-rw-r--r--docs/lab/testbed_specifications.md2031
-rw-r--r--docs/lab/testbeds_sm_clx_hw_bios_cfg.md1453
-rw-r--r--docs/lab/testbeds_sm_dnv_hw_bios_cfg.md351
-rw-r--r--docs/lab/testbeds_sm_skx_hw_bios_cfg.md577
-rw-r--r--docs/lab/testbeds_sm_zn2_hw_bios_cfg.md634
-rw-r--r--docs/lab/testbeds_ucs_hsw_hw_bios_cfg.md740
6 files changed, 0 insertions, 5786 deletions
diff --git a/docs/lab/testbed_specifications.md b/docs/lab/testbed_specifications.md
deleted file mode 100644
index 7d4f0e001a..0000000000
--- a/docs/lab/testbed_specifications.md
+++ /dev/null
@@ -1,2031 +0,0 @@
-# FD.io CSIT Testbed Specifications
-
-1. [Purpose](#purpose)
-1. [Testbeds Overview](#testbeds-overview)
- 1. [Summary List](#summary-list)
- 1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
- 1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
- 1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
- 1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
- 1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
- 1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
- 1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
- 1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
- 1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2)
- 1. [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx)
- 1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
- 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
- 1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
-1. [Server Management](#server-management)
- 1. [Requirements](#requirements)
- 1. [Addressing](#addressing)
- 1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
- 1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
-1. [Server Specifications](#server-specifications)
- 1. [Server Types](#server-types)
- 1. [Naming Convention](#naming-convention)
-1. [Testbeds Configuration](#testbeds-configuration)
- 1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
- 1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
- 1. [1-Node-ThunderX2 Servers (1n-tx2) PROD](#1-node-thunderx2-servers-1n-tx2-prod)
- 1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod)
- 1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
- 1. [2-Node-Denverton Servers (2n-dnv) TODO](#2-node-denverton-servers-2n-dnv-todo)
- 1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
- 1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod)
- 1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod])
- 1. [2-Node-ThunderX2 Servers (2n-tx2) WIP](#2-node-thunderx2-servers-2n-tx2-wip)
- 1. [3-Node-Haswell Servers (3n-hsw) PROD](#3-node-haswell-servers-3n-hsw-prod)
- 1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
- 1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
- 1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod)
- 1. [Per Testbed Wiring](#per-testbed-wiring)
- 1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
- 1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod)
- 1. [1-Node-Cascadelake Wiring (1n-clx) PROD](#1-node-cascadelake-wiring-1n-clx-prod)
- 1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
- 1. [2-Node-Denverton Wiring (2n-dnv) TODO](#2-node-denverton-wiring-2n-dnv-todo)
- 1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
- 1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
- 1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod])
- 1. [2-Node-ThunderX2 Wiring (2n-tx2) WIP](#2-node-thunderx2-wiring-2n-tx2-wip)
- 1. [3-Node-Haswell Wiring (3n-hsw) PROD](#3-node-haswell-wiring-3n-hsw-prod)
- 1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
- 1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo)
- 1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod)
-1. [Inventory](#inventory)
- 1. [Appliances](#appliances)
- 1. [Arm Servers](#arm-servers)
- 1. [Xeon and Atom Servers](#xeon-and-atom-servers)
- 1. [Network Interface Cards](#network-interface-cards)
- 1. [Pluggables and Cables](#pluggables-and-cables)
- 1. [Other Parts](#other-parts)
-
-## Purpose
-
-This note includes specification of the physical testbed infrastructure
-hosted by LFN FD.io CSIT project.
-
-## Testbeds Overview
-
-### Summary List
-
-```
- #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #clx #zn2
- 1. 1-Node-VIRL dev hsw --- 3 3 0 3 0 0 0 0 0 0 0 0
- 2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0 0
- 3. 1-Node-ThunderX2 perf tx2 na 1 1 .5 0 .5 0 0 0 1 0 0 0
- 4. 1-Node-ThunderX2 dev tx2 na 2 2 0 0 0 0 0 0 2 0 0 0
- 5. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 1 0
- 6. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0 0
- 7. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0 0
- 8. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0 0
- 9. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 6 0
-10. 3-Node-Haswell perf hsw hsw 3 6 3 9 0 0 0 0 0 0 0 0
-11. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 0
-12. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 0
-13. 3-Node-Taishan perf tsh skx 1 2 .5 0 .5 0 0 0 0 2 0 0
-14. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0 0
-15. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 0 2
- Totals: 27 36 18 12 19 1 2 3 3 2 7 2
-```
-
-### 1-Node-Skylake Xeon Intel (1n-skx)
-
-Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
-ports connected back-to-back ([Server Types](#server-types)).
-Used for FD.io VPP_Device functional driver tests.
-
-### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
-
-Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-B11) with NIC
-ports connected back-to-back ([Server Types](#server-types)).
-Used for FD.io VPP_Device functional driver tests.
-
-### 1-Node-Cascadelake Xeon Intel (1n-clx)
-
-Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
-NIC ports connected back-to-back ([Server Types](#server-types)).
-
-Used for FD.io VPP_Device functional driver tests.
-
-### 2-Node-Skylake Xeon Intel (2n-skx)
-
-Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
-(Server-Type-B2) connected in a 2-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
-### 2-Node-Denverton Atom Intel (2n-dnv)
-
-Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
-TG (Server-Type-B2) connected in a 2-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
-### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
-
-Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
-TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
-circular topology ([Server Types](#server-types)).
-Used for FD.io TCP/IP and HTTP performance tests.
-
-### 2-Node-Cascadelake Xeon Intel (2n-clx)
-
-Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
-one TG (Server-Type-C3) connected in a 2-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
-### 2-Node-Zen2 EPYC AMD (2n-zn2)
-
-Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and
-one TG (Server-Type-D2) connected in a 2-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
-### 2-Node-ThunderX2 Arm Marvell (2x-tx2)
-
-Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-B9) and
-one TG (Server-Type-B12) connected in a 2-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
-### 3-Node-Haswell Xeon Intel (3n-hsw)
-
-Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
-TG (Server-Type-A2) connected in a 3-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
-### 3-Node-Skylake Xeon Intel (3n-skx)
-
-Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
-TG (Server-Type-B2) connected in a 3-node circular topology.
-Used for FD.io performance tests.
-
-### 3-Node-TaiShan Arm Huawei (3n-tsh)
-
-Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-B3) and one
-TG (Server-Type-B12) connected in a 3-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
-### 3-Node-Rangeley Atom Testbeds
-
-Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
-TG (Server-Type-2) connected in a 3-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
-## Server Management
-
-### Requirements
-
-For management purposes, each server must have following two ports
-connected to the management network:
-
-```
-- 1GE IPMI port
- - IPMI - Intelligent Platform Management Interface.
- - Required for access to embedded server management with WebUI, CLI,
- SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
-- 1GE/10GE/40GE management port
- - hostOS management port for general system management.
-```
-
-### Addressing
-
-Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
-Management port, which are connected to two different VLANs.
-
-```
-1. LOM (IPMI) VLAN:
- - Subnet: 10.30.50.0/24
- - Gateway: 10.30.50.1
- - Broadcast: 10.30.50.255
- - DNS1: 199.204.44.24
- - DNS2: 199.204.47.54
-2. Management Vlan:
- - Subnet: 10.30.51.0/24
- - Gateway: 10.30.51.1
- - Broadcast: 10.30.51.255
- - DNS1: 199.204.44.24
- - DNS2: 199.204.47.54
-```
-
-To access these hosts, VPN connection is required.
-
-### LOM (IPMI) VLAN IP Addresses
-
-Name | Comment
------------- | -------
-10.30.50.0 | network
-10.30.51.1 | Router
-10.30.50.2 | LF Reserved
-10.30.50.3 | LF Reserved
-10.30.50.4 | LF Reserved
-10.30.50.5 | LF Reserved
-10.30.50.6 | LF Reserved
-10.30.50.7 | LF Reserved
-10.30.50.8 | LF Reserved
-10.30.50.9 | LF Reserved
-10.30.50.10 | LF Reserved
-10.30.50.11 | LF Reserved
-10.30.50.12 | LF Reserved
-10.30.50.13 | LF Reserved
-10.30.50.14 | LF Reserved
-10.30.50.15 | LF Reserved
-10.30.50.16 | t1-tg1
-10.30.50.17 | t1-sut1
-10.30.50.18 | t1-sut2
-10.30.50.20 | t2-tg1
-10.30.50.21 | t2-sut1
-10.30.50.22 | t2-sut2
-10.30.50.24 | t3-tg1
-10.30.50.25 | t3-sut1
-10.30.50.26 | t3-sut-2
-10.30.50.28 | s41-nomad
-10.30.50.29 | s39-nomad
-10.30.51.29 | s22-t35-sut1 screen -r /dev/ttyusb0
-10.30.50.30 | s40-nomad
-10.30.51.30 | s23-t35-sut2 screen -r /dev/ttyusb1
-10.30.51.30 | s24-t35-sut3 screen -r /dev/ttyusb2
-10.30.50.32 | s42-nomad
-10.30.50.33 | s43-nomad
-10.30.50.34 | s44-nomad
-10.30.50.35 | s45-nomad
-10.30.50.36 | s17-t33-sut1
-10.30.50.37 | s18-t33-sut2
-10.30.50.38 | fdio-marvell-dev
-10.30.50.39 | s53-nomad
-10.30.50.40 | s54-nomad
-10.30.50.41 | s3-t21-sut1
-10.30.50.42 | s4-t21-tg1
-10.30.50.43 | s11-t31-sut1
-10.30.50.44 | s12-t31-sut2
-10.30.50.45 | s13-t31-tg1
-10.30.50.46 | s19-t33t34-tg1
-10.30.50.47 | s1-t11-sut1
-10.30.50.48 | s2-t12-sut1
-10.30.50.49 | s5-t22-sut1
-10.30.50.50 | s6-t22-tg1
-10.30.50.51 | s7-t23-sut1
-10.30.50.52 | s8-t23-tg1
-10.30.50.53 | s9-t24-sut1
-10.30.50.54 | s10-t24-tg1
-10.30.50.55 | s14-t32-sut1
-10.30.50.56 | s15-t32-sut2
-10.30.50.57 | s16-t32-tg1
-10.30.50.58 | s25-t25-sut1
-10.30.50.59 | s26-t25-tg1
-10.30.50.65 | s52-nomad
-10.30.50.66 | s51-nomad
-10.30.50.67 | s49-nomad
-10.30.50.68 | s50-nomad
-10.30.50.69 | s27-t34-sut1
-10.30.50.70 | s55-t36-sut1
-10.30.50.71 | s56-t37-sut1
-10.30.50.255 | Broadcast
-n/a | s20-t34-sut1
-n/a | s21-t34-sut2
-10.30.55.0 | network
-10.30.55.1 | Router
-10.30.55.10 | s28-t26t35-tg1
-10.30.55.11 | s29-t26-sut1
-10.30.55.12 | s30-t35-sut1
-10.30.55.13 | s31-t35-sut2
-10.30.55.14 | s46-nomad
-10.30.55.15 | s47-nomad
-10.30.55.16 | s48-nomad
-10.30.55.17 | s57-nomad
-10.30.55.18 | s33-t27-sut1
-10.30.55.19 | s34-t27-tg1
-10.30.55.20 | s35-t28-sut1
-10.30.55.21 | s36-t28-tg1
-10.30.55.22 | s37-t29-sut1
-10.30.55.23 | s38-t29-tg1
-10.30.55.24 | s60-t210-sut1
-10.30.55.25 | s61-t210-tg1
-10.30.55.255 | Broadcast
-
-### Management VLAN IP Addresses
-
-Name | Comment
-------------------------- | -------
-10.30.51.0 | network
-10.30.51.1 | Router
-10.30.51.2 | LF Reserved
-10.30.51.3 | LF Reserved
-10.30.51.4 | LF Reserved
-10.30.51.5 | LF Reserved
-10.30.51.6 | LF Reserved
-10.30.51.7 | LF Reserved
-10.30.51.8 | LF Reserved
-10.30.51.9 | s22-t35-sut1 (netgate-1)
-10.30.51.10 | s23-t35-sut2 (netgate-2)
-10.30.51.11 | s24-t35-sut3 (netgate-3)
-10.30.51.12 | softiron-1 (decommissioned)
-10.30.51.13 | softiron-2 (decommissioned)
-10.30.51.14 | softiron-3 (decommissioned)
-10.30.51.15 | LF Reserved
-10.30.51.16 | t1-tg1
-10.30.51.17 | t1-sut1
-10.30.51.18 | t1-sut2
-10.30.51.20 | t2-tg1
-10.30.51.21 | t2-sut1
-10.30.51.22 | t2-sut2
-10.30.51.24 | t3-tg1
-10.30.51.25 | t3-sut1
-10.30.51.26 | t3-sut-2
-10.30.51.28 | s41-nomad
-10.30.51.29 | s39-nomad
-10.30.51.30 | s40-nomad
-10.30.51.32 | s42-nomad
-10.30.51.33 | s43-nomad
-10.30.51.34 | s44-nomad
-10.30.51.35 | s45-nomad
-10.30.51.36 | s17-t33-sut1
-10.30.51.37 | s18-t33-sut2
-10.30.51.38 | fdio-marvell-dev
-10.30.51.39 | s53-nomad
-10.30.51.40 | s54-nomad
-10.30.51.41 | s20-t34-sut1 (decommissioned)
-10.30.51.42 | s21-t34-sut2 (decommissioned)
-10.30.51.43 | fdio-mcbin3 (decommissioned)
-10.30.51.44 | s3-t21-sut1
-10.30.51.45 | s4-t21-tg1
-10.30.51.46 | s11-t31-sut1
-10.30.51.47 | s12-t31-sut2
-10.30.51.48 | s13-t31-tg1
-10.30.51.49 | s19-t33t34-tg1
-10.30.51.50 | s1-t11-sut1
-10.30.51.51 | s2-t12-sut1
-10.30.51.52 | s5-t22-sut1
-10.30.51.53 | s6-t22-tg1
-10.30.51.54 | s7-t23-sut1
-10.30.51.55 | s8-t23-tg1
-10.30.51.56 | s9-t24-sut1
-10.30.51.57 | s10-t24-tg1
-10.30.51.58 | s14-t32-sut1
-10.30.51.59 | s15-t32-sut2
-10.30.51.60 | s16-t32-tg1
-10.30.51.61 | s25-t25-sut1
-10.30.51.62 | s26-t25-tg1
-10.30.51.65 | s52-nomad
-10.30.51.66 | s51-nomad
-10.30.51.67 | s49-nomad
-10.30.51.68 | s50-nomad
-10.30.51.69 | s27-t34-sut1
-10.30.51.70 | s55-t36-sut1
-10.30.51.71 | s56-t37-sut1
-10.30.51.72-10.30.51.105 | FREE
-10.30.51.106-10.30.51.180 | FREE
-10.30.51.181-10.30.51.254 | FREE
-10.30.51.255 | Broadcast
-10.32.8.0 | network
-10.32.8.1 | Router
-10.32.8.10 | s28-t26t35-tg1
-10.32.8.11 | s29-t26-sut1
-10.32.8.12 | s30-t35-sut1
-10.32.8.13 | s31-t35-sut2
-10.32.8.14 | s46-nomad
-10.32.8.15 | s47-nomad
-10.32.8.16 | s48-nomad
-10.32.8.17 | s57-nomad
-10.32.8.18 | s33-t27-sut1
-10.32.8.19 | s34-t27-tg1
-10.32.8.20 | s35-t28-sut1
-10.32.8.21 | s36-t28-tg1
-10.32.8.22 | s37-t29-sut1
-10.32.8.23 | s38-t29-tg1
-10.32.8.24 | s60-t210-sut1
-10.32.8.25 | s61-t210-tg1
-10.32.8.255 | Broadcast
-
-## Server Specifications
-
-### Server Types
-
-FD.io CSIT lab contains following server types:
-```
-1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
- - Quantity: 6 servers.
- - Physical connectivity:
- - CIMC and host management ports.
- - NIC ports connected in 3-node topologies.
- - Main HW configuration:
- - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
- - Processors: 2* E5-2699v3 2.3 GHz.
- - RAM Memory: 16* 32GB DDR4-2133MHz.
- - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
- - NICs configuration:
- - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
- - PCIe Slot1: Cisco VIC 1385 2p40GE.
- - PCIe Slot2: Intel NIC x520 2p10GE.
- - PCIe Slot3: empty.
- - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
- - PCIe Slot4: Intel NIC xl710 2p40GE.
- - PCIe Slot5: Intel NIC x710 2p10GE.
- - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill)
- - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
-2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
- - Quantity: 3 servers.
- - Physical connectivity:
- - CIMC and host management ports.
- - NIC ports connected in 3-node topologies.
- - Main HW configuration:
- - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
- - Processors: 2* E5-2699v3 2.3 GHz.
- - RAM Memory: 16* 32GB DDR4-2133MHz.
- - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
- - NICs configuration:
- - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
- - PCIe Slot1: Intel NIC xl710 2p40GE.
- - PCIe Slot2: Intel NIC x710 2p10GE.
- - PCIe Slot3: Intel NIC x710 2p10GE.
- - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
- - PCIe Slot4: Intel NIC xl710 2p40GE.
- - PCIe Slot5: Intel NIC x710 2p10GE.
- - PCIe Slot6: Intel NIC x710 2p10GE.
- - MLOM slot: empty.
-3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
- - Quantity: 3 servers.
- - Physical connectivity:
- - CIMC and host management ports.
- - no NIC ports, standalone setup.
- - Main HW configuration:
- - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
- - Processors: 2* E5-2699v3 2.3 GHz.
- - RAM Memory: 16* 32GB DDR4-2133MHz.
- - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
- - NICs configuration:
- - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
- - no cards.
- - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
- - no cards.
- - MLOM slot: empty.
-4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
- - Quantity: ---
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 2-node and 3-node topologies.
- - Main HW configuration:
- - Chassis: SuperMicro SYS-7049GP-TRT.
- - Motherboard: SuperMicro X11DPG-QT.
- - Processors: 2* Intel Platinum 8180 2.5 GHz.
- - RAM Memory: 16* 16GB DDR4-2666MHz.
- - Disks: 2* 1.6TB 6G SATA SSD.
- - NICs configuration:
- - Numa0: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
- - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
- - PCIe Slot9 5e:00.xx: empty.
- - Numa1: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot6 86:00.xx: empty.
- - PCIe Slot8 af:00.xx: empty.
- - PCIe Slot10 d8:00.xx: empty.
-5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
- - Quantity: ---
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 2-node and 3-node topologies.
- - Main HW configuration:
- - Chassis: SuperMicro SYS-7049GP-TRT.
- - Motherboard: SuperMicro X11DPG-QT.
- - Processors: 2* Intel Platinum 8180 2.5 GHz.
- - RAM Memory: 16* 16GB DDR4-2666MHz.
- - Disks: 2* 1.6TB 6G SATA SSD.
- - NICs configuration:
- - Numa0: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
- - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
- - PCIe Slot9 5e:00.xx: empty.
- - Numa1: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot6 86:00.xx: empty.
- - PCIe Slot8 af:00.xx: empty.
- - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
-6. Server-Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
- - Quantity: 2
- - Physical connectivity:
- - IPMI(?) and host management ports.
- - NIC ports connected into 3-node topology.
- - Main HW configuration:
- - Chassis: Huawei TaiShan 2280.
- - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72
- - RAM Memory: 8* 16GB DDR4-2400MT/s
- - Disks: 1* 4TB SATA HDD
- - NICs configuration:
- - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
- - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
-7. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
- - Quantity: TBD based on testbed allocation.
- - Physical connectivity:
- - Management: serial Port (usb) for console
- - NIC ports connected into 2-node.
- - Main HW configuration:
- - Chassis: Netgate XG-2758-1u
- - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
- - RAM Memory: 16GB ECC
- - Disks: 150 GB
- - NICs configuration:
- - 2x 10Gb Intel 82599ES
- - 4x 1GB Intel I354
-8. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
- - Quantity: 2.
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 1-node topologies.
- - Main HW configuration:
- - Chassis: SuperMicro SYS-7049GP-TRT.
- - Motherboard: SuperMicro X11DPG-QT.
- - Processors: 2* Intel Platinum 8180 2.5 GHz.
- - RAM Memory: 16* 16GB DDR4-2666MHz.
- - Disks: 2* 1.6TB 6G SATA SSD.
- - NICs configuration:
- - Numa0: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
- - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
- - PCIe Slot9 5e:00.xx: empty.
- - Numa1: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot6 86:00.xx: empty.
- - PCIe Slot8 af:00.xx: empty.
- - PCIe Slot10 d8:00.xx: empty.
-9. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
- - Quantity: 1.
- - Physical connectivity:
- - Host management interface: 10/100/1000-BaseT.
- - 8-port 10GE SFP+ integrated NIC.
- - Main HW configuration:
- - Chassis: PS10GE4NG.
- - Motherboard: SuperMicro X11DPG-QT.
- - Processors: Quad-Core, Intel Processor.
- - HW accelerators: FPGA offload.
- - RAM Memory: 64GB.
- - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
- - Physical Interfaces: 4 * 10GE SFP+.
- - Operating System: Native IxOS.
- - Interface configuration:
- - Port-1: 10GE SFP+.
- - Port-2: 10GE SFP+.
- - Port-3: 10GE SFP+.
- - Port-4: 10GE SFP+.
-10. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
- - Quantity: 1.
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports.
- - Main HW configuration:
- - Chassis: SuperMicro SYS-7049GP-TRT.
- - Motherboard: SuperMicro X11DPG-QT.
- - Processors: 2* Intel Platinum 8180 2.5 GHz.
- - RAM Memory: 16* 16GB DDR4-2666MHz.
- - Disks: 2* 1.6TB 6G SATA SSD.
- - NICs configuration:
- - Numa0: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
- - PCIe Slot4 3b:00.xx: empty.
- - PCIe Slot9 5e:00.xx: empty.
- - Numa1: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot6 86:00.xx: empty.
- - PCIe Slot8 af:00.xx: empty.
- - PCIe Slot10 d8:00.xx: empty.
-11. Server-Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
- - Quantity: 1
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 1-node topologies.
- - Main HW configuration:
- - Chassis: Gigabyte R181-T90 1U
- - Motherboard: MT91-FS1
- - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz
- - RAM Memory: 4* 32GB RDIMM
- - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
- - NICs configuration:
- - Numa0:
- - PCIe Slot6 08:00.xx: XL710-QDA2-2p40GE Intel.
- - Numa1:
- - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
-12. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
- - Quantity: 4
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports.
- - Main HW configuration:
- - Chassis: SuperMicro SYS-E300-9A
- - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
- - RAM Memory: 32GB ECC
- - Disks: 480 GB
- - NICs configuration:
- - 2x 10Gb Intel x553 fiber ports
- - 2x 10Gb Intel x553 copper ports
- - 4x 1GB Intel I350 ports
-13. Server-Type-B11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
- - Quantity: 2
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 1-node topologies.
- - Main HW configuration:
- - Chassis: GIGABYTE Rack Mount
- - Motherboard: MT91-FS4-00
- - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz
- - RAM Memory: 16 * 16GB DIMM
- - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480
- - NICs configuration:
- - Numa0:
- - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel.
- - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox.
- - Numa1:
- - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
- - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
-14. Server-Type-B12: Purpose - Skylake Xeon TG for FD.io performance testing.
- - Quantity: ---
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 2-node and 3-node topologies.
- - Main HW configuration:
- - Chassis: SuperMicro SYS-7049GP-TRT.
- - Motherboard: SuperMicro X11DPG-QT.
- - Processors: 2* Intel Platinum 8180 2.5 GHz.
- - RAM Memory: 16* 16GB DDR4-2666MHz.
- - Disks: 2* 1.6TB 6G SATA SSD.
- - NICs configuration:
- - Numa0: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
- - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
- - PCIe Slot9 5e:00.xx: empty.
- - Numa1: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot6 86:00.xx: empty.
- - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
- - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
-
-15. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
- - Quantity: 1.
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 1-node testbed topologies.
- - Main HW configuration:
- - Chassis: SuperMicro SYS-7049GP-TRT.
- - Motherboard: SuperMicro X11DPG-QT.
- - Processors: 2* Intel Platinum 8280 2.7 GHz.
- - RAM Memory: 12* 16GB DDR4-2933.
- - Disks: 2* 1.92TB SATA SSD.
- - NICs configuration:
- - Numa0: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
- - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
- - PCIe Slot9 5e:00.xx: empty.
- - Numa1: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot6 86:00.xx: empty.
- - PCIe Slot8 af:00.xx: empty.
- - PCIe Slot10 d8:00.xx: empty.
-16. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
- - Quantity: 3
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 2-node testbed topologies.
