aboutsummaryrefslogtreecommitdiffstats
path: root/docs/lab/testbed_specifications.md
diff options
context:
space:
mode:
authorMaciek Konstantynowicz <mkonstan@cisco.com>2019-02-27 21:27:04 +0000
committerMaciek Konstantynowicz <mkonstan@cisco.com>2019-03-06 14:35:38 +0000
commitddbfd9e68e81e77bd253c8b6cd81839ec3bd2715 (patch)
tree0f0216974f37b9b7953a4def38b9629bec8ebd7d /docs/lab/testbed_specifications.md
parenta1e7653789cf39773b717bb8dda0400d4683c96e (diff)
docs/lab: merged testbed specifications, separated out detailed HW and BIOS configs.
Change-Id: I5945723676361fdbe180a3bd5a6a366102ee6c67 Signed-off-by: Maciek Konstantynowicz <mkonstan@cisco.com>
Diffstat (limited to 'docs/lab/testbed_specifications.md')
-rw-r--r--docs/lab/testbed_specifications.md1469
1 files changed, 1469 insertions, 0 deletions
diff --git a/docs/lab/testbed_specifications.md b/docs/lab/testbed_specifications.md
new file mode 100644
index 0000000000..b12d42d22f
--- /dev/null
+++ b/docs/lab/testbed_specifications.md
@@ -0,0 +1,1469 @@
+<!-- TOC depthFrom:1 depthTo:6 withLinks:1 updateOnSave:1 orderedList:0 -->
+
+ - [FD.io CSIT Testbed Specifications](#fdio-csit-testbed-specifications)
+ - [Testbeds Overview](#testbeds-overview)
+ - [Summary List](#summary-list)
+ - [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
+ - [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
+ - [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
+ - [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
+ - [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
+ - [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx)
+ - [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
+ - [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
+ - [3-Node-MACCHIATObin Arm Marvell](#3-node-macchiatobin-arm-marvell)
+ - [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
+ - [Server Management](#server-management)
+ - [Requirements](#requirements)
+ - [Addressing](#addressing)
+ - [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
+ - [Management VLAN IP Addresses](#management-vlan-ip-addresses)
+ - [Server Type Specification](#server-type-specification)
+ - [Server and Port Naming](#server-and-port-naming)
+ - [Testbeds Configuration](#testbeds-configuration)
+ - [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
+ - [1-Node-Skylake (1n-skx) PROD](#1-node-skylake-1n-skx-prod)
+ - [1-Node-Thunderx2 (1n-tx2) WIP](#1-node-thunderx2-1n-tx2-wip)
+ - [2-Node-Skylake (2n-skx) PROD](#2-node-skylake-2n-skx-prod)
+ - [2-Node-Denverton (2n-dnv) TODO](#2-node-denverton-2n-dnv-todo)
+ - [2-Node-IxiaPS1L47 (2n-ps1) VERIFY](#2-node-ixiaps1l47-2n-ps1-verify)
+ - [3-Node-Haswell (3n-hsw) PROD](#3-node-haswell-3n-hsw-prod)
+ - [3-Node-Skylake (3n-skx) PROD](#3-node-skylake-3n-skx-prod)
+ - [3-Node-Rangeley (3n-rng) VERIFY](#3-node-rangeley-3n-rng-verify)
+ - [3-Node-Taishan (3n-tsh) WIP](#3-node-taishan-3n-tsh-wip)
+ - [3-Node-Mcbin (3n-mcb) TODO](#3-node-mcbin-3n-mcb-todo)
+ - [Per Testbed Wiring](#per-testbed-wiring)
+ - [1-Node-Skylake (1n-skx) PROD](#1-node-skylake-1n-skx-prod)
+ - [1-Node-Thunderx2 (1n-tx2) WIP](#1-node-thunderx2-1n-tx2-wip)
+ - [2-Node-Skylake (2n-skx) PROD](#2-node-skylake-2n-skx-prod)
+ - [2-Node-Denverton (2n-dnv) TODO](#2-node-denverton-2n-dnv-todo)
+ - [2-Node-IxiaPS1L47 (2n-ps1) VERIFY](#2-node-ixiaps1l47-2n-ps1-verify)
+ - [3-Node-Haswell (3n-hsw) PROD](#3-node-haswell-3n-hsw-prod)
+ - [3-Node-Skylake (3n-skx) PROD](#3-node-skylake-3n-skx-prod)
+ - [3-Node-Rangeley (3n-rng) TODO](#3-node-rangeley-3n-rng-todo)
+ - [3-Node-Taishan (3n-tsh) WIP](#3-node-taishan-3n-tsh-wip)
+ - [3-Node-Mcbin (3n-mcb) WIP](#3-node-mcbin-3n-mcb-wip)
+ - [Inventory](#inventory)
+ - [Appliances](#appliances)
+ - [Arm Servers](#arm-servers)
+ - [Xeon and Atom Servers](#xeon-and-atom-servers)
+ - [Network Interface Cards](#network-interface-cards)
+ - [Pluggables and Cables](#pluggables-and-cables)
+ - [Other Parts](#other-parts)
+
+<!-- /TOC -->
+## FD.io CSIT Testbed Specifications
+
+This note includes specification of the physical testbed infrastructure
+hosted by LFN FD.io CSIT project.
+
+## Testbeds Overview
+
+### Summary List
+
+```
+ #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #mcb
+ 1. 1-Node-Skylake func skx na 2 2 0 0 2 0 0 0 0 0 0
+ 2. 1-Node-Thunderx2 func tx2 na 1 1 0 0 0 0 0 0 1 0 0
+ 3. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0
+ 4. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0
+ 5. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0
+ 6. 3-Node-Haswell perf hsw hsw 3 6 3 9 0 0 0 0 0 0 0
+ 7. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0
+ 8. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0
+ 9. 3-Node-Taishan perf tsh skx 1 2 1 0 .5 0 0 0 0 2 0
+10. 3-Node-Mcbin perf mcb skx 1 2 1 0 .5 0 0 0 0 0 2
+11. 1-Node-VIRL func hsw --- 3 3 0 3 0 0 0 0 0 0 0
+ Totals: 17 26 14 12 19 1 2 1 1 2 2
+```
+
+### 1-Node-Skylake Xeon Intel (1n-skx)
+
+Each 1-Node-Skylake testbed includes one SUT (Type-B6 server) with NIC
+ports connected back-to-back.
+Used for FD.io VPP_Device functional driver tests.
