0 0
+ 4. 1-Node-SapphireRapids nomad spr na 4 4 0 0 0 0 0 0 0 0 0 0 0 4 0 0 0
+ 6. 2-Node-Icelake perf icx icx 3 3 3 0 0 0 0 0 0 0 0 6 0 0 0 0 0
+ 7. 2-Node-Octeon perf icx icx 1 1 1 0 0 0 0 0 0 0 0 2 0 0 0 0 0
+ 8. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 2 0 0 0 0 0 0
+ 9. 3-Node-Altra perf alt icx 1 2 1 0 0 0 0 0 2 0 0 1 0 0 0 0 0
+10. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 6 0 0 0 0 0
+11. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 .5 0 0 2 0 0 0 0
+12. 2-Node-SapphireRapids perf spr spr 4 4 4 0 0 0 0 0 0 0 0 0 0 8 0 0 0
+13. 3-Node-IcelakeD perf icxd icx 2 4 1 0 0 0 0 0 0 0 0 1 0 0 4 0 0
+14. 2-Node-Grace perf grc icx 1 1 1 0 0 0 0 0 0 0 0 1 0 0 0 1 0
+15. 2-Node-EmeraldRapids perf emr emr 2 2 4 0 0 0 0 0 0 0 0 0 0 0 0 0 6
```
### 2-Node-Zen2 EPYC AMD (2n-zn2)
@@ -118,6 +119,12 @@ one TG (Server-Type-H6) connected in a 2-node or 3-node circular topology
([Server Types](#server-types)).
Used for FD.io performance tests.
+### 2-Node-EmeraldRapids Xeon Intel (2n-emr)
+
+Each 2-Node-EmeraldRapids testbed includes one SUT (Server-Type-A1) and
+one TG (Server-Type-A2) connected in a 2-node or 3-node circular topology
+([Server Types](#server-types)).
+Used for FD.io performance tests.
## Testbed Naming Convention
@@ -649,133 +656,49 @@ FD.io CSIT lab contains following server types:
- PCIe Slot4 ?: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
- PCIe Slot9 ?: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
-## Testbeds Configuration
-
-### 1-Node-Skylake (1n-skx)
-
-```
-- SUT [Server-Type-B2]:
- - testbedname: testbed11.
- - hostname: s50-nomad.
- - IPMI IP: 10.30.50.47
- - Host IP: 10.30.51.50
- - portnames:
- - s1-t11-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
- - s1-t11-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
- - s1-t11-sut1-c8/p1 - 100GE-port1 e810-2p100GE.
- - s1-t11-sut1-c8/p2 - 100GE-port2 e810-2p100GE.
-- SUT [Server-Type-B2]:
- - testbedname: testbed12.
- - hostname: s51-nomad.
- - IPMI IP: 10.30.50.48
- - Host IP: 10.30.51.51
- - portnames:
- - s2-t12-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
- - s2-t12-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
- - s2-t12-sut1-c8/p1 - 100GE-port1 e810-2p100GE.
- - s2-t12-sut1-c8/p2 - 100GE-port2 e810-2p100GE.
-```
-
-### 1-Node-Altra (1n-alt)
-
-```
-- SUT [Server-Type-E25]:
- - testbedname: testbed13
- - hostname: s70-nomad
- - IPMI IP: 10.30.50.70
- - Host IP: 10.30.51.70
- - portnames:
- - s70-t13-sut1-c0/p1 - 40GE-port1 XL710-QDA2-2p40GE.
- - s70-t13-sut1-c0/p2 - 40GE-port2 XL710-QDA2-2p40GE.
- - s70-t13-sut1-c1/p1 - 100GE-port1 ConnectX6-2p100GE Mellanox.
- - s70-t13-sut1-c1/p2 - 100GE-port2 ConnectX6-2p100GE Mellanox.
- - s70-t13-sut1-c2/p1 - 25GE-port1 ConnectX5-2p10/25GE Mellanox.
