diff options
author | 2025-03-17 13:56:56 +0100 | |
---|---|---|
committer | 2025-03-17 13:05:28 +0000 | |
commit | e765f6cdb4edf13f3192b364c6973d8367318289 (patch) | |
tree | f245316e960f5ff80d72d87aeebb90ab945537e9 /docs | |
parent | 37e0508c232c6d4586eac4f0c9c83eaa2ee7b1d1 (diff) |
feat(infra): NVidia NIC swapoper-250317
Signed-off-by: Peter Mikus <peter.mikus@icloud.com>
Change-Id: Ib6dee085e33912c2439bc8efcb299544fc7911f0
(cherry picked from commit 37476828f3b11304f254ebabba2212098658b30f)
Diffstat (limited to 'docs')
-rw-r--r-- | docs/content/infrastructure/fdio_dc_testbed_specifications.md | 31 |
1 files changed, 10 insertions, 21 deletions
diff --git a/docs/content/infrastructure/fdio_dc_testbed_specifications.md b/docs/content/infrastructure/fdio_dc_testbed_specifications.md index 102ba6468b..28c39fcdbf 100644 --- a/docs/content/infrastructure/fdio_dc_testbed_specifications.md +++ b/docs/content/infrastructure/fdio_dc_testbed_specifications.md @@ -79,7 +79,7 @@ Used for FD.io performance tests. ### 2-Node-Grace Server Nvidia (2n-grc) -Each 2-Node-Grace testbed includes one SUT (Server-Type-XX) and +Each 2-Node-Grace testbed includes one SUT (Server-Type-J1) and one TG (Server-Type-F6) connected in a 2-node circular topology ([Server Types](#server-types)). Used for FD.io performance tests. @@ -454,9 +454,9 @@ FD.io CSIT lab contains following server types: - Disks: 2* 960GB SATA SSD. - NICs configuration: - Numa0: (x16, x16, x16 PCIe4.0 lanes) - - PCIe Slot2 4b:00.xx: ConnectX5-2p100GE Mellanox. - - PCIe Slot4 31:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - PCIe Slot9 ff:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. + - PCIe Slot2 17:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. + - PCIe Slot4 31:00.xx: empty. + - PCIe Slot9 ff:00.xx: empty. - Numa1: (x16, x16, x16 PCIe4.0 lanes) - PCIe Slot6 ca:00.xx: empty. - PCIe Slot8 b1:00.xx: empty. @@ -652,9 +652,7 @@ FD.io CSIT lab contains following server types: - Disks: NDA. - NICs configuration: - Numa0: (x16, x16, x16, x16 PCIe5.0 lanes) - - PCIe Slot2 ?: ConnectX5-2p100GE Mellanox. - - PCIe Slot4 ?: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - - PCIe Slot9 ?: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. + - PCIe Slot1 0000:01:00.0: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. 26. **Server-Type-A1**: Purpose - EmeraldRapids Xeon TG for FD.io performance testing. - Quantity: 4. @@ -1257,10 +1255,8 @@ FD.io CSIT lab contains following server types: - IPMI IP: 10.30.50.36 - Host IP: 10.30.51.36 - portnames: - - s36-t27-sut1-c1/p1 - 100GE-port1 ConnectX5-2p100GE. - - s36-t27-sut1-c1/p2 - 100GE-port2 ConnectX5-2p100GE. - - s36-t27-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE. - - s36-t27-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE. + - s36-t27-sut1-c1/p1 - 200GE-port1 ConnectX7-2p200GE. + - s36-t27-sut1-c1/p2 - 200GE-port2 ConnectX7-2p200GE. - s36-t27-sut1-c3/p1 - 10GE-port1 x550T-2p10GE. - s36-t27-sut1-c3/p2 - 10GE-port1 x550T-2p10GE. - TG [Server-Type-F6]: @@ -1269,12 +1265,8 @@ FD.io CSIT lab contains following server types: - IPMI IP: 10.30.50.37 - Host IP: 10.30.51.37 - portnames: - - s37-t27-tg1-c2/p1 - 100GE-port1 ConnectX5-2p100GE. - - s37-t27-tg1-c2/p2 - 100GE-port2 ConnectX5-2p100GE. - - s37-t27-tg1-c4/p1 - 100GE-port1 ConnectX5-2p100GE. - - s37-t27-tg1-c4/p2 - 100GE-port2 ConnectX5-2p100GE. - - s37-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. - - s37-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. + - s37-t27-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE. + - s37-t27-tg1-c2/p2 - 200GE port2 ConnectX7-2p200GE. ``` ## Testbed Wiring @@ -1516,12 +1508,9 @@ FD.io CSIT lab contains following server types: ``` - testbed27: - - ring1 100GE-ports ConnectX5-2p100GE: + - ring1 200GE-ports ConnectX7-2p200GE: - s37-t27-tg1-c9/p1 to s36-t27-sut1-c1/p1. - s36-t27-sut1-c1/p2 to s37-t27-tg1-c9/p2. - #- ring2 200GE-ports ConnectX7-2p200GE: - # - s37-t27-tg1-c2/p1 to s36-t27-sut1-c1/p1. - # - s36-t27-sut1-c1/p2 to s37-t27-tg1-c2/p2. ``` ### 2-Node-EmeraldRapids (2n-emr) |