+
+### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
+
+Each 1-Node-ThunderX2 testbed includes one SUT (Type-B9 server) with NIC
+ports connected back-to-back.
+Used for FD.io VPP_Device functional driver tests.
+
+### 2-Node-Skylake Xeon Intel (2n-skx)
+
+Each 2-Node-Skylake testbed includes one SUT (Type-B1 server) and one TG
+(Type-B2 server) connected back-to-back.
+Used for FD.io performance tests.
+
+### 2-Node-Denverton Atom Intel (2n-dnv)
+
+Each 2-Node-Skylake testbed includes one SUT (Type-B10 server) and one TG
+(Type-B2 server) connected back-to-back.
+Used for FD.io performance tests.
+
+### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
+
+Each 2-Node-IxiaPS1L47 testbed includes one SUT (Type-B1 server) and one
+TG (Ixia PSOne appliance) with 10GE interfaces connected back-to-back.
+Used for FD.io TCP/IP and HTTP performance tests.
+
+### 3-Node-Haswell Xeon Intel (3n-skx)
+
+### 3-Node-Skylake Xeon Intel (3n-skx)
+
+Each 3-Node-Skylake testbed includes two SUTs (Type-B1 servers) and one
+TG (Type-B2 server) connected in full-mesh triangle.
+Used for FD.io performance tests.
+
+### 3-Node-TaiShan Arm Huawei (3n-tsh)
+
+Each 3-Node-TaiShan testbed includes two SUTs (Type-B3 server) and one TG
+(Type-B2 server) connected in full-mesh triangle.
+Used for FD.io performance tests.
+
+### 3-Node-MACCHIATObin Arm Marvell
+
+Each 3-Node-MACCHIATObin testbed includes two SUTs (Type-B4 server) and
+one TG (Type-B2 server) connected in full-mesh triangle.
+Used for FD.io performance tests.
+
+### 3-Node-Rangeley Atom Testbeds
+
+Each 3-Node-Rangeley testbed includes two SUTs (Type-B5 Netgate device)
+and one TG (Type-2 server) connected in full-mesh triangle.
+Used for FD.io performance tests.
+
+## Server Management
+
+### Requirements
+
+For management purposes, each server must have following two ports
+connected to the management network:
+
+```
+- 1GE IPMI port
+ - IPMI - Intelligent Platform Management Interface.
+ - Required for access to embedded server management with WebUI, CLI, SNMPv3,
+ IPMIv2.0, for firmware (BIOS) and OS updates.
+- 1GE/10GE/40GE management port
+ - hostOS management port for general system management.
+```
+
+### Addressing
+
+Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a Management
+port, which are connected to two different VLANs.
+
+```
+1. LOM (IPMI) VLAN:
+ - Subnet: 10.30.50.0/24
+ - Gateway: 10.30.50.1
+ - Broadcast: 10.30.50.255
+ - DNS1: 199.204.44.24
+ - DNS2: 199.204.47.54
+2. Management Vlan:
+ - Subnet: 10.30.51.0/24
+ - Gateway: 10.30.51.1
+ - Broadcast: 10.30.51.255
+ - DNS1: 199.204.44.24
+ - DNS2: 199.204.47.54
+```
+
+To access these hosts, VPN connection is required.
+
+### LOM (IPMI) VLAN IP Addresses
+
+Name | Comment
+------------ | -------
+10.30.50.0 | network
+10.30.51.1 | Router
+10.30.50.2 | LF Reserved
+10.30.50.3 | LF Reserved
+10.30.50.4 | LF Reserved
+10.30.50.5 | LF Reserved
+10.30.50.6 | LF Reserved
+10.30.50.7 | LF Reserved
+10.30.50.8 | LF Reserved
+10.30.50.9 | LF Reserved
+10.30.50.10 | LF Reserved
+10.30.50.11 | LF Reserved
+10.30.50.12 | LF Reserved
+10.30.50.13 | LF Reserved
+10.30.50.14 | LF Reserved
+10.30.50.15 | LF Reserved
+10.30.50.16 | t1-tg1
+10.30.50.17 | t1-sut1
+10.30.50.18 | t1-sut2
+10.30.50.20 | t2-tg1
+10.30.50.21 | t2-sut1
+10.30.50.22 | t2-sut2
+10.30.50.24 | t3-tg1
+10.30.50.25 | t3-sut1
+10.30.50.26 | t3-sut-2
+10.30.50.28 | t4-sut1
+10.30.50.29 | t4-sut2
+10.30.50.30 | t4-sut3
+10.30.50.36 | s17-t33-sut1
+10.30.50.37 | s18-t33-sut2
+10.30.50.41 | s3-t21-sut1
+10.30.50.42 | s4-t21-tg1
+10.30.50.43 | s11-t31-sut1
+10.30.50.44 | s12-t31-sut2
+10.30.50.45 | s13-t31-tg1
+10.30.50.46 | s19-t33t34-tg1
+10.30.50.47 | s1-t11-sut1
+10.30.50.48 | s2-t12-sut1
+10.30.50.49 | s5-t22-sut1
+10.30.50.50 | s6-t22-tg1
+10.30.50.51 | s7-t23-sut1
+10.30.50.52 | s8-t23-tg1
+10.30.50.53 | s9-t24-sut1
+10.30.50.54 | s10-t24-tg1
+10.30.50.55 | s14-t32-sut1
+10.30.50.56 | s15-t32-sut2
+10.30.50.57 | s16-t32-tg1
+10.30.50.58 | s25-t25-sut1
+10.30.50.59 | s26-t25-tg1
+10.30.50.69 | s27-t13-sut
+10.30.50.255 | Broadcast
+
+### Management VLAN IP Addresses
+
+Name | Comment
+------------------------- | -------
+10.30.51.0 | network
+10.30.51.1 | Router
+10.30.51.2 | LF Reserved
+10.30.51.3 | LF Reserved
+10.30.51.4 | LF Reserved
+10.30.51.5 | LF Reserved
+10.30.51.6 | LF Reserved
+10.30.51.7 | LF Reserved
+10.30.51.8 | LF Reserved
+10.30.51.9 | s22-t35-sut1 (netgate-1)
+10.30.51.10 | s23-t35-sut2 (netgate-2)
+10.30.51.11 | s24-t35-sut3 (netgate-3)
+10.30.51.12 | softiron-1
+10.30.51.13 | softiron-2
+10.30.51.14 | softiron-3
+10.30.51.15 | LF Reserved
+10.30.51.16 | t1-tg1
+10.30.51.17 | t1-sut1
+10.30.51.18 | t1-sut2
+10.30.51.20 | t2-tg1
+10.30.51.21 | t2-sut1
+10.30.51.22 | t2-sut2
+10.30.51.24 | t3-tg1
+10.30.51.25 | t3-sut1
+10.30.51.26 | t3-sut-2
+10.30.51.28 | t4-sut1
+10.30.51.29 | t4-sut2
+10.30.51.29 | s22-t35-sut1 screen -r /dev/ttyUSB0, TO BE VERIFIED
+10.30.51.30 | t4-sut3
+10.30.51.30 | s23-t35-sut2 screen -r /dev/ttyUSB1, TO BE VERIFIED
+10.30.51.30 | s24-t35-sut3 screen -r /dev/ttyUSB2, TO BE VERIFIED
+10.30.51.36 | s17-t33-sut1
+10.30.51.37 | s18-t33-sut2