- - Main HW configuration:
- - Chassis: SuperMicro SYS-7049GP-TRT.
- - Motherboard: SuperMicro X11DPG-QT.
- - Processors: 2* Intel Gold 6252N 2.3 GHz.
- - RAM Memory: 12* 16GB DDR4-2933.
- - Disks: 2* 1.92TB SATA SSD.
- - NICs configuration:
- - Numa0: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
- - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
- - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
- - Numa1: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot6 86:00.xx: empty.
- - PCIe Slot8 af:00.xx: empty.
- - PCIe Slot10 d8:00.xx: empty.
-17. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
- - Quantity: 3.
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 2-node testbed topologies.
- - Main HW configuration:
- - Chassis: SuperMicro SYS-7049GP-TRT.
- - Motherboard: SuperMicro X11DPG-QT.
- - Processors: 2* Intel Platinum 8280 2.7 GHz.
- - RAM Memory: 12* 16GB DDR4-2933.
- - Disks: 2* 1.92TB SATA SSD.
- - NICs configuration:
- - Numa0: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
- - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
- - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
- - Numa1: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot6 86:00.xx: empty.
- - PCIe Slot8 af:00.xx: empty.
- - PCIe Slot10 d8:00.xx: empty.
-18. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
- - Quantity: 3.
- - Physical connectivity:
- - CIMC and host management ports.
- - no NIC ports, standalone setup.
- - Main HW configuration:
- - Chassis: SuperMicro 1029P-WTRT.
- - Motherboard: SuperMicro X11DDW-NT.
- - Processors: 2* Intel Platinum 8280 2.7 GHz.
- - RAM Memory: 12* 16GB DDR4-2933.
- - Disks: 4* 1.92TB SATA SSD.
- - NICs configuration:
- - Numa0:
- - no cards.
- - Numa1:
- - no cards.
-
-19. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
- - Quantity: 1.
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 2-node testbed topologies.
- - Main HW configuration:
- - Chassis: SuperMicro AS-1114S-WTRT
- - Processors: 1* AMD EPYC 7532 2.4 GHz.
- - RAM Memory: 8* 32GB DDR4-2933.
- - Disks: 1* 1TB SATA SSD.
- - NICs configuration:
- - Numa0: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot1 01:00.xx: x710-4p10GE Intel.
- - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
- - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
-20. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
- - Quantity: 1.
- - Physical connectivity:
- - IPMI and host management ports.
- - NIC ports connected into 2-node testbed topologies.
- - Main HW configuration:
- - Chassis: SuperMicro AS-1114S-WTRT
- - Processors: 1* AMD EPYC 7532 2.4 GHz.
- - RAM Memory: 8* 32GB DDR4-2933.
- - Disks: 1* 1TB SATA SSD.
- - NICs configuration:
- - Numa0: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
- - PCIe Slot2 41:00.xx: x710-4p10GE Intel.
- - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
-```
-
-### Naming Convention
-
-Following naming convention is used within this page to specify physical
-connectivity and wiring across defined CSIT testbeds:
-
-```
-- testbedname: testbedN.
-- hostname:
- - traffic-generator: tN-tgW.
- - system-under-testX: tN-sutX.
-- portnames:
- - tN-tgW-cY/pZ.
- - tN-sutX-cY/pZ.
-- where:
- - N - testbed number.
- - tgW - server acts as traffic-generator with W index.
- - sutX - server acts as system-under-test with X index.
- - Y - PCIe slot number denoting a NIC card number within the host.
- - Z - port number on the NIC card.
-```
-
-## Testbeds Configuration
-
-### Per Testbed Server Allocation and Naming
-
-#### 1-Node-Skylake Servers (1n-skx) PROD
-
-```
-- SUT [Server-Type-B6]:
- - testbedname: testbed11.
- - hostname: s1-t11-sut1.
- - IPMI IP: 10.30.50.47
- - Host IP: 10.30.51.50
- - portnames:
- - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
- - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
- - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
- - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
-- SUT [Server-Type-B6]:
- - testbedname: testbed12.
- - hostname: s2-t12-sut1.
- - IPMI IP: 10.30.50.48
- - Host IP: 10.30.51.51
- - portnames:
- - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
- - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
- - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
- - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
-```
-
-#### 1-Node-ThunderX2 Servers (1n-tx2) PROD
-
-```
-- SUT [Server-Type-B11]:
- - testbedname: testbed36
- - hostname: s55-t36-sut1
- - IPMI IP: 10.30.50.70
- - Host IP: 10.30.51.70
- - portnames:
- - s55-t36-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
- - s55-t36-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
- - s55-t36-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
- - s55-t36-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
- - s55-t36-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
- - s55-t36-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
- - s55-t36-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
- - s55-t36-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
-- SUT [Server-Type-B11]:
- - testbedname: testbed37
- - hostname: s56-t37-sut1
- - IPMI IP: 10.30.50.71
- - Host IP: 10.30.51.71
- - portnames:
- - s56-t37-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
- - s56-t37-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
- - s56-t37-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
- - s56-t37-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
- - s56-t37-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
- - s56-t37-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
- - s56-t37-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
- - s56-t37-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
-```
-
-#### 1-Node-Cascadelake Servers (1n-clx) PROD
-
-```
-- SUT [Server-Type-C1]:
- - testbedname: testbed11.
- - hostname: s32-t14-sut1.
- - IPMI IP: 10.30.55.17
- - Host IP: 10.32.8.17
- - portnames:
- - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
- - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
- - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
- - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
-```
-
-#### 2-Node-Skylake Servers (2n-skx) PROD
-
-```
-- SUT [Server-Type-B1]:
- - testbedname: testbed21.
- - hostname: s3-t21-sut1.
- - IPMI IP: 10.30.50.41
- - Host IP: 10.30.51.44
- - portnames:
- - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- TG [Server-Type-B2]:
- - testbedname: testbed21.
- - hostname: s4-t21-tg1.
- - IPMI IP: 10.30.50.42
- - Host IP: 10.30.51.45
- - portnames:
- - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- SUT [Server-Type-B1]:
- - testbedname: testbed22.
- - hostname: s5-t22-sut1.
- - IPMI IP: 10.30.50.49
- - Host IP: 10.30.51.52
- - portnames:
- - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- TG [Server-Type-B2]:
- - testbedname: testbed22.
- - hostname: s6-t22-tg1.
- - IPMI IP: 10.30.50.50
- - Host IP: 10.30.51.53
- - portnames:
- - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- SUT [Server-Type-B1]:
- - testbedname: testbed23.
- - hostname: s7-t23-sut1.
- - IPMI IP: 10.30.50.51
- - Host IP: 10.30.51.54
- - portnames:
- - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- TG [Server-Type-B2]:
- - testbedname: testbed23.
- - hostname: s8-t23-tg1.
- - IPMI IP: 10.30.50.52
- - Host IP: 10.30.51.55
- - portnames:
- - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- SUT [Server-Type-B1]:
- - testbedname: testbed24.
- - hostname: s9-t24-sut1.
- - IPMI IP: 10.30.50.53
- - Host IP: 10.30.51.56
- - portnames:
- - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- TG [Server-Type-B2]:
- - testbedname: testbed24.
- - hostname: s10-t24-tg1.
- - IPMI IP: 10.30.50.54
- - Host IP: 10.30.51.57
- - portnames:
- - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-```
-
-#### 2-Node-Denverton Servers (2n-dnv) WIP
-
-Note: ServerB28 (TG) is shared between testbed26 & testbed35
-
-```
-- TG [Server-Type-B2]:
- - testbednames: testbed26 and testbed35.
- - hostname: s28-t26t35-tg1.
- - IPMI IP: 10.30.55.10
- - Host IP: 10.32.8.10
- - portnames:
- - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE.
- - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE.
- - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE.
- - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE.
- - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE.
- - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE.
- - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE.
- - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE.
- - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE.
- - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE.
- - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE.
- - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE.
-- SUT [Server-Type-B10]:
- - testbednames: testbed26.
- - hostname: s29-t26-sut1.
- - IPMI IP: 10.30.55.11
- - Host IP: 10.32.8.11
- - portnames:
- - s29-t26-sut1-p1 - 10GE-port1 x553 copper port.
- - s29-t26-sut1-p2 - 10GE-port2 x553 copper port.
- - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port.
- - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port.
-```
-
-#### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
-
-```
-- SUT [Server-Type-B8]:
- - testbedname: testbed25.
- - hostname: s25-t25-sut1.
- - IPMI IP: 10.30.50.58
- - Host IP: 10.30.51.61
- - portnames:
- - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
-- TG [Server-Type-B7]:
- - testbedname: testbed25.
- - hostname: s26-t25-tg1.
- - IPMI IP: 10.30.50.59
- - Host IP: 10.30.51.62
- - portnames:
- - s26-t25-tg1-p1 - 10GE-port1.
- - s26-t25-tg1-p2 - 10GE-port2.
- - s26-t25-tg1-p3 - 10GE-port3.
- - s26-t25-tg1-p4 - 10GE-port4.
-```
-
-#### 2-Node-Cascadelake Servers (2n-clx) PROD
-
-```
-- SUT [Server-Type-C2]:
- - testbedname: testbed27.
- - hostname: s33-t27-sut1.
- - IPMI IP: 10.30.55.18
- - Host IP: 10.32.8.18
- - portnames:
- - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s33-t27-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
- - s33-t27-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
- - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
-- TG [Server-Type-C3]:
- - testbedname: testbed27.
- - hostname: s34-t27-tg1.
- - IPMI IP: 10.30.55.19
- - Host IP: 10.32.8.19
- - portnames:
- - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s34-t27-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
- - s34-t27-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
- - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
-- SUT [Server-Type-C2]:
- - testbedname: testbed28.
- - hostname: s35-t28-sut1.
- - IPMI IP: 10.30.55.20
- - Host IP: 10.32.8.20
- - portnames:
- - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s35-t28-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
- - s35-t28-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
- - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
-- TG [Server-Type-C3]:
- - testbedname: testbed28.
- - hostname: s36-t28-tg1.
- - IPMI IP: 10.30.55.21
- - Host IP: 10.32.8.21
- - portnames:
- - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s36-t28-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
- - s36-t28-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
- - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
-- SUT [Server-Type-C2]:
- - testbedname: testbed29.
- - hostname: s37-t29-sut1.
- - IPMI IP: 10.30.55.22
- - Host IP: 10.32.8.22
- - portnames:
- - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s37-t29-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
- - s37-t29-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
- - s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- - s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
-- TG [Server-Type-C3]:
- - testbedname: testbed29.
- - hostname: s38-t29-tg1.
- - IPMI IP: 10.30.55.23
- - Host IP: 10.32.8.23
- - portnames:
- - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s38-t29-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
- - s38-t29-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
- - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
-```
-
-#### 2-Node-Zen2 Servers (2n-zn2) PROD
-
-```
-- SUT [Server-Type-D1]:
- - testbedname: testbed210.
- - hostname: s60-t210-sut1.
- - IPMI IP: 10.30.55.24
- - Host IP: 10.32.8.24
- - portnames:
- - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE.
- - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE.
- - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE.
- - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE.
- - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE.
- - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE.
-- TG [Server-Type-D2]:
- - testbedname: testbed210.
- - hostname: s61-t210-tg1.
- - IPMI IP: 10.30.55.25
- - Host IP: 10.32.8.25
- - portnames:
- - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE.
- - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE.
- - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-```
-
-#### 2-Node-ThunderX2 Servers (2x-tx2) WIP
-
-Note: Server19 (TG) is shared between testbed33 & testbed34
-
-```
-- SUT [Server-Type-B9]:
- - testbedname: testbed34.
- - hostname: s27-t34-sut1.
- - IPMI IP: 10.30.50.69
- - Host IP: 10.30.51.69
- - portnames:
- - s27-t34-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
- - s27-t34-sut1-c6/p2 - 40GE-port1 XL710-QDA2-2p40GE.
- - s27-t34-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE.
- - s27-t34-sut1-c18/p2 - 40GE-port1 XL710-QDA2-2p40GE.
-- TG [Server-Type-B12]:
- - testbedname: testbed33 and testbed34.
- - hostname: s19-t33t34-tg1.
- - IPMI IP: 10.30.50.46
- - Host IP: 10.30.51.49
- - portnames:
- - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s19-t33t34-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
- - s19-t33t34-tg1-c8/p2 - 40GE-port1 xl710-QDA2-2p40GE.
- - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
- - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
- - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
- - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
-```
-
-#### 3-Node-Haswell Servers (3n-hsw) PROD
-
-```
- 1. SUT [Server-Type-A1]:
- - testbedname: testbed1.
- - hostname: t1-sut1.
- - CIMC IP: 10.30.50.17
- - Host IP: 10.30.51.17
- - portnames:
- - t1-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
- - t1-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
- - t1-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
- - t1-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
- - t1-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t1-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t1-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
- - t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 2. SUT [Server-Type-A1]:
- - testbedname: testbed1.
- - hostname: t1-sut2.
- - CIMC IP: 10.30.50.18
- - Host IP: 10.30.51.18
- - portnames:
- - t1-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
- - t1-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
- - t1-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
- - t1-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
- - t1-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t1-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t1-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
- - t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 3. TG [Server-Type-A2]:
- - testbedname: testbed1.
- - hostname: t1-tg1.
- - CIMC IP: 10.30.50.16
- - Host IP: 10.30.51.16
- - portnames:
- - t1-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t1-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t1-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t1-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t1-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t1-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t1-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t1-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t1-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- 4. SUT [Server-Type-A1]:
- - testbedname: testbed2.
- - hostname: t2-sut1.
- - CIMC IP: 10.30.50.21
- - Host IP: 10.30.51.21
- - portnames:
- - t2-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
- - t2-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
- - t2-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
- - t2-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
- - t2-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t2-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t2-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
- - t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 5. SUT [Server-Type-A1]:
- - testbedname: testbed2.
- - hostname: t2-sut2.
- - CIMC IP: 10.30.50.22
- - Host IP: 10.30.51.22
- - portnames:
- - t2-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
- - t2-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
- - t2-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
- - t2-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
- - t2-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t2-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t2-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
- - t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 6. TG [Server-Type-A2]:
- - testbedname: testbed2.
- - hostname: t2-tg1.
- - CIMC IP: 10.30.50.20
- - Host IP: 10.30.51.20
- - portnames:
- - t2-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t2-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t2-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t2-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t2-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t2-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t2-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t2-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t2-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- 7. SUT [Server-Type-A1]:
- - testbedname: testbed3.
- - hostname: t3-sut1.
- - CIMC IP: 10.30.50.25
- - Host IP: 10.30.51.25
- - portnames:
- - t3-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
- - t3-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
- - t3-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
- - t3-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
- - t3-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t3-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t3-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
- - t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 8. SUT [Server-Type-A1]:
- - testbedname: testbed3.
- - hostname: t3-sut2.
- - CIMC IP: 10.30.50.26
- - Host IP: 10.30.51.26
- - portnames:
- - t3-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
- - t3-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
- - t3-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
- - t3-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
- - t3-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t3-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t3-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
- - t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 9. TG [Server-Type-A2]:
- - testbedname: testbed3.
- - hostname: t3-tg1.
- - CIMC IP: 10.30.50.24
- - Host IP: 10.30.51.24
- - portnames:
- - t3-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t3-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t3-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t3-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t3-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t3-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t3-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
- - t3-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
- - t3-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t3-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- - t3-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
- - t3-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-```
-
-#### 3-Node-Skylake Servers (3n-skx) PROD
-
-```
-- ServerB11 [Server-Type-B1]:
- - testbedname: testbed31.
- - hostname: s11-t31-sut1.
- - IPMI IP: 10.30.50.43
- - Host IP: 10.30.51.46
- - portnames:
- - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB12 [Server-Type-B1]:
- - testbedname: testbed31.
- - hostname: s12-t31-sut2.
- - IPMI IP: 10.30.50.44
- - Host IP: 10.30.51.47
- - portnames:
- - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
- - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
- - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
- - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
- - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB13 [Server-Type-B2]:
- - testbedname: testbed31.
- - hostname: s13-t31-tg1.
- - IPMI IP: 10.30.50.45
- - Host IP: 10.30.51.48
- - portnames:
- - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB14 [Server-Type-B1]:
- - testbedname: testbed32.
- - hostname: s14-t32-sut1.
- - IPMI IP: 10.30.50.55
- - Host IP: 10.30.51.58
- - portnames:
- - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB15 [Server-Type-B1]:
- - testbedname: testbed32.
- - hostname: s15-t32-sut2.
- - IPMI IP: 10.30.50.56
- - Host IP: 10.30.51.59
- - portnames:
- - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
- - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
- - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
- - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
- - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB16 [Server-Type-B2]:
- - testbedname: testbed32.
- - hostname: s16-t32-tg1.
- - IPMI IP: 10.30.50.57
- - Host IP: 10.30.51.60
- - portnames:
- - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
- - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-```
-
-#### 3-Node-Rangeley Servers (3n-rng) VERIFY
-
-Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
-
-```
-- ServerB22 [Server-Type-B5]:
- - testbedname: testbed35.
- - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
- - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
- - Host IP: 10.30.51.9
- - portnames:
- - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
- - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
- - 1GB ports (tbd)
-- ServerB23 [Server-Type-B5]:
- - testbedname: testbed35.
- - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
- - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
- - Host IP: 10.30.51.10
- - portnames:
- - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
- - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
- - 1GB ports (tbd)
-- ServerB24 [Server-Type-B5]:
- - testbedname: testbed35.
- - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
- - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
- - Host IP: 10.30.51.11
- - portnames:
- - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
- - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
- - 1GB ports (tbd)
-```
-
-#### 3-Node-Taishan Servers (3n-tsh) PROD
-
-Note: Server19 (TG) is shared between testbed33 & testbed34
-
-```
-- SUT [Server-Type-B3]:
- - testbedname: testbed33.
- - hostname: s17-t33-sut1.
- - IPMI IP: 10.30.50.36
- - Host IP: 10.30.51.36
- - portnames:
- - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
- - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
- - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
- - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
-- SUT [Server-Type-B3]:
- - testbedname: testbed33.
- - hostname: s18-t33-sut2.
- - IPMI IP: 10.30.50.37
- - Host IP: 10.30.51.37
- - portnames:
- - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
- - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
- - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
- - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
-- TG [Server-Type-B12]:
- - testbedname: testbed33 and testbed34.
- - hostname: s19-t33t34-tg1.
- - IPMI IP: 10.30.50.46
- - Host IP: 10.30.51.49
- - portnames:
- - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
- - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
- - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
- - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s19-t33t34-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
- - s19-t33t34-tg1-c8/p2 - 40GE-port1 xl710-QDA2-2p40GE.
- - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
- - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
- - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
- - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
-```
-
-#### 3-Node-Denverton Servers (3n-dnv) WIP
-
-```
-- ServerB30 [Server-Type-B10]:
- - testbednames: testbed35.
- - hostname: s30-t35-sut1.
- - IPMI IP: 10.30.55.12
- - Host IP: 10.32.8.12
- - portnames:
- - s30-t35-sut1-p1 - 10GE-port1 x553 copper port.
- - s30-t35-sut1-p2 - 10GE-port2 x553 copper port.
- - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port.
- - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port.
-- ServerB31 [Server-Type-B10]:
- - testbednames: testbed35.
- - hostname: s31-t35-sut2.
- - IPMI IP: 10.30.55.13
- - Host IP: 10.32.8.13
- - portnames:
- - s31-t35-sut2-p1 - 10GE-port1 x553 copper port.
- - s31-t35-sut2-p2 - 10GE-port2 x553 copper port.
- - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port.
- - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
-```
-
-### Per Testbed Wiring
-
-#### 1-Node-Skylake Wiring (1n-skx) PROD
-
-```
-- testbed11:
- - ring1 10GE-ports x710-4p10GE:
- - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
- - ring2 10GE-ports x710-4p10GE:
- - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
- - ring3 10GE-ports x710-4p10GE:
- - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
- - ring4 10GE-ports x710-4p10GE:
- - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
-- testbed12:
- - ring1 10GE-ports x710-4p10GE:
- - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
- - ring2 10GE-ports x710-4p10GE:
- - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
- - ring3 10GE-ports x710-4p10GE:
- - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
- - ring4 10GE-ports x710-4p10GE:
- - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
-```
-
-#### 1-Node-ThunderX2 Wiring (1n-tx2) PROD
-
-```
-- testbed36:
- - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
- - s55-t36-sut1-c4/p1 - s55-t36-sut1-c14/p1.
- - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
- - s55-t36-sut1-c4/p2 - s55-t36-sut1-c14/p2.
- - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
- - s55-t36-sut1-c8/p1 - s55-t36-sut1-c26/p1.
- - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
- - s55-t36-sut1-c8/p2 - s55-t36-sut1-c26/p2.
-
-- testbed37:
- - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
- - s56-t37-sut1-c4/p1 - s56-t37-sut1-c14/p1.
- - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
- - s56-t37-sut1-c4/p2 - s56-t37-sut1-c14/p2.
- - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
- - s55-t37-sut1-c8/p1 - s55-t37-sut1-c26/p1.
- - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
- - s55-t37-sut1-c8/p2 - s55-t37-sut1-c26/p2.
-```
-
-#### 1-Node-Cascadelake Wiring (1n-clx) PROD
-
-```
-- testbed14:
- - ring1 10GE-ports x710-4p10GE:
- - s32-t14-sut1-c2/p1 to s32-t14-sut1-c4/p1.
- - ring2 10GE-ports x710-4p10GE:
- - s32-t14-sut1-c2/p2 to s32-t14-sut1-c4/p2.
- - ring3 10GE-ports x710-4p10GE:
- - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
- - ring4 10GE-ports x710-4p10GE:
- - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
-```
-
-#### 2-Node-Skylake Wiring (2n-skx) PROD
-
-```
-- testbed21:
- - ring1 10GE-ports x710-4p10GE on SUT:
- - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
- - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
- - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
- - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
-- testbed22:
- - ring1 10GE-ports x710-4p10GE on SUT:
- - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
- - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
- - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
- - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
-- testbed23:
- - ring1 10GE-ports x710-4p10GE on SUT:
- - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
- - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
- - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
- - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
-- testbed24:
- - ring1 10GE-ports x710-4p10GE on SUT:
- - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
- - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
- - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
- - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
-```
-
-#### 2-Node-Denverton Wiring (2n-dnv) WIP
-
-```
-- testbed26:
- - ring1 10GE-ports x553 copper port on SUT:
- - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1.
- - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2.
- - ring2 10GE-ports x553 fiber port on SUT:
- - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3.
- - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4.
-```
-
-#### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
-
-```
-- testbed25:
- - link1 10GE-port x710-4p10GE on SUT:
- - t25-tg1-p1 to t25-sut1-c2/p1.
- - link2 10GE-port x710-4p10GE on SUT:
- - t25-tg1-p2 to t25-sut1-c2/p2.
- - link3 10GE-port x710-4p10GE on SUT:
- - t25-tg1-p3 to t25-sut1-c2/p3.
- - link4 10GE-port x710-4p10GE on SUT:
- - t25-tg1-p4 to t25-sut1-c2/p4.
-```
-
-#### 2-Node-Cascadelake Wiring (2n-clx) PROD
-
-```
-- testbed27:
- - ring1 10GE-ports x710-4p10GE on SUT:
- - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
- - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
- - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
- - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
- - ring4 100GE-ports ConnectX5-2p100GE on SUT:
- - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
- - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
- - ring5 100GE-ports e810-2p100GE on SUT:
- - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1.
- - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2.
-- testbed28:
- - ring1 10GE-ports x710-4p10GE on SUT:
- - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
- - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
- - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
- - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
- - ring4 100GE-ports ConnectX5-2p100GE on SUT:
- - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
- - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
- - ring5 100GE-ports e810-2p100GE on SUT:
- - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1.
- - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2.
-- testbed29:
- - ring1 10GE-ports x710-4p10GE on SUT:
- - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
- - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
- - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
- - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
- - ring4 100GE-ports ConnectX5-2p100GE on SUT:
- - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
- - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
- - ring6 100GE-ports e810-2p100GE on SUT:
- - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1.
- - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2.
-```
-
-#### 2-Node-Zen2 Wiring (2n-zn2) PROD
-
-```
-- testbed210:
- - ring1 10GE-ports x710-4p10GE on SUT:
- - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1.
- - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3.
- - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1.
- - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2.
- - ring4 100GE-ports ConnectX5-2p100GE on SUT:
- - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1.
- - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
-```
-
-#### 2-Node-ThunderX2 Wiring (2n-tx2) WIP
-
-```
-- testbed34:
- - ring1 10GE-ports x520-2p10GE on SUTs:
- - s27-t34-sut1-c18/p1 - s19-t33t34-tg1-c8/p1.
- - s27-t34-sut1-c18/p2 - s19-t33t34-tg1-c8/p2.