- - s70-t13-sut1-c2/p2 - 25GE-port2 ConnectX5-2p10/25GE Mellanox.
- - s70-t13-sut1-c3/p1 - 40GE-port1 XL710-QDA2-2p40GE.
- - s70-t13-sut1-c3/p2 - 40GE-port2 XL710-QDA2-2p40GE.
- - s70-t13-sut1-c5/p1 - 25GE-port1 ConnectX5-2p10/25GE Mellanox.
- - s70-t13-sut1-c5/p2 - 25GE-port2 ConnectX5-2p10/25GE Mellanox.
-- SUT [Server-Type-E25]:
- - testbedname: testbed14
- - hostname: s71-nomad
- - IPMI IP: 10.30.50.71
- - Host IP: 10.30.51.71
- - portnames:
- - s71-t14-sut1-c0/p1 - 40GE-port1 XL710-QDA2-2p40GE.
- - s71-t14-sut1-c0/p2 - 40GE-port2 XL710-QDA2-2p40GE.
- - s71-t14-sut1-c1/p1 - 100GE-port1 ConnectX6-2p100GE Mellanox.
- - s71-t14-sut1-c1/p2 - 100GE-port2 ConnectX6-2p100GE Mellanox.
- - s71-t14-sut1-c2/p1 - 25GE-port1 ConnectX5-2p10/25GE Mellanox.
- - s71-t14-sut1-c2/p2 - 25GE-port2 ConnectX5-2p10/25GE Mellanox.
- - s71-t14-sut1-c3/p1 - 40GE-port1 XL710-QDA2-2p40GE.
- - s71-t14-sut1-c3/p2 - 40GE-port2 XL710-QDA2-2p40GE.
- - s71-t14-sut1-c5/p1 - 25GE-port1 ConnectX5-2p10/25GE Mellanox.
- - s71-t14-sut1-c5/p2 - 25GE-port2 ConnectX5-2p10/25GE Mellanox.
-```
-
-### 1-Node-SapphireRapids (1n-spr)
-
-```
-- SUT [Server-Type-H7]:
- - testbedname: testbed15.
- - hostname: s30-nomad.
- - IPMI IP: 10.30.50.30
- - Host IP: 10.30.51.30
- - portnames:
- - s30-t15-sut1-c1/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s30-t15-sut1-c1/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- - s30-t15-sut1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s30-t15-sut1-c2/p2 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s30-t15-sut1-c7/p1 - 10GE-port1 x710-4p10GE.
- - s30-t15-sut1-c7/p2 - 10GE-port2 x710-4p10GE.
- - s30-t15-sut1-c7/p3 - 10GE-port3 x710-4p10GE.
- - s30-t15-sut1-c7/p4 - 10GE-port4 x710-4p10GE.
- - s30-t15-sut1-c9/p1 - 10GE-port1 x710-4p10GE.
- - s30-t15-sut1-c9/p2 - 10GE-port2 x710-4p10GE.
- - s30-t15-sut1-c9/p3 - 10GE-port3 x710-4p10GE.
- - s30-t15-sut1-c9/p4 - 10GE-port4 x710-4p10GE.
-- SUT [Server-Type-H7]:
- - testbedname: testbed16.
- - hostname: s31-nomad.
- - IPMI IP: 10.30.50.31
- - Host IP: 10.30.51.31
- - portnames:
- - s31-t16-sut1-c1/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s31-t16-sut1-c1/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
- - s31-t16-sut1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s31-t16-sut1-c2/p2 - 100GE-port1 e810-2CQDA2-2p100GE.
- - s31-t16-sut1-c7/p1 - 10GE-port1 x710-4p10GE.
- - s31-t16-sut1-c7/p2 - 10GE-port2 x710-4p10GE.
- - s31-t16-sut1-c7/p3 - 10GE-port3 x710-4p10GE.
- - s31-t16-sut1-c7/p4 - 10GE-port4 x710-4p10GE.