+10.30.51.41 | s20-t34-sut1
+10.30.51.42 | s21-t34-sut2
+10.30.51.44 | s3-t21-sut1
+10.30.51.45 | s4-t21-tg1
+10.30.51.46 | s11-t31-sut1
+10.30.51.47 | s12-t31-sut2
+10.30.51.48 | s13-t31-tg1
+10.30.51.49 | s19-t33t34-tg1
+10.30.51.50 | s1-t11-sut1
+10.30.51.51 | s2-t12-sut1
+10.30.51.52 | s5-t22-sut1
+10.30.51.53 | s6-t22-tg1
+10.30.51.54 | s7-t23-sut1
+10.30.51.55 | s8-t23-tg1
+10.30.51.56 | s9-t24-sut1
+10.30.51.57 | s10-t24-tg1
+10.30.51.58 | s14-t32-sut1
+10.30.51.59 | s15-t32-sut2
+10.30.51.60 | s16-t32-tg1
+10.30.51.61 | s25-t25-sut1
+10.30.51.62 | s26-t25-tg1
+10.30.51.69 | s27-t13-sut1
+10.30.51.70-10.30.51.105 | VIRL1 TO BE VERIFIED
+10.30.51.106-10.30.51.180 | VIRL2
+10.30.51.181-10.30.51.254 | VIRL3
+10.30.51.255 | Broadcast
+
+## Server Type Specification
+
+FD.io CSIT lab contains following server types:
+```
+1. Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
+ - Quantity: 6 servers.
+ - Physical connectivity:
+ - CIMC and host management ports.
+ - NIC ports connected in 3-node topologies.
+ - Main HW configuration:
+ - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
+ - Processors: 2* E5-2699v3 2.3 GHz.
+ - RAM Memory: 16* 32GB DDR4-2133MHz.
+ - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
+ - NICs configuration:
+ - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
+ - PCIe Slot1: Cisco VIC 1385 2p40GE.
+ - PCIe Slot2: Intel NIC x520 2p10GE.
+ - PCIe Slot3: empty.
+ - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
+ - PCIe Slot4: Intel NIC xl710 2p40GE.
+ - PCIe Slot5: Intel NIC x710 2p10GE.
+ - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill)
+ - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
+2. Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
+ - Quantity: 3 servers.
+ - Physical connectivity:
+ - CIMC and host management ports.
+ - NIC ports connected in 3-node topologies.
+ - Main HW configuration:
+ - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
+ - Processors: 2* E5-2699v3 2.3 GHz.
+ - RAM Memory: 16* 32GB DDR4-2133MHz.
+ - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
+ - NICs configuration:
+ - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
+ - PCIe Slot1: Intel NIC xl710 2p40GE.
+ - PCIe Slot2: Intel NIC x710 2p10GE.
+ - PCIe Slot3: Intel NIC x710 2p10GE.
+ - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
+ - PCIe Slot4: Intel NIC xl710 2p40GE.
+ - PCIe Slot5: Intel NIC x710 2p10GE.
+ - PCIe Slot6: Intel NIC x710 2p10GE.
+ - MLOM slot: empty.
+3. Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
+ - Quantity: 3 servers.
+ - Physical connectivity:
+ - CIMC and host management ports.
+ - no NIC ports, standalone setup.
+ - Main HW configuration:
+ - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
+ - Processors: 2* E5-2699v3 2.3 GHz.
+ - RAM Memory: 16* 32GB DDR4-2133MHz.
+ - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
+ - NICs configuration:
+ - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
+ - no cards.
+ - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
+ - no cards.
+ - MLOM slot: empty.
+4. Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
+ - Quantity: ---
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 2-node and 3-node topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-7049GP-TRT.
+ - Motherboard: SuperMicro X11DPG-QT.
+ - Processors: 2* Intel Platinum 8180 2.3 GHz.
+ - RAM Memory: 16* 16GB DDR4-2666MHz.
+ - Disks: 2* 1.6TB 6G SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
+ - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
+ - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox.
+ - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot6 86:00.xx: empty.
+ - PCIe Slot8 af:00.xx: empty.
+ - PCIe Slot10 d8:00.xx: empty.
+2. Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
+ - Quantity: ---
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 2-node and 3-node topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-7049GP-TRT.
+ - Motherboard: SuperMicro X11DPG-QT.
+ - Processors: 2* Intel Platinum 8180 2.3 GHz.
+ - RAM Memory: 16* 16GB DDR4-2666MHz.
+ - Disks: 2* 1.6TB 6G SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
+ - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
+ - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox.
+ - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot6 86:00.xx: empty.
+ - PCIe Slot8 af:00.xx: empty.
+ - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
+3. Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
+ - Quantity: 2
+ - Physical connectivity:
+ - IPMI(?) and host management ports.
+ - NIC ports connected into 3-node topology.
+ - Main HW configuration:
+ - Chassis: Huawei TaiShan 2280.
+ - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72
+ - RAM Memory: 8* 16GB DDR4-2400MT/s
+ - Disks: 1* 4TB SATA HDD
+ - NICs configuration:
+ - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
+ - PCIe Slot6 11:00.xx: 82599-2p10GE Intel.
+4. Type-B4: Purpose - MACCHIATObin Arm Marvell SUT for FD.io performance testing.
+ - Quantity: 3
+ - Physical connectivity:
+ - Host management ports.
+ - NIC ports connected into 2-node and 3-node topologies.