-```
-
-
-#### 3-Node-Haswell Wiring (3n-hsw) PROD
-
-```
- 1. testbed1:
- - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
- - t1-tg1-c1/p1 to t1-sut1-c1/p2.
- - t1-sut1-c1/p1 to t1-sut2-c1/p2.
- - t1-sut2-c1/p1 to t1-tg1-c1/p2.
- - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
- - t1-tg1-c2/p1 to t1-sut1-c2/p2.
- - t1-sut1-c2/p1 to t1-sut2-c2/p2.
- - t1-sut2-c2/p1 to t1-tg1-c2/p2.
- - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
- - t1-tg1-c4/p1 to t1-sut1-c4/p2.
- - t1-sut1-c4/p1 to t1-sut2-c4/p2.
- - t1-sut2-c4/p1 to t1-tg1-c4/p2.
- - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
- - t1-tg1-c5/p1 to t1-sut1-c5/p2.
- - t1-sut1-c5/p1 to t1-sut2-c5/p2.
- - t1-sut2-c5/p1 to t1-tg1-c5/p2.
- - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
- - t1-tg1-c2/p1 to t1-sut1-cm/p2.
- - t1-sut1-cm/p1 to t1-sut2-cm/p2.
- - t1-sut2-cm/p1 to t1-tg1-c2/p2.
- - TG loopback ports Intel NIC x710 2p10GE
- - t1-tg1-c6/p1 to t1-tg1-c6/p2.
-
- 2. testbed2:
- - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
- - t2-tg1-c1/p1 to t2-sut1-c1/p2.
- - t2-sut1-c1/p1 to t2-sut2-c1/p2.
- - t2-sut2-c1/p1 to t2-tg1-c1/p2.
- - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
- - t2-tg1-c2/p1 to t2-sut1-c2/p2.
- - t2-sut1-c2/p1 to t2-sut2-c2/p2.
- - t2-sut2-c2/p1 to t2-tg1-c2/p2.
- - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
- - t2-tg1-c4/p1 to t2-sut1-c4/p2.
- - t2-sut1-c4/p1 to t2-sut2-c4/p2.
- - t2-sut2-c4/p1 to t2-tg1-c4/p2.
- - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
- - t2-tg1-c5/p1 to t2-sut1-c5/p2.
- - t2-sut1-c5/p1 to t2-sut2-c5/p2.
- - t2-sut2-c5/p1 to t2-tg1-c5/p2.
- - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
- - t2-tg1-c2/p1 to t2-sut1-cm/p2.
- - t2-sut1-cm/p1 to t2-sut2-cm/p2.
- - t2-sut2-cm/p1 to t2-tg1-c2/p2.
- - TG loopback ports Intel NIC x710 2p10GE
- - t2-tg1-c6/p1 to t2-tg1-c6/p2.
-
- 3. testbed3:
- - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
- - t3-tg1-c1/p1 to t3-sut1-c1/p2.
- - t3-sut1-c1/p1 to t3-sut2-c1/p2.
- - t3-sut2-c1/p1 to t3-tg1-c1/p2.
- - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
- - t3-tg1-c2/p1 to t3-sut1-c2/p2.
- - t3-sut1-c2/p1 to t3-sut2-c2/p2.
- - t3-sut2-c2/p1 to t3-tg1-c2/p2.
- - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
- - t3-tg1-c4/p1 to t3-sut1-c4/p2.
- - t3-sut1-c4/p1 to t3-sut2-c4/p2.
- - t3-sut2-c4/p1 to t3-tg1-c4/p2.
- - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
- - t3-tg1-c5/p1 to t3-sut1-c5/p2.
- - t3-sut1-c5/p1 to t3-sut2-c5/p2.
- - t3-sut2-c5/p1 to t3-tg1-c5/p2.
- - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
- - t3-tg1-c2/p1 to t3-sut1-cm/p2.
- - t3-sut1-cm/p1 to t3-sut2-cm/p2.
- - t3-sut2-cm/p1 to t3-tg1-c2/p2.
- - TG loopback ports Intel NIC x710 2p10GE
- - t3-tg1-c6/p1 to t3-tg1-c6/p2.
-```
-
-#### 3-Node-Skylake Wiring (3n-skx) PROD
-
-```
-- testbed31:
- - ring1 10GE-ports x710-4p10GE on SUTs:
- - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
- - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
- - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
- - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
- - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
- - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
- - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
- - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
- - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
- - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
- - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
- - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
- - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
- - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
-- testbed32:
- - ring1 10GE-ports x710-4p10GE on SUTs:
- - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
- - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
- - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
- - ring2 10GE-ports x710-4p10GE on SUT:
- - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
- - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
- - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
- - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
- - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
- - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
- - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
- - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
- - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
- - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
- - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
- - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
- - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
- - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
-```
-
-#### 3-Node-Rangeley Wiring (3n-rng) TODO
-
-```
-To be completed.
-```
-
-#### 3-Node-Taishan Wiring (3n-tsh) PROD
-
-```
-- testbed33:
- - ring1 10GE-ports x520-2p10GE on SUTs:
- - s19-t33t34-tg1-c2/p2 - s17-t33-sut1-c6/p2.
- - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2.
- - s18-t33-sut2-c6/p1 - s19-t33t34-tg1-c2/p1.
- - ring2 25GE-ports cx4-2p25GE on SUTs:
- - s19-t33t34-tg1-c4/p2 - s17-t33-sut1-c4/p2.
- - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2.
- - s18-t33-sut2-c4/p1 - s19-t33t34-tg1-c4/p1.
-```
-
-#### 3-Node-Denverton Wiring (3n-dnv) WIP
-
-```
-- testbed35:
- - ring1 10GE-ports x553 copper port on SUTs:
- - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2.
- - s30-t35-sut1-p1 to s31-t35-sut2-p1.
- - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2.
- - ring2 10GE-ports x553 fiber port on SUTs:
- - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4.
- - s30-t35-sut1-p3 to s31-t35-sut2-p3.
- - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
-```
-
-## Inventory
-
-### Appliances
-
-```
-1. Ixia PerfectStorm One Appliance
- - 1 * PS10GE4NG
- - Chassis: PS10GE4NG.
- - Motherboard: SuperMicro X11DPG-QT.
- - Processors: Quad-Core, Intel Processor.
- - HW accelerators: FPGA offload.
- - RAM Memory: 64GB.
- - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
- - Physical Interfaces: 4 * 10GE SFP+.
- - Operating System: Native IxOS.
-```
-
-### Arm Servers
-
-```
-1. Arm Cortex A-72 servers
- - 2 * ThunderX2 (VPP Device)
- - Chassis: GIGABYTE Rack Mount
- - Processors: 2* ThunderX2 CN9980 ~ 32* ThunderX2
- - RAM Memory: 16* 16GB DIMM
- - Disks: 2* 480GB 6G SATA SSD SAMSUNG MZ7LH480
- - 1 * ThunderX2 (Performance)
- - Chassis: GIGABYTE Rack Mount
- - Processors: 2* ThunderX2 CN9975 ~ 28* ThunderX2.
- - RAM Memory: 4* 32GB RDIMM
- - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
- - 2 * Huawei TaiShan 2280.
- - Chassis: Huawei TaiShan 2280.
- - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72.
- - RAM Memory: 8* 16GB DDR4-2400MT/s.
- - Disks: 1* 4TB SATA HDD.
-```
-
-### Xeon and Atom Servers
-
-```
-1. Intel Xeon servers:
- - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
- - Chassis: SuperMicro SYS-7049GP-TRT.
- - Motherboard: SuperMicro X11DPG-QT.
- - Processors: 2* Intel Platinum 8180 2.5 GHz.
- - RAM Memory: 16* 16GB DDR4-2666MHz.
- - Disks: 2* 1.6TB 6G SATA SSD.
-2. Intel Atom servers with Rangely processors.
- - 3 * Netgate XG-2758-1u
- - Chassis: Netgate XG-2758-1u
- - Processors: 1* Rangely (Atom) C2758 2.4 GHz
- - RAM Memory: 16GB ECC
- - Disks: 150 GB
-```
-
-### Network Interface Cards
-
-```
-1. 10GE NICs
- - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
- - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
- - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
-2. 25GE NICs
- - 12 * Intel® Ethernet Network Adapter XXV710-DA2
-3. 40GE NICs
- - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
-4. 100GE NICs
- - 4 * mcx556a-edat NICs (not on site yet, in transit)
-```
-
-### Pluggables and Cables
-
-Pluggables:
-
-```
-1. 10GE SFP+
- - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
- - 80 * 10G SR optic (generic, "Intel" compatible branded)
-2. 25GE SFP28
- - None
-3. 40GE QSFP+
- - None
-4. 100GE
- - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
-```
-
-Standalone cables:
-
-```
-1. 10GE
- - None
-2. 25GE
- - None
-3. 40GE QSFP+
- - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable
-4. 100GE
- - None
-```
-
-### Other Parts
-
-None.
diff --git a/docs/lab/testbeds_sm_clx_hw_bios_cfg.md b/docs/lab/testbeds_sm_clx_hw_bios_cfg.md
deleted file mode 100644
index f29ec4272a..0000000000
--- a/docs/lab/testbeds_sm_clx_hw_bios_cfg.md
+++ /dev/null
@@ -1,1453 +0,0 @@
-# SuperMicro Cascadelake Servers - HW and BIOS Configuration
-
-1. [Linux lscpu](#linux-lscpu)
-1. [Linux dmidecode](#dmidecode)
-1. [Linux dmidecode pci](#linux-dmidecode-pci)
-1. [Linux dmidecode memory](#linux-dmidecode-memory)
-1. [Xeon Clx Server BIOS Configuration](#xeon-clx-server-bios-configuration)
- 1. [Boot Feature](#boot-feature)
- 1. [CPU Configuration](#cpu-configuration)
- 1. [Advanced Power Management Configuration](#advanced-power-management-configuration)
- 1. [CPU P State Control](#cpu-p-state-control)
- 1. [Hardware PM State Control](#hardware-pm-state-control)
- 1. [CPU C State Control](#cpu-c-state-control)
- 1. [Package C State Control](#package-c-state-control)
- 1. [CPU T State Control](#cpu-t-state-control)
- 1. [Chipset Configuration](#chipset-configuration)
- 1. [North Bridge](#north-bridge)
- 1. [UPI Configuration](#upi-configuration)
- 1. [Memory Configuration](#memory-configuration)
- 1. [IIO Configuration](#iio-configuration)
- 1. [CPU1 Configuration](#cpu1-configuration)
- 1. [CPU2 Configuration](#cpu2-configuration)
- 1. [South Bridge](#south-bridge)
- 1. [PCIe/PCI/PnP Configuration](#pciepcipnp-configuration)
- 1. [ACPI Settings](#acpi-settings)
-1. [Xeon Clx Server Firmware Inventory](#xeon-clx-server-firmware-inventory)
-
-## Linux lscpu
-
-```
-$ lscpu
-Architecture: x86_64
-CPU op-mode(s): 32-bit, 64-bit
-Byte Order: Little Endian
-CPU(s): 112
-On-line CPU(s) list: 0-111
-Thread(s) per core: 2
-Core(s) per socket: 28
-Socket(s): 2
-NUMA node(s): 2
-Vendor ID: GenuineIntel
-CPU family: 6
-Model: 85
-Model name: Intel(R) Xeon(R) Platinum 8280 CPU @ 2.70GHz
-Stepping: 7
-CPU MHz: 3299.609
-BogoMIPS: 5400.00
-Virtualization: VT-x
-L1d cache: 32K
-L1i cache: 32K
-L2 cache: 1024K
-L3 cache: 39424K
-NUMA node0 CPU(s): 0-27,56-83
-NUMA node1 CPU(s): 28-55,84-111
-Flags: fpu vme de pse tsc msr pae mce cx8 apic sep mtrr pge mca
-cmov pat pse36 clflush dts acpi mmx fxsr sse sse2 ss ht tm pbe syscall nx
-pdpe1gb rdtscp lm constant_tsc art arch_perfmon pebs bts rep_good nopl xtopology
-nonstop_tsc cpuid aperfmperf pni pclmulqdq dtes64 monitor ds_cpl vmx smx est
-tm2 ssse3 sdbg fma cx16 xtpr pdcm pcid dca sse4_1 sse4_2 x2apic movbe popcnt
-tsc_deadline_timer aes xsave avx f16c rdrand lahf_lm abm 3dnowprefetch
-cpuid_fault epb cat_l3 cdp_l3 invpcid_single ssbd mba ibrs ibpb stibp
-ibrs_enhanced tpr_shadow vnmi flexpriority ept vpid fsgsbase tsc_adjust bmi1
-hle avx2 smep bmi2 erms invpcid rtm cqm mpx rdt_a avx512f avx512dq rdseed adx
-smap clflushopt clwb intel_pt avx512cd avx512bw avx512vl xsaveopt xsavec xgetbv1
-xsaves cqm_llc cqm_occup_llc cqm_mbm_total cqm_mbm_local dtherm ida arat pln pts
-pku ospke avx512_vnni md_clear flush_l1d arch_capabilities
-```
-
-```
-$ lscpu
-Architecture: x86_64
-CPU op-mode(s): 32-bit, 64-bit
-Byte Order: Little Endian
-CPU(s): 96
-On-line CPU(s) list: 0-95
-Thread(s) per core: 2
-Core(s) per socket: 24
-Socket(s): 2
-NUMA node(s): 2
-Vendor ID: GenuineIntel
-CPU family: 6
-Model: 85
-Model name: Intel(R) Xeon(R) Gold 6252N CPU @ 2.30GHz
-Stepping: 7
-CPU MHz: 3000.989
-BogoMIPS: 4600.00
-Virtualization: VT-x
-L1d cache: 32K
-L1i cache: 32K
-L2 cache: 1024K
-L3 cache: 36608K
-NUMA node0 CPU(s): 0-23,48-71
-NUMA node1 CPU(s): 24-47,72-95
-Flags: fpu vme de pse tsc msr pae mce cx8 apic sep mtrr pge mca
-cmov pat pse36 clflush dts acpi mmx fxsr sse sse2 ss ht tm pbe syscall nx
-pdpe1gb rdtscp lm constant_tsc art arch_perfmon pebs bts rep_good nopl xtopology
-nonstop_tsc cpuid aperfmperf pni pclmulqdq dtes64 monitor ds_cpl vmx smx est tm2
-ssse3 sdbg fma cx16 xtpr pdcm pcid dca sse4_1 sse4_2 x2apic movbe popcnt
-tsc_deadline_timer aes xsave avx f16c rdrand lahf_lm abm 3dnowprefetch
-cpuid_fault epb cat_l3 cdp_l3 invpcid_single ssbd mba ibrs ibpb stibp
-ibrs_enhanced tpr_shadow vnmi flexpriority ept vpid fsgsbase tsc_adjust bmi1 hle
-avx2 smep bmi2 erms invpcid rtm cqm mpx rdt_a avx512f avx512dq rdseed adx smap
-clflushopt clwb intel_pt avx512cd avx512bw avx512vl xsaveopt xsavec xgetbv1
-xsaves cqm_llc cqm_occup_llc cqm_mbm_total cqm_mbm_local dtherm ida arat pln pts
-pku ospke avx512_vnni md_clear flush_l1d arch_capabilities
-```
-
-## Linux dmidecode
-
-```
- # dmidecode 3.1
- Getting SMBIOS data from sysfs.
- SMBIOS 3.1.2 present.
- Table at 0x6EB92000.
-
- Handle 0x0000, DMI type 0, 26 bytes
- BIOS Information
- Vendor: American Megatrends Inc.
- Version: 3.0c
- Release Date: 03/27/2019
- Address: 0xF0000
- Runtime Size: 64 kB
- ROM Size: 32 MB
- Characteristics:
- PCI is supported
- BIOS is upgradeable
- BIOS shadowing is allowed
- Boot from CD is supported
- Selectable boot is supported
- BIOS ROM is socketed
- EDD is supported
- 5.25"/1.2 MB floppy services are supported (int 13h)
- 3.5"/720 kB floppy services are supported (int 13h)
- 3.5"/2.88 MB floppy services are supported (int 13h)
- Print screen service is supported (int 5h)
- Serial services are supported (int 14h)
- Printer services are supported (int 17h)
- ACPI is supported
- USB legacy is supported
- BIOS boot specification is supported
- Targeted content distribution is supported
- UEFI is supported
- BIOS Revision: 5.14
-
- Handle 0x0001, DMI type 1, 27 bytes
- System Information
- Manufacturer: Supermicro
- Product Name: SYS-7049GP-TRT
- Version: 0123456789
- Serial Number: S291427X9525476
- UUID: 00000000-0000-0000-0000-AC1F6BACD7BA
- Wake-up Type: Power Switch
- SKU Number: To be filled by O.E.M.
- Family: To be filled by O.E.M.
-
- Handle 0x0002, DMI type 2, 15 bytes
- Base Board Information
- Manufacturer: Supermicro
- Product Name: X11DPG-QT
- Version: 1.10A
- Serial Number: VM189S007860
- Asset Tag: To be filled by O.E.M.
- Features:
- Board is a hosting board
- Board is replaceable
- Location In Chassis: To be filled by O.E.M.
- Chassis Handle: 0x0003
- Type: Motherboard
- Contained Object Handles: 0
-
- Handle 0x0003, DMI type 3, 22 bytes
- Chassis Information
- Manufacturer: Supermicro
- Type: Other
- Lock: Not Present
- Version: 0123456789
- Serial Number: C7470KH37A30566
- Asset Tag: To be filled by O.E.M.
- Boot-up State: Safe
- Power Supply State: Safe
- Thermal State: Safe
- Security Status: None
- OEM Information: 0x00000000
- Height: Unspecified
- Number Of Power Cords: 1
- Contained Elements: 0
- SKU Number: To be filled by O.E.M.
