aboutsummaryrefslogtreecommitdiffstats
path: root/docs/lab/testbed_specifications.md
diff options
context:
space:
mode:
authorMaciek Konstantynowicz <mkonstan@cisco.com>2019-07-24 19:15:14 +0100
committerMaciek Konstantynowicz <mkonstan@cisco.com>2019-07-25 19:22:10 +0000
commit71151aa84d7e9c2da3b22789535aefb1f381ff87 (patch)
tree5152b3a309da2f020e58ec7d943cd5689d88faba /docs/lab/testbed_specifications.md
parent7ac38855defc0cf8140180d3abc1f5afeb467a74 (diff)
docs: updated testbed specification with clx build
Change-Id: Idaea4ac8ba04bea591ade511f55a5e421d04b8f5 Signed-off-by: Maciek Konstantynowicz <mkonstan@cisco.com>
Diffstat (limited to 'docs/lab/testbed_specifications.md')
-rw-r--r--docs/lab/testbed_specifications.md550
1 files changed, 408 insertions, 142 deletions
diff --git a/docs/lab/testbed_specifications.md b/docs/lab/testbed_specifications.md
index afa36ff56c..6c04bfbdad 100644
--- a/docs/lab/testbed_specifications.md
+++ b/docs/lab/testbed_specifications.md
@@ -5,9 +5,11 @@
1. [Summary List](#summary-list)
1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
+ 1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
+ 1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
1. [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx)
1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
@@ -18,15 +20,18 @@
1. [Addressing](#addressing)
1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
-1. [Server Type Specification](#server-type-specification)
- 1. [Server and Port Naming](#server-and-port-naming)
+1. [Server Specifications](#server-specifications)
+ 1. [Server Types](#server-types)
+ 1. [Naming Convention](#naming-convention)
1. [Testbeds Configuration](#testbeds-configuration)
1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
1. [1-Node-Skylake (1n-skx) PROD](#1-node-skylake-1n-skx-prod)
1. [1-Node-Thunderx2 (1n-tx2) WIP](#1-node-thunderx2-1n-tx2-wip)
+ 1. [1-Node-Cascadelake (1n-clx) SETUP](#1-node-cascadelake-1n-clx-setup)
1. [2-Node-Skylake (2n-skx) PROD](#2-node-skylake-2n-skx-prod)
1. [2-Node-Denverton (2n-dnv) TODO](#2-node-denverton-2n-dnv-todo)
1. [2-Node-IxiaPS1L47 (2n-ps1) VERIFY](#2-node-ixiaps1l47-2n-ps1-verify)
+ 1. [2-Node-Cascadelake (2n-clx) SETUP](#2-node-cascadelake-2n-clx-setup)
1. [3-Node-Haswell (3n-hsw) PROD](#3-node-haswell-3n-hsw-prod)
1. [3-Node-Skylake (3n-skx) PROD](#3-node-skylake-3n-skx-prod)
1. [3-Node-Rangeley (3n-rng) VERIFY](#3-node-rangeley-3n-rng-verify)
@@ -35,9 +40,11 @@
1. [Per Testbed Wiring](#per-testbed-wiring)
1. [1-Node-Skylake (1n-skx) PROD](#1-node-skylake-1n-skx-prod)
1. [1-Node-Thunderx2 (1n-tx2) WIP](#1-node-thunderx2-1n-tx2-wip)
+ 1. [1-Node-Cascadelake (1n-clx) SETUP](#1-node-cascadelake-1n-clx-setup)
1. [2-Node-Skylake (2n-skx) PROD](#2-node-skylake-2n-skx-prod)
1. [2-Node-Denverton (2n-dnv) TODO](#2-node-denverton-2n-dnv-todo)
1. [2-Node-IxiaPS1L47 (2n-ps1) VERIFY](#2-node-ixiaps1l47-2n-ps1-verify)
+ 1. [2-Node-Cascadelake (2n-clx) SETUP](#2-node-cascadelake-2n-clx-setup)
1. [3-Node-Haswell (3n-hsw) PROD](#3-node-haswell-3n-hsw-prod)
1. [3-Node-Skylake (3n-skx) PROD](#3-node-skylake-3n-skx-prod)
1. [3-Node-Rangeley (3n-rng) TODO](#3-node-rangeley-3n-rng-todo)
@@ -62,79 +69,102 @@ hosted by LFN FD.io CSIT project.