+ - Main HW configuration:
+ - Chassis: MACCHIATObin.
+ - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72
+ - RAM Memory: 1* 16GB DDR4
+ - Disks: 1* 128GB(?) SATA SDD
+ - NICs configuration:
+ - pp2-2p10GE Marvell (on-chip Ethernet ports ; marvell plugin in VPP)
+5. Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
+ - Quantity: TBD based on testbed allocation.
+ - Physical connectivity:
+ - Management: serial Port (usb) for console
+ - NIC ports connected into 2-node.
+ - Main HW configuration:
+ - Chassis: Netgate XG-2758-1u
+ - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
+ - RAM Memory: 16GB ECC
+ - Disks: 150 GB
+ - NICs configuration:
+ - 2x 10Gb Intel 82599ES
+ - 4x 1GB Intel I354
+6. Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
+ - Quantity: 2.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 2-node and 3-node topologies.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-7049GP-TRT.
+ - Motherboard: SuperMicro X11DPG-QT.
+ - Processors: 2* Intel Platinum 8180 2.3 GHz.
+ - RAM Memory: 16* 16GB DDR4-2666MHz.
+ - Disks: 2* 1.6TB 6G SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
+ - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
+ - PCIe Slot9 5e:00.xx: empty.
+ - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot6 86:00.xx: empty.
+ - PCIe Slot8 af:00.xx: empty.
+ - PCIe Slot10 d8:00.xx: empty.
+7. Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
+ - Quantity: 1.
+ - Physical connectivity:
+ - Host management interface: 10/100/1000-BaseT.
+ - 8-port 10GE SFP+ integrated NIC.
+ - Main HW configuration:
+ - Chassis: PS10GE4NG.
+ - Motherboard: SuperMicro X11DPG-QT.
+ - Processors: Quad-Core, Intel Processor.
+ - HW accelerators: FPGA offload.
+ - RAM Memory: 64GB.
+ - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
+ - Physical Interfaces: 4 * 10GE SFP+.
+ - Operating System: Native IxOS.
+ - Interface configuration:
+ - Port-1: 10GE SFP+.
+ - Port-2: 10GE SFP+.
+ - Port-3: 10GE SFP+.
+ - Port-4: 10GE SFP+.
+8. Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
+ - Quantity: 1.
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-7049GP-TRT.
+ - Motherboard: SuperMicro X11DPG-QT.
+ - Processors: 2* Intel Platinum 8180 2.3 GHz.
+ - RAM Memory: 16* 16GB DDR4-2666MHz.
+ - Disks: 2* 1.6TB 6G SATA SSD.
+ - NICs configuration:
+ - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
+ - PCIe Slot4 3b:00.xx: empty.
+ - PCIe Slot9 5e:00.xx: empty.
+ - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+ - PCIe Slot6 86:00.xx: empty.
+ - PCIe Slot8 af:00.xx: empty.
+ - PCIe Slot10 d8:00.xx: empty.
+9. Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
+ - Quantity: 1
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports connected into 1-node topologies.
+ - Main HW configuration:
+ - Chassis: Gigabyte R181-T90 1U
+ - Motheboard: MT91-FS1
+ - Processors: 1* ThunderX2 ARMv8 CN9975 2.0 GHz
+ - RAM Memory: 4* 32GB RDIMM
+ - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
+ - NICs configuration:
+ - Numa0:
+ - PCIe Slot1 05:00.xx: XL710-QDA2.
+ - PCIe Slot3 08:00.xx: XL710-QDA2.
+ - Numa1:
+ - PCIe Slot6 85:00.xx: XL710-QDA2.
+10. Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
+ - Quantity: 4
+ - Physical connectivity:
+ - IPMI and host management ports.
+ - NIC ports.
+ - Main HW configuration:
+ - Chassis: SuperMicro SYS-E300-9A
+ - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
+ - RAM Memory: 32GB ECC
+ - Disks: 480 GB
+ - NICs configuration:
+ - 2x 10Gb Intel x553 fiber ports
+ - 2x 10Gb Intel x553 copper ports
+ - 4x 1GB Intel I350 ports
+```
+
+### Server and Port Naming
+
+Following naming convention is used within this page to specify physical
+connectivity and wiring across defined CSIT testbeds:
+
+```
+- testbedname: testbedN.
+- hostname:
+ - traffic-generator: tN-tgW.
+ - system-under-testX: tN-sutX.
+- portnames:
+ - tN-tgW-cY/pZ.
+ - tN-sutX-cY/pZ.
+- where:
+ - N - testbed number.
+ - tgW - server acts as traffic-generator with W index.
+ - sutX - server acts as system-under-test with X index.
+ - Y - PCIe slot number denoting a NIC card number within the host.
+ - Z - port number on the NIC card.
+```
+
+## Testbeds Configuration
+
+### Per Testbed Server Allocation and Naming
+
+#### 1-Node-Skylake (1n-skx) PROD
+
+```
+- ServerB1 [Type-B6]:
+ - testbedname: testbed11.
+ - hostname: s1-t11-sut1.
+ - IPMI IP: 10.30.50.47
+ - Host IP: 10.30.51.50
+ - portnames:
+ - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
+ - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
+ - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
+ - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
+- ServerB2 [Type-B6]:
+ - testbedname: testbed12.
+ - hostname: s2-t12-sut1.
+ - IPMI IP: 10.30.50.48
+ - Host IP: 10.30.51.51
+ - portnames:
+ - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
+ - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
+ - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
+ - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
+```
+
+#### 1-Node-Thunderx2 (1n-tx2) WIP
+
+```
+- ServerB17 [Type-B9]:
+ - testbedname: testbed13.
+ - hostname: s27-t13-sut1.
+ - IPMI IP: 10.30.50.69
+ - Host IP: 10.30.51.69
+ - portnames:
+ - s27-t13-sut1-c1/p1 - 40GE-port1 XL710-QDA2-2p40GE.
+ - s27-t13-sut1-c1/p2 - 40GE-port2 XL710-QDA2-2p40GE.
+ - s27-t13-sut1-c3/p1 - 40GE-port1 XL710-QDA2-2p40GE.
+ - s27-t13-sut1-c3/p2 - 40GE-port2 XL710-QDA2-2p40GE.
+ - s27-t13-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
+ - s27-t13-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE.
+```
+
+#### 2-Node-Skylake (2n-skx) PROD
+
+```
+- ServerB3 [Type-B1]:
+ - testbedname: testbed21.