-
- Handle 0x0055, DMI type 4, 48 bytes
- Processor Information
- Socket Designation: CPU1
- Type: Central Processor
- Family: Xeon
- Manufacturer: Intel(R) Corporation
- ID: 57 06 05 00 FF FB EB BF
- Signature: Type 0, Family 6, Model 85, Stepping 7
- Flags:
- FPU (Floating-point unit on-chip)
- VME (Virtual mode extension)
- DE (Debugging extension)
- PSE (Page size extension)
- TSC (Time stamp counter)
- MSR (Model specific registers)
- PAE (Physical address extension)
- MCE (Machine check exception)
- CX8 (CMPXCHG8 instruction supported)
- APIC (On-chip APIC hardware supported)
- SEP (Fast system call)
- MTRR (Memory type range registers)
- PGE (Page global enable)
- MCA (Machine check architecture)
- CMOV (Conditional move instruction supported)
- PAT (Page attribute table)
- PSE-36 (36-bit page size extension)
- CLFSH (CLFLUSH instruction supported)
- DS (Debug store)
- ACPI (ACPI supported)
- MMX (MMX technology supported)
- FXSR (FXSAVE and FXSTOR instructions supported)
- SSE (Streaming SIMD extensions)
- SSE2 (Streaming SIMD extensions 2)
- SS (Self-snoop)
- HTT (Multi-threading)
- TM (Thermal monitor supported)
- PBE (Pending break enabled)
- Version: Intel(R) Xeon(R) Gold 6252N CPU @ 2.30GHz
- Voltage: 1.6 V
- External Clock: 100 MHz
- Max Speed: 4500 MHz
- Current Speed: 2300 MHz
- Status: Populated, Enabled
- Upgrade: Socket LGA3647-1
- L1 Cache Handle: 0x0052
- L2 Cache Handle: 0x0053
- L3 Cache Handle: 0x0054
- Serial Number: Not Specified
- Asset Tag: UNKNOWN
- Part Number: Not Specified
- Core Count: 24
- Core Enabled: 24
- Thread Count: 48
- Characteristics:
- 64-bit capable
- Multi-Core
- Hardware Thread
- Execute Protection
- Enhanced Virtualization
- Power/Performance Control
-
- Handle 0x0059, DMI type 4, 48 bytes
- Processor Information
- Socket Designation: CPU2
- Type: Central Processor
- Family: Xeon
- Manufacturer: Intel(R) Corporation
- ID: 57 06 05 00 FF FB EB BF
- Signature: Type 0, Family 6, Model 85, Stepping 7
- Flags:
- FPU (Floating-point unit on-chip)
- VME (Virtual mode extension)
- DE (Debugging extension)
- PSE (Page size extension)
- TSC (Time stamp counter)
- MSR (Model specific registers)
- PAE (Physical address extension)
- MCE (Machine check exception)
- CX8 (CMPXCHG8 instruction supported)
- APIC (On-chip APIC hardware supported)
- SEP (Fast system call)
- MTRR (Memory type range registers)
- PGE (Page global enable)
- MCA (Machine check architecture)
- CMOV (Conditional move instruction supported)
- PAT (Page attribute table)
- PSE-36 (36-bit page size extension)
- CLFSH (CLFLUSH instruction supported)
- DS (Debug store)
- ACPI (ACPI supported)
- MMX (MMX technology supported)
- FXSR (FXSAVE and FXSTOR instructions supported)
- SSE (Streaming SIMD extensions)
- SSE2 (Streaming SIMD extensions 2)
- SS (Self-snoop)
- HTT (Multi-threading)
- TM (Thermal monitor supported)
- PBE (Pending break enabled)
- Version: Intel(R) Xeon(R) Gold 6252N CPU @ 2.30GHz
- Voltage: 1.6 V
- External Clock: 100 MHz
- Max Speed: 4500 MHz
- Current Speed: 2300 MHz
- Status: Populated, Enabled
- Upgrade: Socket LGA3647-1
- L1 Cache Handle: 0x0056
- L2 Cache Handle: 0x0057
- L3 Cache Handle: 0x0058
- Serial Number: Not Specified
- Asset Tag: UNKNOWN
- Part Number: Not Specified
- Core Count: 24
- Core Enabled: 24
- Thread Count: 48
- Characteristics:
- 64-bit capable
- Multi-Core
- Hardware Thread
- Execute Protection
- Enhanced Virtualization
- Power/Performance Control
-```
-
-## Linux dmidecode pci
-
-```
- $ dmidecode -t slot
- Handle 0x000B, DMI type 9, 17 bytes
- System Slot Information
- Designation: CPU1 SLOT2 PCI-E 3.0 X16
- Type: x16 PCI Express 3 x16
- Current Usage: In Use
- Length: Long
- ID: 2
- Characteristics:
- 3.3 V is provided
- Opening is shared
- PME signal is supported
- Bus Address: 0000:18:00.0
-
- Handle 0x000C, DMI type 9, 17 bytes
- System Slot Information
- Designation: CPU1 SLOT4 PCI-E 3.0 X16
- Type: x16 PCI Express 3 x16
- Current Usage: In Use
- Length: Short
- ID: 4
- Characteristics:
- 3.3 V is provided
- Opening is shared
- PME signal is supported
- Bus Address: 0000:3b:00.0
-
- Handle 0x000D, DMI type 9, 17 bytes
- System Slot Information
- Designation: CPU2 SLOT6 PCI-E 3.0 X16
- Type: x16 PCI Express 3 x16
- Current Usage: Available
- Length: Short
- ID: 6
- Characteristics:
- 3.3 V is provided
- Opening is shared
- PME signal is supported
- Bus Address: 0000:ff:00.0
-
- Handle 0x000E, DMI type 9, 17 bytes
- System Slot Information
- Designation: CPU2 SLOT8 PCI-E 3.0 X16
- Type: x16 PCI Express 3 x16
- Current Usage: Available
- Length: Short
- ID: 8
- Characteristics:
- 3.3 V is provided
- Opening is shared
- PME signal is supported
- Bus Address: 0000:ff:00.0
-
- Handle 0x000F, DMI type 9, 17 bytes
- System Slot Information
- Designation: CPU1 SLOT9 PCI-E 3.0 X16
- Type: x16 PCI Express 3 x16
- Current Usage: Available
- Length: Short
- ID: 9
- Characteristics:
- 3.3 V is provided
- Opening is shared
- PME signal is supported
- Bus Address: 0000:ff:00.0
-
- Handle 0x0010, DMI type 9, 17 bytes
- System Slot Information
- Designation: CPU2 SLOT10 PCI-E 3.0 X16
- Type: x16 PCI Express 3 x16
- Current Usage: Available
- Length: Short
- ID: 10
- Characteristics:
- 3.3 V is provided
- Opening is shared
- PME signal is supported
- Bus Address: 0000:ff:00.0
-
- Handle 0x0011, DMI type 9, 17 bytes
- System Slot Information
- Designation: CPU2 SLOT11 PCI-E 3.0 X4(IN X8)
- Type: x4 PCI Express 3 x8
- Current Usage: Available
- Length: Short
- ID: 11
- Characteristics:
- 3.3 V is provided
- Opening is shared
- PME signal is supported
- Bus Address: 0000:ff:00.0
-
- Handle 0x0012, DMI type 9, 17 bytes
- System Slot Information
- Designation: M.2 CONNECTOR
- Type: x4 M.2 Socket 2
- Current Usage: Available
- Length: Short
- Characteristics:
- 3.3 V is provided
- Opening is shared
- PME signal is supported
- Bus Address: 0000:ff:00.0
-```
-
-## Linux dmidecode memory
-
-```
- $ dmidecode -t memory
- Handle 0x0021, DMI type 16, 23 bytes
- Physical Memory Array
- Location: System Board Or Motherboard
- Use: System Memory
- Error Correction Type: Single-bit ECC
- Maximum Capacity: 2304 GB
- Error Information Handle: Not Provided
- Number Of Devices: 4
-
- Handle 0x0023, DMI type 17, 84 bytes
- Memory Device
- Array Handle: 0x0021
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 16384 MB
- Form Factor: DIMM
- Set: None
- Locator: P1-DIMMA1
- Bank Locator: P0_Node0_Channel0_Dimm0
- Type: DDR4
- Type Detail: Synchronous
- Speed: 2933 MT/s
- Manufacturer: SK Hynix
- Serial Number: 93275F0E
- Asset Tag: P1-DIMMA1_AssetTag (date:19/22)
- Part Number: HMA82GR7CJR8N-WM
- Rank: 2
- Configured Clock Speed: 2934 MT/s
- Minimum Voltage: 1.2 V
- Maximum Voltage: 1.2 V
- Configured Voltage: 1.2 V
-
- Handle 0x0024, DMI type 17, 84 bytes
- Memory Device
- Array Handle: 0x0021
- Error Information Handle: Not Provided
- Total Width: Unknown
- Data Width: Unknown
- Size: No Module Installed
- Form Factor: DIMM
- Set: None
- Locator: P1-DIMMA2
- Bank Locator: P0_Node0_Channel0_Dimm1
- Type: Unknown
- Type Detail: Unknown
- Speed: Unknown
- Manufacturer: NO DIMM
- Serial Number: NO DIMM
- Asset Tag: NO DIMM
- Part Number: NO DIMM
- Rank: Unknown
- Configured Clock Speed: Unknown
- Minimum Voltage: 1.2 V
- Maximum Voltage: 1.2 V
- Configured Voltage: 1.2 V
-
- Handle 0x0025, DMI type 17, 84 bytes
- Memory Device
- Array Handle: 0x0021
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 16384 MB
- Form Factor: DIMM
- Set: None
- Locator: P1-DIMMB1
- Bank Locator: P0_Node0_Channel1_Dimm0
- Type: DDR4
- Type Detail: Synchronous
- Speed: 2933 MT/s
- Manufacturer: SK Hynix
- Serial Number: 93275F1F
- Asset Tag: P1-DIMMB1_AssetTag (date:19/22)
- Part Number: HMA82GR7CJR8N-WM
- Rank: 2
- Configured Clock Speed: 2934 MT/s
- Minimum Voltage: 1.2 V
- Maximum Voltage: 1.2 V
- Configured Voltage: 1.2 V
-
- Handle 0x0027, DMI type 17, 84 bytes
- Memory Device
- Array Handle: 0x0021
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 16384 MB
- Form Factor: DIMM
- Set: None
- Locator: P1-DIMMC1
- Bank Locator: P0_Node0_Channel2_Dimm0
- Type: DDR4
- Type Detail: Synchronous
- Speed: 2933 MT/s
- Manufacturer: SK Hynix
- Serial Number: 93275F07
- Asset Tag: P1-DIMMC1_AssetTag (date:19/22)
- Part Number: HMA82GR7CJR8N-WM
- Rank: 2
- Configured Clock Speed: 2934 MT/s
- Minimum Voltage: 1.2 V
- Maximum Voltage: 1.2 V
- Configured Voltage: 1.2 V
-
- Handle 0x002B, DMI type 17, 84 bytes
- Memory Device
- Array Handle: 0x0029
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 16384 MB
- Form Factor: DIMM
- Set: None
- Locator: P1-DIMMD1
- Bank Locator: P0_Node1_Channel0_Dimm0
- Type: DDR4
- Type Detail: Synchronous
- Speed: 2933 MT/s
- Manufacturer: SK Hynix
- Serial Number: 93275F02
- Asset Tag: P1-DIMMD1_AssetTag (date:19/22)
- Part Number: HMA82GR7CJR8N-WM
- Rank: 2
- Configured Clock Speed: 2934 MT/s
- Minimum Voltage: 1.2 V
- Maximum Voltage: 1.2 V
- Configured Voltage: 1.2 V
-
- Handle 0x002C, DMI type 17, 84 bytes
- Memory Device
- Array Handle: 0x0029
- Error Information Handle: Not Provided
- Total Width: Unknown
- Data Width: Unknown
- Size: No Module Installed
- Form Factor: DIMM
- Set: None
- Locator: P1-DIMMD2
- Bank Locator: P0_Node1_Channel0_Dimm1
- Type: Unknown
- Type Detail: Unknown
- Speed: Unknown
- Manufacturer: NO DIMM
- Serial Number: NO DIMM
- Asset Tag: NO DIMM
- Part Number: NO DIMM
- Rank: Unknown
- Configured Clock Speed: Unknown
- Minimum Voltage: 1.2 V
- Maximum Voltage: 1.2 V
- Configured Voltage: 1.2 V
-
- Handle 0x002D, DMI type 17, 84 bytes
- Memory Device
- Array Handle: 0x0029
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 16384 MB
- Form Factor: DIMM
- Set: None
- Locator: P1-DIMME1
- Bank Locator: P0_Node1_Channel1_Dimm0
- Type: DDR4
- Type Detail: Synchronous
- Speed: 2933 MT/s
- Manufacturer: SK Hynix
- Serial Number: 93275F19
- Asset Tag: P1-DIMME1_AssetTag (date:19/22)
- Part Number: HMA82GR7CJR8N-WM
- Rank: 2
- Configured Clock Speed: 2934 MT/s
- Minimum Voltage: 1.2 V
- Maximum Voltage: 1.2 V
- Configured Voltage: 1.2 V
-
- Handle 0x002F, DMI type 17, 84 bytes
- Memory Device
- Array Handle: 0x0029
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 16384 MB
- Form Factor: DIMM
- Set: None
- Locator: P1-DIMMF1
- Bank Locator: P0_Node1_Channel2_Dimm0
- Type: DDR4
- Type Detail: Synchronous
- Speed: 2933 MT/s
- Manufacturer: SK Hynix
- Serial Number: 93275FD3
- Asset Tag: P1-DIMMF1_AssetTag (date:19/22)
- Part Number: HMA82GR7CJR8N-WM
- Rank: 2
- Configured Clock Speed: 2934 MT/s
- Minimum Voltage: 1.2 V
- Maximum Voltage: 1.2 V
- Configured Voltage: 1.2 V
-
- Handle 0x0031, DMI type 16, 23 bytes
- Physical Memory Array
- Location: System Board Or Motherboard
- Use: System Memory
- Error Correction Type: Single-bit ECC
- Maximum Capacity: 2304 GB
- Error Information Handle: Not Provided
- Number Of Devices: 4
-
- Handle 0x0033, DMI type 17, 84 bytes
- Memory Device
- Array Handle: 0x0031
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 16384 MB
- Form Factor: DIMM
- Set: None
- Locator: P2-DIMMA1
- Bank Locator: P1_Node0_Channel0_Dimm0
- Type: DDR4
- Type Detail: Synchronous
- Speed: 2933 MT/s
- Manufacturer: SK Hynix
- Serial Number: 93275FE2
- Asset Tag: P2-DIMMA1_AssetTag (date:19/22)
- Part Number: HMA82GR7CJR8N-WM
- Rank: 2
- Configured Clock Speed: 2934 MT/s
- Minimum Voltage: 1.2 V
- Maximum Voltage: 1.2 V
- Configured Voltage: 1.2 V
-
- Handle 0x0034, DMI type 17, 84 bytes
- Memory Device
- Array Handle: 0x0031
- Error Information Handle: Not Provided
- Total Width: Unknown
- Data Width: Unknown
- Size: No Module Installed
- Form Factor: DIMM
- Set: None
- Locator: P2-DIMMA2
- Bank Locator: P1_Node0_Channel0_Dimm1
- Type: Unknown
- Type Detail: Unknown
- Speed: Unknown
- Manufacturer: NO DIMM
- Serial Number: NO DIMM
- Asset Tag: NO DIMM
- Part Number: NO DIMM
- Rank: Unknown
- Configured Clock Speed: Unknown
- Minimum Voltage: 1.2 V
- Maximum Voltage: 1.2 V
- Configured Voltage: 1.2 V
-
- Handle 0x0035, DMI type 17, 84 bytes
- Memory Device
- Array Handle: 0x0031
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 16384 MB
- Form Factor: DIMM
- Set: None
- Locator: P2-DIMMB1
- Bank Locator: P1_Node0_Channel1_Dimm0
- Type: DDR4
- Type Detail: Synchronous
- Speed: 2933 MT/s
- Manufacturer: SK Hynix
- Serial Number: 93276001
- Asset Tag: P2-DIMMB1_AssetTag (date:19/22)
- Part Number: HMA82GR7CJR8N-WM
- Rank: 2
- Configured Clock Speed: 2934 MT/s
- Minimum Voltage: 1.2 V
- Maximum Voltage: 1.2 V
- Configured Voltage: 1.2 V
-
- Handle 0x0037, DMI type 17, 84 bytes
- Memory Device
- Array Handle: 0x0031
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 16384 MB
- Form Factor: DIMM
- Set: None
- Locator: P2-DIMMC1
- Bank Locator: P1_Node0_Channel2_Dimm0
- Type: DDR4
- Type Detail: Synchronous
- Speed: 2933 MT/s
- Manufacturer: SK Hynix
- Serial Number: 93276005
- Asset Tag: P2-DIMMC1_AssetTag (date:19/22)
- Part Number: HMA82GR7CJR8N-WM
- Rank: 2
- Configured Clock Speed: 2934 MT/s
- Minimum Voltage: 1.2 V
- Maximum Voltage: 1.2 V
- Configured Voltage: 1.2 V
-
- Handle 0x0039, DMI type 16, 23 bytes
- Physical Memory Array
- Location: System Board Or Motherboard
- Use: System Memory
- Error Correction Type: Single-bit ECC
- Maximum Capacity: 2304 GB
- Error Information Handle: Not Provided
- Number Of Devices: 4
-
- Handle 0x003B, DMI type 17, 84 bytes
- Memory Device
- Array Handle: 0x0039
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 16384 MB
- Form Factor: DIMM
- Set: None
- Locator: P2-DIMMD1
- Bank Locator: P1_Node1_Channel0_Dimm0
- Type: DDR4
- Type Detail: Synchronous
- Speed: 2933 MT/s
- Manufacturer: SK Hynix
- Serial Number: 93275F44
- Asset Tag: P2-DIMMD1_AssetTag (date:19/22)
- Part Number: HMA82GR7CJR8N-WM
- Rank: 2
- Configured Clock Speed: 2934 MT/s
- Minimum Voltage: 1.2 V
- Maximum Voltage: 1.2 V
- Configured Voltage: 1.2 V
-
- Handle 0x003C, DMI type 17, 84 bytes
- Memory Device
- Array Handle: 0x0039
- Error Information Handle: Not Provided
- Total Width: Unknown
- Data Width: Unknown
- Size: No Module Installed
- Form Factor: DIMM
- Set: None
- Locator: P2-DIMMD2
- Bank Locator: P1_Node1_Channel0_Dimm1
- Type: Unknown
- Type Detail: Unknown
- Speed: Unknown
- Manufacturer: NO DIMM
- Serial Number: NO DIMM
- Asset Tag: NO DIMM
- Part Number: NO DIMM
- Rank: Unknown
- Configured Clock Speed: Unknown
- Minimum Voltage: 1.2 V
- Maximum Voltage: 1.2 V
- Configured Voltage: 1.2 V
-
- Handle 0x003D, DMI type 17, 84 bytes
- Memory Device
- Array Handle: 0x0039
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 16384 MB
- Form Factor: DIMM
- Set: None
- Locator: P2-DIMME1
- Bank Locator: P1_Node1_Channel1_Dimm0
- Type: DDR4
- Type Detail: Synchronous
- Speed: 2933 MT/s
- Manufacturer: SK Hynix
- Serial Number: 93275FDF
- Asset Tag: P2-DIMME1_AssetTag (date:19/22)
- Part Number: HMA82GR7CJR8N-WM
- Rank: 2
- Configured Clock Speed: 2934 MT/s
- Minimum Voltage: 1.2 V
- Maximum Voltage: 1.2 V
- Configured Voltage: 1.2 V
-
- Handle 0x003F, DMI type 17, 84 bytes
- Memory Device
- Array Handle: 0x0039
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 16384 MB
- Form Factor: DIMM
- Set: None
- Locator: P2-DIMMF1
- Bank Locator: P1_Node1_Channel2_Dimm0
- Type: DDR4
- Type Detail: Synchronous
- Speed: 2933 MT/s
- Manufacturer: SK Hynix
- Serial Number: 93275FDD
- Asset Tag: P2-DIMMF1_AssetTag (date:19/22)
- Part Number: HMA82GR7CJR8N-WM
- Rank: 2
- Configured Clock Speed: 2934 MT/s
- Minimum Voltage: 1.2 V
- Maximum Voltage: 1.2 V
- Configured Voltage: 1.2 V
-```
-
-## Xeon CLX Server BIOS Configuration - TG
-
-### Boot Feature
-
-```
- | Quiet Boot [Enabled] |Boot option |
- | | |
- | Option ROM Messages [Force BIOS] | |
- | Bootup NumLock State [On] | |
- | Wait For "F1" If Error [Enabled] | |
- | INT19 Trap Response [Immediate] | |
- | Re-try Boot [Disabled] | |
- | Install Windows 7 USB support [Disabled] | |
- | Port 61h Bit-4 Emulation [Disabled] | |
- | | |
- | Power Configuration | |
- | Watch Dog Function [Disabled] | |
- | Restore on AC Power Loss [Last State] | |
- | Power Button Function [Instant Off] | |
-```
-
-### CPU Configuration
-
-```
- | Processor Configuration ^|Enables Hyper Threading |
- | -------------------------------------------------- *|(Software Method to |
- | Processor BSP Revision 50657 - CLX B1 *|Enable/Disable Logical |
- | Processor Socket CPU1 | CPU2 *|Processor threads. |
- | Processor ID 00050657* | 00050657 *| |
- | Processor Frequency 2.700GHz | 2.700GHz *| |
- | Processor Max Ratio 1BH | 1BH *| |
- | Processor Min Ratio 0AH | 0AH *| |
- | Microcode Revision 0500002C | 0500002C *| |
- | L1 Cache RAM 64KB | 64KB *| |
- | L2 Cache RAM 1024KB | 1024KB *| |
- | L3 Cache RAM 39424KB | 39424KB *| |
- | Processor 0 Version *| |
- | Intel(R) Xeon(R) Platinum 8280 CPU @ 2.70GHz *| |
- | Processor 1 Version *| |
- | Intel(R) Xeon(R) Platinum 8280 CPU @ 2.70GHz *| |
- | *|-----------------------------|
- | Hyper-Threading [ALL] [Enable] *|><: Select Screen |
- | Cores Enabled 0 *|^v: Select Item |
- | Monitor/Mwait [Auto] *|Enter: Select |
- | Execute Disable Bit [Enable] +|+/-: Change Opt. |
- | Intel Virtualization Technology [Enable] +|F1: General Help |
- | PPIN Control [Unlock/Enable] +|F2: Previous Values |
- | Hardware Prefetcher [Enable] +|F3: Optimized Defaults |
- | Adjacent Cache Prefetch [Enable] v|F4: Save & Exit |
- | DCU Streamer Prefetcher [Enable] | |
- | DCU IP Prefetcher [Enable] | |
- | LLC Prefetch [Disable] | |
- | Extended APIC [Disable] | |
- | AES-NI [Enable] | |
- |> Advanced Power Management Configuration | |
-```
-
-#### Advanced Power Management Configuration
-
-```
- | Advanced Power Management Configuration |Switch CPU Power Management |
- | -------------------------------------------------- |profile |
- | Power Technology [Custom] | |
- | Power Performance Tuning [BIOS Controls EPB] | |
- | ENERGY_PERF_BIAS_CFG mode [Maximum Performance] | |
- |> CPU P State Control | |
- |> Hardware PM State Control | |
- |> CPU C State Control | |
- |> Package C State Control | |
- |> CPU T State Control | |
-```
-
-##### CPU P State Control
-
-```
- | CPU P State Control |EIST allows the processor |
- | |to dynamically adjust |
- | SpeedStep (P-States) [Disable] |frequency and voltage based |
- | EIST PSD Function [HW_ALL] |on power versus performance |
- | |needs. |
- | | |
-```
-
-##### Hardware PM State Control
-
-```
- | Hardware PM State Control |If set to Disable, hardware ^|
- | |will choose a P-state *|
- | Hardware P-States [Disable] |setting for the system *|
- | |based on an OS request. *|
- | |If set to Native Mode, *|
- | |hardware will choose a *|
- | |P-state setting based on OS *|
- | |guidance. *|
- | |If set to Native Mode with *|
- | |No Legacy Support, hardware *|
- | |will choose a P-state *|
- | |setting independently *|
- | |without OS guidance. +|
- | |If set to Out of Band Mode, +|
- | |hardware autonomously v|
-```
-
-##### CPU C State Control
-
-```
- | CPU C State Control |Select Enable to support |
- | |Autonomous Core C-State |
- | Autonomous Core C-State [Disable] |control which will allow |
- | CPU C6 report [Disable] |the processor core to |
- | Enhanced Halt State (C1E) [Disable] |control its C-State setting |
- | |automatically and |
- | |independently. |
-```
-
-##### Package C State Control
-
-```
- | Package C State Control |Limit the lowest package |
- | |level C-State to |
- | Package C State [C0/C1 state] |processors. Lower package |
- | |C-State lower processor |
- | |power consumption upon idle. |
-```
-
-##### CPU T State Control
-
-```
- | CPU T State Control |Enable/Disable CPU |
- | |throttling by OS. |
- | Software Controlled T-States [Disable] |Throttling reduces power |
- | |consumption |
-```
-
-#### Chipset Configuration
-
-```
- | WARNING: Setting wrong values in below sections may cause |North Bridge Parameters |
- | system to malfunction. | |
- |> North Bridge | |
- |> South Bridge | |
-```
-
-##### North Bridge
-
-```
- |> UPI Configuration |Displays and provides |
- |> Memory Configuration |option to change the UPI |
- |> IIO Configuration |Settings |
-```
-
-##### UPI Configuration
-
-```
- | UPI Configuration |Use this feature to select |
- | -------------------------------------------------- |the degrading precedence |
- | Number of CPU 2 |option for Ultra Path |
- | Number of Active UPI Link 3 |Interconnect connections. |
- | Current UPI Link Speed Fast |Select Topology Precedent |
- | Current UPI Link Frequency 10.4 GT/s |to degrade UPI features if |
- | UPI Global MMIO Low Base / Limit 90000000 / FBFFFFFF |system options are in |
- | UPI Global MMIO High Base / Limit 0000000000000000 / |conflict. Select Feature |
- | 00000000FFFFFFFF |Precedent to degrade UPI |
- | UPI Pci-e Configuration Base / Size 80000000 / 10000000 |topology if system options |
- | Degrade Precedence [Topology Precedence] |are in conflict. |
- | Link L0p Enable [Disable] | |
- | Link L1 Enable [Disable] | |
- | IO Directory Cache (IODC) [Auto] | |
- | SNC [Disable] | |
- | XPT Prefetch [Disable] | |
- | KTI Prefetch [Enable] |-----------------------------|
- | Local/Remote Threshold [Auto] |><: Select Screen |
- | Stale AtoS [Auto] |^v: Select Item |
- | LLC Dead Line Alloc [Enable] |Enter: Select |
- | Isoc Mode [Auto] |+/-: Change Opt. |
-```
-
-##### Memory Configuration
-
-```
- | |Select POR to enforce POR |
- | -------------------------------------------------- |restrictions for DDR4 |
- | Integrated Memory Controller (iMC) |frequency and voltage |
- | -------------------------------------------------- |programming |
- | | |
- | Enforce POR [POR] | |
- | PPR Type [Hard PPR] | |
- | Enhanced PPR [Disable] | |
- | Operation Mode [Test and Repair] | |
- | Memory Frequency [2933] | |
- | Data Scrambling for DDR4 [Auto] | |
- | tCCD_L Relaxation [Auto] | |
- | tRWSR Relaxation [Disable] | |
- | tRFC Optimization for 16Gb Based DIMM [Force 550ns] | |
- | 2x Refresh [Auto] | |
- | Page Policy [Auto] | |
- | IMC Interleaving [2-way Interleave] |-----------------------------|
- |> Memory Topology |><: Select Screen |
- |> Memory RAS Configuration |^v: Select Item |
-```
-
-##### IIO Configuration
-
-```
- | IIO Configuration |Expose IIO DFX devices and |
- | -------------------------------------------------- |other CPU devices like PMON |
- | | |
- | EV DFX Features [Disable] | |
- |> CPU1 Configuration | |
- |> CPU2 Configuration | |
- |> IOAT Configuration | |
- |> Intel. VT for Directed I/O (VT-d) | |
- |> Intel. VMD technology | |
- | | |
- | IIO-PCIE Express Global Options | |
- | ======================================== | |
- | PCI-E Completion Timeout Disable [No] | |
-```
-
-##### CPU1 Configuration
-
-```
- | IOU0 (IIO PCIe Br1) [Auto] |Selects PCIe port |
- | IOU1 (IIO PCIe Br2) [Auto] |Bifurcation for selected |
- | IOU2 (IIO PCIe Br3) [Auto] |slot(s) |
- |> CPU1 SLOT2 PCI-E 3.0 X16 | |
- |> CPU1 SLOT4 PCI-E 3.0 X16 | |
- |> CPU1 SLOT9 PCI-E 3.0 X16 | |
-```
-
-##### CPU2 Configuration
-
-```
- | IOU0 (IIO PCIe Br1) [Auto] |Selects PCIe port |
- | IOU1 (IIO PCIe Br2) [Auto] |Bifurcation for selected |
- | IOU2 (IIO PCIe Br3) [Auto] |slot(s) |
- |> CPU2 SLOT6 PCI-E 3.0 X16 | |
- |> CPU2 SLOT8 PCI-E 3.0 X16 | |
- |> CPU2 SLOT10 PCI-E 3.0 X16 | |
-```
-
-#### South Bridge
-
-```
- | |Enables Legacy USB support. |
- | USB Module Version 21 |AUTO option disables legacy |
- | |support if no USB devices |
- | USB Devices: |are connected. DISABLE |
- | 1 Keyboard, 1 Mouse, 1 Hub |option will keep USB |
- | |devices available only for |