```
#. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #mcb
- 1. 1-Node-Skylake func skx na 2 2 0 0 2 0 0 0 0 0 0
- 2. 1-Node-Thunderx2 func tx2 na 1 1 0 0 0 0 0 0 1 0 0
- 3. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0
- 4. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0
- 5. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0
- 6. 3-Node-Haswell perf hsw hsw 3 6 3 9 0 0 0 0 0 0 0
- 7. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0
- 8. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0
- 9. 3-Node-Taishan perf tsh skx 1 2 1 0 .5 0 0 0 0 2 0
-10. 3-Node-Mcbin perf mcb skx 1 2 1 0 .5 0 0 0 0 0 2
-11. 1-Node-VIRL func hsw --- 3 3 0 3 0 0 0 0 0 0 0
-12. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0
- Totals: 18 28 15 12 19 1 2 3 1 2 2
+ 1. 1-Node-VIRL dev hsw --- 3 3 0 3 0 0 0 0 0 0 0
+ 2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0
+ 3. 1-Node-Thunderx2 dev tx2 na 1 1 0 0 0 0 0 0 1 0 0
+ 4. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 0
+ 5. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0
+ 6. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0
+ 7. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0
+ 8. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 0
+ 9. 3-Node-Haswell perf hsw hsw 3 6 3 9 0 0 0 0 0 0 0
+10. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0
+11. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0
+12. 3-Node-Taishan perf tsh skx 1 2 1 0 .5 0 0 0 0 2 0
+13. 3-Node-Mcbin perf mcb skx 1 2 1 0 .5 0 0 0 0 0 2
+14. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0
+ Totals: 22 35 18 12 19 1 2 3 1 2 2
```
### 1-Node-Skylake Xeon Intel (1n-skx)
-Each 1-Node-Skylake testbed includes one SUT (Type-B6 server) with NIC
-ports connected back-to-back.
+Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
+ports connected back-to-back ([Server Types](#server-types)).
Used for FD.io VPP_Device functional driver tests.
### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
-Each 1-Node-ThunderX2 testbed includes one SUT (Type-B9 server) with NIC
-ports connected back-to-back.
+Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-B9) with NIC
+ports connected back-to-back ([Server Types](#server-types)).
+Used for FD.io VPP_Device functional driver tests.
+
+### 1-Node-Cascadelake Xeon Intel (1n-clx)
+
+Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
+NIC ports connected back-to-back ([Server Types](#server-types)).
+
Used for FD.io VPP_Device functional driver tests.
### 2-Node-Skylake Xeon Intel (2n-skx)
-Each 2-Node-Skylake testbed includes one SUT (Type-B1 server) and one TG
-(Type-B2 server) connected back-to-back.
+Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
+(Server-Type-B2) connected in a 2-node circular topology
+([Server Types](#server-types)).
Used for FD.io performance tests.
### 2-Node-Denverton Atom Intel (2n-dnv)
-Each 2-Node-Skylake testbed includes one SUT (Type-B10 server) and one TG
-(Type-B2 server) connected back-to-back.
+Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
+TG (Server-Type-B2) connected in a 2-node circular topology
+([Server Types](#server-types)).
Used for FD.io performance tests.
### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
-Each 2-Node-IxiaPS1L47 testbed includes one SUT (Type-B1 server) and one
-TG (Ixia PSOne appliance) with 10GE interfaces connected back-to-back.
+Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
+TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
+circular topology ([Server Types](#server-types)).
Used for FD.io TCP/IP and HTTP performance tests.
+### 2-Node-Cascadelake Xeon Intel (2n-clx)
+
+Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
+one TG (Server-Type-C3) connected in a 2-node circular topology
+([Server Types](#server-types)).
+Used for FD.io performance tests.
+
### 3-Node-Haswell Xeon Intel (3n-hsw)
-Each 3-Node-Haswell testbed includes two SUTs (Type-A1 servers) and one
-TG (Type-A2 server) connected in full-mesh triangle.
+Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
+TG (Server-Type-A2) connected in a 3-node circular topology
+([Server Types](#server-types)).
Used for FD.io performance tests.
### 3-Node-Skylake Xeon Intel (3n-skx)
-Each 3-Node-Skylake testbed includes two SUTs (Type-B1 servers) and one
-TG (Type-B2 server) connected in full-mesh triangle.
+Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
+TG (Server-Type-B2) connected in a 3-node circular topology.
Used for FD.io performance tests.
### 3-Node-TaiShan Arm Huawei (3n-tsh)
-Each 3-Node-TaiShan testbed includes two SUTs (Type-B3 server) and one TG
-(Type-B2 server) connected in full-mesh triangle.
+Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-B3) and one
+TG (Server-Type-B2) connected in a 3-node circular topology
+([Server Types](#server-types)).
Used for FD.io performance tests.
### 3-Node-MACCHIATObin Arm Marvell
-Each 3-Node-MACCHIATObin testbed includes two SUTs (Type-B4 server) and
-one TG (Type-B2 server) connected in full-mesh triangle.
+Each 3-Node-MACCHIATObin testbed includes two SUTs (Server-Type-B4) and
+one TG (Server-Type-B2) connected in a 3-node circular topology
+([Server Types](#server-types)).
Used for FD.io performance tests.
### 3-Node-Rangeley Atom Testbeds
-Each 3-Node-Rangeley testbed includes two SUTs (Type-B5 Netgate device)
-and one TG (Type-2 server) connected in full-mesh triangle.
+Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
+TG (Server-Type-2) connected in a 3-node circular topology
+([Server Types](#server-types)).
Used for FD.io performance tests.
## Server Management
@@ -147,16 +177,16 @@ connected to the management network:
```
- 1GE IPMI port
- IPMI - Intelligent Platform Management Interface.
- - Required for access to embedded server management with WebUI, CLI, SNMPv3,
- IPMIv2.0, for firmware (BIOS) and OS updates.