+ - hostname: s3-t21-sut1.
+ - IPMI IP: 10.30.50.41
+ - Host IP: 10.30.51.44
+ - portnames:
+ - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s3-t21-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
+ - s3-t21-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+- ServerB4 [Type-B2]:
+ - testbedname: testbed21.
+ - hostname: s4-t21-tg1.
+ - IPMI IP: 10.30.50.42
+ - Host IP: 10.30.51.45
+ - portnames:
+ - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s4-t21-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
+ - s4-t21-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+- ServerB5 [Type-B1]:
+ - testbedname: testbed22.
+ - hostname: s5-t22-sut1.
+ - IPMI IP: 10.30.50.49
+ - Host IP: 10.30.51.52
+ - portnames:
+ - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s5-t22-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
+ - s5-t22-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+- ServerB6 [Type-B2]:
+ - testbedname: testbed22.
+ - hostname: s6-t22-tg1.
+ - IPMI IP: 10.30.50.50
+ - Host IP: 10.30.51.53
+ - portnames:
+ - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s6-t22-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
+ - s6-t22-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+- ServerB7 [Type-B1]:
+ - testbedname: testbed23.
+ - hostname: s7-t23-sut1.
+ - IPMI IP: 10.30.50.51
+ - Host IP: 10.30.51.54
+ - portnames:
+ - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s7-t23-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
+ - s7-t23-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+- ServerB8 [Type-B2]:
+ - testbedname: testbed23.
+ - hostname: s8-t23-tg1.
+ - IPMI IP: 10.30.50.52
+ - Host IP: 10.30.51.55
+ - portnames:
+ - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s8-t23-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
+ - s8-t23-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+- ServerB9 [Type-B1]:
+ - testbedname: testbed24.
+ - hostname: s9-t24-sut1.
+ - IPMI IP: 10.30.50.53
+ - Host IP: 10.30.51.56
+ - portnames:
+ - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s9-t24-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
+ - s9-t24-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+- ServerB10 [Type-B2]:
+ - testbedname: testbed24.
+ - hostname: s10-t24-tg1.
+ - IPMI IP: 10.30.50.54
+ - Host IP: 10.30.51.57
+ - portnames:
+ - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s10-t24-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
+ - s10-t24-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+```
+
+#### 2-Node-Denverton (2n-dnv) TODO
+
+```
+To be completed.
+```
+
+#### 2-Node-IxiaPS1L47 (2n-ps1) VERIFY
+
+```
+- ServerB25 [Type-B8]:
+ - testbedname: testbed25.
+ - hostname: s25-t25-sut1.
+ - IPMI IP: 10.30.50.58
+ - Host IP: 10.30.51.61
+ - portnames:
+ - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
+- ServerB26 [Type-B7]:
+ - testbedname: testbed25.
+ - hostname: s26-t25-tg1.
+ - IPMI IP: 10.30.50.59
+ - Host IP: 10.30.51.62
+ - portnames:
+ - s26-t25-tg1-p1 - 10GE-port1.
+ - s26-t25-tg1-p2 - 10GE-port2.
+ - s26-t25-tg1-p3 - 10GE-port3.
+ - s26-t25-tg1-p4 - 10GE-port4.
+```
+
+#### 3-Node-Haswell (3n-hsw) PROD
+
+```
+ 1. Server1 of Type-1:
+ - testbedname: testbed1.
+ - hostname: t1-sut1.
+ - CIMC IP: 10.30.50.17
+ - Host IP: 10.30.51.17
+ - portnames:
+ - t1-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
+ - t1-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
+ - t1-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
+ - t1-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
+ - t1-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
+ - t1-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
+ - t1-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
+ - t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
+ - t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
+ - t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
+ 2. Server2 of Type-1:
+ - testbedname: testbed1.
+ - hostname: t1-sut2.
+ - CIMC IP: 10.30.50.18
+ - Host IP: 10.30.51.18
+ - portnames:
+ - t1-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
+ - t1-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
+ - t1-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
+ - t1-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
+ - t1-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
+ - t1-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
+ - t1-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
+ - t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
+ - t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
+ - t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
+ 3. Server3 of Type-2:
+ - testbedname: testbed1.
+ - hostname: t1-tg1.
+ - CIMC IP: 10.30.50.16
+ - Host IP: 10.30.51.16
+ - portnames:
+ - t1-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
+ - t1-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
+ - t1-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
+ - t1-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
+ - t1-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
+ - t1-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
+ - t1-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
+ - t1-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
+ - t1-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
+ - t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
+ - t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
+ - t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
+ 4. Server4 of Type-1:
+ - testbedname: testbed2.
+ - hostname: t2-sut1.
+ - CIMC IP: 10.30.50.21
+ - Host IP: 10.30.51.21
+ - portnames:
+ - t2-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
+ - t2-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
+ - t2-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
+ - t2-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
+ - t2-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
+ - t2-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
+ - t2-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
+ - t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
+ - t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
+ - t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
+ 5. Server5 of Type-1:
+ - testbedname: testbed2.
+ - hostname: t2-sut2.
+ - CIMC IP: 10.30.50.22
+ - Host IP: 10.30.51.22
+ - portnames:
+ - t2-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
+ - t2-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
+ - t2-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
+ - t2-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
+ - t2-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
+ - t2-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
+ - t2-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
+ - t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
+ - t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
+ - t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
+ 6. Server6 of Type-2:
+ - testbedname: testbed2.
+ - hostname: t2-tg1.
+ - CIMC IP: 10.30.50.20
+ - Host IP: 10.30.51.20
+ - portnames:
+ - t2-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
+ - t2-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
+ - t2-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
+ - t2-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
+ - t2-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
+ - t2-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
+ - t2-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
+ - t2-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
+ - t2-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
+ - t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
+ - t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
+ - t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
+ 7. Server7 of Type-1:
+ - testbedname: testbed3.
+ - hostname: t3-sut1.
+ - CIMC IP: 10.30.50.25
+ - Host IP: 10.30.51.25
+ - portnames:
+ - t3-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
+ - t3-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
+ - t3-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
+ - t3-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
+ - t3-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
+ - t3-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
+ - t3-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
+ - t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
+ - t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
+ - t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
+ 8. Server8 of Type-1:
+ - testbedname: testbed3.
+ - hostname: t3-sut2.