- | Legacy USB Support [Enabled] |EFI applications. |
- | XHCI Hand-off [Enabled] | |
- | Port 60/64 Emulation [Enabled] | |
- | PCIe PLL SSC [Disable] | |
- | Real USB Wake Up [Enabled] | |
- | Front USB Wake Up [Enabled] | |
- | | |
- | Azalia [Auto] | |
- | Azalia PME Enable [Disabled] | |
-```
-
-### PCIe/PCI/PnP Configuration
-
-```
- | PCI Bus Driver Version A5.01.18 ^|Enables or Disables 64bit |
- | *|capable Devices to be |
- | PCI Devices Common Settings: *|Decoded in Above 4G Address |
- | Above 4G Decoding [Enabled] *|Space (Only if System |
- | SR-IOV Support [Enabled] *|Supports 64 bit PCI |
- | ARI Support [Enabled] *|Decoding). |
- | MMIO High Base [56T] *| |
- | MMIO High Granularity Size [256G] *| |
- | Maximum Read Request [Auto] *| |
- | MMCFG Base [2G] *| |
- | NVMe Firmware Source [Vendor Defined *| |
- | Firmware] *| |
- | VGA Priority [Onboard] *| |
- | CPU1 SLOT2 PCI-E 3.0 X16 OPROM [Legacy] *| |
- | CPU1 SLOT4 PCI-E 3.0 X16 OPROM [Legacy] *| |
- | CPU2 SLOT6 PCI-E 3.0 X16 OPROM [Legacy] *| |
- | CPU2 SLOT8 PCI-E 3.0 X16 OPROM [Legacy] *|-----------------------------|
- | CPU1 SLOT9 PCI-E 3.0 X16 OPROM [Legacy] *|><: Select Screen |
- | CPU2 SLOT10 PCI-E 3.0 X16 OPROM [Legacy] *|^v: Select Item |
- | CPU2 SLOT11 PCI-E 3.0 X4(IN X8) OPROM [Legacy] *|Enter: Select |
- | M.2 CONNECTOR OPROM [Legacy] *|+/-: Change Opt. |
- | Bus Master Enable [Enabled] +|F1: General Help |
- | Onboard LAN1 Option ROM [Legacy] +|F2: Previous Values |
- | Onboard LAN2 Option ROM [Disabled] +|F3: Optimized Defaults |
- | Onboard Video Option ROM [Legacy] v|F4: Save & Exit |
- |> Network Stack Configuration | |
-```
-
-### ACPI Settings
-
-```
- | ACPI Settings |Enable or Disable Non |
- | |uniform Memory Access |
- | NUMA [Enabled] |(NUMA). |
- | WHEA Support [Enabled] | |
- | High Precision Event Timer [Enabled] | |
-```
-
-## Xeon CLX Server BIOS Configuration - DUT
-
-### Boot Feature
-
-```
- | Quiet Boot [Enabled] |Boot option |
- | | |
- | Option ROM Messages [Force BIOS] | |
- | Bootup NumLock State [On] | |
- | Wait For "F1" If Error [Enabled] | |
- | INT19 Trap Response [Immediate] | |
- | Re-try Boot [Disabled] | |
- | Install Windows 7 USB support [Disabled] | |
- | Port 61h Bit-4 Emulation [Disabled] | |
- | | |
- | Power Configuration | |
- | Watch Dog Function [Disabled] | |
- | Restore on AC Power Loss [Last State] | |
- | Power Button Function [Instant Off] | |
-```
-
-### CPU Configuration
-
-```
- |--------------------------------------------------------------------+-----------------------------\
- | Processor Configuration ^|Enables Hyper Threading |
- | -------------------------------------------------- *|(Software Method to |
- | Processor BSP Revision 50657 - CLX B1 *|Enable/Disable Logical |
- | Processor Socket CPU1 | CPU2 *|Processor threads. |
- | Processor ID 00050657* | 00050657 *| |
- | Processor Frequency 2.300GHz | 2.300GHz *| |
- | Processor Max Ratio 17H | 17H *| |
- | Processor Min Ratio 0AH | 0AH *| |
- | Microcode Revision 0500002C | 0500002C *| |
- | L1 Cache RAM 64KB | 64KB *| |
- | L2 Cache RAM 1024KB | 1024KB *| |
- | L3 Cache RAM 36608KB | 36608KB *| |
- | Processor 0 Version *| |
- | Intel(R) Xeon(R) Gold 6252N CPU @ 2.30GHz *| |
- | Processor 1 Version *| |
- | Intel(R) Xeon(R) Gold 6252N CPU @ 2.30GHz *| |
- | *|-----------------------------|
- | Hyper-Threading [ALL] [Enable] *|><: Select Screen |
- | Cores Enabled 0 *|^v: Select Item |
- | Monitor/Mwait [Auto] *|Enter: Select |
- | Execute Disable Bit [Enable] +|+/-: Change Opt. |
- | Intel Virtualization Technology [Enable] +|F1: General Help |
- | PPIN Control [Unlock/Enable] +|F2: Previous Values |
- | Hardware Prefetcher [Enable] +|F3: Optimized Defaults |
- | Adjacent Cache Prefetch [Enable] v|F4: Save & Exit |
- | DCU Streamer Prefetcher [Enable] | |
- | DCU IP Prefetcher [Enable] | |
- | LLC Prefetch [Disable] | |
- | Extended APIC [Disable] | |
- | AES-NI [Enable] | |
- |> Advanced Power Management Configuration | |
-```
-
-#### Advanced Power Management Configuration
-
-```
- | Advanced Power Management Configuration |Switch CPU Power Management |
- | -------------------------------------------------- |profile |
- | Power Technology [Custom] | |
- | Power Performance Tuning [BIOS Controls EPB] | |
- | ENERGY_PERF_BIAS_CFG mode [Maximum Performance] | |
- |> CPU P State Control | |
- |> Hardware PM State Control | |
- |> CPU C State Control | |
- |> Package C State Control | |
- |> CPU T State Control | |
-```
-
-##### CPU P State Control
-
-```
- | CPU P State Control |EIST allows the processor |
- | |to dynamically adjust |
- | SpeedStep (P-States) [Disable] |frequency and voltage based |
- | Activate PBF [Disable] |on power versus performance |
- | Configure PBF [Enable] |needs. |
- | EIST PSD Function [HW_ALL] | |
-```
-
-##### Hardware PM State Control
-
-```
- | Hardware PM State Control |If set to Disable, hardware ^|
- | |will choose a P-state *|
- | Hardware P-States [Disable] |setting for the system *|
- | |based on an OS request. *|
- | |If set to Native Mode, *|
- | |hardware will choose a *|
- | |P-state setting based on OS *|
- | |guidance. *|
- | |If set to Native Mode with *|
- | |No Legacy Support, hardware *|
- | |will choose a P-state *|
- | |setting independently *|
- | |without OS guidance. +|
- | |If set to Out of Band Mode, +|
- | |hardware autonomously v|
-```
-
-##### CPU C State Control
-
-```
- | CPU C State Control |Select Enable to support |
- | |Autonomous Core C-State |
- | Autonomous Core C-State [Disable] |control which will allow |
- | CPU C6 report [Disable] |the processor core to |
- | Enhanced Halt State (C1E) [Disable] |control its C-State setting |
- | |automatically and |
- | |independently. |
-```
-
-##### Package C State Control
-
-```
- | Package C State Control |Limit the lowest package |
- | |level C-State to |
- | Package C State [C0/C1 state] |processors. Lower package |
- | |C-State lower processor |
- | |power consumption upon idle. |
-```
-
-##### CPU T State Control
-
-```
- | CPU T State Control |Enable/Disable CPU |
- | |throttling by OS. |
- | Software Controlled T-States [Disable] |Throttling reduces power |
- | |consumption |
-```
-
-#### Chipset Configuration
-
-```
- | WARNING: Setting wrong values in below sections may cause |North Bridge Parameters |
- | system to malfunction. | |
- |> North Bridge | |
- |> South Bridge | |
-```
-
-##### North Bridge
-
-```
- |> UPI Configuration |Displays and provides |
- |> Memory Configuration |option to change the UPI |
- |> IIO Configuration |Settings |
-```
-
-##### UPI Configuration
-
-```
- | UPI Configuration |Use this feature to select |
- | -------------------------------------------------- |the degrading precedence |
- | Number of CPU 2 |option for Ultra Path |
- | Number of Active UPI Link 3 |Interconnect connections. |
- | Current UPI Link Speed Fast |Select Topology Precedent |
- | Current UPI Link Frequency 10.4 GT/s |to degrade UPI features if |
- | UPI Global MMIO Low Base / Limit 90000000 / FBFFFFFF |system options are in |
- | UPI Global MMIO High Base / Limit 0000000000000000 / |conflict. Select Feature |
- | 00000000FFFFFFFF |Precedent to degrade UPI |
- | UPI Pci-e Configuration Base / Size 80000000 / 10000000 |topology if system options |
- | Degrade Precedence [Topology Precedence] |are in conflict. |
- | Link L0p Enable [Disable] | |
- | Link L1 Enable [Disable] | |
- | IO Directory Cache (IODC) [Auto] | |
- | SNC [Disable] | |
- | XPT Prefetch [Disable] | |
- | KTI Prefetch [Enable] |-----------------------------|
- | Local/Remote Threshold [Auto] |><: Select Screen |
- | Stale AtoS [Auto] |^v: Select Item |
- | LLC Dead Line Alloc [Enable] |Enter: Select |
- | Isoc Mode [Auto] |+/-: Change Opt. |
-```
-
-##### Memory Configuration
-
-```
- | |Select POR to enforce POR |
- | -------------------------------------------------- |restrictions for DDR4 |
- | Integrated Memory Controller (iMC) |frequency and voltage |
- | -------------------------------------------------- |programming |
- | | |
- | Enforce POR [POR] | |
- | PPR Type [Hard PPR] | |
- | Enhanced PPR [Disable] | |
- | Operation Mode [Test and Repair] | |
- | Memory Frequency [2933] | |
- | Data Scrambling for DDR4 [Auto] | |
- | tCCD_L Relaxation [Auto] | |
- | tRWSR Relaxation [Disable] | |
- | tRFC Optimization for 16Gb Based DIMM [Force 550ns] | |
- | 2x Refresh [Auto] | |
- | Page Policy [Auto] | |
- | IMC Interleaving [2-way Interleave] |-----------------------------|
- |> Memory Topology |><: Select Screen |
- |> Memory RAS Configuration |^v: Select Item |
-```
-
-##### IIO Configuration
-
-```
- | IIO Configuration |Expose IIO DFX devices and |
- | -------------------------------------------------- |other CPU devices like PMON |
- | | |
- | EV DFX Features [Disable] | |
- |> CPU1 Configuration | |
- |> CPU2 Configuration | |
- |> IOAT Configuration | |
- |> Intel. VT for Directed I/O (VT-d) | |
- |> Intel. VMD technology | |
- | | |
- | IIO-PCIE Express Global Options | |
- | ======================================== | |
- | PCI-E Completion Timeout Disable [No] | |
-```
-
-##### CPU1 Configuration
-
-```
- | IOU0 (IIO PCIe Br1) [Auto] |Selects PCIe port |
- | IOU1 (IIO PCIe Br2) [Auto] |Bifurcation for selected |
- | IOU2 (IIO PCIe Br3) [Auto] |slot(s) |
- |> CPU1 SLOT2 PCI-E 3.0 X16 | |
- |> CPU1 SLOT4 PCI-E 3.0 X16 | |
- |> CPU1 SLOT9 PCI-E 3.0 X16 | |
-```
-
-##### CPU2 Configuration
-
-```
- | IOU0 (IIO PCIe Br1) [Auto] |Selects PCIe port |
- | IOU1 (IIO PCIe Br2) [Auto] |Bifurcation for selected |
- | IOU2 (IIO PCIe Br3) [Auto] |slot(s) |
- |> CPU2 SLOT6 PCI-E 3.0 X16 | |
- |> CPU2 SLOT8 PCI-E 3.0 X16 | |
- |> CPU2 SLOT10 PCI-E 3.0 X16 | |
-```
-
-#### South Bridge
-
-```
- | |Enables Legacy USB support. |
- | USB Module Version 21 |AUTO option disables legacy |
- | |support if no USB devices |
- | USB Devices: |are connected. DISABLE |
- | 1 Keyboard, 1 Mouse, 1 Hub |option will keep USB |
- | |devices available only for |
- | Legacy USB Support [Enabled] |EFI applications. |
- | XHCI Hand-off [Enabled] | |
- | Port 60/64 Emulation [Enabled] | |
- | PCIe PLL SSC [Disable] | |
- | Real USB Wake Up [Enabled] | |
- | Front USB Wake Up [Enabled] | |
- | | |
- | Azalia [Auto] | |
- | Azalia PME Enable [Disabled] | |
-```
-
-### PCIe/PCI/PnP Configuration
-
-```
- | PCI Bus Driver Version A5.01.18 ^|Enables or Disables 64bit |
- | *|capable Devices to be |
- | PCI Devices Common Settings: *|Decoded in Above 4G Address |
- | Above 4G Decoding [Enabled] *|Space (Only if System |
- | SR-IOV Support [Enabled] *|Supports 64 bit PCI |
- | ARI Support [Enabled] *|Decoding). |
- | MMIO High Base [56T] *| |
- | MMIO High Granularity Size [256G] *| |
- | Maximum Read Request [Auto] *| |
- | MMCFG Base [2G] *| |
- | NVMe Firmware Source [Vendor Defined *| |
- | Firmware] *| |
- | VGA Priority [Onboard] *| |
- | CPU1 SLOT2 PCI-E 3.0 X16 OPROM [Legacy] *| |
- | CPU1 SLOT4 PCI-E 3.0 X16 OPROM [Legacy] *| |
- | CPU2 SLOT6 PCI-E 3.0 X16 OPROM [Legacy] *| |
- | CPU2 SLOT8 PCI-E 3.0 X16 OPROM [Legacy] *|-----------------------------|
- | CPU1 SLOT9 PCI-E 3.0 X16 OPROM [Legacy] *|><: Select Screen |
- | CPU2 SLOT10 PCI-E 3.0 X16 OPROM [Legacy] *|^v: Select Item |
- | CPU2 SLOT11 PCI-E 3.0 X4(IN X8) OPROM [Legacy] *|Enter: Select |
- | M.2 CONNECTOR OPROM [Legacy] *|+/-: Change Opt. |
- | Bus Master Enable [Enabled] +|F1: General Help |
- | Onboard LAN1 Option ROM [Legacy] +|F2: Previous Values |
- | Onboard LAN2 Option ROM [Disabled] +|F3: Optimized Defaults |
- | Onboard Video Option ROM [Legacy] v|F4: Save & Exit |
- |> Network Stack Configuration | |
-```
-
-### ACPI Settings
-
-```
- | ACPI Settings |Enable or Disable Non |
- | |uniform Memory Access |
- | NUMA [Enabled] |(NUMA). |
- | WHEA Support [Enabled] | |
- | High Precision Event Timer [Enabled] | |
-```
-
-
-## Xeon Clx Server Firmware Inventory
-
-```
-Host. IPMI IP. BMC. BIOS. CPLD. CPU Microcode. PCI Bus. X710 Firmware. XXV710 Firmware. i40e. MLX5 Firmware. mlx5_core
-s32-t14-sut1. 10.30.55.17. 1.67. 3.0c. 03.B1.05. 0500002C. A5.01.18. 6.01 0x800034af 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k. N/A. N/A.
-s33-t27-sut1. 10.30.55.18. 1.67. 3.2. 03.B1.05. 0500002C. A5.01.18. 6.01 0x800034af 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k. 16.25.1020. 4.6.-1.0.1.
-s34-t27-tg1. 10.30.55.19. 1.67. 3.2. 03.B1.05. 0500002C. A5.01.18. 6.01 0x800034af 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k. 16.25.1020. 4.6.-1.0.1.
-s35-t28-sut1. 10.30.55.20. 1.67. 3.2. 03.B1.05. 0500002C. A5.01.18. 6.01 0x800034af 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k. 16.25.1020. 4.6.-1.0.1.
-s36-t28-tg1. 10.30.55.21. 1.67. 3.2. 03.B1.05. 0500002C. A5.01.18. 6.01 0x800034af 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k. 16.25.1020. 4.6.-1.0.1.
-s37-t29-sut1. 10.30.55.22. 1.67. 3.2. 03.B1.05. 0500002C. A5.01.18. 6.01 0x800034af 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k. 16.25.1020. 4.6.-1.0.1.
-s38-t29-tg1. 10.30.55.23. 1.67. 3.2. 03.B1.05. 0500002C. A5.01.18. 6.01 0x800034af 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k. 16.25.1020. 4.6.-1.0.1.
-```
diff --git a/docs/lab/testbeds_sm_dnv_hw_bios_cfg.md b/docs/lab/testbeds_sm_dnv_hw_bios_cfg.md
deleted file mode 100644
index bdddd2f037..0000000000
--- a/docs/lab/testbeds_sm_dnv_hw_bios_cfg.md
+++ /dev/null
@@ -1,351 +0,0 @@
-# SuperMicro Denverton Servers - HW and BIOS Configuration
-
-1. [Linux lscpu](#linux-lscpu)
-1. [Linux dmidecode](#dmidecode)
-1. [Atom Dnv Server BIOS Configuration](#atom-dnv-server-bios-configuration)
- 1. [Boot Feature](#boot-feature)
- 1. [CPU Configuration](#cpu-configuration)
- 1. [Chipset Configuration](#chipset-configuration)
- 1. [North Bridge Configuration](#north-bridge-configuration)
- 1. [South Bridge Configuration](#south-bridge-configuration)
- 1. [PCIe/PCI/PnP Configuration](#pciepcipnp-configuration)
- 1. [ACPI Settings](#acpi-settings)
-1. [Atom Dnv Server Firmware Inventory](#atom-dnv-server-firmware-inventory)
-
-## Linux lscpu
-
-```
-$ lscpu
-Architecture: x86_64
-CPU op-mode(s): 32-bit, 64-bit
-Byte Order: Little Endian
-CPU(s): 12
-On-line CPU(s) list: 0-11
-Thread(s) per core: 1
-Core(s) per socket: 12
-Socket(s): 1
-NUMA node(s): 1
-Vendor ID: GenuineIntel
-CPU family: 6
-Model: 95
-Model name: Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
-Stepping: 1
-CPU MHz: 2000.000
-CPU max MHz: 2000.0000
-CPU min MHz: 800.0000
-BogoMIPS: 4000.00
-Virtualization: VT-x
-L1d cache: 24K
-L1i cache: 32K
-L2 cache: 2048K
-NUMA node0 CPU(s): 0-11
-Flags: fpu vme de pse tsc msr pae mce cx8 apic sep mtrr pge mca
-cmov pat pse36 clflush dts acpi mmx fxsr sse sse2 ss ht tm pbe syscall nx
-pdpe1gb rdtscp lm constant_tsc art arch_perfmon pebs bts rep_good nopl xtopology
-nonstop_tsc cpuid aperfmperf tsc_known_freq pni pclmulqdq dtes64 monitor ds_cpl
-vmx est tm2 ssse3 sdbg cx16 xtpr pdcm sse4_1 sse4_2 x2apic movbe popcnt
-tsc_deadline_timer aes xsave rdrand lahf_lm 3dnowprefetch cpuid_fault epb cat_l2
-ssbd ibrs ibpb stibp tpr_shadow vnmi flexpriority ept vpid ept_ad fsgsbase
-tsc_adjust smep erms mpx rdt_a rdseed smap clflushopt intel_pt sha_ni xsaveopt
-xsavec xgetbv1 xsaves dtherm arat pln pts md_clear arch_capabilities
-
-```
-
-### Linux dmidecode
-
-```
- # dmidecode 3.1
- Getting SMBIOS data from sysfs.
- SMBIOS 3.0.0 present.
- Table at 0x7F0C8000.
-
- Handle 0x0000, DMI type 0, 24 bytes
- BIOS Information
- Vendor: American Megatrends Inc.
- Version: 1.0b
- Release Date: 12/12/2017
- Address: 0xF0000
- Runtime Size: 64 kB
- ROM Size: 16 MB
- Characteristics:
- PCI is supported
- BIOS is upgradeable
- BIOS shadowing is allowed
- Boot from CD is supported
- Selectable boot is supported
- BIOS ROM is socketed
- EDD is supported
- 5.25"/1.2 MB floppy services are supported (int 13h)
- 3.5"/720 kB floppy services are supported (int 13h)
- 3.5"/2.88 MB floppy services are supported (int 13h)
- Print screen service is supported (int 5h)
- Serial services are supported (int 14h)
- Printer services are supported (int 17h)
- ACPI is supported
- USB legacy is supported
- BIOS boot specification is supported
- Targeted content distribution is supported
- UEFI is supported
- BIOS Revision: 5.13
-
- Handle 0x0001, DMI type 1, 27 bytes
- System Information
- Manufacturer: Supermicro
- Product Name: SYS-E300-9A
- Version: 0123456789
- Serial Number: S292431X8616427
- UUID: 03000200-0400-0500-0006-0CC47AFCCA92
- Wake-up Type: Power Switch
- SKU Number: To be filled by O.E.M.
- Family: To be filled by O.E.M.
-
- Handle 0x0002, DMI type 2, 15 bytes
- Base Board Information
- Manufacturer: Supermicro
- Product Name: A2SDi-TP8F
- Version: 1.10
- Serial Number: OM184S023953
- Asset Tag: To be filled by O.E.M.
- Features:
- Board is a hosting board
- Board is replaceable
- Location In Chassis: To be filled by O.E.M.
- Chassis Handle: 0x0003
- Type: Motherboard
- Contained Object Handles: 0
-
- Handle 0x0003, DMI type 3, 22 bytes
- Chassis Information
- Manufacturer: Supermicro
- Type: Other
- Lock: Not Present
- Version: 0123456789
- Serial Number: CE300AG39040925
- Asset Tag: To be filled by O.E.M.
- Boot-up State: Safe
- Power Supply State: Safe
- Thermal State: Safe
- Security Status: None
- OEM Information: 0x00000000
- Height: Unspecified
- Number Of Power Cords: 1
- Contained Elements: 0
- SKU Number: To be filled by O.E.M.
-
- Handle 0x0028, DMI type 4, 48 bytes
- Processor Information
- Socket Designation: CPU
- Type: Central Processor
- Family: Atom
- Manufacturer: Intel(R) Corporation
- ID: F1 06 05 00 FF FB EB BF
- Signature: Type 0, Family 6, Model 95, Stepping 1
- Flags:
- FPU (Floating-point unit on-chip)
- VME (Virtual mode extension)
- DE (Debugging extension)
- PSE (Page size extension)
- TSC (Time stamp counter)
- MSR (Model specific registers)
- PAE (Physical address extension)
- MCE (Machine check exception)
- CX8 (CMPXCHG8 instruction supported)
- APIC (On-chip APIC hardware supported)
- SEP (Fast system call)
- MTRR (Memory type range registers)
- PGE (Page global enable)
- MCA (Machine check architecture)
- CMOV (Conditional move instruction supported)
- PAT (Page attribute table)
- PSE-36 (36-bit page size extension)
- CLFSH (CLFLUSH instruction supported)
- DS (Debug store)
- ACPI (ACPI supported)
- MMX (MMX technology supported)
- FXSR (FXSAVE and FXSTOR instructions supported)
- SSE (Streaming SIMD extensions)
- SSE2 (Streaming SIMD extensions 2)
- SS (Self-snoop)
- HTT (Multi-threading)
- TM (Thermal monitor supported)
- PBE (Pending break enabled)
- Version: Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
- Voltage: 1.6 V
- External Clock: 100 MHz
- Max Speed: 3800 MHz
- Current Speed: 2000 MHz
- Status: Populated, Enabled
- Upgrade: Other
- L1 Cache Handle: 0x0026
- L2 Cache Handle: 0x0027
- L3 Cache Handle: Not Provided
- Serial Number: Not Specified
- Asset Tag: UNKNOWN
- Part Number: Not Specified
- Core Count: 12
- Core Enabled: 12
- Thread Count: 12
- Characteristics:
- 64-bit capable
- Multi-Core
- Hardware Thread
- Execute Protection
- Enhanced Virtualization
- Power/Performance Control
-```
-
-## Atom Dnv Server BIOS Configuration
-
-### Boot Feature
-
-```
- | Quiet Boot [Enabled] |Enable or disable to |
- | |display graphic logo during |
- | Bootup NumLock State [On] |POST |
- | Wait For "F1" If Error [Enabled] | |
- | | |
- | Power Configuration | |
- | Watch Dog Function [Disabled] | |
- | Power Button Function [Instant Off] | |
- | Restore on AC Power Loss [Power On] | |
-```
-
-### CPU Configuration
-
-```
- | CPU Configuration |Enable/Disable EIST. GV3 |
- | |and TM1 must be enabled for |
- | Intel(R) Atom(TM) CPU C3858 @ 2.00GHz |TM2 to be available. GV3 |
- | Processor ID 000506F1 |must be enabled for Turbo. |
- | Microcode Revision 00000020 |Auto - Enable for B0 CPU |
- | Processor Frequency 2.000GHz |stepping, all others |
- | CPU BCLK Frequency 100MHZ |disabled, change setting to |
- | L1 Cache RAM 56KB |override. |
- | L2 Cache RAM 12288KB | |
- | | |
- | EIST (GV3) [Enable] | |
- | BIOS Request Frequency [Enable] | |
- | TM1 [Enable] | |
- | TM2 Mode [Adaptive Throttling] | |
- | Dynamic Self Refresh [Disable] | |
- | CPU C State [Disable] | |
- | Package C State Limit [No Limit] | |
- | Max Core C-State [C6] | |
- | Enhanced Hait State (C1E) [Enable] | |
- | Monitor/Mwait [Enable] | |
- | L1 Prefetcher [Enable] | |
- | L1 Prefetcher [Enable] | |
- | ACPI 3.0 T-States [Disable] | |
- | Max CPUID Value Limit [Disable] | |
- | Execute Disable Bit [Enable] | |
- | Virtualization Technology [Enable] | |
- | Extended APIC [Enable] | |
- | AES-NI [Enable] | |
- | Lock PACKAGE_RAPL_LIMIT [Disable] | |
- | PL1 Time Window 45 | |
- | PL1 Power Level 25 | |
- | PL2 Power Level 29 | |
- | Active Processor Cores 0 | |
-```
-
-### Chipset Configuration
-
-```
- | WARNING: Setting wrong values in below sections may cause |North Bridge Parameters |
- | system to malfunction. | |
- |> North Bridge Configuration | |
- |> South Bridge Configuration | |
-```
-
-#### North Bridge Configuration
-
-```
- | North Bridge Configuration |COption to Ebable / Disable |
- | |VT-d |
- | Memory Information | |
- | MRC Version 0.149.4.43 | |
- | Total Memory 32768 MB | |
- | Memory Frequency DDR4 - 2400 MHZ | |
- | | |
- | VT-d [Enabled] | |
- | VT-d Interrupt remapping [Enabled] | |
- | | |
- | Fast Boot [Enabled] | |
- | Command Address Parity [Disabled] | |
- | Memory Frequency [DDR-2400] | |
- | MMIO Size / BMBOUND Base [Auto] | |
- | TCL performance [Enabled] | |
- | Memory Preservation [Disabled] | |
- | Patrol scrub Enable [Enabled] | |
- | Patrol scrub Period [24 hours] | |
- | Demand Scrub Enable [Enabled] | |
- | Write Data Early Enble [Disabled] | |
- | Select Refresh Rate [1x/2x] | |
- | CKE Power Down [Disabled] | |
- | Memory Thermal Throttling [Disabled] | |
- | Scrambler [Enabled] | |
- | Slow Power Down Exit [Enabled] | |
-```
-
-#### South Bridge Configuration
-
-```
- | South Bridge Configuration |Enables Legacy USB support. |
- | |AUTO option disables legacy |
- | USB Module Version 19 |support if no USB devices |
- | USB Controllers: |are connected. DISABLE |
- | 1 XHCI |option will keep USB |
- | USB Devices: |devices available only for |
- | 2 Keyboards, 1 Mouse, 3 Hubs |EFI applications. |
- | | |
- | Legacy USB Support [Enabled] | |
- | XHCI Hand-off [Enabled] | |
- | Port 60/64 Emulation [Enabled] | |
-
-```
-
-### PCIe/PCI/PnP Configuration
-
-```
- | PCI Bus Driver Version A5.01.12 |Enables or Disables 64bit |
- | |capable Devices to be |
- | PCI Devices Common Settings: |Decoded in Above 4G Address |
- | Above 4G Decoding [Enabled] |Space (Only if System |
- | SR-IOV Support [Enabled] |Supports 64 bit PCI |
- | Maximum Payload [Auto] |Decoding). |
- | Maximum Read Request [Auto] | |
- | ASPM Support [Disabled] | |
- | ARI Forwarding [Disabled] | |
- | | |
- | RSC-RR1U-E8 OPROM [EFI] | |
- | M.2 PCI-E 3.0 X4 OPROM [EFI] | |
- | Mini PCI-E OPROM [EFI] | |
- | | |
- | Onboard LAN OPROM Type [EFI] | |
- | | |
- | Onboard Video OPROM [EFI] | |
- | VGA Priority [Onboard] | |
- | | |
- | Network Stack [Enabled] | |
- | IPv4 PXE Support [Enabled] | |
- | IPv6 PXE Support [Disabled] | |
- | PXE boot wait time 0 | |
- | Media detect count 1 | |
-```
-
-### ACPI Settings
-
-```
- | ACPI Settings |Enable/Disable WHEA ACPI |
- | |support |
- | WHEA Support [Enabled] | |
-```
-
-## Atom Dnv Server Firmware Inventory
-
-```
-Host. IPMI IP. BMC. BIOS. CPU Microcode. PCI Bus. ME Operation FW. X553 Firmware. ixgbe.
