CSIT Release Notes
==================
Changes in CSIT |release|
-------------------------
#. Added Testpmd tests
- new NICs - 2p40GE Intel xl710, 2p10GE Intel x710
Known Issues
------------
Here is the list of known issues in CSIT |release| for Testpmd performance tests:
+---+---------------------------------------------------+------------+-----------------------------------------------------------------+
| # | Issue | Jira ID | Description |
+---+---------------------------------------------------+------------+-----------------------------------------------------------------+
| 1 | Testpmd in 1t1c and 2t2c setups - large variation | CSIT-568 | Suspected NIC firmware or DPDK driver issue affecting NDR |
| | of discovered NDR throughput values across | | throughput. Applies to XL710 and X710 NICs, no issues observed |
| | multiple test runs with xl710 and x710 NICs. | | on x520 NICs. |
+---+---------------------------------------------------+------------+-----------------------------------------------------------------+
| 2 | Lower than expected NDR throughput with xl710 | CSIT-? | Suspected NIC firmware or DPDK driver issue affecting NDR |
| | and x710 NICs, compared to x520 NICs. | | throughput. Applies to XL710 and X710 NICs. |
+---+---------------------------------------------------+------------+-----------------------------------------------------------------+
|