diff options
author | Peter Mikus <peter.mikus@protonmail.ch> | 2024-09-10 11:39:59 +0200 |
---|---|---|
committer | Peter Mikus <peter.mikus@protonmail.ch> | 2024-09-10 14:24:44 +0000 |
commit | 142870a1fabc9db136f117498591eab5cb7e541c (patch) | |
tree | 94d01c74d89e4acd26f59e6bcc4f8d444a3b0a50 | |
parent | 4cab0434ed664b1757c72937a3daf54ba4853bdd (diff) |
feat(infra): Update
Signed-off-by: Peter Mikus <peter.mikus@protonmail.ch>
Change-Id: I63064cf1b29d59ea69024d41e9a9f27e17bee12a
3 files changed, 128 insertions, 37 deletions
diff --git a/docs/content/infrastructure/fdio_dc_testbed_specifications.md b/docs/content/infrastructure/fdio_dc_testbed_specifications.md index 8a1c13e8ca..831cee47e4 100644 --- a/docs/content/infrastructure/fdio_dc_testbed_specifications.md +++ b/docs/content/infrastructure/fdio_dc_testbed_specifications.md @@ -39,20 +39,20 @@ To access these hosts, VPN connection is required. ### Summary List ``` - #. Type Purpose SUT TG #TB #SUT #TG #skx #ps1 #rng #tx2 #tsh #alt #clx #zn2 #icx #snr #spr #icxd - 1. 1-Node-Skylake nomad skx na 2 2 0 2 0 0 0 0 0 0 0 0 0 0 0 - 2. 1-Node-Cascadelake nomad clx na 4 4 0 0 0 0 0 0 0 4 0 0 0 0 0 - 3. 1-Node-AmpereAltra nomad alt na 4 4 0 0 0 0 0 0 4 0 0 0 0 0 0 - 4. 2-Node-Cascadelake perf clx clx 0 0 1 0 0 0 0 0 0 1 0 0 0 0 0 - 5. 2-Node-Icelake perf icx icx 4 4 4 0 0 0 0 0 0 0 0 8 0 0 0 - 6. 3-Node-Rangeley perf rng skx 1 3 1 0 0 2 0 0 0 0 0 0 0 0 0 - 7. 3-Node-Altra perf alt icx 1 2 1 0 0 0 0 0 2 0 0 1 0 0 0 - 8. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 2 0 0 0 0 - 9. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 6 0 0 0 -10. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 0 0 .5 2 0 0 -11. 2-Node-SapphireRapids perf spr spr 4 4 4 0 0 0 0 0 0 0 0 0 0 8 0 -12. 1-Node-SapphireRapids nomad spr na 4 4 0 0 0 0 0 0 0 0 0 0 0 4 0 -13. 3-Node-IcelakeD perf icxd icx 4 6 1 0 0 0 0 0 0 0 0 1 0 0 4 + #. Type Purpose SUT TG #TB #SUT #TG #skx #ps1 #rng #tx2 #tsh #alt #clx #zn2 #icx #snr #spr #icxd #grc + 1. 1-Node-Skylake nomad skx na 2 2 0 2 0 0 0 0 0 0 0 0 0 0 0 0 + 2. 1-Node-Cascadelake nomad clx na 4 4 0 0 0 0 0 0 0 4 0 0 0 0 0 0 + 3. 1-Node-AmpereAltra nomad alt na 4 4 0 0 0 0 0 0 4 0 0 0 0 0 0 0 + 4. 1-Node-SapphireRapids nomad spr na 4 4 0 0 0 0 0 0 0 0 0 0 0 4 0 0 + 6. 2-Node-Icelake perf icx icx 3 3 3 0 0 0 0 0 0 0 0 6 0 0 0 0 + 7. 2-Node-Octeon perf icx icx 1 1 1 0 0 0 0 0 0 0 0 2 0 0 0 0 + 8. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 2 0 0 0 0 0 + 9. 3-Node-Altra perf alt icx 1 2 1 0 0 0 0 0 2 0 0 1 0 0 0 0 +10. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 6 0 0 0 0 +11. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 0 0 .5 2 0 0 0 +12. 2-Node-SapphireRapids perf spr spr 4 4 4 0 0 0 0 0 0 0 0 0 0 8 0 0 +13. 3-Node-IcelakeD perf icxd icx 2 4 1 0 0 0 0 0 0 0 0 1 0 0 4 0 +14. 