+ - Required for access to embedded server management with WebUI, CLI,
+ SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
- 1GE/10GE/40GE management port
- hostOS management port for general system management.
```
### Addressing
-Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a Management
-port, which are connected to two different VLANs.
+Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
+Management port, which are connected to two different VLANs.
```
1. LOM (IPMI) VLAN:
@@ -229,7 +259,23 @@ Name | Comment
10.30.50.58 | s25-t25-sut1
10.30.50.59 | s26-t25-tg1
10.30.50.69 | s27-t13-sut
+n/a | s20-t34-sut1
+n/a | s21-t34-sut2
+10.30.51.29 | s22-t35-sut1 screen -r /dev/ttyUSB0
+10.30.51.30 | s23-t35-sut2 screen -r /dev/ttyUSB1
+10.30.51.30 | s24-t35-sut3 screen -r /dev/ttyUSB2
+10.30.55.10 | s28-t26t35-tg1
+10.30.55.11 | s29-t26-sut1
+10.30.55.12 | s30-t35-sut1
+10.30.55.13 | s31-t35-sut2
10.30.50.255 | Broadcast
+x.x.x.x | s32-t14-sut1
+x.x.x.x | s33-t27-sut1
+x.x.x.x | s34-t27-tg1
+x.x.x.x | s35-t28-sut1
+x.x.x.x | s36-t28-tg1
+x.x.x.x | s37-t29-sut1
+x.x.x.x | s38-t29-tg1
### Management VLAN IP Addresses
@@ -294,12 +340,25 @@ Name | Comment
10.30.51.106-10.30.51.180 | VIRL2
10.30.51.181-10.30.51.254 | VIRL3
10.30.51.255 | Broadcast
-
-## Server Type Specification
+10.32.8.10 | s28-t26t35-tg1
+10.32.8.11 | s29-t26-sut1
+10.32.8.12 | s30-t35-sut1
+10.32.8.13 | s31-t35-sut2
+x.x.x.x | s32-t14-sut1
+x.x.x.x | s33-t27-sut1
+x.x.x.x | s34-t27-tg1
+x.x.x.x | s35-t28-sut1
+x.x.x.x | s36-t28-tg1
+x.x.x.x | s37-t29-sut1
+x.x.x.x | s38-t29-tg1
+
+## Server Specifications
+
+### Server Types
FD.io CSIT lab contains following server types:
```
-1. Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
+1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
- Quantity: 6 servers.
- Physical connectivity:
- CIMC and host management ports.
@@ -319,7 +378,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot5: Intel NIC x710 2p10GE.
- PCIe Slot6: Intel QAT 8950 50G (Walnut Hill)
- MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
-2. Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
+2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
- Quantity: 3 servers.
- Physical connectivity:
- CIMC and host management ports.
@@ -339,7 +398,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot5: Intel NIC x710 2p10GE.
- PCIe Slot6: Intel NIC x710 2p10GE.
- MLOM slot: empty.
-3. Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
+3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
- Quantity: 3 servers.
- Physical connectivity:
- CIMC and host management ports.
@@ -355,7 +414,7 @@ FD.io CSIT lab contains following server types:
- Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
- no cards.
- MLOM slot: empty.
-4. Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
+4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
- Quantity: ---
- Physical connectivity:
- IPMI and host management ports.
@@ -363,19 +422,19 @@ FD.io CSIT lab contains following server types:
- Main HW configuration:
- Chassis: SuperMicro SYS-7049GP-TRT.
- Motherboard: SuperMicro X11DPG-QT.
- - Processors: 2* Intel Platinum 8180 2.3 GHz.
+ - Processors: 2* Intel Platinum 8180 2.5 GHz.
- RAM Memory: 16* 16GB DDR4-2666MHz.
- Disks: 2* 1.6TB 6G SATA SSD.
- NICs configuration:
- Numa0: (x16, x16, x16 PCIe3.0 lanes)
- PCIe Slot2 18:00.xx: x710-4p10GE Intel.
- PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
- - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox.
+ - PCIe Slot9 5e:00.xx: empty.
- Numa1: (x16, x16, x16 PCIe3.0 lanes)
- PCIe Slot6 86:00.xx: empty.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-2. Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
+2. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
- Quantity: ---
- Physical connectivity:
- IPMI and host management ports.
@@ -383,19 +442,19 @@ FD.io CSIT lab contains following server types:
- Main HW configuration:
- Chassis: SuperMicro SYS-7049GP-TRT.
- Motherboard: SuperMicro X11DPG-QT.
- - Processors: 2* Intel Platinum 8180 2.3 GHz.
+ - Processors: 2* Intel Platinum 8180 2.5 GHz.
- RAM Memory: 16* 16GB DDR4-2666MHz.
- Disks: 2* 1.6TB 6G SATA SSD.
- NICs configuration:
- Numa0: (x16, x16, x16 PCIe3.0 lanes)
- PCIe Slot2 18:00.xx: x710-4p10GE Intel.
- PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
- - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox.
+ - PCIe Slot9 5e:00.xx: empty.