+ - CIMC IP: 10.30.50.26
+ - Host IP: 10.30.51.26
+ - portnames:
+ - t3-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
+ - t3-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
+ - t3-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
+ - t3-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
+ - t3-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
+ - t3-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
+ - t3-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
+ - t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
+ - t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
+ - t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
+ 9. Server9 of Type-2:
+ - testbedname: testbed3.
+ - hostname: t3-tg1.
+ - CIMC IP: 10.30.50.24
+ - Host IP: 10.30.51.24
+ - portnames:
+ - t3-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
+ - t3-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
+ - t3-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
+ - t3-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
+ - t3-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
+ - t3-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
+ - t3-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
+ - t3-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
+ - t3-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
+ - t3-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
+ - t3-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
+ - t3-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
+```
+
+#### 3-Node-Skylake (3n-skx) PROD
+
+```
+- ServerB11 [Type-B1]:
+ - testbedname: testbed31.
+ - hostname: s11-t31-sut1.
+ - IPMI IP: 10.30.50.43
+ - Host IP: 10.30.51.46
+ - portnames:
+ - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
+ - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+- ServerB12 [Type-B1]:
+ - testbedname: testbed31.
+ - hostname: s12-t31-sut2.
+ - IPMI IP: 10.30.50.44
+ - Host IP: 10.30.51.47
+ - portnames:
+ - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
+ - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+- ServerB13 [Type-B2]:
+ - testbedname: testbed31.
+ - hostname: s13-t31-tg1.
+ - IPMI IP: 10.30.50.45
+ - Host IP: 10.30.51.48
+ - portnames:
+ - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
+ - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+- ServerB14 [Type-B1]:
+ - testbedname: testbed32.
+ - hostname: s14-t32-sut1.
+ - IPMI IP: 10.30.50.55
+ - Host IP: 10.30.51.58
+ - portnames:
+ - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
+ - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+- ServerB15 [Type-B1]:
+ - testbedname: testbed32.
+ - hostname: s15-t32-sut2.
+ - IPMI IP: 10.30.50.56
+ - Host IP: 10.30.51.59
+ - portnames:
+ - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
+ - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+- ServerB16 [Type-B2]:
+ - testbedname: testbed32.
+ - hostname: s16-t32-tg1.
+ - IPMI IP: 10.30.50.57
+ - Host IP: 10.30.51.60
+ - portnames:
+ - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
+ - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+```
+
+Note: ServerB19 (TG) is shared between testbed33 & testbed34
+
+#### 3-Node-Rangeley (3n-rng) VERIFY
+
+Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
+
+```
+- ServerB22 [Type-B5]:
+ - testbedname: testbed35.
+ - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
+ - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
+ - Host IP: 10.30.51.9
+ - portnames:
+ - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
+ - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
+ - 1GB ports (tbd)
+- ServerB23 [Type-B5]:
+ - testbedname: testbed35.
+ - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
+ - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
+ - Host IP: 10.30.51.10
+ - portnames:
+ - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
+ - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
+ - 1GB ports (tbd)
+- ServerB24 [Type-B5]:
+ - testbedname: testbed35.
+ - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
+ - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
+ - Host IP: 10.30.51.11
+ - portnames:
+ - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
+ - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
+ - 1GB ports (tbd)
+```
+
+#### 3-Node-Taishan (3n-tsh) WIP
+
+```
+- ServerB17 [Type-B3]:
+ - testbedname: testbed33.
+ - hostname: s17-t33-sut1.
+ - IPMI IP: 10.30.50.36
+ - Host IP: 10.30.51.36
+ - portnames:
+ - s17-t33-sut1-c6/p1 - 10GE-port1 82599-2p10GE.
+ - s17-t33-sut1-c6/p2 - 10GE-port2 82599-2p10GE.
+ - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
+ - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
+- ServerB18 [Type-B3]:
+ - testbedname: testbed33.
+ - hostname: s18-t33-sut2.
+ - IPMI IP: 10.30.50.37
+ - Host IP: 10.30.51.37
+ - portnames:
+ - s18-t33-sut2-c6/p1 - 10GE-port1 82599-2p10GE.
+ - s18-t33-sut2-c6/p2 - 10GE-port2 82599-2p10GE.
+ - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
+ - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
+- ServerB19 [Type-B2]:
+ - testbednames: testbed33 and testbed34.
+ - hostname: s19-t33t34-tg1.
+ - IPMI IP: 10.30.50.46
+ - Host IP: 10.30.51.49
+ - portnames:
+ - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+ - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+ - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+ - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+ - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+ - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+ - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
+ - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
+ - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
+ - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
+- ServerB20 [Type-B4]:
+ - testbedname: testbed34.
+ - hostname: s20-t34-sut1.
+ - IPMI IP: N/A
+ - Host IP: 10.30.51.41
+ - portnames:
+ - s20-t34-sut1-ca/p1 - 10GE-port1 Marvell.
+ - s20-t34-sut1-ca/p2 - 10GE-port2 Marvell.
+- ServerB21 [Type-B4]:
+ - testbedname: testbed34.
+ - hostname: s21-t34-sut2.
+ - IPMI IP: N/A
+ - Host IP: 10.30.51.42
+ - portnames:
+ - s21-t34-sut2-ca/p1 - 10GE-port1 Marvell.
+ - s21-t34-sut2-ca/p2 - 10GE-port2 Marvell.
+```
+
+#### 3-Node-Mcbin (3n-mcb) TODO
+
+```
+To be completed.
+```
+
+### Per Testbed Wiring
+
+#### 1-Node-Skylake (1n-skx) PROD
+
+```
+- testbed11:
+ - ring1 10GE-ports x710-4p10GE:
+ - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
+ - ring2 10GE-ports x710-4p10GE:
+ - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
+ - ring3 10GE-ports x710-4p10GE:
+ - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
+ - ring4 10GE-ports x710-4p10GE:
+ - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
+- testbed12:
+ - ring1 10GE-ports x710-4p10GE:
+ - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
+ - ring2 10GE-ports x710-4p10GE:
+ - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
+ - ring3 10GE-ports x710-4p10GE:
+ - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
+ - ring4 10GE-ports x710-4p10GE:
+ - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
+```
+
+#### 1-Node-Thunderx2 (1n-tx2) WIP
+
+```
+- testbed13:
+ - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
+ - s27-t13-sut1-c1/p2 - s27-t13-sut1-c3/p1.
+ - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
+ - s27-t13-sut1-c3/p2 - s27-t13-sut1-c6/p1.