-s29-t26-sut1. 10.30.55.11. 3.60. 1.0b. 0x2e. A5.01.12. 4.0.4.139. 0x8000083f 5.1.0-k
-s30-t35-sut1. 10.30.55.12. 3.60. 1.0b. 0x2e. A5.01.12. 4.0.4.139. 0x8000083f 5.1.0-k
-s31-t35-sut2. 10.30.55.13. 3.60. 1.0b. 0x2e. A5.01.12. 4.0.4.139. 0x8000083f 5.1.0-k
-```
diff --git a/docs/lab/testbeds_sm_skx_hw_bios_cfg.md b/docs/lab/testbeds_sm_skx_hw_bios_cfg.md
deleted file mode 100644
index 83167d5d2b..0000000000
--- a/docs/lab/testbeds_sm_skx_hw_bios_cfg.md
+++ /dev/null
@@ -1,577 +0,0 @@
-# SuperMicro Skylake Servers - HW and BIOS Configuration
-
-1. [Linux lscpu](#linux-lscpu)
-1. [Linux dmidecode](#dmidecode)
-1. [Xeon Skx Server BIOS Configuration](#xeon-skx-server-bios-configuration)
- 1. [Boot Feature](#boot-feature)
- 1. [CPU Configuration](#cpu-configuration)
- 1. [Advanced Power Management Configuration](#advanced-power-management-configuration)
- 1. [CPU P State Control](#cpu-p-state-control)
- 1. [Hardware PM State Control](#hardware-pm-state-control)
- 1. [CPU C State Control](#cpu-c-state-control)
- 1. [Package C State Control](#package-c-state-control)
- 1. [CPU T State Control](#cpu-t-state-control)
- 1. [Chipset Configuration](#chipset-configuration)
- 1. [North Bridge](#north-bridge)
- 1. [UPI Configuration](#upi-configuration)
- 1. [Memory Configuration](#memory-configuration)
- 1. [IIO Configuration](#iio-configuration)
- 1. [CPU1 Configuration](#cpu1-configuration)
- 1. [CPU2 Configuration](#cpu2-configuration)
- 1. [South Bridge](#south-bridge)
- 1. [PCIe/PCI/PnP Configuration](#pciepcipnp-configuration)
- 1. [ACPI Settings](#acpi-settings)
-1. [Xeon Skx Server Firmware Inventory](#xeon-skx-server-firmware-inventory)
-
-## Linux lscpu
-
-```
-$ lscpu
-Architecture: x86_64
-CPU op-mode(s): 32-bit, 64-bit
-Byte Order: Little Endian
-CPU(s): 112
-On-line CPU(s) list: 0-111
-Thread(s) per core: 2
-Core(s) per socket: 28
-Socket(s): 2
-NUMA node(s): 2
-Vendor ID: GenuineIntel
-CPU family: 6
-Model: 85
-Model name: Intel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz
-Stepping: 4
-CPU MHz: 2500.550
-BogoMIPS: 5000.00
-Virtualization: VT-x
-L1d cache: 32K
-L1i cache: 32K
-L2 cache: 1024K
-L3 cache: 39424K
-NUMA node0 CPU(s): 0-27,56-83
-NUMA node1 CPU(s): 28-55,84-111
-Flags: fpu vme de pse tsc msr pae mce cx8 apic sep mtrr pge mca
-cmov pat pse36 clflush dts acpi mmx fxsr sse sse2 ss ht tm pbe syscall nx
-pdpe1gb rdtscp lm constant_tsc art arch_perfmon pebs bts rep_good nopl xtopology
-nonstop_tsc cpuid aperfmperf pni pclmulqdq dtes64 monitor ds_cpl vmx smx est tm2
-ssse3 sdbg fma cx16 xtpr pdcm pcid dca sse4_1 sse4_2 x2apic movbe popcnt
-tsc_deadline_timer aes xsave avx f16c rdrand lahf_lm abm 3dnowprefetch
-cpuid_fault epb cat_l3 cdp_l3 invpcid_single pti ssbd mba ibrs ibpb stibp
-tpr_shadow vnmi flexpriority ept vpid fsgsbase tsc_adjustbmi1 hle avx2 smep bmi2
-erms invpcid rtm cqm mpx rdt_a avx512f avx512dq rdseed adx smap clflushopt clwb
-intel_pt avx512cd avx512bw avx512vl xsaveopt xsavec xgetbv1 xsaves cqm_llc
-cqm_occup_llc cqm_mbm_total cqm_mbm_local dtherm ida arat pln pts pku ospke
-md_clear flush_l1d
-```
-
-### Linux dmidecode
-
-```
- $ dmidecode
- # dmidecode 3.1
- Getting SMBIOS data from sysfs.
- SMBIOS 3.2.1 present.
- Table at 0x6F388000.
-
- Handle 0x0000, DMI type 0, 26 bytes
- BIOS Information
- Vendor: American Megatrends Inc.
- Version: 3.2
- Release Date: 10/18/2019
- Address: 0xF0000
- Runtime Size: 64 kB
- ROM Size: 64 MB
- Characteristics:
- PCI is supported
- BIOS is upgradeable
- BIOS shadowing is allowed
- Boot from CD is supported
- Selectable boot is supported
- BIOS ROM is socketed
- EDD is supported
- 5.25"/1.2 MB floppy services are supported (int 13h)
- 3.5"/720 kB floppy services are supported (int 13h)
- 3.5"/2.88 MB floppy services are supported (int 13h)
- Print screen service is supported (int 5h)
- Serial services are supported (int 14h)
- Printer services are supported (int 17h)
- ACPI is supported
- USB legacy is supported
- BIOS boot specification is supported
- Targeted content distribution is supported
- UEFI is supported
- BIOS Revision: 5.14
-
- Handle 0x0001, DMI type 1, 27 bytes
- System Information
- Manufacturer: Supermicro
- Product Name: SYS-7049GP-TRT
- Version: 0123456789
- Serial Number: S291427X8332242
- UUID: 00000000-0000-0000-0000-AC1F6B8A8DB6
- Wake-up Type: Power Switch
- SKU Number: To be filled by O.E.M.
- Family: To be filled by O.E.M.
-
- Handle 0x0002, DMI type 2, 15 bytes
- Base Board Information
- Manufacturer: Supermicro
- Product Name: X11DPG-QT
- Version: 1.02
- Serial Number: VM183S014930
- Asset Tag: To be filled by O.E.M.
- Features:
- Board is a hosting board
- Board is replaceable
- Location In Chassis: To be filled by O.E.M.
- Chassis Handle: 0x0003
- Type: Motherboard
- Contained Object Handles: 0
-
- Handle 0x0003, DMI type 3, 22 bytes
- Chassis Information
- Manufacturer: Supermicro
- Type: Other
- Lock: Not Present
- Version: 0123456789
- Serial Number: C7470KH06A20167
- Asset Tag: To be filled by O.E.M.
- Boot-up State: Safe
- Power Supply State: Safe
- Thermal State: Safe
- Security Status: None
- OEM Information: 0x00000000
-
- Handle 0x0050, DMI type 4, 48 bytes
- Processor Information
- Socket Designation: CPU1
- Type: Central Processor
- Family: Xeon
- Manufacturer: Intel(R) Corporation
- ID: 54 06 05 00 FF FB EB BF
- Signature: Type 0, Family 6, Model 85, Stepping 4
- Flags:
- FPU (Floating-point unit on-chip)
- VME (Virtual mode extension)
- DE (Debugging extension)
- PSE (Page size extension)
- TSC (Time stamp counter)
- MSR (Model specific registers)
- PAE (Physical address extension)
- MCE (Machine check exception)
- CX8 (CMPXCHG8 instruction supported)
- APIC (On-chip APIC hardware supported)
- SEP (Fast system call)
- MTRR (Memory type range registers)
- PGE (Page global enable)
- MCA (Machine check architecture)
- CMOV (Conditional move instruction supported)
- PAT (Page attribute table)
- PSE-36 (36-bit page size extension)
- CLFSH (CLFLUSH instruction supported)
- DS (Debug store)
- ACPI (ACPI supported)
- MMX (MMX technology supported)
- FXSR (FXSAVE and FXSTOR instructions supported)
- SSE (Streaming SIMD extensions)
- SSE2 (Streaming SIMD extensions 2)
- SS (Self-snoop)
- HTT (Multi-threading)
- TM (Thermal monitor supported)
- PBE (Pending break enabled)
- Version: Intel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz
- Voltage: 1.6 V
- External Clock: 100 MHz
- Max Speed: 4000 MHz
- Current Speed: 2500 MHz
- Status: Populated, Enabled
- Upgrade: Other
- L1 Cache Handle: 0x004D
- L2 Cache Handle: 0x004E
- L3 Cache Handle: 0x004F
- Serial Number: Not Specified
- Asset Tag: UNKNOWN
- Part Number: Not Specified
- Core Count: 28
- Core Enabled: 28
- Thread Count: 56
- Characteristics:
- 64-bit capable
- Multi-Core
- Hardware Thread
- Execute Protection
- Enhanced Virtualization
- Power/Performance Control
-
-
- Handle 0x0054, DMI type 4, 48 bytes
- Processor Information
- Socket Designation: CPU2
- Type: Central Processor
- Family: Xeon
- Manufacturer: Intel(R) Corporation
- ID: 54 06 05 00 FF FB EB BF
- Signature: Type 0, Family 6, Model 85, Stepping 4
- Flags:
- FPU (Floating-point unit on-chip)
- VME (Virtual mode extension)
- DE (Debugging extension)
- PSE (Page size extension)
- TSC (Time stamp counter)
- MSR (Model specific registers)
- PAE (Physical address extension)
- MCE (Machine check exception)
- CX8 (CMPXCHG8 instruction supported)
- APIC (On-chip APIC hardware supported)
- SEP (Fast system call)
- MTRR (Memory type range registers)
- PGE (Page global enable)
- MCA (Machine check architecture)
- CMOV (Conditional move instruction supported)
- PAT (Page attribute table)
- PSE-36 (36-bit page size extension)
- CLFSH (CLFLUSH instruction supported)
- DS (Debug store)
- ACPI (ACPI supported)
- MMX (MMX technology supported)
- FXSR (FXSAVE and FXSTOR instructions supported)
- SSE (Streaming SIMD extensions)
- SSE2 (Streaming SIMD extensions 2)
- SS (Self-snoop)
- HTT (Multi-threading)
- TM (Thermal monitor supported)
- PBE (Pending break enabled)
- Version: Intel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz
- Voltage: 1.6 V
- External Clock: 100 MHz
- Max Speed: 4000 MHz
- Current Speed: 2500 MHz
- Status: Populated, Enabled
- Upgrade: Other
- L1 Cache Handle: 0x0051
- L2 Cache Handle: 0x0052
- L3 Cache Handle: 0x0053
- Serial Number: Not Specified
- Asset Tag: UNKNOWN
- Part Number: Not Specified
- Core Count: 28
- Core Enabled: 28
- Thread Count: 56
- Characteristics:
- 64-bit capable
- Multi-Core
- Hardware Thread
- Execute Protection
- Enhanced Virtualization
- Power/Performance Control
-```
-
-## Xeon Skx Server BIOS Configuration
-
-### Boot Feature
-
-```
- | Quiet Boot [Enabled] |Boot option |
- | | |
- | Option ROM Messages [Force BIOS] | |
- | Bootup NumLock State [On] | |
- | Wait For "F1" If Error [Enabled] | |
- | INT19 Trap Response [Immediate] | |
- | Re-try Boot [Disabled] | |
- | Install Windows 7 USB support [Disabled] | |
- | Port 61h Bit-4 Emulation [Disabled] | |
- | | |
- | Power Configuration | |
- | Watch Dog Function [Disabled] | |
- | Restore on AC Power Loss [Last State] | |
- | Power Button Function [Instant Off] | |
- | Throttle on Power Fail [Disabled] | |
-```
-
-### CPU Configuration
-
-```
- | Processor Configuration |Enables Hyper Threading |
- | -------------------------------------------------- |(Software Method to |
- | Processor BSP Revision 50654 - SKX H0 |Enable/Disable Logical |
- | Processor Socket CPU1 | CPU2 |Processor threads. |
- | Processor ID 00050654* | 000506... | |
- | Processor Frequency 2.500GHz | 2.500GHz | |
- | Processor Max Ratio 19H | 19H | |
- | Processor Min Ratio 0AH | 0AH | |
- | Microcode Revision 02000054 | 02000054 | |
- | L1 Cache RAM 64KB | 64KB | |
- | L2 Cache RAM 1024KB | 1024KB | |
- | L3 Cache RAM 39424KB | 39424KB | |
- | Processor 0 Version | |
- | Intel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz | |
- | Processor 1 Version | |
- | Intel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz | |
- | | |
- | Hyper-Threading [ALL] [Enable] | |
- | Core Enabled 0 | |
- | Monitor/Mwait [Auto] | |
- | Execute Disable Bit [Enable] | |
- | Intel Virtualization Technology [Enable] | |
- | PPIN Control [Unlock/Enable] | |
- | Hardware Prefetcher [Enable] | |
- | Adjacent Cache Prefetch [Enable] | |
- | DCU Streamer Prefetcher [Enable] | |
- | DCU IP Prefetcher [Enable] | |
- | LLC Prefetch [Disable] | |
- | Extended APIC [Disable] | |
- | AES-NI [Enable] | |
- |> Advanced Power Management Configuration | |
-```
-
-#### Advanced Power Management Configuration
-
-```
- | Advanced Power Management Configuration |Switch CPU Power Management |
- | -------------------------------------------------- |profile |
- | Power Technology [Custom] | |
- | Power Performance Tuning [BIOS Controls EPB] | |
- | ENERGY_PERF_BIAS_CFG mode [Maximum Performance] | |
- |> CPU P State Control | |
- |> Hardware PM State Control | |
- |> CPU C State Control | |
- |> Package C State Control | |
- |> CPU T State Control | |
-```
-
-##### CPU P State Control
-
-```
- | CPU P State Control |Enable/Disable EIST |
- | |(P-States) |
- | SpeedStep (Pstates) [Disable] | |
- | EIST PSD Function [HW_ALL] | |
-```
-
-##### Hardware PM State Control
-
-```
- | Hardware PM State Control |Disable: Hardware chooses a |
- | |P-state based on OS Request |
- | Hardware P-States [Disable] |(Legacy P-States) |
- | |Native Mode:Hardware |
- | |chooses a P-state based on |
- | |OS guidance |
- | |Out of Band Mode:Hardware |
- | |autonomously chooses a |
- | |P-state (no OS guidance) |
-```
-
-##### CPU C State Control
-
-```
- | CPU C State Control |Autonomous Core C-State |
- | |Control |
- | Autonomous Core C-State [Disable] | |
- | CPU C6 report [Disable] | |
- | Enhanced Halt State (C1E) [Disable] | |
-```
-
-##### Package C State Control
-
-```
- | Package C State Control |Package C State limit |
- | | |
- | Package C State [C0/C1 state] | |
-```
-
-##### CPU T State Control
-
-```
- | CPU T State Control |Enable/Disable Software |
- | |Controlled T-States |
- | Software Controlled T-States [Disable] | |
-```
-
-#### Chipset Configuration
-
-```
- | WARNING: Setting wrong values in below sections may cause |North Bridge Parameters |
- | system to malfunction. | |
- |> North Bridge | |
- |> South Bridge | |
-```
-
-##### North Bridge
-
-```
- |> UPI Configuration |Displays and provides |
- |> Memory Configuration |option to change the UPI |
- |> IIO Configuration |Settings |
-```
-
-##### UPI Configuration
-
-```
- | UPI Configuration |Choose Topology Precedence |
- | -------------------------------------------------- |to degrade features if |
- | Number of CPU 2 |system options are in |
- | Number of Active UPI Link 3 |conflict or choose Feature |
- | Current UPI Link Speed Fast |Precedence to degrade |
- | Current UPI Link Frequency 10.4 GT/s |topology if system options |
- | UPI Global MMIO Low Base / Limit 90000000 / FBFFFFFF |are in conflict. |
- | UPI Global MMIO High Base / Limit 0000000000000000 / ... | |
- | UPI Pci-e Configuration Base / Size 80000000 / 10000000 | |
- | Degrade Precedence [Topology Precedence] | |
- | Link L0p Enable [Disable] | |
- | Link L1 Enable [Disable] | |
- | IO Directory Cache (IODC) [Auto] | |
- | SNC [Disable] | |
- | XPT Prefetch [Disable] | |
- | KTI Prefetch [Enable] | |
- | Local/Remote Threshold [Auto] | |
- | Stale AtoS [Disable] | |
- | LLC dead line alloc [Enable] | |
- | Isoc Mode [Auto] | |
-```
-
-##### Memory Configuration
-
-```
- | |POR - Enforces Plan Of |
- | -------------------------------------------------- |Record restrictions for |
- | Integrated Memory Controller (iMC) |DDR4 frequency and voltage |
- | -------------------------------------------------- |programming. Disable - |
- | |Disables this feature. |
- | Enforce POR [POR] | |
- | PPR Type [Hard PPR] | |
- | Enhanced PPR [Disable] | |
- | Operation Mode [Test and Repair] | |
- | Memory Frequency [2933] | |
- | Data Scrambling for DDR4 [Auto] | |
- | tCCD_L Relaxation [Auto] | |
- | tRWSR Relaxation [Disable] | |
- | tRFC Optimization for 16Gb Based DIMM [Force 550ns] | |
- | 2x Refresh [Auto] | |
- | Page Policy [Auto] | |
- | IMC Interleaving [2-way Interleave] | |
- |> Memory Topology | |
- |> Memory RAS Configuration | |
-```
-
-##### IIO Configuration
-
-```
- | IIO Configuration |Expose IIO DFX devices and |
- | -------------------------------------------------- |other CPU devices like PMON |
- | | |
- | EV DFX Features [Disable] | |
- |> CPU1 Configuration | |
- |> CPU2 Configuration | |
- |> IOAT Configuration | |
- |> Intel. VT for Directed I/O (VT-d) | |
- |> Intel. VMD technology | |
- | | |
- | IIO-PCIE Express Global Options | |
- | ======================================== | |
- | PCI-E Completion Timeout Disable [No] | |
-```
-
-##### CPU1 Configuration
-
-```
- | IOU0 (IIO PCIe Br1) [Auto] |Selects PCIe port |
- | IOU1 (IIO PCIe Br2) [Auto] |Bifurcation for selected |
- | IOU2 (IIO PCIe Br3) [Auto] |slot(s) |
- |> CPU1 SLOT2 PCI-E 3.0 X16 | |
- |> CPU1 SLOT4 PCI-E 3.0 X16 | |
- |> CPU1 SLOT9 PCI-E 3.0 X16 | |
-```
-
-##### CPU2 Configuration
-
-```
- | IOU0 (IIO PCIe Br1) [Auto] |Selects PCIe port |
- | IOU1 (IIO PCIe Br2) [Auto] |Bifurcation for selected |
- | IOU2 (IIO PCIe Br3) [Auto] |slot(s) |
- |> CPU2 SLOT6 PCI-E 3.0 X16 | |
- |> CPU2 SLOT8 PCI-E 3.0 X16 | |
- |> CPU2 SLOT10 PCI-E 3.0 X16 | |
-```
-
-#### South Bridge
-
-```
- | |Enables Legacy USB support. |
- | USB Module Version 21 |AUTO option disables legacy |
- | |support if no USB devices |
- | USB Devices: |are connected. DISABLE |
- | 1 Keyboard, 1 Mouse, 1 Hub |option will keep USB |
- | |devices available only for |
- | Legacy USB Support [Enabled] |EFI applications. |
- | XHCI Hand-off [Enabled] | |
- | Port 60/64 Emulation [Enabled] | |
- | PCIe PLL SSC [Disable] | |
- | Real USB Wake Up [Enabled] | |
- | Front USB Wake Up [Enabled] | |
- | | |
- | Azalia [Auto] | |
- | Azalia PME Enable [Disabled] | |
-```
-
-### PCIe/PCI/PnP Configuration
-
-```
- | PCI Bus Driver Version A5.01.18 |Enables or Disables 64bit |
- | |capable Devices to be |
- | PCI Devices Common Settings: |Decoded in Above 4G Address |
- | Above 4G Decoding [Enabled] |Space (Only if System |
- | SR-IOV Support [Enabled] |Supports 64 bit PCI |
- | ARI Support [Enabled] |Decoding). |
- | MMIO High Base [56T] | |
- | MMIO High Granularity Size [256G] | |
- | Maximum Read Request [Auto] | |
- | MMCFG Base [2G] | |
- | NVMe Firmware Source [Vendor Defined Fi...] | |
- | VGA Priority [Onboard] | |
- | CPU1 SLOT2 PCI-E 3.0 X16 OPROM [Legacy] | |
- | CPU1 SLOT4 PCI-E 3.0 X16 OPROM [Legacy] | |
- | CPU2 SLOT6 PCI-E 3.0 X16 OPROM [Legacy] | |
- | CPU2 SLOT8 PCI-E 3.0 X16 OPROM [Legacy] | |
- | CPU1 SLOT9 PCI-E 3.0 X16 OPROM [Legacy] | |
- | CPU2 SLOT10 PCI-E 3.0 X16 OPROM [Legacy] | |
- | CPU2 SLOT11 PCI-E 3.0 X4(IN X8) OPROM [Legacy] | |
- | M.2 CONNECTOR OPROM [Legacy] | |
- | Onboard LAN1 Option ROM [Legacy] | |
- | Onboard LAN2 Option ROM [Disabled] | |
- | Onboard Video Option ROM [Legacy] | |
- |> Network Stack Configuration | |
-```
-
-### ACPI Settings
-
-```
- | ACPI Settings |Enable or Disable Non |
- | |uniform Memory Access |
- | NUMA [Enabled] |(NUMA). |
- | WHEA Support [Enabled] | |
- | High Precision Event Timer [Enabled] | |
-```
-
-## Xeon Skx Server Firmware Inventory
-
-```
-Host. IPMI IP. BMC. BIOS. CPLD. Aptio SU. CPU Microcode. PCI Bus. ME Operation FW. X710 Firmware. XXV710 Firmware. i40e.