- Numa1: (x16, x16, x16 PCIe3.0 lanes)
- PCIe Slot6 86:00.xx: empty.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
-3. Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
+3. Server-Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
- Quantity: 2
- Physical connectivity:
- IPMI(?) and host management ports.
@@ -408,7 +467,7 @@ FD.io CSIT lab contains following server types:
- NICs configuration:
- PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
- PCIe Slot6 11:00.xx: x520-2p10GE Intel.
-4. Type-B4: Purpose - MACCHIATObin Arm Marvell SUT for FD.io performance testing.
+4. Server-Type-B4: Purpose - MACCHIATObin Arm Marvell SUT for FD.io performance testing.
- Quantity: 3
- Physical connectivity:
- Host management ports.
@@ -420,7 +479,7 @@ FD.io CSIT lab contains following server types:
- Disks: 1* 128GB(?) SATA SDD
- NICs configuration:
- pp2-2p10GE Marvell (on-chip Ethernet ports ; marvell plugin in VPP)
-5. Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
+5. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
- Quantity: TBD based on testbed allocation.
- Physical connectivity:
- Management: serial Port (usb) for console
@@ -433,7 +492,7 @@ FD.io CSIT lab contains following server types:
- NICs configuration:
- 2x 10Gb Intel 82599ES
- 4x 1GB Intel I354
-6. Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
+6. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
- Quantity: 2.
- Physical connectivity:
- IPMI and host management ports.
@@ -441,7 +500,7 @@ FD.io CSIT lab contains following server types:
- Main HW configuration:
- Chassis: SuperMicro SYS-7049GP-TRT.
- Motherboard: SuperMicro X11DPG-QT.
- - Processors: 2* Intel Platinum 8180 2.3 GHz.
+ - Processors: 2* Intel Platinum 8180 2.5 GHz.
- RAM Memory: 16* 16GB DDR4-2666MHz.
- Disks: 2* 1.6TB 6G SATA SSD.
- NICs configuration:
@@ -453,7 +512,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot6 86:00.xx: empty.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-7. Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
+7. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
- Quantity: 1.
- Physical connectivity:
- Host management interface: 10/100/1000-BaseT.
@@ -472,7 +531,7 @@ FD.io CSIT lab contains following server types:
- Port-2: 10GE SFP+.
- Port-3: 10GE SFP+.
- Port-4: 10GE SFP+.
-8. Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
+8. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
@@ -480,7 +539,7 @@ FD.io CSIT lab contains following server types:
- Main HW configuration:
- Chassis: SuperMicro SYS-7049GP-TRT.
- Motherboard: SuperMicro X11DPG-QT.
- - Processors: 2* Intel Platinum 8180 2.3 GHz.
+ - Processors: 2* Intel Platinum 8180 2.5 GHz.
- RAM Memory: 16* 16GB DDR4-2666MHz.
- Disks: 2* 1.6TB 6G SATA SSD.
- NICs configuration:
@@ -492,7 +551,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot6 86:00.xx: empty.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-9. Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
+9. Server-Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
- Quantity: 1
- Physical connectivity:
- IPMI and host management ports.
@@ -509,7 +568,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot3 08:00.xx: XL710-QDA2.
- Numa1:
- PCIe Slot6 85:00.xx: XL710-QDA2.
-10. Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
+10. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
- Quantity: 4
- Physical connectivity:
- IPMI and host management ports.
@@ -523,9 +582,90 @@ FD.io CSIT lab contains following server types:
- 2x 10Gb Intel x553 fiber ports
- 2x 10Gb Intel x553 copper ports
- 4x 1GB Intel I350 ports
+
+6. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
+ - Quantity: 1.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 1-node testbed topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-7049GP-TRT.
+ - Motherboard: SuperMicro X11DPG-QT.
+ - Processors: 2* Intel Platinum 8280 2.7 GHz.
+ - RAM Memory: 12* 16GB DDR4-2933.
+ - Disks: 2* 1.92TB SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
+ - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
+ - PCIe Slot9 5e:00.xx: empty.
+ - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot6 86:00.xx: empty.
+ - PCIe Slot8 af:00.xx: empty.
+ - PCIe Slot10 d8:00.xx: empty.
+
+4. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
+ - Quantity: 3
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 2-node testbed topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-7049GP-TRT.
+ - Motherboard: SuperMicro X11DPG-QT.
+ - Processors: 2* Intel Gold 6252N 2.3 GHz.
+ - RAM Memory: 12* 16GB DDR4-2933.
+ - Disks: 2* 1.92TB SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
+ - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
+ - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
+ - Only 4 of mcx556a-edat ConnectX5-2p100GE NICs are in the lab, so only two out of three 2-node testbeds are equipped with them.
+ - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot6 86:00.xx: empty.
+ - PCIe Slot8 af:00.xx: empty.
+ - PCIe Slot10 d8:00.xx: empty.
+2. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
+ - Quantity: 3.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 2-node testbed topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-7049GP-TRT.
+ - Motherboard: SuperMicro X11DPG-QT.
+ - Processors: 2* Intel Platinum 8280 2.7 GHz.
