diff options
Diffstat (limited to 'topologies/available/lf_3n_icx_testbed37.yaml')
-rw-r--r-- | topologies/available/lf_3n_icx_testbed37.yaml | 69 |
1 files changed, 35 insertions, 34 deletions
diff --git a/topologies/available/lf_3n_icx_testbed37.yaml b/topologies/available/lf_3n_icx_testbed37.yaml index 9b9ddfeeeb..1a12c36e74 100644 --- a/topologies/available/lf_3n_icx_testbed37.yaml +++ b/topologies/available/lf_3n_icx_testbed37.yaml @@ -4,13 +4,13 @@ metadata: schema: - resources/topology_schemas/3_node_topology.sch.yaml - resources/topology_schemas/topology.sch.yaml - tags: [hw, 3-node] nodes: TG: type: TG subtype: TREX - host: "10.30.51.77" + model: Intel-Icelake + host: 10.30.51.77 arch: x86_64 port: 6001 username: testuser @@ -20,7 +20,7 @@ nodes: # s77-t37-tg1-c9/p1 - 100GE port1 Intel E810-CQDA2 2p100GE. mac_address: "b4:96:91:b2:a1:48" pci_address: "0000:17:00.0" - ip4_address: "172.16.10.1" + ip4_address: 172.16.10.1 driver: ice link: link1 model: Intel-E810CQ @@ -28,7 +28,7 @@ nodes: # s77-t37-tg1-c9/p2 - 100GE port2 Intel E810-CQDA2 2p100GE. mac_address: "b4:96:91:b2:a1:49" pci_address: "0000:17:00.1" - ip4_address: "172.16.20.1" + ip4_address: 172.16.20.1 driver: ice link: link2 model: Intel-E810CQ @@ -36,7 +36,7 @@ nodes: # s77-t37-tg1-c4/p1 - 25GE port1 Intel E810-XXVDA4 4p25GE. mac_address: "b4:96:91:a5:78:ec" pci_address: "0000:31:00.0" - ip4_address: "172.16.30.1" + ip4_address: 172.16.30.1 driver: ice link: link3 model: Intel-E810XXV @@ -44,7 +44,7 @@ nodes: # s77-t37-tg1-c4/p2 - 25GE port2 Intel E810-XXVDA4 4p25GE. mac_address: "b4:96:91:a5:78:ed" pci_address: "0000:31:00.1" - ip4_address: "172.16.40.1" + ip4_address: 172.16.40.1 driver: ice link: link4 model: Intel-E810XXV @@ -52,7 +52,7 @@ nodes: # s77-t37-tg1-c4/p3 - 25GE port3 Intel E810-XXVDA4 4p25GE. mac_address: "b4:96:91:a5:78:ee" pci_address: "0000:31:00.2" - ip4_address: "172.16.50.1" + ip4_address: 172.16.50.1 driver: ice link: link5 model: Intel-E810XXV @@ -60,7 +60,7 @@ nodes: # s77-t37-tg1-c4/p4 - 25GE port4 Intel E810-XXVDA4 4p25GE. mac_address: "b4:96:91:a5:78:ef" pci_address: "0000:31:00.3" - ip4_address: "172.16.60.1" + ip4_address: 172.16.60.1 driver: ice link: link6 model: Intel-E810XXV @@ -68,7 +68,7 @@ nodes: # s77-t37-tg1-c2/p1 - 25GE port1 Intel NIC x710 2p25GE. mac_address: "3c:fd:fe:bd:fa:24" pci_address: "0000:4b:00.0" - ip4_address: "172.16.70.1" + ip4_address: 172.16.70.1 driver: i40e link: link7 model: Intel-XXV710 @@ -76,7 +76,7 @@ nodes: # s77-t37-tg1-c2/p2 - 25GE port2 Intel NIC x710 2p25GE. mac_address: "3c:fd:fe:bd:fa:25" pci_address: "0000:4b:00.1" - ip4_address: "172.16.80.1" + ip4_address: 172.16.80.1 driver: i40e link: link8 model: Intel-XXV710 @@ -84,7 +84,7 @@ nodes: # s77-t37-tg1-c10/p1 - 100GE port1 Mellanox ConnectX-6 Dx 2p100GE. mac_address: "b8:3f:d2:13:0f:a6" pci_address: "0000:e3:00.0" - ip4_address: "172.16.90.1" + ip4_address: 172.16.90.1 driver: mlx5_core link: link9 model: Mellanox-CX6DX @@ -92,13 +92,14 @@ nodes: # s77-t37-tg1-c10/p2 - 100GE port2 Mellanox ConnectX-6 Dx 2p100GE. mac_address: "b8:3f:d2:13:0f:a7" pci_address: "0000:e3:00.1" - ip4_address: "172.16.100.1" + ip4_address: 172.16.100.1 driver: mlx5_core link: link10 model: Mellanox-CX6DX DUT1: type: DUT - host: "10.30.51.75" + model: Intel-Icelake + host: 10.30.51.75 arch: x86_64 port: 22 username: testuser @@ -109,7 +110,7 @@ nodes: # s75-t37-sut1-c9/p1 - 100GE port1 Intel E810-CQDA2 2p100GE. mac_address: "b4:96:91:b2:a7:b0" pci_address: "0000:17:00.0" - ip4_address: "172.16.10.2" + ip4_address: 172.16.10.2 driver: ice link: link1 model: Intel-E810CQ @@ -117,7 +118,7 @@ nodes: # s75-t37-sut1-c9/p2 - 100GE port2 Intel E810-CQDA2 2p100GE. mac_address: "b4:96:91:b2:a7:b1" pci_address: "0000:17:00.1" - ip4_address: "172.16.20.2" + ip4_address: 172.16.20.2 driver: ice link: link22 model: Intel-E810CQ @@ -125,7 +126,7 @@ nodes: # s75-t37-sut1-c4/p1 - 25GE port1 Intel E810-XXVDA4 4p25GE. mac_address: "b4:96:91:a5:77:60" pci_address: "0000:31:00.0" - ip4_address: "172.16.30.2" + ip4_address: 172.16.30.2 driver: ice link: link3 model: Intel-E810XXV @@ -133,7 +134,7 @@ nodes: # s75-t37-sut1-c4/p2 - 25GE port2 Intel E810-XXVDA4 4p25GE. mac_address: "b4:96:91:a5:77:61" pci_address: "0000:31:00.1" - ip4_address: "172.16.40.2" + ip4_address: 172.16.40.2 driver: ice link: link44 model: Intel-E810XXV @@ -141,7 +142,7 @@ nodes: # s75-t37-sut1-c4/p3 - 25GE port3 Intel E810-XXVDA4 4p25GE. mac_address: "b4:96:91:a5:77:62" pci_address: "0000:31:00.2" - ip4_address: "172.16.50.2" + ip4_address: 172.16.50.2 driver: ice link: link5 model: Intel-E810XXV @@ -149,7 +150,7 @@ nodes: # s75-t37-sut1-c4/p4 - 25GE port4 Intel E810-XXVDA4 4p25GE. mac_address: "b4:96:91:a5:77:63" pci_address: "0000:31:00.3" - ip4_address: "172.16.60.2" + ip4_address: 172.16.60.2 driver: ice link: link66 model: Intel-E810XXV @@ -157,7 +158,7 @@ nodes: # s75-t37-sut1-c2/p1 - 25GE port1 Intel NIC xxv710 2p25GE. mac_address: "3c:fd:fe:bd:f8:68" pci_address: "0000:4b:00.0" - ip4_address: "172.16.70.2" + ip4_address: 172.16.70.2 driver: i40e link: link7 model: Intel-XXV710 @@ -165,7 +166,7 @@ nodes: # s75-t37-sut1-c2/p2 - 25GE port2 Intel NIC xxv710 2p25GE. mac_address: "3c:fd:fe:bd:f8:69" pci_address: "0000:4b:00.1" - ip4_address: "172.16.80.2" + ip4_address: 172.16.80.2 driver: i40e link: link88 model: Intel-XXV710 @@ -173,7 +174,7 @@ nodes: # s77-t37-sut1-c10/p1 - 100GE port1 Mellanox ConnectX-6 Dx 2p100GE. mac_address: "b8:3f:d2:13:0f:2e" pci_address: "0000:e3:00.0" - ip4_address: "172.16.90.2" + ip4_address: 172.16.90.2 driver: mlx5_core link: link1010 model: Mellanox-CX6DX @@ -181,13 +182,13 @@ nodes: # s77-t37-sut1-c10/p2 - 100GE port2 Mellanox