- - s31-t16-sut1-c9/p1 - 10GE-port1 x710-4p10GE.
- - s31-t16-sut1-c9/p2 - 10GE-port2 x710-4p10GE.
- - s31-t16-sut1-c9/p3 - 10GE-port3 x710-4p10GE.
- - s31-t16-sut1-c9/p4 - 10GE-port4 x710-4p10GE.
-```
-
-### 2-Node-Cascadelake (2n-clx)
+26. **Server-Type-A1**: Purpose - EmeraldRapids Xeon TG for FD.io performance testing.
+ - Quantity: 4.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 2-node/3-node testbed topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro ?.
+ - Motherboard: Super X14DEG-QT-P.
+ - Processors: 2* Intel Platinum 8580 60 core 2 GHz.
+ - RAM Memory: 16* 32GB DDR5-4800.
+ - Disks: 2* 960GB SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe5.0 lanes)
+ - PCIe Slot2 18:00.xx: e810-CQDA2-2p100GE Intel.
+ - PCIe Slot4 3b:00.xx: e810-CQDA2-2p100GE Intel.
+ - PCIe Slot10 5e:00.xx: empty.
+ - Numa1: (x16, x16, x16 PCIe5.0 lanes)
+ - PCIe Slot7 86:00.xx: empty.
+ - PCIe Slot9 af:00.xx: empty.
+ - PCIe Slot11 d8:00.xx: empty.
-{{< figure src="/cdocs/testbed-2n-clx.svg" >}}
+27. **Server-Type-A2**: Purpose - EmeraldRapids SUT for FD.io performance testing.
+ - Quantity: 2.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 2-node/3-node testbed topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro ?.
+ - Motherboard: Super X14DEG-QT-P.
+ - Processors: 2* Intel Platinum 8580Y 60 core 2 GHz.
+ - RAM Memory: 16* 32GB DDR5-4800.
+ - Disks: 2* 960GB SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe5.0 lanes)
+ - PCIe Slot2 18:00.xx: e810-CQDA2-2p100GE Intel.
+ - PCIe Slot4 3b:00.xx: e810-CQDA2-2p100GE Intel.
+ - PCIe Slot10 5e:00.xx: empty.
+ - Numa1: (x16, x16, x16 PCIe5.0 lanes)
+ - PCIe Slot7 86:00.xx: empty.
+ - PCIe Slot9 af:00.xx: e810-CQDA2-2p100GE Intel.
+ - PCIe Slot11 d8:00.xx: empty.
-```
-- TG [Server-Type-C2]:
- - testbedname: testbed29.
- - hostname: s38-t29-tg1.
- - IPMI IP: 10.30.55.23
- - Host IP: 10.32.8.23
- - portnames:
- - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s38-t29-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
- - s38-t29-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
- - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
-```
+## Testbeds Configuration
### 2-Node-Zen2 (2n-zn2)
@@ -1364,65 +1287,6 @@ FD.io CSIT lab contains following server types:
## Testbed Wiring
-### 1-Node-Altra (1n-alt)
-
-```
-- testbed13:
- - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
- - s70-t13-sut1-c0/p1 - s70-t13-sut1-c3/p1.
- - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
- - s70-t13-sut1-c0/p2 - s70-t13-sut1-c3/p2.
- - ring3 100GE-ports ConnectX6-2p100GE on SUTs:
- - s70-t13-sut1-c1/p1 - s70-t13-sut1-c1/p2.
- - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
- - s70-t13-sut1-c2/p1 - s70-t13-sut1-c5/p1.
- - ring5 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
- - s70-t13-sut1-c2/p2 - s70-t13-sut1-c5/p2.
-
-- testbed14:
- - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
- - s71-t14-sut1-c0/p1 - s71-t14-sut1-c3/p1.
- - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
- - s71-t14-sut1-c0/p2 - s71-t14-sut1-c3/p2.