+ - RAM Memory: 12* 16GB DDR4-2933.
+ - Disks: 2* 1.92TB SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
+ - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
+ - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
+ - Only 4 of mcx556a-edat ConnectX5-2p100GE NICs are in the lab, so only two out of three 2-node testbeds are equipped with them.
+ - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot6 86:00.xx: empty.
+ - PCIe Slot8 af:00.xx: empty.
+ - PCIe Slot10 d8:00.xx: empty.
+
+3. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
+ - Quantity: 3.
+ - Physical connectivity:
+ - CIMC and host management ports.
+ - no NIC ports, standalone setup.
+ - Main HW configuration:
+ - Chassis: SuperMicro 1029P-WTRT.
+ - Motherboard: SuperMicro X11DDW-NT.
+ - Processors: 2* Intel Platinum 8280 2.7 GHz.
+ - RAM Memory: 12* 16GB DDR4-2933.
+ - Disks: 4* 1.92TB SATA SSD.
+ - NICs configuration:
+ - Numa0:
+ - no cards.
+ - Numa1:
+ - no cards.
```
-### Server and Port Naming
+### Naming Convention
Following naming convention is used within this page to specify physical
connectivity and wiring across defined CSIT testbeds:
@@ -553,7 +693,7 @@ connectivity and wiring across defined CSIT testbeds:
#### 1-Node-Skylake (1n-skx) PROD
```
-- ServerB1 [Type-B6]:
+- SUT [Server-Type-B6]:
- testbedname: testbed11.
- hostname: s1-t11-sut1.
- IPMI IP: 10.30.50.47
@@ -567,7 +707,7 @@ connectivity and wiring across defined CSIT testbeds:
- s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
- s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
- s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
-- ServerB2 [Type-B6]:
+- SUT [Server-Type-B6]:
- testbedname: testbed12.
- hostname: s2-t12-sut1.
- IPMI IP: 10.30.50.48
@@ -586,7 +726,7 @@ connectivity and wiring across defined CSIT testbeds:
#### 1-Node-Thunderx2 (1n-tx2) WIP
```
-- ServerB17 [Type-B9]:
+- SUT [Server-Type-B9]:
- testbedname: testbed13.
- hostname: s27-t13-sut1.
- IPMI IP: 10.30.50.69
@@ -600,10 +740,29 @@ connectivity and wiring across defined CSIT testbeds:
- s27-t13-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE.
```
+#### 1-Node-Cascadelake (1n-clx) SETUP
+
+```
+- SUT [Server-Type-C1]:
+ - testbedname: testbed11.
+ - hostname: s32-t14-sut1.
+ - IPMI IP: x.x.x.x
+ - Host IP: x.x.x.x
+ - portnames:
+ - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
+ - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
+ - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
+ - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
+```
+
#### 2-Node-Skylake (2n-skx) PROD
```
-- ServerB3 [Type-B1]:
+- SUT [Server-Type-B1]:
- testbedname: testbed21.
- hostname: s3-t21-sut1.
- IPMI IP: 10.30.50.41
@@ -615,9 +774,7 @@ connectivity and wiring across defined CSIT testbeds:
- s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s3-t21-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s3-t21-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB4 [Type-B2]:
+- TG [Server-Type-B2]:
- testbedname: testbed21.
- hostname: s4-t21-tg1.
- IPMI IP: 10.30.50.42
@@ -629,9 +786,7 @@ connectivity and wiring across defined CSIT testbeds:
- s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s4-t21-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s4-t21-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB5 [Type-B1]:
+- SUT [Server-Type-B1]:
- testbedname: testbed22.
- hostname: s5-t22-sut1.
- IPMI IP: 10.30.50.49
@@ -643,9 +798,7 @@ connectivity and wiring across defined CSIT testbeds:
- s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s5-t22-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s5-t22-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB6 [Type-B2]:
+- TG [Server-Type-B2]:
- testbedname: testbed22.
- hostname: s6-t22-tg1.
- IPMI IP: 10.30.50.50
@@ -657,9 +810,7 @@ connectivity and wiring across defined CSIT testbeds:
- s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s6-t22-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s6-t22-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB7 [Type-B1]:
+- SUT [Server-Type-B1]:
- testbedname: testbed23.
- hostname: s7-t23-sut1.
- IPMI IP: 10.30.50.51
@@ -671,9 +822,7 @@ connectivity and wiring across defined CSIT testbeds:
- s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s7-t23-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s7-t23-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB8 [Type-B2]:
+- TG [Server-Type-B2]:
- testbedname: testbed23.
- hostname: s8-t23-tg1.
- IPMI IP: 10.30.50.52
@@ -685,9 +834,7 @@ connectivity and wiring across defined CSIT testbeds:
- s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s8-t23-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s8-t23-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB9 [Type-B1]:
+- SUT [Server-Type-B1]:
- testbedname: testbed24.
- hostname: s9-t24-sut1.
- IPMI IP: 10.30.50.53
@@ -699,9 +846,7 @@ connectivity and wiring across defined CSIT testbeds:
- s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s9-t24-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s9-t24-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB10 [Type-B2]:
+- TG [Server-Type-B2]:
- testbedname: testbed24.