ConnectX-6 Dx 2p100GE. mac_address: "b8:3f:d2:13:0f:2f" pci_address: "0000:e3:00.1" - ip4_address: "172.16.100.2" + ip4_address: 172.16.100.2 driver: mlx5_core link: link9 model: Mellanox-CX6DX DUT2: type: DUT - host: "10.30.51.76" + host: 10.30.51.76 arch: x86_64 port: 22 username: testuser @@ -198,7 +199,7 @@ nodes: # s76-t37-sut2-c9/p1 - 100GE port1 Intel E810-CQDA2 2p100GE. mac_address: "40:a6:b7:67:27:54" pci_address: "0000:17:00.0" - ip4_address: "172.16.10.3" + ip4_address: 172.16.10.3 driver: ice link: link2 model: Intel-E810CQ @@ -206,7 +207,7 @@ nodes: # s76-t37-sut2-c9/p2 - 100GE port2 Intel E810-CQDA2 2p100GE. mac_address: "40:a6:b7:67:27:50" pci_address: "0000:19:00.0" - ip4_address: "172.16.20.3" + ip4_address: 172.16.20.3 driver: ice link: link22 model: Intel-E810CQ @@ -214,7 +215,7 @@ nodes: # s76-t37-sut2-c4/p1 - 25GE port1 Intel E810-XXVDA4 4p25GE. mac_address: "b4:96:91:a5:78:24" pci_address: "0000:31:00.0" - ip4_address: "172.16.30.3" + ip4_address: 172.16.30.3 driver: ice link: link4 model: Intel-E810XXV @@ -222,7 +223,7 @@ nodes: # s76-t37-sut2-c4/p2 - 25GE port2 Intel E810-XXVDA4 4p25GE. mac_address: "b4:96:91:a5:78:25" pci_address: "0000:31:00.1" - ip4_address: "172.16.40.3" + ip4_address: 172.16.40.3 driver: ice link: link44 model: Intel-E810XXV @@ -230,7 +231,7 @@ nodes: # s76-t37-sut2-c4/p3 - 25GE port3 Intel E810-XXVDA4 4p25GE. mac_address: "b4:96:91:a5:78:26" pci_address: "0000:31:00.2" - ip4_address: "172.16.50.3" + ip4_address: 172.16.50.3 driver: ice link: link6 model: Intel-E810XXV @@ -238,7 +239,7 @@ nodes: # s76-t37-sut2-c4/p4 - 25GE port4 Intel E810-XXVDA4 4p25GE. mac_address: "b4:96:91:a5:78:27" pci_address: "0000:31:00.3" - ip4_address: "172.16.60.3" + ip4_address: 172.16.60.3 driver: ice link: link66 model: Intel-E810XXV @@ -246,7 +247,7 @@ nodes: # s76-t37-sut2-c2/p1 - 25GE port1 Intel NIC xxv710 2p25GE. mac_address: "3c:fd:fe:bd:f9:f4" pci_address: "0000:4b:00.0" - ip4_address: "172.16.70.3" + ip4_address: 172.16.70.3 driver: i40e link: link8 model: Intel-XXV710 @@ -254,7 +255,7 @@ nodes: # s76-t37-sut2-c2/p2 - 25GE port2 Intel NIC xxv710 2p25GE. mac_address: "3c:fd:fe:bd:f9:f5" pci_address: "0000:4b:00.1" - ip4_address: "172.16.80.3" + ip4_address: 172.16.80.3 driver: i40e link: link88 model: Intel-XXV710 @@ -262,7 +263,7 @@ nodes: # s76-t37-sut2-c10/p1 - 100GE port1 Mellanox ConnectX-6 Dx 2p100GE. mac_address: "b8:3f:d2:13:4b:16" pci_address: "0000:e3:00.0" - ip4_address: "172.16.100.3" + ip4_address: 172.16.100.3 driver: mlx5_core link: link10 model: Mellanox-CX6DX @@ -270,7 +271,7 @@ nodes: # s76-t37-sut2-c10/p2 - 100GE port2 Mellanox ConnectX-6 Dx 2p100GE. mac_address: "b8:3f:d2:13:4b:17" pci_address: "0000:e3:00.1" - ip4_address: "172.16.90.3" + ip4_address: 172.16.90.3 driver: mlx5_core link: link1010 model: Mellanox-CX6DX
\ No newline at end of file |