- - ring3 100GE-ports ConnectX6-2p100GE on SUTs:
- - s71-t14-sut1-c1/p1 - s71-t14-sut1-c1/p2.
- - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
- - s71-t14-sut1-c2/p1 - s71-t14-sut1-c5/p1.
- - ring5 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
- - s71-t14-sut1-c2/p2 - s71-t14-sut1-c5/p2.
-```
-
-### 1-Node-SapphireRapids (1n-spr)
-
-```
-- testbed15:
- - ring1 100GE-ports e810-2p100GE:
- - s30-t15-sut1-c1/p1 to s30-t15-sut1-c2/p1.
- - ring2 100GE-ports e810-2p100GE:
- - s30-t15-sut1-c1/p2 to s30-t15-sut1-c2/p2.
- - ring3 10GE-ports x710-4p10GE:
- - s30-t15-sut1-c7/p1 to s30-t15-sut1-c9/p1.
- - ring4 10GE-ports x710-4p10GE:
- - s30-t15-sut1-c7/p2 to s30-t15-sut1-c9/p2.
- - ring5 10GE-ports x710-4p10GE:
- - s30-t15-sut1-c7/p3 to s30-t15-sut1-c9/p3.
- - ring6 10GE-ports x710-4p10GE:
- - s30-t15-sut1-c7/p4 to s30-t15-sut1-c9/p4.
-- testbed16:
- - ring1 100GE-ports e810-2p100GE:
- - s31-t16-sut1-c1/p1 to s31-t16-sut1-c2/p1.
- - ring2 100GE-ports e810-2p100GE:
- - s31-t16-sut1-c1/p2 to s31-t16-sut1-c2/p2.
- - ring3 10GE-ports x710-4p10GE:
- - s31-t16-sut1-c9/p1 to s31-t16-sut1-c9/p1.
- - ring4 10GE-ports x710-4p10GE:
- - s31-t16-sut1-c9/p2 to s31-t16-sut1-c9/p2.
- - ring5 10GE-ports x710-4p10GE:
- - s31-t16-sut1-c9/p3 to s31-t16-sut1-c9/p3.
- - ring6 10GE-ports x710-4p10GE:
- - s31-t16-sut1-c9/p4 to s31-t16-sut1-c9/p4.
-```
-
### 2-Node-Zen2 (2n-zn2)
```
@@ -1679,4 +1543,25 @@ FD.io CSIT lab contains following server types:
#- ring2 200GE-ports ConnectX7-2p200GE:
# - s37-t27-tg1-c2/p1 to s36-t27-sut1-c1/p1.
# - s36-t27-sut1-c1/p2 to s37-t27-tg1-c2/p2.
+```
+
+### 2-Node-EmeraldRapids (2n-emr)
+
+```
+- testbed28:
+ - ring1 100GE-ports e810-CQDA2-2p100GE:
+ - s41-t28-tg1-c4/p1 to s40-t28-sut1-c9/p2
+ - s41-t28-tg1-c4/p2 to s40-t28-sut1-c4/p2
+ - s40-t28-sut1-c9/p1 to s40-t28-sut1-c4/p1
+ - ring2 100GE-ports e810-CQDA2-2p100GE:
+ - s40-t28-sut1-c2/p1 to s41-t28-tg1-c2/p1.
+ - s41-t28-tg1-c2/p2 to s40-t28-sut1-c2/p2.
+- testbed29:
+ - ring1 100GE-ports e810-CQDA2-2p100GE:
+ - s43-t29-tg1-c4/p1 to s42-t29-sut1-c9/p2
+ - s43-t29-tg1-c4/p1 to s42-t29-sut1-c4/p2
+ - s42-t29-sut1-c9/p1 to s43-t29-tg1-c4/p1
+ - ring2 100GE-ports e810-CQDA2-2p100GE:
+ - s42-t29-sut1-c2/p1 to s43-t29-tg1-c2/p1.
+ - s43-t29-tg1-c2/p2 to s42-t29-sut1-c2/p2.