- hostname: s10-t24-tg1.
- IPMI IP: 10.30.50.54
@@ -713,8 +858,6 @@ connectivity and wiring across defined CSIT testbeds:
- s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s10-t24-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s10-t24-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
```
#### 2-Node-Denverton (2n-dnv) WIP
@@ -722,7 +865,7 @@ connectivity and wiring across defined CSIT testbeds:
Note: ServerB28 (TG) is shared between testbed26 & testbed35
```
-- ServerB28 [Type-B2]:
+- TG [Server-Type-B2]:
- testbednames: testbed26 and testbed35.
- hostname: s28-t26t35-tg1.
- IPMI IP: 10.30.55.10
@@ -740,7 +883,7 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35
- s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE.
- s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE.
- s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE.
-- ServerB29 [Type-B10]:
+- SUT [Server-Type-B10]:
- testbednames: testbed26.
- hostname: s29-t26-sut1.
- IPMI IP: 10.30.55.11
@@ -755,7 +898,7 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35
#### 2-Node-IxiaPS1L47 (2n-ps1) VERIFY
```
-- ServerB25 [Type-B8]:
+- SUT [Server-Type-B8]:
- testbedname: testbed25.
- hostname: s25-t25-sut1.
- IPMI IP: 10.30.50.58
@@ -765,7 +908,7 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35
- s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
-- ServerB26 [Type-B7]:
+- TG [Server-Type-B7]:
- testbedname: testbed25.
- hostname: s26-t25-tg1.
- IPMI IP: 10.30.50.59
@@ -777,10 +920,99 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35
- s26-t25-tg1-p4 - 10GE-port4.
```
+#### 2-Node-Cascadelake (2n-clx) SETUP
+
+```
+- SUT [Server-Type-C2]:
+ - testbedname: testbed27.
+ - hostname: s33-t27-sut1.
+ - IPMI IP: x.x.x.x
+ - Host IP: x.x.x.x
+ - portnames:
+ - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
+ - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
+- TG [Server-Type-C3]:
+ - testbedname: testbed27.
+ - hostname: s34-t27-tg1.
+ - IPMI IP: x.x.x.x
+ - Host IP: x.x.x.x
+ - portnames:
+ - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
+ - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
+- SUT [Server-Type-C2]:
+ - testbedname: testbed28.
+ - hostname: s35-t28-sut1.
+ - IPMI IP: x.x.x.x
+ - Host IP: x.x.x.x
+ - portnames:
+ - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
+ - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
+- TG [Server-Type-C3]:
+ - testbedname: testbed28.
+ - hostname: s36-t28-tg1.
+ - IPMI IP: x.x.x.x
+ - Host IP: x.x.x.x
+ - portnames:
+ - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
+ - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
+- SUT [Server-Type-C2]:
+ - testbedname: testbed29.
+ - hostname: s37-t29-sut1.
+ - IPMI IP: x.x.x.x
+ - Host IP: x.x.x.x
+ - portnames:
+ - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s37-t29-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
+ - s37-t29-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+- TG [Server-Type-C3]:
+ - testbedname: testbed29.
+ - hostname: s38-t29-tg1.
+ - IPMI IP: x.x.x.x
+ - Host IP: x.x.x.x
+ - portnames:
+ - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s38-t29-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
+ - s38-t29-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+```
+
#### 3-Node-Haswell (3n-hsw) PROD
```
- 1. Server1 of Type-1:
+ 1. SUT [Server-Type-A1]:
- testbedname: testbed1.
- hostname: t1-sut1.
- CIMC IP: 10.30.50.17
@@ -796,7 +1028,7 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35
- t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
- t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 2. Server2 of Type-1:
+ 2. SUT [Server-Type-A1]:
- testbedname: testbed1.
- hostname: t1-sut2.
- CIMC IP: 10.30.50.18
@@ -812,7 +1044,7 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35
- t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
- t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 3. Server3 of Type-2:
+ 3. TG [Server-Type-A2]:
- testbedname: testbed1.
- hostname: t1-tg1.
- CIMC IP: 10.30.50.16
@@ -830,7 +1062,7 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35
- t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- 4. Server4 of Type-1:
+ 4. SUT [Server-Type-A1]:
- testbedname: testbed2.
- hostname: t2-sut1.
- CIMC IP: 10.30.50.21
@@ -846,7 +1078,7 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35
- t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
- t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 5. Server5 of Type-1:
+ 5. SUT [Server-Type-A1]:
- testbedname: testbed2.
- hostname: t2-sut2.
- CIMC IP: 10.30.50.22
@@ -862,7 +1094,7 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35
- t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
- t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 6. Server6 of Type-2:
+ 6. TG [Server-Type-A2]:
- testbedname: testbed2.
- hostname: t2-tg1.
- CIMC IP: 10.30.50.20
@@ -880,7 +1112,7 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35
- t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- 7. Server7 of Type-1:
+ 7. SUT [Server-Type-A1]:
- testbedname: testbed3.
- hostname: t3-sut1.