-s1-t11-sut1. 10.30.50.47. 1.39. 2.1. 03.B1.03. 2.19.1268. 0200005e. A5.01.12. 4.0.4.294. 6.01 0x800034af 1.1747.0. N/A. 2.1.14-k.
-s2-t12-sut1. 10.30.50.48. 1.39. 2.0b. 03.B1.03. 2.19.1268. 0200005e. A5.01.12. 4.0.4.294. 6.01 0x800034af 1.1747.0. N/A. 2.1.14-k.
-s3-t21-sut1. 10.30.50.41. 1.39. 3.2. 03.B1.03. 2.19.1268. 02000065. A5.01.18. 4.0.4.294. 6.01 0x800034af 1.1747.0. 6.02 0x80003620 1.1747.0. 2.1.14-k.
-s4-t21-tg1. 10.30.50.42. 1.39. 3.2. 03.B1.03. 2.19.1268. 02000065. A5.01.18. 4.0.4.294. 6.01 0x800034af 1.1747.0. 6.02 0x80003620 1.1747.0. 2.4.10.
-s5-t22-sut1. 10.30.50.49. 1.53. 3.2. 03.B1.03. 2.19.1268. 02000065. A5.01.18. 4.0.4.294. 6.01 0x800034af 1.1747.0. 6.02 0x80003620 1.1747.0. 2.1.14-k.
-s6-t22-tg1. 10.30.50.50. 1.53. 3.2. 03.B1.03. 2.19.1268. 02000065. A5.01.18. 4.0.4.294. 6.01 0x800034af 1.1747.0. 6.02 0x80003620 1.1747.0. 2.4.10.
-s7-t23-sut1. 10.30.50.51. 1.53. 3.2. 03.B1.03. 2.19.1268. 02000065. A5.01.18. 4.0.4.294. 6.01 0x800034af 1.1747.0. 6.02 0x80003620 1.1747.0. 2.1.14-k.
-s8-t23-tg1. 10.30.50.52. 1.39. 3.2. 03.B1.03. 2.19.1268. 02000065. A5.01.18. 4.0.4.294. 6.01 0x800034af 1.1747.0. 6.02 0x80003620 1.1747.0. 2.4.10.
-s9-t24-sut1. 10.30.50.53. 1.39. 3.2. 03.B1.03. 2.19.1268. 02000065. A5.01.18. 4.0.4.294. 6.01 0x800034af 1.1747.0. 6.02 0x80003620 1.1747.0. 2.1.14-k.
-s10-t24-tg1. 10.30.50.54. 1.39. 3.2. 03.B1.03. 2.19.1268. 02000065. A5.01.18. 4.0.4.294. 6.01 0x800034af 1.1747.0. 6.02 0x80003620 1.1747.0. 2.4.10
-s11-t31-sut1. 10.30.50.43. 1.39. 3.2. 03.B1.03. 2.19.1268. 02000065. A5.01.18. 4.0.4.294. 6.01 0x800034af 1.1747.0. 6.02 0x80003620 1.1747.0. 2.1.14-k.
-s12-t31-sut2. 10.30.50.44. 1.39. 3.2. 03.B1.03. 2.19.1268. 02000065. A5.01.18. 4.0.4.294. 6.01 0x800034af 1.1747.0. 6.02 0x80003620 1.1747.0. 2.1.14-k.
-s13-t31-tg1. 10.30.50.45. 1.39. 3.2. 03.B1.03. 2.19.1268. 02000065. A5.01.18. 4.0.4.294. 6.01 0x800034af 1.1747.0. 6.02 0x80003620 1.1747.0. 2.4.10.
-s14-t32-sut1. 10.30.50.55. 1.39. 3.2. 03.B1.03. 2.19.1268. 02000065. A5.01.18. 4.0.4.294. 6.01 0x800034af 1.1747.0. 6.02 0x80003620 1.1747.0. 2.1.14-k.
-s15-t32-sut2. 10.30.50.56. 1.39. 3.2. 03.B1.03. 2.19.1268. 02000065. A5.01.18. 4.0.4.294. 6.01 0x800034af 1.1747.0. 6.02 0x80003620 1.1747.0. 2.1.14-k.
-s16-t32-tg1. 10.30.50.57. 1.39. 3.2. 03.B1.03. 2.19.1268. 02000065. A5.01.18. 4.0.4.294. 6.01 0x800034af 1.1747.0. 6.02 0x80003620 1.1747.0. 2.4.10.
-s19-t33t34-tg1. 10.30.50.46. 1.39. 3.2. 03.B1.03. 2.19.1268. 02000065. A5.01.18. 4.0.4.294. 6.01 0x800034af 1.1747.0. 6.02 0x80003620 1.1747.0. 2.4.10.
-```
diff --git a/docs/lab/testbeds_sm_zn2_hw_bios_cfg.md b/docs/lab/testbeds_sm_zn2_hw_bios_cfg.md
deleted file mode 100644
index 6e274da971..0000000000
--- a/docs/lab/testbeds_sm_zn2_hw_bios_cfg.md
+++ /dev/null
@@ -1,634 +0,0 @@
-# SuperMicro Cascadelake Servers - HW and BIOS Configuration
-
-1. [Linux lscpu](#linux-lscpu)
-1. [Linux dmidecode](#dmidecode)
-1. [Linux dmidecode pci](#linux-dmidecode-pci)
-1. [Linux dmidecode memory](#linux-dmidecode-memory)
-1. [EPYC zn2 Server BIOS Configuration](#epyc-zn2-server-bios-configuration)
- 1. [Boot Feature](#boot-feature)
- 1. [CPU Configuration](#cpu-configuration)
- 1. [Advanced Power Management Configuration](#advanced-power-management-configuration)
- 1. [CPU P State Control](#cpu-p-state-control)
- 1. [Hardware PM State Control](#hardware-pm-state-control)
- 1. [CPU C State Control](#cpu-c-state-control)
- 1. [Package C State Control](#package-c-state-control)
- 1. [CPU T State Control](#cpu-t-state-control)
- 1. [Chipset Configuration](#chipset-configuration)
- 1. [North Bridge](#north-bridge)
- 1. [UPI Configuration](#upi-configuration)
- 1. [Memory Configuration](#memory-configuration)
- 1. [IIO Configuration](#iio-configuration)
- 1. [CPU1 Configuration](#cpu1-configuration)
- 1. [CPU2 Configuration](#cpu2-configuration)
- 1. [South Bridge](#south-bridge)
- 1. [PCIe/PCI/PnP Configuration](#pciepcipnp-configuration)
- 1. [ACPI Settings](#acpi-settings)
-1. [EPYC zn2 Server Firmware Inventory](#epyc-zn2-server-firmware-inventory)
-
-## Linux lscpu
-
-```
-$ lscpu
-Architecture: x86_64
-CPU op-mode(s): 32-bit, 64-bit
-Byte Order: Little Endian
-CPU(s): 64
-On-line CPU(s) list: 0-63
-Thread(s) per core: 2
-Core(s) per socket: 32
-Socket(s): 1
-NUMA node(s): 2
-Vendor ID: AuthenticAMD
-CPU family: 23
-Model: 49
-Model name: AMD EPYC 7532 32-Core Processor
-Stepping: 0
-CPU MHz: 1981.470
-CPU max MHz: 2400.0000
-CPU min MHz: 1500.0000
-BogoMIPS: 4800.05
-Virtualization: AMD-V
-L1d cache: 32K
-L1i cache: 32K
-L2 cache: 512K
-L3 cache: 16384K
-NUMA node0 CPU(s): 0-15,32-47
-NUMA node1 CPU(s): 16-31,48-63
-Flags: fpu vme de pse tsc msr pae mce cx8 apic sep mtrr pge mca cmov pat pse36 clflush mmx fxsr sse sse2 ht syscall nx mmxext fxsr_opt pdpe1gb rdtscp lm constant_tsc rep_good nopl xtopology nonstop_tsc cpuid extd_apicid aperfmperf pni pclmulqdq monitor ssse3 fma cx16 sse4_1 sse4_2 x2apic movbe popcnt aes xsave avx f16c rdrand lahf_lm cmp_legacy svm extapic cr8_legacy abm sse4a misalignsse 3dnowprefetch osvw ibs skinit wdt tce topoext perfctr_core perfctr_nb bpext perfctr_llc mwaitx cpb cat_l3 cdp_l3 hw_pstate sme ssbd ibrs ibpb stibp vmmcall fsgsbase bmi1 avx2 smep bmi2 cqm rdt_a rdseed adx smap clflushopt clwb sha_ni xsaveopt xsavec xgetbv1 xsaves cqm_llc cqm_occup_llc cqm_mbm_total cqm_mbm_local clzero irperf xsaveerptr arat npt lbrv svm_lock nrip_save tsc_scale vmcb_clean flushbyasid decodeassists pausefilter pfthreshold avic v_vmsave_vmload vgif umip rdpid overflow_recov succor smca
-```
-
-```
-$ lscpu
-Architecture: x86_64
-CPU op-mode(s): 32-bit, 64-bit
-Byte Order: Little Endian
-CPU(s): 64
-On-line CPU(s) list: 0-63
-Thread(s) per core: 2
-Core(s) per socket: 32
-Socket(s): 1
-NUMA node(s): 2
-Vendor ID: AuthenticAMD
-CPU family: 23
-Model: 49
-Model name: AMD EPYC 7532 32-Core Processor
-Stepping: 0
-CPU MHz: 1981.470
-CPU max MHz: 2400.0000
-CPU min MHz: 1500.0000
-BogoMIPS: 4800.05
-Virtualization: AMD-V
-L1d cache: 32K
-L1i cache: 32K
-L2 cache: 512K
-L3 cache: 16384K
-NUMA node0 CPU(s): 0-15,32-47
-NUMA node1 CPU(s): 16-31,48-63
-Flags: fpu vme de pse tsc msr pae mce cx8 apic sep mtrr pge mca cmov pat pse36 clflush mmx fxsr sse sse2 ht syscall nx mmxext fxsr_opt pdpe1gb rdtscp lm constant_tsc rep_good nopl xtopology nonstop_tsc cpuid extd_apicid aperfmperf pni pclmulqdq monitor ssse3 fma cx16 sse4_1 sse4_2 x2apic movbe popcnt aes xsave avx f16c rdrand lahf_lm cmp_legacy svm extapic cr8_legacy abm sse4a misalignsse 3dnowprefetch osvw ibs skinit wdt tce topoext perfctr_core perfctr_nb bpext perfctr_llc mwaitx cpb cat_l3 cdp_l3 hw_pstate sme ssbd ibrs ibpb stibp vmmcall fsgsbase bmi1 avx2 smep bmi2 cqm rdt_a rdseed adx smap clflushopt clwb sha_ni xsaveopt xsavec xgetbv1 xsaves cqm_llc cqm_occup_llc cqm_mbm_total cqm_mbm_local clzero irperf xsaveerptr arat npt lbrv svm_lock nrip_save tsc_scale vmcb_clean flushbyasid decodeassists pausefilter pfthreshold avic v_vmsave_vmload vgif umip rdpid overflow_recov succor smca
-```
-
-## Linux dmidecode
-
-```
- $ dmidecode -t slot
- Handle 0x0026, DMI type 7, 27 bytes
- Cache Information
- Socket Designation: L1 Cache
- Configuration: Enabled, Not Socketed, Level 1
- Operational Mode: Write Back
- Location: Internal
- Installed Size: 2048 kB
- Maximum Size: 2048 kB
- Supported SRAM Types:
- Pipeline Burst
- Installed SRAM Type: Pipeline Burst
- Speed: 1 ns
- Error Correction Type: Multi-bit ECC
- System Type: Unified
- Associativity: 8-way Set-associative
-
- Handle 0x0027, DMI type 7, 27 bytes
- Cache Information
- Socket Designation: L2 Cache
- Configuration: Enabled, Not Socketed, Level 2
- Operational Mode: Write Back
- Location: Internal
- Installed Size: 16384 kB
- Maximum Size: 16384 kB
- Supported SRAM Types:
- Pipeline Burst
- Installed SRAM Type: Pipeline Burst
- Speed: 1 ns
- Error Correction Type: Multi-bit ECC
- System Type: Unified
- Associativity: 8-way Set-associative
-
- Handle 0x0028, DMI type 7, 27 bytes
- Cache Information
- Socket Designation: L3 Cache
- Configuration: Enabled, Not Socketed, Level 3
- Operational Mode: Write Back
- Location: Internal
- Installed Size: 262144 kB
- Maximum Size: 262144 kB
- Supported SRAM Types:
- Pipeline Burst
- Installed SRAM Type: Pipeline Burst
- Speed: 1 ns
- Error Correction Type: Multi-bit ECC
- System Type: Unified
- Associativity: 16-way Set-associative
-
- Handle 0x0029, DMI type 4, 48 bytes
- Processor Information
- Socket Designation: CPU
- Type: Central Processor
- Family: Zen
- Manufacturer: Advanced Micro Devices, Inc.
- ID: 10 0F 83 00 FF FB 8B 17
- Signature: Family 23, Model 49, Stepping 0
- Flags:
- FPU (Floating-point unit on-chip)
- VME (Virtual mode extension)
- DE (Debugging extension)
- PSE (Page size extension)
- TSC (Time stamp counter)
- MSR (Model specific registers)
- PAE (Physical address extension)
- MCE (Machine check exception)
- CX8 (CMPXCHG8 instruction supported)
- APIC (On-chip APIC hardware supported)
- SEP (Fast system call)
- MTRR (Memory type range registers)
- PGE (Page global enable)
- MCA (Machine check architecture)
- CMOV (Conditional move instruction supported)
- PAT (Page attribute table)
- PSE-36 (36-bit page size extension)
- CLFSH (CLFLUSH instruction supported)
- MMX (MMX technology supported)
- FXSR (FXSAVE and FXSTOR instructions supported)
- SSE (Streaming SIMD extensions)
- SSE2 (Streaming SIMD extensions 2)
- HTT (Multi-threading)
- Version: AMD EPYC 7532 32-Core Processor
- Voltage: 1.1 V
- External Clock: 100 MHz
- Max Speed: 3300 MHz
- Current Speed: 2400 MHz
- Status: Populated, Enabled
- Upgrade: Socket SP3
- L1 Cache Handle: 0x0026
- L2 Cache Handle: 0x0027
- L3 Cache Handle: 0x0028
- Serial Number: Unknown
- Asset Tag: Unknown
- Part Number: Unknown
- Core Count: 32
- Core Enabled: 32
- Thread Count: 64
- Characteristics:
- 64-bit capable
- Multi-Core
- Hardware Thread
- Execute Protection
- Enhanced Virtualization
- Power/Performance Control
-```
-
-## Linux dmidecode pci
-
-```
- $ dmidecode -t slot
- Getting SMBIOS data from sysfs.
- SMBIOS 3.2.0 present.
- # SMBIOS implementations newer than version 3.1.1 are not
- # fully supported by this version of dmidecode.
-
- Handle 0x000A, DMI type 9, 17 bytes
- System Slot Information
- Designation: M.2-HC1 CPU PCI-E 4.0 X4/X2
- Type: x4 PCI Express 3 x4
- Current Usage: Available
- Length: Short
- ID: 1
- Characteristics:
- 3.3 V is provided
- Opening is shared
- PME signal is supported
- Bus Address: 0000:ff:00.0
-
- Handle 0x000B, DMI type 9, 17 bytes
- System Slot Information
- Designation: M.2-HC2 CPU PCI-E 4.0 X2
- Type: x2 PCI Express 3 x2
- Current Usage: Available
- Length: Short
- ID: 2
- Characteristics:
- 3.3 V is provided
- Opening is shared
- PME signal is supported
- Bus Address: 0000:ff:00.0
-
- Handle 0x0042, DMI type 9, 17 bytes
- System Slot Information
- Designation: RSC-W-66G4 SLOT1 PCI-E 4.0 X16
- Type: x16 PCI Express 3 x16
- Current Usage: In Use
- Length: Long
- ID: 1
- Characteristics:
- 3.3 V is provided
- PME signal is supported
- Bus Address: 0000:41:00.0
-
- Handle 0x0043, DMI type 9, 17 bytes
- System Slot Information
- Designation: RSC-W-66G4 SLOT2 PCI-E 4.0 X16
- Type: x16 PCI Express 3 x16
- Current Usage: In Use
- Length: Long
- ID: 2
- Characteristics:
- 3.3 V is provided
- PME signal is supported
- Bus Address: 0000:81:00.0
-
- Handle 0x0045, DMI type 9, 17 bytes
- System Slot Information
- Designation: RSC-WR-6 SLOT1 PCI-E 4.0 X16
- Type: x16 PCI Express 3 x16
- Current Usage: In Use
- Length: Long
- ID: 1
- Characteristics:
- 3.3 V is provided
- PME signal is supported
- Bus Address: 0000:01:00.0
-
-```
-
-## Linux dmidecode memory
-
-```
- $ dmidecode -t memory
- # dmidecode 3.1
- Getting SMBIOS data from sysfs.
- SMBIOS 3.2.0 present.
- # SMBIOS implementations newer than version 3.1.1 are not
- # fully supported by this version of dmidecode.
-
- Handle 0x0023, DMI type 16, 23 bytes
- Physical Memory Array
- Location: System Board Or Motherboard
- Use: System Memory
- Error Correction Type: Multi-bit ECC
- Maximum Capacity: 2 TB
- Error Information Handle: 0x0022
- Number Of Devices: 8
-
- Handle 0x002B, DMI type 17, 84 bytes
- Memory Device
- Array Handle: 0x0023
- Error Information Handle: 0x002A
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMMA1
- Bank Locator: P0_Node0_Channel0_Dimm0
- Type: DDR4
- Type Detail: Synchronous Registered (Buffered)
- Speed: 3200 MT/s
- Manufacturer: SK Hynix
- Serial Number: 431E9216
- Asset Tag: P1-DIMMA1_AssetTag (date:19/00)
- Part Number: HMA84GR7CJR4N-XN
- Rank: 2
- Configured Clock Speed: 3200 MT/s
- Minimum Voltage: 1.2 V
- Maximum Voltage: 1.2 V
- Configured Voltage: 1.2 V
-
- Handle 0x002E, DMI type 17, 84 bytes
- Memory Device
- Array Handle: 0x0023
- Error Information Handle: 0x002D
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMMB1
- Bank Locator: P0_Node0_Channel1_Dimm0
- Type: DDR4
- Type Detail: Synchronous Registered (Buffered)
- Speed: 3200 MT/s
- Manufacturer: SK Hynix
- Serial Number: 431E91D2
- Asset Tag: P1-DIMMB1_AssetTag (date:19/00)
- Part Number: HMA84GR7CJR4N-XN
- Rank: 2
- Configured Clock Speed: 3200 MT/s
- Minimum Voltage: 1.2 V
- Maximum Voltage: 1.2 V
- Configured Voltage: 1.2 V
-
- Handle 0x0031, DMI type 17, 84 bytes
- Memory Device
- Array Handle: 0x0023
- Error Information Handle: 0x0030
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMMC1
- Bank Locator: P0_Node0_Channel2_Dimm0
- Type: DDR4
- Type Detail: Synchronous Registered (Buffered)
- Speed: 3200 MT/s
- Manufacturer: SK Hynix
- Serial Number: 431E918A
- Asset Tag: P1-DIMMC1_AssetTag (date:19/00)
- Part Number: HMA84GR7CJR4N-XN
- Rank: 2
- Configured Clock Speed: 3200 MT/s
- Minimum Voltage: 1.2 V
- Maximum Voltage: 1.2 V
- Configured Voltage: 1.2 V
-
- Handle 0x0034, DMI type 17, 84 bytes
- Memory Device
- Array Handle: 0x0023
- Error Information Handle: 0x0033
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMMD1
- Bank Locator: P0_Node0_Channel3_Dimm0
- Type: DDR4
- Type Detail: Synchronous Registered (Buffered)
- Speed: 3200 MT/s
- Manufacturer: SK Hynix
- Serial Number: 431E9187
- Asset Tag: P1-DIMMD1_AssetTag (date:19/00)
- Part Number: HMA84GR7CJR4N-XN
- Rank: 2
- Configured Clock Speed: 3200 MT/s
- Minimum Voltage: 1.2 V
- Maximum Voltage: 1.2 V
- Configured Voltage: 1.2 V
-
- Handle 0x0037, DMI type 17, 84 bytes
- Memory Device
- Array Handle: 0x0023
- Error Information Handle: 0x0036
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMME1
- Bank Locator: P0_Node0_Channel4_Dimm0
- Type: DDR4
- Type Detail: Synchronous Registered (Buffered)
- Speed: 3200 MT/s
- Manufacturer: SK Hynix
- Serial Number: 431E9178
- Asset Tag: P1-DIMME1_AssetTag (date:19/00)
- Part Number: HMA84GR7CJR4N-XN
- Rank: 2
- Configured Clock Speed: 3200 MT/s
- Minimum Voltage: 1.2 V
- Maximum Voltage: 1.2 V
- Configured Voltage: 1.2 V
-
- Handle 0x003A, DMI type 17, 84 bytes
- Memory Device
- Array Handle: 0x0023
- Error Information Handle: 0x0039
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMMF1
- Bank Locator: P0_Node0_Channel5_Dimm0
- Type: DDR4
- Type Detail: Synchronous Registered (Buffered)
- Speed: 3200 MT/s
- Manufacturer: SK Hynix
- Serial Number: 431E9206
- Asset Tag: P1-DIMMF1_AssetTag (date:19/00)
- Part Number: HMA84GR7CJR4N-XN
- Rank: 2
- Configured Clock Speed: 3200 MT/s
- Minimum Voltage: 1.2 V
- Maximum Voltage: 1.2 V
- Configured Voltage: 1.2 V
-
- Handle 0x003D, DMI type 17, 84 bytes
- Memory Device
- Array Handle: 0x0023
- Error Information Handle: 0x003C
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMMG1
- Bank Locator: P0_Node0_Channel6_Dimm0
- Type: DDR4
- Type Detail: Synchronous Registered (Buffered)
- Speed: 3200 MT/s
- Manufacturer: SK Hynix
- Serial Number: 431E9207
- Asset Tag: P1-DIMMG1_AssetTag (date:19/00)
- Part Number: HMA84GR7CJR4N-XN
- Rank: 2
- Configured Clock Speed: 3200 MT/s
- Minimum Voltage: 1.2 V
- Maximum Voltage: 1.2 V
- Configured Voltage: 1.2 V
-
- Handle 0x0040, DMI type 17, 84 bytes
- Memory Device
- Array Handle: 0x0023
- Error Information Handle: 0x003F
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMMH1
- Bank Locator: P0_Node0_Channel7_Dimm0
- Type: DDR4
- Type Detail: Synchronous Registered (Buffered)
- Speed: 3200 MT/s
- Manufacturer: SK Hynix
- Serial Number: 431E9209
- Asset Tag: P1-DIMMH1_AssetTag (date:19/00)
- Part Number: HMA84GR7CJR4N-XN
- Rank: 2
- Configured Clock Speed: 3200 MT/s
- Minimum Voltage: 1.2 V
- Maximum Voltage: 1.2 V
- Configured Voltage: 1.2 V
-```
-
-## EPYC zn2 Server BIOS Configuration - TG
-
-### Boot Feature
-
-```
- | Quiet Boot [Enabled] |Boot option |
- | | |
- | Option ROM Messages [Force BIOS] | |
- | Bootup NumLock State [On] | |
- | Wait For "F1" If Error [Enabled] | |
- | INT19 Trap Response [Immediate] | |
- | Re-try Boot [Disabled] | |
- | | |
- | Power Configuration | |
- | Watch Dog Function [Disabled] | |
- | Restore on AC Power Loss [Last State] | |
- | Power Button Function [Instant Off] | |
-```
-
-### CPU Configuration
-
-```
- | ACPI Settings ^| |
- | -------------------------------------------------- *| |
- | PCI AER Support [Disabled] *| |
- | High Precision Event Timer [Disabled] *| |
- | NUMA Nodes Per Socket [NPS2] *| |
- | ACPI SRAT L3 Cache As NUMA Domain [Auto] *| |
- | *| |
- | CPU Configuration ^| |
- | -------------------------------------------------- *| |
- | SMT Control [Auto] *| |
- | Core Performance Boost [Auto] *| |
- | Global C-state control [Disabled] *| |
- | Local APIC Mode [Auto] *| |
- | CCD Control [Auto] *| |
- | Core Control [Auto] *| |
- | Core Control [Auto] *| |
- | L1 Stream HW Prefetcher [Enabled] *| |
- | L2 Stream HW Prefetcher [Enabled] *| |
- | SVM Mode [Enabled] *| |
- | SMEE [Disabled] *| |
- | *| |
- |> CPU1 Information *| |
- | *| |
- | NB Configuration ^| |
- | -------------------------------------------------- *| |
- | Determinism Control [Manual] *| |
- | Determinism Slider [Performance] *| |
- | cTDP Control [Disabled] *| |
- | IOMMU [Disabled] *| |
- | ACS Enable [Auto] *| |
- | Package Power Limit Control [Auto] *| |
- | APBDIS [1] *| |
- | Fixed SOC Pstate [P0] *| |
- | DF Cstates [Enabled] *| |
- | Preferred IO [Manual] *| |
- | Preferred IO Bus [##] *| |
- | *| |
- | *|-----------------------------|
- | *|><: Select Screen |
- | *|^v: Select Item |
- | *|Enter: Select |
- | +|+/-: Change Opt. |
- | +|F1: General Help |
- | +|F2: Previous Values |
- | +|F3: Optimized Defaults |
- | v|F4: Save & Exit |
- | | |
-```
-
-
-## EPYC zn2 Server BIOS Configuration - DUT
-
-### Boot Feature
-
-```
- | Quiet Boot [Enabled] |Boot option |
- | | |
- | Option ROM Messages [Force BIOS] | |
- | Bootup NumLock State [On] | |
- | Wait For "F1" If Error [Enabled] | |
- | INT19 Trap Response [Immediate] | |
- | Re-try Boot [Disabled] | |
- | | |
- | Power Configuration | |
- | Watch Dog Function [Disabled] | |
- | Restore on AC Power Loss [Last State] | |
- | Power Button Function [Instant Off] | |
-```
-
-### CPU Configuration
-
-```
- | ACPI Settings ^| |
- | -------------------------------------------------- *| |
- | PCI AER Support [Disabled] *| |
- | High Precision Event Timer [Disabled] *| |
- | NUMA Nodes Per Socket [NPS2] *| |
- | ACPI SRAT L3 Cache As NUMA Domain [Auto] *| |
- | *| |
- | CPU Configuration ^| |
- | -------------------------------------------------- *| |
- | SMT Control [Auto] *| |
- | Core Performance Boost [Auto] *| |
- | Global C-state control [Disabled] *| |
- | Local APIC Mode [Auto] *| |
- | CCD Control [Auto] *| |
- | Core Control [Auto] *| |
- | Core Control [Auto] *| |
- | L1 Stream HW Prefetcher [Enabled] *| |
- | L2 Stream HW Prefetcher [Enabled] *| |
- | SVM Mode [Enabled] *| |
- | SMEE [Disabled] *| |
- | *| |
- |> CPU1 Information *| |
- | *| |
- | NB Configuration ^| |
- | -------------------------------------------------- *| |
- | Determinism Control [Manual] *| |
- | Determinism Slider [Performance] *| |
- | cTDP Control [Disabled] *| |
- | IOMMU [Disabled] *| |
- | ACS Enable [Auto] *| |
- | Package Power Limit Control [Auto] *| |
- | APBDIS [1] *| |
- | Fixed SOC Pstate [P0] *| |
- | DF Cstates [Enabled] *| |
- | Preferred IO [Manual] *| |
- | Preferred IO Bus [##] *| |
- | *| |
- | *|-----------------------------|
- | *|><: Select Screen |
- | *|^v: Select Item |
- | *|Enter: Select |
- | +|+/-: Change Opt. |
- | +|F1: General Help |
- | +|F2: Previous Values |
- | +|F3: Optimized Defaults |
- | v|F4: Save & Exit |
- | | |
-```
-
-
-## EPYC zn2 Server Firmware Inventory
-
-```
-Host. IPMI IP. BMC. BIOS. CPLD. CPU Microcode. PCI Bus. X710 Firmware. XXV710 Firmware. i40e. MLX5 Firmware. mlx5_core
-s60-t210-sut1. 10.30.55.24. 03.10.04. 1.1a. 02.c2.00. 0x8301038. ?. 6.80 0x80003ce6 1.2074.0. 6.01 0x80003554 1.1747.0. 2.1.14-k. 16.26.1040. 4.6-1.0.1.