2-Node-Grace perf grc icx 1 1 1 0 0 0 0 0 0 0 0 1 0 0 0 1 ``` ### 1-Node-Altra Arm Ampere (1n-alt) @@ -81,6 +81,20 @@ one TG (Server-Type-F2) connected in a 2-node circular topology ([Server Types](#server-types)). Used for FD.io performance tests. +### 2-Node-Icelake Xeon Intel (2n-oct) + +Each 2-Node-Icelake testbed includes one SUT (Server-Type-XX) and +one TG (Server-Type-XX) connected in a 2-node circular topology +([Server Types](#server-types)). +Used for FD.io performance tests. + +### 2-Node-Grace Server Nvidia (2n-grc) + +Each 2-Node-Grace testbed includes one SUT (Server-Type-XX) and +one TG (Server-Type-F6) connected in a 2-node circular topology +([Server Types](#server-types)). +Used for FD.io performance tests. + ### 3-Node-Altra Arm Ampere (3n-alt) Each 3-Node-Altra testbed includes two SUTs (Server-Type-E23) and one @@ -432,7 +446,28 @@ FD.io CSIT lab contains following server types: - PCIe Slot8 b1:00.xx: e810-2CQDA2-2p100GE Intel. - PCIe Slot10 ff:00.xx: empty. -15. **Server-Type-G1**: Purpose - SnowRidge Atom SUT for FD.io performance testing. +15. **Server-Type-F6**: Purpose - Icelake Xeon TG for FD.io performance testing. + - Quantity: 1. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node and/or 3-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-740GP-TNRT. + - Motherboard: Super X12DPG-QT6. + - Processors: 2* Intel Platinum 8358 2.6 GHz. + - RAM Memory: 16* 16GB DDR4-3200. + - Disks: 2* 960GB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe4.0 lanes) + - PCIe Slot2 4b:00.xx: ConnectX5-2p100GE Mellanox. + - PCIe Slot4 31:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. + - PCIe Slot9 ff:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. + - Numa1: (x16, x16, x16 PCIe4.0 lanes) + - PCIe Slot6 ca:00.xx: empty. + - PCIe Slot8 b1:00.xx: empty. + - PCIe Slot10 ff:00.xx: empty. + +16. **Server-Type-G1**: Purpose - SnowRidge Atom SUT for FD.io performance testing. - Quantity: 2 - Physical connectivity: - IPMI and host management ports. @@ -447,7 +482,7 @@ FD.io CSIT lab contains following server types: - Numa0: (x16, PCIe3.0 lane) - PCIe BuiltIn ec:00.xx: e810-XXVDA4-4p25GE Intel. -16. **Server-Type-H1**: Purpose - SapphireRapids Xeon SUT for FD.io full system performance testing. +17. **Server-Type-H1**: Purpose - SapphireRapids Xeon SUT for FD.io full system performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -468,7 +503,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot9 af:00.xx: ConnectX7-2p200GE Nvidia. - PCIe Slot11 d8:00.xx: ConnectX7-2p200GE Nvidia. -17. **Server-Type-H2**: Purpose - SapphireRapids Xeon TG for FD.io full system performance testing. +18. **Server-Type-H2**: Purpose - SapphireRapids Xeon TG for FD.io full system performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -489,7 +524,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot9 af:00.xx: ConnectX7-2p200GE Nvidia. - PCIe Slot11 d8:00.xx: empty. -18. **Server-Type-H3**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing. +19. **Server-Type-H3**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -510,7 +545,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot9 af:00.xx: e810-XXVDA4-4p25GE Intel. - PCIe Slot11 d8:00.xx: empty. -19. **Server-Type-H4**: Purpose - SapphireRapids Xeon TG for FD.io performance testing. +20. **Server-Type-H4**: Purpose - SapphireRapids Xeon TG for FD.io performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -531,7 +566,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot9 af:00.xx: empty. - PCIe Slot11 d8:00.xx: empty. -20. **Server-Type-H5**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing. +21. **Server-Type-H5**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing. - Quantity: 2. - Physical connectivity: - IPMI and host management ports. @@ -552,7 +587,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot9 af:00.xx: empty. - PCIe Slot11 d8:00.xx: empty. -21. **Server-Type-H6**: Purpose - SapphireRapids Xeon TG for FD.io performance testing. +22. **Server-Type-H6**: Purpose - SapphireRapids Xeon TG for FD.io performance testing. - Quantity: 2. - Physical connectivity: - IPMI and host management ports. @@ -573,7 +608,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot9 af:00.xx: e810-2CQDA2-2p100GE Intel. - PCIe Slot11 d8:00.xx: empty. -22. **Server-Type-H7**: Purpose - SapphireRapids SUT for FD.io VPP_Device functional tests. +23. **Server-Type-H7**: Purpose - SapphireRapids SUT for FD.io VPP_Device functional tests. - Quantity: 2. - Physical connectivity: - IPMI and host management ports. @@ -594,7 +629,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot9 af:00.xx: empty. - PCIe Slot11 d8:00.xx: empty. -23. **Server-Type-I1**: Purpose - IcelakeD Xeon SUT for FD.io performance testing. +24. **Server-Type-I1**: Purpose - IcelakeD Xeon SUT for FD.io performance testing. - Quantity: 4 - Physical connectivity: - IPMI and host management ports. @@ -609,6 +644,23 @@ FD.io CSIT lab contains following server types: - Numa0: (x16, PCIe4.0 lane) - PCIe BuiltIn ??:00.xx: e810-XXVDA2-2p25GE Intel. +25. **Server-Type-J1**: Purpose - Grace Server SUT for FD.io performance testing. + - Quantity: 1. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node and/or 3-node testbed topologies. + - Main HW configuration: + - Chassis: NDA. + - Motherboard: NDA. + - Processors: 1* Arm Neoverse V2. + - RAM Memory: NDA. + - Disks: NDA. + - NICs configuration: + - Numa0: (x16, x16, x16, x16 PCIe5.0 lanes) + - PCIe Slot2 ?: ConnectX5-2p100GE Mellanox. + - PCIe Slot4 ?: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. + - PCIe Slot9 ?: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. + ## Testbeds Configuration ### 1-Node-Skylake (1n-skx) @@ -1293,6 +1345,35 @@ FD.io CSIT lab contains following server types: - s90-t31t32-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE. ``` +### 2-Node-Grace (2n-grc) + +``` +- SUT [Server-Type-J1]: + - testbedname: testbed27. + - hostname: s36-t27-sut1. + - IPMI IP: 10.30.50.36 + - Host IP: 10.30.51.36 + - portnames: + - s36-t27-sut1-c2/p1 - 100GE-port1 ConnectX5-2p100GE. + - s36-t27-sut1-c2/p2 - 100GE-port2 ConnectX5-2p100GE. + - s36-t27-sut1-c4/p1 - 200GE-port1 ConnectX7-2p200GE. + - s36-t27-sut1-c4/p2 - 200GE-port2 ConnectX7-2p200GE. + - s36-t27-sut1-c9/p1 - 200GE-port1 ConnectX7-2p200GE. + - s36-t27-sut1-c9/p2 - 200GE-port2 ConnectX7-2p200GE. +- TG [Server-Type-F6]: + - testbedname: testbed27. + - hostname: s37-t27-tg1. + - IPMI IP: 10.30.50.37 + - Host IP: 10.30.51.37 + - portnames: + - s37-t27-tg1-c2/p1 - 100GE-port1 ConnectX5-2p100GE. + - s37-t27-tg1-c2/p2 - 100GE-port2 ConnectX5-2p100GE. + - s37-t27-tg1-c4/p1 - 200GE-port1 ConnectX7-2p200GE. + - s37-t27-tg1-c4/p2 - 200GE-port2 ConnectX7-2p200GE. + - s37-t27-tg1-c9/p1 - 200GE-port1 ConnectX7-2p200GE. + - s37-t27-tg1-c9/p2 - 200GE-port2 ConnectX7-2p200GE. +``` + ## Testbed Wiring ### 1-Node-Altra (1n-alt) @@ -1454,13 +1535,6 @@ FD.io CSIT lab contains following server types: - s87-t215-sut1-c8/p2 to s88-t215-tg1-c8/p2. ``` -### 3-Node-Rangeley (3n-rng) - -``` -To be completed. -``` - - ### 3-Node-Altra (3n-alt) ``` @@ -1605,4 +1679,19 @@ To be completed. - s90-t31t32-tg1-c6/p1 to s34-t32-sut1-c1/p1. - s34-t32-sut1-c1/p2 to s35-t32-sut2-c1/p2. - s35-t32-sut2-c1/p1 to s90-t31t32-tg1-c6/p2. +``` + +### 2-Node-GraceServer (2n-grc) + +``` +- testbed27: + - ring1 100GE-ports ConnectX5-2p100GE: + - s37-t27-tg1-c2/p1 to s36-t27-sut1-c1/p1. + - s36-t27-sut1-c1/p2 to s37-t27-tg1-c2/p2. + - ring2 200GE-ports ConnectX7-2p200GE: + - s37-t27-tg1-c2/p1 to s36-t27-sut1-c1/p1. + - s36-t27-sut1-c1/p2 to s37-t27-tg1-c2/p2. + - ring3 200GE-ports ConnectX7-2p200GE: + - s37-t27-tg1-c2/p1 to s36-t27-sut1-c1/p1. + - s36-t27-sut1-c1/p2 to s37-t27-tg1-c2/p2. ```
\ No newline at end of file diff --git a/docs/content/infrastructure/fdio_dc_vexxhost_inventory.md b/docs/content/infrastructure/fdio_dc_vexxhost_inventory.md index bfb42001d7..bd12845fe7 100644 --- a/docs/content/infrastructure/fdio_dc_vexxhost_inventory.md +++ b/docs/content/infrastructure/fdio_dc_vexxhost_inventory.md @@ -69,7 +69,7 @@ Captured inventory data: s90-t31t32-tg1 | 3n-icxd | SYS-740GP-TNRT | C7470KL03P50184 | 10.30.51.90 | 10.30.50.90 | 3016.10 | u14-u17 s93-t39-sut1 | 3n-snr | ? | ? | 10.30.51.93 | 10.30.50.93 | 3016.10 | u10-u13 s94-t39-sut2 | 3n-snr | ? | ? | 10.30.51.94 | 10.30.50.94 | 3016.10 | u6-u9 - s89-t39t310-tg1 | 3n-snr | ? | ? | 10.30.51.89 | 10.30.50.89 | 3016.10 | u2-u5 + s89-t39t310-tg1 | 3n-snr | SYS-7049GP-TRT | C7470KH37A30506 | 10.30.51.89 | 10.30.50.89 | 3016.10 | u2-u5 ### Rack YUL1-11 (3016.11) @@ -98,11 +98,11 @@ Captured inventory data: s27-nomad | nomad-client | SYS-7049GP-TRT | C7470KH06A20055 | 10.30.51.27 | 10.30.50.27 | 3016.12 | u37-u40 s91-nomad | nomad-client | R152-P30-00 | GLG4P9912A0016 | 10.30.51.91 | 10.30.50.91 | 3016.12 | u36 s92-nomad | nomad-client | R152-P30-00 | GLG4P9912A0004 | 10.30.51.92 | 10.30.50.92 | 3016.12 | u35 - s23-nomad | nomad-server | SYS-1029P-WTRT | C1160LI12NM0256 | 10.30.51.23 | 10.30.51.23 | 3016.12 | u34 - s24-nomad | nomad-server | SYS-1029P-WTRT | C1160LI12NM0241 | 10.30.51.24 | 10.30.51.24 | 3016.12 | u33 - s25-nomad | nomad-server | SYS-1029P-WTRT | C1160LI12NM0540 | 10.30.51.25 | 10.30.51.25 | 3016.12 | u32 + s23-nomad | nomad-server | SYS-1029P-WTRT | C1160LI12NM0256 | 10.30.51.23 | 10.30.50.23 | 3016.12 | u34 + s24-nomad | nomad-server | SYS-1029P-WTRT | C1160LI12NM0241 | 10.30.51.24 | 10.30.50.24 | 3016.12 | u33 + s25-nomad | nomad-server | SYS-1029P-WTRT | C1160LI12NM0540 | 10.30.51.25 | 10.30.50.25 | 3016.12 | u32 s61-t210-tg1 | 2n-zn2 | AS-1014S-WTRT | C8150LI50NS2689 | 10.32.8.25 | 10.30.55.25 | 3016.12 | u31 s60-t210-sut1 | 2n-zn2 | AS-1114S-WTRT | N/A | 10.32.8.24 | 10.30.55.24 | 3016.12 | u30 - s26-nomad | nomad-server | SYS-7049GP-TRT | C7470KH37A30505 | 10.30.51.26 | 10.30.51.26 | 3016.12 | u26-u29 - -- | -- | -- | -- | -- | -- | 3016.12 | u6-u9 - s38-t29-tg1 | 2n-clx | SYS-7049GP-TRT | C7470KH37A30506 | 10.32.8.23 | 10.30.55.23 | 3016.12 | u2-u5
\ No newline at end of file + s26-nomad | nomad-server | SYS-7049GP-TRT | C7470KH37A30505 | 10.30.51.26 | 10.30.50.26 | 3016.12 | u26-u29 + s36-t27-sut1 | 2n-grc | -- | -- | 10.30.51.36 | 10.30.50.36 | 3016.12 | u6 + s37-t27-tg1 | 2n-grc | ? | ? | 10.30.51.37 | 10.30.50.37 | 3016.12 | u2-u5
\ No newline at end of file diff --git a/fdio.infra/pxe/docker-dnsmasq/etc/dnsmasq.conf b/fdio.infra/pxe/docker-dnsmasq/etc/dnsmasq.conf index 2074dfd01c..6036b387d5 100755 --- a/fdio.infra/pxe/docker-dnsmasq/etc/dnsmasq.conf +++ b/fdio.infra/pxe/docker-dnsmasq/etc/dnsmasq.conf @@ -51,6 +51,8 @@ dhcp-host=3c:ec:ef:d9:dd:6b,10.30.51.32,s32-t31-sut1,infinite # eno2 dhcp-host=3c:ec:ef:d9:de:27,10.30.51.33,s33-t31-sut2,infinite # eno2 ICXD dhcp-host=3c:ec:ef:d9:dd:77,10.30.51.34,s34-t32-sut1,infinite # eno2 ICXD dhcp-host=3c:ec:ef:d9:dd:eb,10.30.51.35,s35-t32-sut2,infinite # eno2 ICXD +dhcp-host=ac:1f:6b:ac:d7:ba,10.30.51.36,s36-t27-sut1,infinite # eno1 GRC +dhcp-host=3c:ec:ef:b9:cc:44,10.30.51.37,s37-t27-tg1,infinite # eno1 ICX dhcp-host=40:8d:5c:e7:b2:6e,10.30.51.38,fdio-marvell-dev,infinite # enP2p1s0v0 ARM-DEV dhcp-host=ac:1f:6b:8a:8c:76,10.30.51.50,s50-nomad,infinite # eno1 HST dhcp-host=ac:1f:6b:8b:53:96,10.30.51.51,s51-nomad,infinite # eno1 HST |