- CIMC IP: 10.30.50.25
@@ -896,7 +1128,7 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35
- t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
- t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 8. Server8 of Type-1:
+ 8. SUT [Server-Type-A1]:
- testbedname: testbed3.
- hostname: t3-sut2.
- CIMC IP: 10.30.50.26
@@ -912,7 +1144,7 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35
- t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
- t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 9. Server9 of Type-2:
+ 9. TG [Server-Type-A2]:
- testbedname: testbed3.
- hostname: t3-tg1.
- CIMC IP: 10.30.50.24
@@ -935,7 +1167,7 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35
#### 3-Node-Skylake (3n-skx) PROD
```
-- ServerB11 [Type-B1]:
+- ServerB11 [Server-Type-B1]:
- testbedname: testbed31.
- hostname: s11-t31-sut1.
- IPMI IP: 10.30.50.43
@@ -949,7 +1181,7 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35
- s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB12 [Type-B1]:
+- ServerB12 [Server-Type-B1]:
- testbedname: testbed31.
- hostname: s12-t31-sut2.
- IPMI IP: 10.30.50.44
@@ -963,7 +1195,7 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35
- s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB13 [Type-B2]:
+- ServerB13 [Server-Type-B2]:
- testbedname: testbed31.
- hostname: s13-t31-tg1.
- IPMI IP: 10.30.50.45
@@ -977,7 +1209,7 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35
- s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB14 [Type-B1]:
+- ServerB14 [Server-Type-B1]:
- testbedname: testbed32.
- hostname: s14-t32-sut1.
- IPMI IP: 10.30.50.55
@@ -991,7 +1223,7 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35
- s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB15 [Type-B1]:
+- ServerB15 [Server-Type-B1]:
- testbedname: testbed32.
- hostname: s15-t32-sut2.
- IPMI IP: 10.30.50.56
@@ -1005,7 +1237,7 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35
- s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB16 [Type-B2]:
+- ServerB16 [Server-Type-B2]:
- testbedname: testbed32.
- hostname: s16-t32-tg1.
- IPMI IP: 10.30.50.57
@@ -1026,7 +1258,7 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35
Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
```
-- ServerB22 [Type-B5]:
+- ServerB22 [Server-Type-B5]:
- testbedname: testbed35.
- hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
- IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
@@ -1035,7 +1267,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
- s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
- s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
- 1GB ports (tbd)
-- ServerB23 [Type-B5]:
+- ServerB23 [Server-Type-B5]:
- testbedname: testbed35.
- hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
- IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
@@ -1044,7 +1276,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
- s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
- s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
- 1GB ports (tbd)
-- ServerB24 [Type-B5]:
+- ServerB24 [Server-Type-B5]:
- testbedname: testbed35.
- hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
- IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
@@ -1060,7 +1292,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
Note: ServerB19 (TG) is shared between testbed33 & testbed34
```
-- ServerB17 [Type-B3]:
+- ServerB17 [Server-Type-B3]:
- testbedname: testbed33.
- hostname: s17-t33-sut1.
- IPMI IP: 10.30.50.36
@@ -1070,7 +1302,7 @@ Note: ServerB19 (TG) is shared between testbed33 & testbed34
- s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
- s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
- s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
-- ServerB18 [Type-B3]:
+- ServerB18 [Server-Type-B3]:
- testbedname: testbed33.
- hostname: s18-t33-sut2.
- IPMI IP: 10.30.50.37
@@ -1080,7 +1312,7 @@ Note: ServerB19 (TG) is shared between testbed33 & testbed34
- s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
- s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
- s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
-- ServerB19 [Type-B2]:
+- ServerB19 [Server-Type-B2]:
- testbednames: testbed33 and testbed34.
- hostname: s19-t33t34-tg1.
- IPMI IP: 10.30.50.46
@@ -1096,7 +1328,7 @@ Note: ServerB19 (TG) is shared between testbed33 & testbed34
- s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
- s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
- s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
-- ServerB20 [Type-B4]:
+- ServerB20 [Server-Type-B4]:
- testbedname: testbed34.
- hostname: s20-t34-sut1.
- IPMI IP: N/A
@@ -1104,7 +1336,7 @@ Note: ServerB19 (TG) is shared between testbed33 & testbed34
- portnames:
- s20-t34-sut1-ca/p1 - 10GE-port1 Marvell.
- s20-t34-sut1-ca/p2 - 10GE-port2 Marvell.
-- ServerB21 [Type-B4]:
+- ServerB21 [Server-Type-B4]:
- testbedname: testbed34.
- hostname: s21-t34-sut2.
- IPMI IP: N/A
@@ -1117,7 +1349,7 @@ Note: ServerB19 (TG) is shared between testbed33 & testbed34
#### 3-Node-Denverton (3n-dnv) WIP
```
-- ServerB30 [Type-B10]:
+- ServerB30 [Server-Type-B10]:
- testbednames: testbed35.
- hostname: s30-t35-sut1.
- IPMI IP: 10.30.55.12
@@ -1127,7 +1359,7 @@ Note: ServerB19 (TG) is shared between testbed33 & testbed34
- s30-t35-sut1-p2 - 10GE-port2 x553 copper port.