-s61-t210-tg1. 10.30.55.25. 03.10.04. 1.1a. 02.c2.00. 0x8301038. ?. 6.80 0x80003ce6 1.2074.0. 6.01 0x80003554 1.1747.0. 2.1.14-k. 16.26.1040. 4.6-1.0.1.
-``` \ No newline at end of file
diff --git a/docs/lab/testbeds_ucs_hsw_hw_bios_cfg.md b/docs/lab/testbeds_ucs_hsw_hw_bios_cfg.md
deleted file mode 100644
index 8dcd1f0e8c..0000000000
--- a/docs/lab/testbeds_ucs_hsw_hw_bios_cfg.md
+++ /dev/null
@@ -1,740 +0,0 @@
-# Cisco UCS c240m4 Haswell Servers - HW and BIOS Configuration
-
-1. [Linux lscpu](#linux-lscpu)
-1. [Linux dmidecode pci](#linux-dmidecode-pci)
-1. [Linux dmidecode memory](#linux-dmidecode-memory)
-1. [Xeon Hsw Server BIOS Configuration](#xeon-hsw-server-bios-configuration)
-
-## Linux lscpu
-
-```
- $ lscpu
- Architecture: x86_64
- CPU op-mode(s): 32-bit, 64-bit
- Byte Order: Little Endian
- CPU(s): 36
- On-line CPU(s) list: 0-35
- Thread(s) per core: 1
- Core(s) per socket: 18
- Socket(s): 2
- NUMA node(s): 2
- Vendor ID: GenuineIntel
- CPU family: 6
- Model: 63
- Model name: Intel(R) Xeon(R) CPU E5-2699 v3 @ 2.30GHz
- Stepping: 2
- CPU MHz: 2294.249
- BogoMIPS: 4589.82
- Virtualization: VT-x
- L1d cache: 32K
- L1i cache: 32K
- L2 cache: 256K
- L3 cache: 46080K
- NUMA node0 CPU(s): 0-17
- NUMA node1 CPU(s): 18-35
- Flags: fpu vme de pse tsc msr pae mce cx8 apic sep mtrr pge mca cmov pat pse36 clflush dts acpi mmx fxsr sse sse2 ss ht tm pbe syscall nx pdpe1gb rdtscp lm constant_tsc arch_perfmon pebs bts rep_good nopl xtopology nonstop_tsc aperfmperf eagerfpu pni pclmulqdq
- dtes64 monitor ds_cpl vmx smx est tm2 ssse3 sdbg fma cx16 xtpr pdcm pcid dca sse4_1 sse4_2 x2apic movbe popcnt tsc_deadline_timer aes xsave avx f16c rdrand lahf_lm abm epb tpr_shadow vnmi flexpriority ept vpid fsgsbase tsc_adjust bmi1 avx2 smep bmi2 erms invpcid cqm xsaveopt
- cqm_llc cqm_occup_llc dtherm arat pln pts
-```
-
-## Linux dmidecode pci
-
-```
- $ dmidecode --type 9 | grep 'Handle\|Slot\|Type\|Address'
- Handle 0x0046, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:1
- Type: x8 PCI Express 3 x8
- Bus Address: 0000:0a:02.0
- Handle 0x0047, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:2
- Type: x8 PCI Express 3 x8
- Bus Address: 0000:0e:03.2
- Handle 0x0048, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:3
- Type: x8 PCI Express 3 x8
- Bus Address: 0000:0d:03.0
- Handle 0x0049, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:4
- Type: x8 PCI Express 3 x8
- Bus Address: 0000:85:02.2
- Handle 0x004A, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:5
- Type: x8 PCI Express 3 x16
- Bus Address: 0000:87:03.0
- Handle 0x004B, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:6
- Type: x8 PCI Express 3 x8
- Bus Address: 0000:84:02.0
- Handle 0x004C, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:MLOM
- Type: x8 Other
- Bus Address: 0000:01:01.0
- Handle 0x004D, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:HBA
- Type: x8 Other
- Bus Address: 0000:0c:02.2
- Handle 0x004E, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:NVMe1
- Type: x4 PCI Express 3 x4
- Bus Address: 0000:82:01.0
- Handle 0x004F, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:NVMe2
- Type: x4 PCI Express 3 x4
- Bus Address: 0000:83:01.1
- Handle 0x0050, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:2.1
- Type: x16 PCI Express 3 x16
- Bus Address: 0000:00:1f.7
- Handle 0x0051, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:2.2
- Type: x16 PCI Express 3 x16
- Bus Address: 0000:00:1f.7
- Handle 0x0052, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:2.3
- Type: x16 PCI Express 3 x16
- Bus Address: 0000:00:1f.7
- Handle 0x0053, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:2.4
- Type: x16 PCI Express 3 x16
- Bus Address: 0000:00:1f.7
- Handle 0x0054, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:2.5
- Type: x16 PCI Express 3 x16
- Bus Address: 0000:00:1f.7
- Handle 0x0055, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:5.1
- Type: x8 PCI Express 3 x16
- Bus Address: 0000:00:1f.7
- Handle 0x0056, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:5.2
- Type: x8 PCI Express 3 x16
- Bus Address: 0000:00:1f.7
- Handle 0x0057, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:5.3
- Type: x8 PCI Express 3 x16
- Bus Address: 0000:00:1f.7
- Handle 0x0058, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:5.4
- Type: x8 PCI Express 3 x16
- Bus Address: 0000:00:1f.7
- Handle 0x0059, DMI type 9, 17 bytes
- System Slot Information
- Designation: SlotID:5.5
- Type: x8 PCI Express 3 x16
- Bus Address: 0000:00:1f.7
-```
-
-## Linux dmidecode memory
-
-```
- $ dmidecode -t memory
- # dmidecode 2.12
- SMBIOS 2.8 present.
-
- Handle 0x0022, DMI type 16, 23 bytes
- Physical Memory Array
- Location: System Board Or Motherboard
- Use: System Memory
- Error Correction Type: Multi-bit ECC
- Maximum Capacity: 1536 GB
- Error Information Handle: Not Provided
- Number Of Devices: 24
-
- Handle 0x0024, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMM_A1
- Bank Locator: NODE 0 CHANNEL 0 DIMM 0
- Type: Other
- Type Detail: None
- Speed: 2133 MHz
- Manufacturer: 0xAD00
- Serial Number: 80EC7380
- Asset Tag: DIMM_A1_AssetTag
- Part Number: HMA84GL7MMR4N-TF
- Rank: 4
- Configured Clock Speed: 2133 MHz
-
- Handle 0x0025, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMM_A2
- Bank Locator: NODE 0 CHANNEL 0 DIMM 1
- Type: Other
- Type Detail: None
- Speed: 2133 MHz
- Manufacturer: 0xAD00
- Serial Number: 80EC73D1
- Asset Tag: DIMM_A2_AssetTag
- Part Number: HMA84GL7MMR4N-TF
- Rank: 4
- Configured Clock Speed: 2133 MHz
-
- Handle 0x0026, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: Unknown
- Data Width: Unknown
- Size: No Module Installed
- Form Factor: DIMM
- Set: None
- Locator: DIMM_A3
- Bank Locator: NODE 0 CHANNEL 0 DIMM 2
- Type: Other
- Type Detail: None
- Speed: Unknown
- Manufacturer: NO DIMM
- Serial Number: NO DIMM
- Asset Tag: NO DIMM
- Part Number: NO DIMM
- Rank: Unknown
- Configured Clock Speed: Unknown
-
- Handle 0x0027, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMM_B1
- Bank Locator: NODE 0 CHANNEL 1 DIMM 0
- Type: Other
- Type Detail: None
- Speed: 2133 MHz
- Manufacturer: 0xAD00
- Serial Number: 80EC7325
- Asset Tag: DIMM_B1_AssetTag
- Part Number: HMA84GL7MMR4N-TF
- Rank: 4
- Configured Clock Speed: 2133 MHz
-
- Handle 0x0028, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMM_B2
- Bank Locator: NODE 0 CHANNEL 1 DIMM 1
- Type: Other
- Type Detail: None
- Speed: 2133 MHz
- Manufacturer: 0xAD00
- Serial Number: 80EC7334
- Asset Tag: DIMM_B2_AssetTag
- Part Number: HMA84GL7MMR4N-TF
- Rank: 4
- Configured Clock Speed: 2133 MHz
-
- Handle 0x0029, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: Unknown
- Data Width: Unknown
- Size: No Module Installed
- Form Factor: DIMM
- Set: None
- Locator: DIMM_B3
- Bank Locator: NODE 0 CHANNEL 1 DIMM 2
- Type: Other
- Type Detail: None
- Speed: Unknown
- Manufacturer: NO DIMM
- Serial Number: NO DIMM
- Asset Tag: NO DIMM
- Part Number: NO DIMM
- Rank: Unknown
- Configured Clock Speed: Unknown
-
- Handle 0x002A, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMM_C1
- Bank Locator: NODE 0 CHANNEL 2 DIMM 0
- Type: Other
- Type Detail: None
- Speed: 2133 MHz
- Manufacturer: 0xAD00
- Serial Number: 80EC7329
- Asset Tag: DIMM_C1_AssetTag
- Part Number: HMA84GL7MMR4N-TF
- Rank: 4
- Configured Clock Speed: 2133 MHz
-
- Handle 0x002B, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMM_C2
- Bank Locator: NODE 0 CHANNEL 2 DIMM 1
- Type: Other
- Type Detail: None
- Speed: 2133 MHz
- Manufacturer: 0xAD00
- Serial Number: 80EC732D
- Asset Tag: DIMM_C2_AssetTag
- Part Number: HMA84GL7MMR4N-TF
- Rank: 4
- Configured Clock Speed: 2133 MHz
-
- Handle 0x002C, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: Unknown
- Data Width: Unknown
- Size: No Module Installed
- Form Factor: DIMM
- Set: None
- Locator: DIMM_C3
- Bank Locator: NODE 0 CHANNEL 2 DIMM 2
- Type: Other
- Type Detail: None
- Speed: Unknown
- Manufacturer: NO DIMM
- Serial Number: NO DIMM
- Asset Tag: NO DIMM
- Part Number: NO DIMM
- Rank: Unknown
- Configured Clock Speed: Unknown
-
- Handle 0x002D, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMM_D1
- Bank Locator: NODE 0 CHANNEL 3 DIMM 0
- Type: Other
- Type Detail: None
- Speed: 2133 MHz
- Manufacturer: 0xAD00
- Serial Number: 80EC73D3
- Asset Tag: DIMM_D1_AssetTag
- Part Number: HMA84GL7MMR4N-TF
- Rank: 4
- Configured Clock Speed: 2133 MHz
-
- Handle 0x002E, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMM_D2
- Bank Locator: NODE 0 CHANNEL 3 DIMM 1
- Type: Other
- Type Detail: None
- Speed: 2133 MHz
- Manufacturer: 0xAD00
- Serial Number: 80EC7330
- Asset Tag: DIMM_D2_AssetTag
- Part Number: HMA84GL7MMR4N-TF
- Rank: 4
- Configured Clock Speed: 2133 MHz
-
- Handle 0x002F, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: Unknown
- Data Width: Unknown
- Size: No Module Installed
- Form Factor: DIMM
- Set: None
- Locator: DIMM_D3
- Bank Locator: NODE 0 CHANNEL 3 DIMM 2
- Type: Other
- Type Detail: None
- Speed: Unknown
- Manufacturer: NO DIMM
- Serial Number: NO DIMM
- Asset Tag: NO DIMM
- Part Number: NO DIMM
- Rank: Unknown
- Configured Clock Speed: Unknown
-
- Handle 0x0030, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMM_E1
- Bank Locator: NODE 1 CHANNEL 0 DIMM 0
- Type: Other
- Type Detail: None
- Speed: 2133 MHz
- Manufacturer: 0xAD00
- Serial Number: 80E54252
- Asset Tag: DIMM_E1_AssetTag
- Part Number: HMA84GL7MMR4N-TF
- Rank: 4
- Configured Clock Speed: 2133 MHz
-
- Handle 0x0031, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMM_E2
- Bank Locator: NODE 1 CHANNEL 0 DIMM 1
- Type: Other
- Type Detail: None
- Speed: 2133 MHz
- Manufacturer: 0xAD00
- Serial Number: 80E54235
- Asset Tag: DIMM_E2_AssetTag
- Part Number: HMA84GL7MMR4N-TF
- Rank: 4
- Configured Clock Speed: 2133 MHz
-
- Handle 0x0032, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: Unknown
- Data Width: Unknown
- Size: No Module Installed
- Form Factor: DIMM
- Set: None
- Locator: DIMM_E3
- Bank Locator: NODE 1 CHANNEL 0 DIMM 2
- Type: Other
- Type Detail: None
- Speed: Unknown
- Manufacturer: NO DIMM
- Serial Number: NO DIMM
- Asset Tag: NO DIMM
- Part Number: NO DIMM
- Rank: Unknown
- Configured Clock Speed: Unknown
-
- Handle 0x0033, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMM_F1
- Bank Locator: NODE 1 CHANNEL 1 DIMM 0
- Type: Other
- Type Detail: None
- Speed: 2133 MHz
- Manufacturer: 0xAD00
- Serial Number: 80E54218
- Asset Tag: DIMM_F1_AssetTag
- Part Number: HMA84GL7MMR4N-TF
- Rank: 4
- Configured Clock Speed: 2133 MHz
-
- Handle 0x0034, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMM_F2
- Bank Locator: NODE 1 CHANNEL 1 DIMM 1
- Type: Other
- Type Detail: None
- Speed: 2133 MHz
- Manufacturer: 0xAD00
- Serial Number: 80E54236
- Asset Tag: DIMM_F2_AssetTag
- Part Number: HMA84GL7MMR4N-TF
- Rank: 4
- Configured Clock Speed: 2133 MHz
-
- Handle 0x0035, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: Unknown
- Data Width: Unknown
- Size: No Module Installed
- Form Factor: DIMM
- Set: None
- Locator: DIMM_F3
- Bank Locator: NODE 1 CHANNEL 1 DIMM 2
- Type: Other
- Type Detail: None
- Speed: Unknown
- Manufacturer: NO DIMM
- Serial Number: NO DIMM
- Asset Tag: NO DIMM
- Part Number: NO DIMM
- Rank: Unknown
- Configured Clock Speed: Unknown
-
- Handle 0x0036, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMM_G1
- Bank Locator: NODE 1 CHANNEL 2 DIMM 0
- Type: Other
- Type Detail: None
- Speed: 2133 MHz
- Manufacturer: 0xAD00
- Serial Number: 80E54247
- Asset Tag: DIMM_G1_AssetTag
- Part Number: HMA84GL7MMR4N-TF
- Rank: 4
- Configured Clock Speed: 2133 MHz
-
- Handle 0x0037, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMM_G2
- Bank Locator: NODE 1 CHANNEL 2 DIMM 1
- Type: Other
- Type Detail: None
- Speed: 2133 MHz
- Manufacturer: 0xAD00
- Serial Number: 80E5421E
- Asset Tag: DIMM_G2_AssetTag
- Part Number: HMA84GL7MMR4N-TF
- Rank: 4
- Configured Clock Speed: 2133 MHz
-
- Handle 0x0038, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: Unknown
- Data Width: Unknown
- Size: No Module Installed
- Form Factor: DIMM
- Set: None
- Locator: DIMM_G3
- Bank Locator: NODE 1 CHANNEL 2 DIMM 2
- Type: Other
- Type Detail: None
- Speed: Unknown
- Manufacturer: NO DIMM
- Serial Number: NO DIMM
- Asset Tag: NO DIMM
- Part Number: NO DIMM
- Rank: Unknown
- Configured Clock Speed: Unknown
-
- Handle 0x0039, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMM_H1
- Bank Locator: NODE 1 CHANNEL 3 DIMM 0
- Type: Other
- Type Detail: None
- Speed: 2133 MHz
- Manufacturer: 0xAD00
- Serial Number: 80E5423C
- Asset Tag: DIMM_H1_AssetTag
- Part Number: HMA84GL7MMR4N-TF
- Rank: 4
- Configured Clock Speed: 2133 MHz
-
- Handle 0x003A, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: 72 bits
- Data Width: 64 bits
- Size: 32 GB
- Form Factor: DIMM
- Set: None
- Locator: DIMM_H2
- Bank Locator: NODE 1 CHANNEL 3 DIMM 1
- Type: Other
- Type Detail: None
- Speed: 2133 MHz
- Manufacturer: 0xAD00
- Serial Number: 80E5424D
- Asset Tag: DIMM_H2_AssetTag
- Part Number: HMA84GL7MMR4N-TF
- Rank: 4
- Configured Clock Speed: 2133 MHz
-
- Handle 0x003B, DMI type 17, 34 bytes
- Memory Device
- Array Handle: 0x0022
- Error Information Handle: Not Provided
- Total Width: Unknown
- Data Width: Unknown
- Size: No Module Installed
- Form Factor: DIMM
- Set: None
- Locator: DIMM_H3
- Bank Locator: NODE 1 CHANNEL 3 DIMM 2
- Type: Other
- Type Detail: None
- Speed: Unknown
- Manufacturer: NO DIMM
- Serial Number: NO DIMM
- Asset Tag: NO DIMM
- Part Number: NO DIMM
- Rank: Unknown
- Configured Clock Speed: Unknown
-```
-
-## Xeon Hsw Server BIOS Configuration
-
-```
- C240 / # scope bios
- C240 /bios # show advanced detail
- Set-up parameters:
- Intel(R) VT-d ATS Support: Enabled
- Adjacent Cache Line Prefetcher: Enabled
- All Onboard LOM Ports: Enabled
- Altitude: 300 M
- Bits per second: 115200
- Power Technology: Performance
- Channel Interleaving: Auto
- Intel(R) VT-d Coherency Support: Disabled
- Console Redirection: COM 0
- Number of Enabled Cores: All
- Energy Performance: Performance
- CPU Performance: Enterprise
- DCU IP Prefetcher: Enabled
- DCU Streamer Prefetch: Enabled
- Demand Scrub: Enabled
- Direct Cache Access Support: Auto
- Enhanced Intel Speedstep(R) Tec: Disabled
- Execute Disable: Enabled
- Flow Control: None
- Hardware Prefetcher: Enabled
- Intel(R) Hyper-Threading Techno: Disabled
- Intel(R) Turbo Boost Technology: Disabled
- Intel(R) VT: Enabled
- Intel(R) VT-d: Enabled
- Intel(R) Interrupt Remapping: Enabled
- Legacy USB Support: Enabled
- Extended APIC: XAPIC
- LOM Port 1 OptionROM: Enabled
- LOM Port 2 OptionROM: Enabled
- MMIO above 4GB: Enabled
- NUMA: Enabled
- PCI ROM CLP: Disabled
- Package C State Limit: C6 Retention
- Intel(R) Pass Through DMA: Disabled
- Patrol Scrub: Enabled
- xHCI Mode: Disabled
- All PCIe Slots OptionROM: Enabled
- PCIe Slot:1 OptionROM: Disabled
- PCIe Slot:2 OptionROM: Disabled
- PCIe Slot:3 OptionROM: Disabled
- PCIe Slot:4 OptionROM: Disabled
- PCIe Slot:5 OptionROM: Disabled
- PCIe Slot:6 OptionROM: Disabled
- PCIe Slot:HBA Link Speed: GEN3
- PCIe Slot:HBA OptionROM: Enabled
- PCIe Slot:MLOM OptionROM: Enabled
- PCIe Slot:N1 OptionROM: Enabled
- PCIe Slot:N2 OptionROM: Enabled
- Processor Power state C1 Enhanc: Disabled
- Processor C3 Report: Disabled
- Processor C6 Report: Disabled
- P-STATE Coordination: HW ALL
- Putty KeyPad: ESCN
- Energy Performance Tuning: BIOS
- QPI Link Frequency Select: Auto
- QPI Snoop Mode: Home Snoop
- Rank Interleaving: Auto
- Redirection After BIOS POST: Always Enable
- PCH SATA Mode: AHCI
- Select Memory RAS: Maximum Performance
- SR-IOV Support: Enabled
- Terminal Type: VT100
- Port 60/64 Emulation: Enabled
- Workload Configuration: Balanced
- CDN Support for VIC: Disabled
- Out-of-Band Management: Disabled
- C240-FCH1950V1H5 /bios/advanced #
-```