+ - ring3 40GE-ports XL710-QDA2-2p40GE on SUTs:
+ - s27-t13-sut1-c6/p2 - s27-t13-sut1-c1/p1.
+```
+
+#### 2-Node-Skylake (2n-skx) PROD
+
+```
+- testbed21:
+ - ring1 10GE-ports x710-4p10GE on SUT:
+ - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
+ - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
+ - ring2 10GE-ports x710-4p10GE on SUT:
+ - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
+ - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
+ - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
+ - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
+ - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
+ - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
+ - s4-t21-tg1-c9/p1 to s3-t21-sut1-c9/p1.
+ - s3-t21-sut1-c9/p2 to s4-t21-tg1-c9/p2.
+ - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
+ - s4-t21-tg1-c10/p1 to s4-t21-tg1-c10/p2.
+ - s4-t21-tg1-c10/p3 to s4-t21-tg1-c10/p4.
+- testbed22:
+ - ring1 10GE-ports x710-4p10GE on SUT:
+ - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
+ - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
+ - ring2 10GE-ports x710-4p10GE on SUT:
+ - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
+ - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
+ - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
+ - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
+ - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
+ - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
+ - t22-tg1-c9/p1 to s5-t22-sut1-c9/p1.
+ - s5-t22-sut1-c9/p2 to s6-t22-tg1-c9/p2.
+ - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
+ - s6-t22-tg1-c10/p1 to s6-t22-tg1-c10/p2.
+ - s6-t22-tg1-c10/p3 to s6-t22-tg1-c10/p4.
+- testbed23:
+ - ring1 10GE-ports x710-4p10GE on SUT:
+ - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
+ - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
+ - ring2 10GE-ports x710-4p10GE on SUT:
+ - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
+ - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
+ - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
+ - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
+ - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
+ - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
+ - s8-t23-tg1-c9/p1 to s7-t23-sut1-c9/p1.
+ - s7-t23-sut1-c9/p2 to s8-t23-tg1-c9/p2.
+ - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
+ - s8-t23-tg1-c10/p1 to s8-t23-tg1-c10/p2.
+ - s8-t23-tg1-c10/p3 to s8-t23-tg1-c10/p4.
+- testbed24:
+ - ring1 10GE-ports x710-4p10GE on SUT:
+ - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
+ - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
+ - ring2 10GE-ports x710-4p10GE on SUT:
+ - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
+ - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
+ - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
+ - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
+ - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
+ - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
+ - s10-t24-tg1-c9/p1 to s9-t24-sut1-c9/p1.
+ - s9-t24-sut1-c9/p2 to s10-t24-tg1-c9/p2.
+ - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
+ - s10-t24-tg1-c10/p1 to s10-t24-tg1-c10/p2.
+ - s10-t24-tg1-c10/p3 to s10-t24-tg1-c10/p4.
+```
+
+#### 2-Node-Denverton (2n-dnv) TODO
+
+```
+To be completed.
+```
+
+#### 2-Node-IxiaPS1L47 (2n-ps1) VERIFY
+
+```
+- testbed25:
+ - link1 10GE-port x710-4p10GE on SUT:
+ - t25-tg1-p1 to t25-sut1-c2/p1.
+ - link2 10GE-port x710-4p10GE on SUT:
+ - t25-tg1-p2 to t25-sut1-c2/p2.
+ - link3 10GE-port x710-4p10GE on SUT:
+ - t25-tg1-p3 to t25-sut1-c2/p3.
+ - link4 10GE-port x710-4p10GE on SUT:
+ - t25-tg1-p4 to t25-sut1-c2/p4.
+```
+
+#### 3-Node-Haswell (3n-hsw) PROD
+
+```
+ 1. testbed1:
+ - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
+ - t1-tg1-c1/p1 to t1-sut1-c1/p2.
+ - t1-sut1-c1/p1 to t1-sut2-c1/p2.
+ - t1-sut2-c1/p1 to t1-tg1-c1/p2.
+ - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
+ - t1-tg1-c2/p1 to t1-sut1-c2/p2.
+ - t1-sut1-c2/p1 to t1-sut2-c2/p2.
+ - t1-sut2-c2/p1 to t1-tg1-c2/p2.
+ - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
+ - t1-tg1-c4/p1 to t1-sut1-c4/p2.
+ - t1-sut1-c4/p1 to t1-sut2-c4/p2.
+ - t1-sut2-c4/p1 to t1-tg1-c4/p2.
+ - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
+ - t1-tg1-c5/p1 to t1-sut1-c5/p2.
+ - t1-sut1-c5/p1 to t1-sut2-c5/p2.
+ - t1-sut2-c5/p1 to t1-tg1-c5/p2.
+ - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
+ - t1-tg1-c2/p1 to t1-sut1-cm/p2.
+ - t1-sut1-cm/p1 to t1-sut2-cm/p2.
+ - t1-sut2-cm/p1 to t1-tg1-c2/p2.
+ - TG loopback ports Intel NIC x710 2p10GE
+ - t1-tg1-c6/p1 to t1-tg1-c6/p2.
+
+ 2. testbed2:
+ - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
+ - t2-tg1-c1/p1 to t2-sut1-c1/p2.
+ - t2-sut1-c1/p1 to t2-sut2-c1/p2.
+ - t2-sut2-c1/p1 to t2-tg1-c1/p2.
+ - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
+ - t2-tg1-c2/p1 to t2-sut1-c2/p2.
+ - t2-sut1-c2/p1 to t2-sut2-c2/p2.
+ - t2-sut2-c2/p1 to t2-tg1-c2/p2.
+ - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
+ - t2-tg1-c4/p1 to t2-sut1-c4/p2.
+ - t2-sut1-c4/p1 to t2-sut2-c4/p2.
+ - t2-sut2-c4/p1 to t2-tg1-c4/p2.
+ - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
+ - t2-tg1-c5/p1 to t2-sut1-c5/p2.
+ - t2-sut1-c5/p1 to t2-sut2-c5/p2.
+ - t2-sut2-c5/p1 to t2-tg1-c5/p2.
+ - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
+ - t2-tg1-c2/p1 to t2-sut1-cm/p2.
+ - t2-sut1-cm/p1 to t2-sut2-cm/p2.
+ - t2-sut2-cm/p1 to t2-tg1-c2/p2.
+ - TG loopback ports Intel NIC x710 2p10GE
+ - t2-tg1-c6/p1 to t2-tg1-c6/p2.