``` \ No newline at end of file
diff --git a/docs/content/infrastructure/fdio_dc_vexxhost_inventory.md b/docs/content/infrastructure/fdio_dc_vexxhost_inventory.md
index db06f94835..61f968d757 100644
--- a/docs/content/infrastructure/fdio_dc_vexxhost_inventory.md
+++ b/docs/content/infrastructure/fdio_dc_vexxhost_inventory.md
@@ -62,6 +62,10 @@ Captured inventory data:
yul1-10-lb4m | uplink | ? | ? | ? | ? | 3016.10 | u47
s51-nomad | nomad-client | SYS-7049GP-TRT | C7470KH06A20119 | 10.30.51.51 | 10.30.50.48 | 3016.10 | u42-u45
s50-nomad | nomad-client | SYS-7049GP-TRT | C7470KH06A20154 | 10.30.51.50 | 10.30.50.47 | 3016.10 | u38-u41
+ s40-t28-sut1 | 2n-emr | SYS-??-TRT | S512539X4A04503 | 10.30.51.40 | 10.30.50.40 | 3016.10 | u34-u37
+ s41-t28-tg1 | 2n-emr | SYS-??-TRT | S512539X4A04502 | 10.30.51.41 | 10.30.50.41 | 3016.10 | u30-u33
+ s42-t29-sut1 | 2n-emr | SYS-??-TRT | S512539X4A04504 | 10.30.51.42 | 10.30.50.42 | 3016.10 | u26-u29
+ s43-t29-tg1 | 2n-emr | SYS-??-TRT | S512539X4A04500 | 10.30.51.43 | 10.30.50.43 | 3016.10 | u22-u25
s32-t31-sut1 | 3n-icxd | SYS-110D-20C-FRDN8TP| C515MKK41A30950 | 10.30.51.32 | 10.30.50.32 | 3016.10 | u21
s33-t31-sut2 | 3n-icxd | SYS-110D-20C-FRDN8TP| C515MKK41A30967 | 10.30.51.33 | 10.30.50.33 | 3016.10 | u20
s34-t32-sut1 | 3n-icxd | SYS-110D-20C-FRDN8TP| C515MKK41A30959 | 10.30.51.34 | 10.30.50.34 | 3016.10 | u19
@@ -104,5 +108,9 @@ Captured inventory data:
s61-t210-tg1 | 2n-zn2 | AS-1014S-WTRT | S366866X0515596 | 10.30.51.61 | 10.30.55.25 | 3016.12 | u31
s60-t210-sut1 | 2n-zn2 | AS-1114S-WTRT | S367023X0304458 | 10.30.51.60 | 10.30.55.24 | 3016.12 | u30
s26-nomad | nomad-server | SYS-7049GP-TRT | C7470KH37A30505 | 10.30.51.26 | 10.30.50.26 | 3016.12 | u26-u29
+ s44-t25-sut1 | 2n-zn5 | SYS-??-TRT | - | 10.30.51.44 | 10.30.50.44 | 3016.12 | u22-u25
+ s45-t25-tg1 | 2n-zn5 | SYS-??-TRT | S512539X4A04499 | 10.30.51.45 | 10.30.50.45 | 3016.12 | u18-u21
+ s46-t26-sut1 | 2n-zn5 | SYS-??-TRT | - | 10.30.51.46 | 10.30.50.46 | 3016.12 | u14-u17
+ s47-t26-tg1 | 2n-zn5 | SYS-??-TRT | S512539X4A04501 | 10.30.51.49 | 10.30.50.47 | 3016.12 | u10-u13 !!!IPMI
s37-t27-tg1 | 2n-grc | SYS-740GP-TNRT | S424016X1C31746 | 10.30.51.37 | 10.30.50.37 | 3016.12 | u2-u5
s36-t27-sut1 | 2n-grc | -- | -- | 10.30.51.36 | 10.30.50.36 | 3016.12 | u1 \ No newline at end of file