- s30-t35-sut1-p3 - 10GE-port3 x553 fiber port.
- s30-t35-sut1-p4 - 10GE-port4 x553 fiber port.
-- ServerB31 [Type-B10]:
+- ServerB31 [Server-Type-B10]:
- testbednames: testbed35.
- hostname: s31-t35-sut2.
- IPMI IP: 10.30.55.13
@@ -1182,6 +1414,20 @@ To be completed.
- s27-t13-sut1-c6/p2 - s27-t13-sut1-c1/p1.
```
+#### 1-Node-Cascadelake (1n-clx) SETUP
+
+```
+- testbed14:
+ - ring1 10GE-ports x710-4p10GE:
+ - s32-t14-sut1-c2/p1 to s32-t14-sut1-c4/p1.
+ - ring2 10GE-ports x710-4p10GE:
+ - s32-t14-sut1-c2/p2 to s32-t14-sut1-c4/p2.
+ - ring3 10GE-ports x710-4p10GE:
+ - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
+ - ring4 10GE-ports x710-4p10GE:
+ - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
+```
+
#### 2-Node-Skylake (2n-skx) PROD
```
@@ -1195,12 +1441,6 @@ To be completed.
- ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
- s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
- - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
- - s4-t21-tg1-c9/p1 to s3-t21-sut1-c9/p1.
- - s3-t21-sut1-c9/p2 to s4-t21-tg1-c9/p2.
- - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
- - s4-t21-tg1-c10/p1 to s4-t21-tg1-c10/p2.
- - s4-t21-tg1-c10/p3 to s4-t21-tg1-c10/p4.
- testbed22:
- ring1 10GE-ports x710-4p10GE on SUT:
- s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
@@ -1211,12 +1451,6 @@ To be completed.
- ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
- s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
- - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
- - t22-tg1-c9/p1 to s5-t22-sut1-c9/p1.
- - s5-t22-sut1-c9/p2 to s6-t22-tg1-c9/p2.
- - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
- - s6-t22-tg1-c10/p1 to s6-t22-tg1-c10/p2.
- - s6-t22-tg1-c10/p3 to s6-t22-tg1-c10/p4.
- testbed23:
- ring1 10GE-ports x710-4p10GE on SUT:
- s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
@@ -1227,12 +1461,6 @@ To be completed.
- ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
- s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
- - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
- - s8-t23-tg1-c9/p1 to s7-t23-sut1-c9/p1.
- - s7-t23-sut1-c9/p2 to s8-t23-tg1-c9/p2.
- - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
- - s8-t23-tg1-c10/p1 to s8-t23-tg1-c10/p2.
- - s8-t23-tg1-c10/p3 to s8-t23-tg1-c10/p4.
- testbed24:
- ring1 10GE-ports x710-4p10GE on SUT:
- s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
@@ -1243,12 +1471,6 @@ To be completed.
- ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
- s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
- - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
- - s10-t24-tg1-c9/p1 to s9-t24-sut1-c9/p1.
- - s9-t24-sut1-c9/p2 to s10-t24-tg1-c9/p2.
- - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
- - s10-t24-tg1-c10/p1 to s10-t24-tg1-c10/p2.
- - s10-t24-tg1-c10/p3 to s10-t24-tg1-c10/p4.
```
#### 2-Node-Denverton (2n-dnv) WIP
@@ -1277,6 +1499,50 @@ To be completed.
- t25-tg1-p4 to t25-sut1-c2/p4.
```
+#### 2-Node-Cascadelake (2n-clx) SETUP
+
+```
+- testbed27:
+ - ring1 10GE-ports x710-4p10GE on SUT:
+ - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
+ - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
+ - ring2 10GE-ports x710-4p10GE on SUT:
+ - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
+ - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
+ - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
+ - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
+ - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
+ - ring4 100GE-ports ConnectX5-2p100GE on SUT:
+ - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
+ - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
+- testbed28:
+ - ring1 10GE-ports x710-4p10GE on SUT:
+ - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
+ - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
+ - ring2 10GE-ports x710-4p10GE on SUT:
+ - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
+ - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
+ - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
+ - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
+ - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
+ - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
+ - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
+ - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
+- testbed29:
+ - ring1 10GE-ports x710-4p10GE on SUT:
+ - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
+ - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
+ - ring2 10GE-ports x710-4p10GE on SUT:
+ - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
+ - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
+ - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
+ - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
+ - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
+ - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
+ - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
+ - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
+```
+
#### 3-Node-Haswell (3n-hsw) PROD
```
@@ -1487,7 +1753,7 @@ To be completed.
- 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
- Chassis: SuperMicro SYS-7049GP-TRT.
- Motherboard: SuperMicro X11DPG-QT.
- - Processors: 2* Intel Platinum 8180 2.3 GHz.
+ - Processors: 2* Intel Platinum 8180 2.5 GHz.
- RAM Memory: 16* 16GB DDR4-2666MHz.
- Disks: 2* 1.6TB 6G SATA SSD.
2. Intel Atom servers with Rangely processors.