+
+ 3. testbed3:
+ - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
+ - t3-tg1-c1/p1 to t3-sut1-c1/p2.
+ - t3-sut1-c1/p1 to t3-sut2-c1/p2.
+ - t3-sut2-c1/p1 to t3-tg1-c1/p2.
+ - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
+ - t3-tg1-c2/p1 to t3-sut1-c2/p2.
+ - t3-sut1-c2/p1 to t3-sut2-c2/p2.
+ - t3-sut2-c2/p1 to t3-tg1-c2/p2.
+ - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
+ - t3-tg1-c4/p1 to t3-sut1-c4/p2.
+ - t3-sut1-c4/p1 to t3-sut2-c4/p2.
+ - t3-sut2-c4/p1 to t3-tg1-c4/p2.
+ - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
+ - t3-tg1-c5/p1 to t3-sut1-c5/p2.
+ - t3-sut1-c5/p1 to t3-sut2-c5/p2.
+ - t3-sut2-c5/p1 to t3-tg1-c5/p2.
+ - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
+ - t3-tg1-c2/p1 to t3-sut1-cm/p2.
+ - t3-sut1-cm/p1 to t3-sut2-cm/p2.
+ - t3-sut2-cm/p1 to t3-tg1-c2/p2.
+ - TG loopback ports Intel NIC x710 2p10GE
+ - t3-tg1-c6/p1 to t3-tg1-c6/p2.
+```
+
+#### 3-Node-Skylake (3n-skx) PROD
+
+```
+- testbed31:
+ - ring1 10GE-ports x710-4p10GE on SUTs:
+ - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
+ - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
+ - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
+ - ring2 10GE-ports x710-4p10GE on SUT:
+ - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
+ - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
+ - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
+ - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
+ - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
+ - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
+ - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
+ - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
+ - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
+ - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
+ - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
+ - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
+ - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
+ - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
+- testbed32:
+ - ring1 10GE-ports x710-4p10GE on SUTs:
+ - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
+ - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
+ - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
+ - ring2 10GE-ports x710-4p10GE on SUT:
+ - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
+ - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
+ - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
+ - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
+ - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
+ - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
+ - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
+ - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
+ - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
+ - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
+ - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
+ - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
+ - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
+ - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
+```
+
+#### 3-Node-Rangeley (3n-rng) TODO
+
+```
+To be completed.
+```
+
+#### 3-Node-Taishan (3n-tsh) WIP
+
+```
+- testbed33:
+ - ring1 10GE-ports 82599-2p10GE on SUTs:
+ - t33t34-tg1-c2/p2 - t33-sut1-c6/p2.
+ - t33-sut1-c6/p1 - t33-sut2-c6/p2.
+ - t33-sut2-c6/p1 - t33t34-tg1-c2/p1.
+ - ring2 25GE-ports cx4-2p25GE on SUTs:
+ - t33t34-tg1-c4/p2 - t33-sut1-c4/p2.
+ - t33-sut1-c4/p1 - t33-sut2-c4/p2.
+ - t33-sut2-c4/p1 - t33t34-tg1-c4/p1.
+```
+
+#### 3-Node-Mcbin (3n-mcb) WIP
+
+```
+- testbed34:
+ - ring1 10GE-ports Marvell on SUTs:
+ - t33t34-tg1-c2/p3 - t34-sut1-ca/p1.
+ - t34-sut1-ca/p2 - t34-sut2-ca/p1.
+ - t34-sut2-ca/p2 - t33t34-tg1-c2/p4.
+```
+
+## Inventory
+
+### Appliances
+
+```
+1. Ixia PerfectStorm One Appliance
+ - 1 * PS10GE4NG
+ - Chassis: PS10GE4NG.
+ - Motherboard: SuperMicro X11DPG-QT.
+ - Processors: Quad-Core, Intel Processor.
+ - HW accelerators: FPGA offload.
+ - RAM Memory: 64GB.
+ - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
+ - Physical Interfaces: 4 * 10GE SFP+.
+ - Operating System: Native IxOS.
+```
+
+### Arm Servers
+
+```
+1. Arm Cortex A-72 servers
+ - 1 * ThunderX2
+ - Chassis: Marvell ThunderX2
+ - Processors: 2* ThunderX2 CN9975 ~ 112* ThunderX2.
+ - RAM Memory: 4* 32GB RDIMM
+ - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
+ - 2 * Huawei TaiShan 2280.
+ - Chassis: Huawei TaiShan 2280.
+ - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72.
+ - RAM Memory: 8* 16GB DDR4-2400MT/s.
+ - Disks: 1* 4TB SATA HDD.
+ - 3 * MACCHIATObin
+ - Chassis: MACCHIATObin.
+ - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72.
+ - RAM Memory: 1* 16GB DDR4.
+ - Disks: 1* 128GB(?) SATA SDD.
+```
+
+### Xeon and Atom Servers
+
+```
+1. Intel Xeon servers:
+ - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
+ - Chassis: SuperMicro SYS-7049GP-TRT.
+ - Motherboard: SuperMicro X11DPG-QT.
+ - Processors: 2* Intel Platinum 8180 2.3 GHz.
+ - RAM Memory: 16* 16GB DDR4-2666MHz.
+ - Disks: 2* 1.6TB 6G SATA SSD.
+2. Intel Atom servers with Rangely processors.
+ - 3 * Netgate XG-2758-1u
+ - Chassis: Netgate XG-2758-1u
+ - Processors: 1* Rangely (Atom) C2758 2.4 GHz
+ - RAM Memory: 16GB ECC
+ - Disks: 150 GB
+```
+
+### Network Interface Cards
+
+```
+1. 10GE NICs
+ - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
+ - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
+ - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
+2. 25GE NICs
+ - 12 * Intel® Ethernet Network Adapter XXV710-DA2
+3. 40GE NICs
+ - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
+4. 100GE NICs
+ - 4 * mcx556a-edat NICs (not on site yet, in transit)
+```
+
+### Pluggables and Cables
+
+Pluggables:
+
+```
+1. 10GE SFP+
+ - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
+ - 80 * 10G SR optic (generic, "Intel" compatible branded)
+2. 25GE SFP28
+ - None
+3. 40GE QSFP+
+ - None
+4. 100GE
+ - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
+```
+
+Standalone cables:
+
+```
+1. 10GE
+ - None
+2. 25GE
+ - None
+3. 40GE QSFP+
+ - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable
+4. 100GE
+ - None
+```
+
+### Other Parts
+
+None.