aboutsummaryrefslogtreecommitdiffstats
path: root/docs/content/infrastructure/fdio_dc_testbed_specifications.md
diff options
context:
space:
mode:
Diffstat (limited to 'docs/content/infrastructure/fdio_dc_testbed_specifications.md')
-rw-r--r--docs/content/infrastructure/fdio_dc_testbed_specifications.md20
1 files changed, 10 insertions, 10 deletions
diff --git a/docs/content/infrastructure/fdio_dc_testbed_specifications.md b/docs/content/infrastructure/fdio_dc_testbed_specifications.md
index 831cee47e4..cda2ff1624 100644
--- a/docs/content/infrastructure/fdio_dc_testbed_specifications.md
+++ b/docs/content/infrastructure/fdio_dc_testbed_specifications.md
@@ -49,7 +49,7 @@ To access these hosts, VPN connection is required.
8. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 2 0 0 0 0 0
9. 3-Node-Altra perf alt icx 1 2 1 0 0 0 0 0 2 0 0 1 0 0 0 0
10. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 6 0 0 0 0
-11. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 0 0 .5 2 0 0 0
+11. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 .5 0 0 2 0 0 0
12. 2-Node-SapphireRapids perf spr spr 4 4 4 0 0 0 0 0 0 0 0 0 0 8 0 0
13. 3-Node-IcelakeD perf icxd icx 2 4 1 0 0 0 0 0 0 0 0 1 0 0 4 0
14. 2-Node-Grace perf grc icx 1 1 1 0 0 0 0 0 0 0 0 1 0 0 0 1
@@ -194,7 +194,7 @@ FD.io CSIT lab contains following server types:
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
-2. **Server-Type-C2**: Purpose - Cascadelake Xeon TG for FD.io performance testing.
+2. **Server-Type-C2**: Purpose - Cascadelake Xeon Shared TG for FD.io performance testing.
- Quantity: 1.
- Physical connectivity:
- IPMI and host management ports.
@@ -206,13 +206,13 @@ FD.io CSIT lab contains following server types:
- RAM Memory: 12* 16GB DDR4-2933.
- Disks: 2* 1.92TB SATA SSD.
- NICs configuration:
- - Numa0: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
- - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
- - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
- - Numa1: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot6 86:00.xx: ConnectX5-2p100GE Mellanox.
- - PCIe Slot8 af:00.xx: ConnectX5-2p100GE Mellanox.
+ - Numa0: (x16, x16, x16 PCIe4.0 lanes)
+ - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
+ - PCIe Slot4 31:00.xx: empty.
+ - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
+ - Numa1: (x16, x16, x16 PCIe4.0 lanes)
+ - PCIe Slot6 86:00.xx: e810-XXVDA4-4p25GE Intel.
+ - PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
3. **Server-Type-C3**: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
@@ -1141,7 +1141,7 @@ FD.io CSIT lab contains following server types:
- s94-t39-sut2-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
- s94-t39-sut2-c1/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
- s94-t39-sut2-c1/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
-- ServerF4 [Server-Type-F5]:
+- ServerC2 [Server-Type-C2]:
- testbedname: testbed39.
- hostname: s89-t39t310-tg1.
- IPMI IP: 10.30.50.89